Dario Farina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dario Farina has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
R. Merletti
Centro di Bioingegneria, Dip. di Elettronica, Politecnico di Torino, Torino, Italy
3 shared publicationsRoberto Merletti
Dipartimento di Elettronica, Centro di Bioingegneria, Politecnico di Torino, Corso Duca degli Abruzzi 24, Torino 10129, Italy
3 shared publications- Thomas Graven-Nielsen
Center for Neuroplasticity and Pain (CNAP), Department of Health Science and Technology, Faculty of Medicine Aalborg University Aalborg Denmark
3 shared publications B. Indino
Centro di Bioingegneria, Dip. di Elettronica, Politecnico di Torino, Torino, Italy
2 shared publications- Lars Arendt-Nielsen
Center for Neuroplasticity and Pain (CNAP), Sensory-Motor Interaction (SMI) Center, Department of Health Science and Technology, Faculty of Medicine, Aalborg University, DK-9220 Aalborg, Denmark
2 shared publications - Roberto Merletti
Centro di Bioingegneria, Dipartimento di Elettronica, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129, Torino, Italy
2 shared publications
Latest Publications
- 1 January 2004
- Vol. 43 (1) , 30-5
Surface EMG crosstalk evaluated from experimental recordings and simulated signals. Reflections on crosstalk interpretation, quantification and reduction.
Surface EMG crosstalk is the EMG signal detected over a non-active muscle and generated by a nearby muscle. The aim of this study was to analyze the sources of crosstalk signals in surface EMG recordings and to discuss methods proposed in the literature for crosstalk quantification and reduction. The study is based on both simulated and experimental signals. The simulated signals are generated by a structure based surface EMG signal model. Signals were recorded with both intramuscular and surface electrodes and single motor unit surface potentials were extracted with the spike triggered averaging approach. Moreover, surface EMG signals were recorded from electrically stimulated muscles. From the simulation and experimental analysis it was clear that the main determinants of crosstalk are non-propagating signal components, generated by the extinction of the intracellular action potentials at the tendons. Thus, crosstalk signals have a different shape with respect to the signals detected over the active muscle and contain high frequency components. Since crosstalk has signal components different from those dominant in case of detection from near sources, commonly used methods to quantify and reduce crosstalk, such as the cross-correlation coefficient and high-pass temporal filtering, are not reliable. Selectivity of detection systems must be discussed separately as selectivity with respect to propagating and non-propagating signal components. The knowledge about the origin of crosstalk signal constitutes the basis for crosstalk interpretation, quantification, and reduction.
- 1 January 2004
- Vol. 43 (1) , 30-5
Surface EMG crosstalk evaluated from experimental recordings and simulated signals. Reflections on crosstalk interpretation, quantification and reduction.
Surface EMG crosstalk is the EMG signal detected over a non-active muscle and generated by a nearby muscle. The aim of this study was to analyze the sources of crosstalk signals in surface EMG recordings and to discuss methods proposed in the literature for crosstalk quantification and reduction. The study is based on both simulated and experimental signals. The simulated signals are generated by a structure based surface EMG signal model. Signals were recorded with both intramuscular and surface electrodes and single motor unit surface potentials were extracted with the spike triggered averaging approach. Moreover, surface EMG signals were recorded from electrically stimulated muscles. From the simulation and experimental analysis it was clear that the main determinants of crosstalk are non-propagating signal components, generated by the extinction of the intracellular action potentials at the tendons. Thus, crosstalk signals have a different shape with respect to the signals detected over the active muscle and contain high frequency components. Since crosstalk has signal components different from those dominant in case of detection from near sources, commonly used methods to quantify and reduce crosstalk, such as the cross-correlation coefficient and high-pass temporal filtering, are not reliable. Selectivity of detection systems must be discussed separately as selectivity with respect to propagating and non-propagating signal components. The knowledge about the origin of crosstalk signal constitutes the basis for crosstalk interpretation, quantification, and reduction.
- 1 January 2004
- Published by Georg Thieme Verlag KG in Methods of Information in Medicine
- Vol. 43 (01) , 30-35
Surface EMG Crosstalk Evaluated from Experimental Recordings and Simulated Signals
Objectives: Surface EMG crosstalk is the EMG signal detected over a non-active muscle and generated by a nearby muscle. The aim of this study was to analyze the sources of crosstalk signals in surface EMG recordings and to discuss methods proposed in the literature for crosstalk quantification and reduction. Methods: The study is based on both simulated and experimental signals. The simulated signals are generated by a structure based surface EMG signal model. Signals were recorded with both intramuscular and surface electrodes and single motor unit surface potentials were extracted with the spike triggered averaging approach. Moreover, surface EMG signals were recorded from electrically stimulated muscles. Results: From the simulation and experimental analysis it was clear that the main determinants of crosstalk are non-propagating signal components, generated by the extinction of the intracellular action potentials at the tendons. Thus, crosstalk signals have a different shape with respect to the signals detected over the active muscle and contain high frequency components. Conclusions: Since crosstalk has signal components different from those dominant in case of detection from near sources, commonly used methods to quantify and reduce crosstalk, such as the cross-correlation coefficient and high-pass temporal filtering, are not reliable. Selectivity of detection systems must be discussed separately as selectivity with respect to propagating and non-propagating signal components. The knowledge about the origin of crosstalk signal constitutes the basis for crosstalk interpretation, quantification, and reduction.
- 1 January 2004
- Published by Georg Thieme Verlag KG in Methods of Information in Medicine
- Vol. 43 (01) , 30-35
Surface EMG Crosstalk Evaluated from Experimental Recordings and Simulated Signals
Objectives: Surface EMG crosstalk is the EMG signal detected over a non-active muscle and generated by a nearby muscle. The aim of this study was to analyze the sources of crosstalk signals in surface EMG recordings and to discuss methods proposed in the literature for crosstalk quantification and reduction. Methods: The study is based on both simulated and experimental signals. The simulated signals are generated by a structure based surface EMG signal model. Signals were recorded with both intramuscular and surface electrodes and single motor unit surface potentials were extracted with the spike triggered averaging approach. Moreover, surface EMG signals were recorded from electrically stimulated muscles. Results: From the simulation and experimental analysis it was clear that the main determinants of crosstalk are non-propagating signal components, generated by the extinction of the intracellular action potentials at the tendons. Thus, crosstalk signals have a different shape with respect to the signals detected over the active muscle and contain high frequency components. Conclusions: Since crosstalk has signal components different from those dominant in case of detection from near sources, commonly used methods to quantify and reduce crosstalk, such as the cross-correlation coefficient and high-pass temporal filtering, are not reliable. Selectivity of detection systems must be discussed separately as selectivity with respect to propagating and non-propagating signal components. The knowledge about the origin of crosstalk signal constitutes the basis for crosstalk interpretation, quantification, and reduction.
- 20 March 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 50 (3) , 354-364
Selectivity of spatial filters for surface EMG detection from the tibialis anterior muscle
Many spatial filters have been proposed for surface electromyographic (EMG) signal detection. Although theoretical and modeling predictions on spatial selectivity are available, there are no extensive experimental validations of these techniques based on single motor unit (MU) activity detection. The aim of this study was to compare spatial selectivity of one- and two-dimensional (1-D and 2-D) spatial filters for EMG signal detection. Intramuscular and surface EMG signals were recorded from the tibialis anterior muscle of ten subjects. The simultaneous use of intramuscular wire and surface recordings (with the spike triggered averaging technique) allowed investigation of the activity of single MUs at the skin surface. The surface EMG signals were recorded with a grid of point electrodes (3/spl times/3 electrodes) and a ring electrode system at 15 locations over the muscle, with the wires detecting signals from the same intramuscular location. For most subjects, it was possible to classify, from the intramuscular recordings, the activity of the same MUs for all the contractions. The surface EMG signals were averaged with the intramuscularly detected MU action potentials as triggers. In this way, eight spatial filters-longitudinal and transversal, single and double differential (LSD, TSD, LDD, TDD), Laplacian (NDD), inverse binomial filter of the second order (IB2), inverse rectangle filter (IR), and differential ring system (C1)-could be compared on the basis of their spatial selectivity. The distance from the source (transversal with respect to the muscle fiber orientation) after which the surface detected potential did not exceed /spl plusmn/5% of the maximal peak-to-peak amplitude (detection distance) was statistically smaller for the 2-D systems and TDD than for the other filters. The MU action potential duration was significantly shorter with LDD and with the 2-D systems than with the other filters. The 2-D filters investigated (including C1) showed very similar performance and were, thus, considered equivalent from the point of view of spatial selectivity.
- 20 March 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 50 (3) , 354-364
Selectivity of spatial filters for surface EMG detection from the tibialis anterior muscle
Many spatial filters have been proposed for surface electromyographic (EMG) signal detection. Although theoretical and modeling predictions on spatial selectivity are available, there are no extensive experimental validations of these techniques based on single motor unit (MU) activity detection. The aim of this study was to compare spatial selectivity of one- and two-dimensional (1-D and 2-D) spatial filters for EMG signal detection. Intramuscular and surface EMG signals were recorded from the tibialis anterior muscle of ten subjects. The simultaneous use of intramuscular wire and surface recordings (with the spike triggered averaging technique) allowed investigation of the activity of single MUs at the skin surface. The surface EMG signals were recorded with a grid of point electrodes (3/spl times/3 electrodes) and a ring electrode system at 15 locations over the muscle, with the wires detecting signals from the same intramuscular location. For most subjects, it was possible to classify, from the intramuscular recordings, the activity of the same MUs for all the contractions. The surface EMG signals were averaged with the intramuscularly detected MU action potentials as triggers. In this way, eight spatial filters-longitudinal and transversal, single and double differential (LSD, TSD, LDD, TDD), Laplacian (NDD), inverse binomial filter of the second order (IB2), inverse rectangle filter (IR), and differential ring system (C1)-could be compared on the basis of their spatial selectivity. The distance from the source (transversal with respect to the muscle fiber orientation) after which the surface detected potential did not exceed /spl plusmn/5% of the maximal peak-to-peak amplitude (detection distance) was statistically smaller for the 2-D systems and TDD than for the other filters. The MU action potential duration was significantly shorter with LDD and with the 2-D systems than with the other filters. The 2-D filters investigated (including C1) showed very similar performance and were, thus, considered equivalent from the point of view of spatial selectivity.
- 1 November 2002
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 93 (5) , 1753-1763
Nonlinear surface EMG analysis to detect changes of motor unit conduction velocity and synchronization
Amplitude and frequency content of the surface electromyographic (EMG) signal reflect central and peripheral modifications of the neuromuscular system. Classic surface EMG spectral variables applied to assess muscle functions are the centroid and median power spectral frequencies. More recently, nonlinear tools have been introduced to analyze the surface EMG; among them, the recurrence quantification analysis (RQA) was shown to be particularly promising for the detection of muscle status changes. The purpose of this work was to analyze the effect of motor unit short-term synchronization and conduction velocity (CV) on EMG spectral variables and two variables extracted by RQA, the percentage of recurrence (%Rec) and determinism (%Det). The study was performed on the basis of a simulation model, which allowed changing the degree of synchronization and mean CV of a number of motor units, and of an experimental investigation of the surface EMG signal properties detected during high-force-level isometric fatiguing contractions of the biceps brachii muscle. Simulations and experimental results were largely in agreement and show that 1) spectral variables, %Rec, and %Det are influenced by CV and degree of synchronization; 2) spectral variables are highly correlated with %Det ( R = −0.95 in the simulations and −0.78 and −0.75 for the initial values and normalized slopes, respectively, in the experimental signals), and thus the information they provide on muscle properties is basically the same; and 3) variations of %Det and %Rec in response to changes in muscle properties are significantly larger than the variations of spectral variables. This study validates RQA as a means for fatigue assessment with potential advantages (such as the higher sensitivity to changes of muscle status) with respect to the classic spectral analysis.
- 1 November 2002
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 93 (5) , 1753-1763
Nonlinear surface EMG analysis to detect changes of motor unit conduction velocity and synchronization
Amplitude and frequency content of the surface electromyographic (EMG) signal reflect central and peripheral modifications of the neuromuscular system. Classic surface EMG spectral variables applied to assess muscle functions are the centroid and median power spectral frequencies. More recently, nonlinear tools have been introduced to analyze the surface EMG; among them, the recurrence quantification analysis (RQA) was shown to be particularly promising for the detection of muscle status changes. The purpose of this work was to analyze the effect of motor unit short-term synchronization and conduction velocity (CV) on EMG spectral variables and two variables extracted by RQA, the percentage of recurrence (%Rec) and determinism (%Det). The study was performed on the basis of a simulation model, which allowed changing the degree of synchronization and mean CV of a number of motor units, and of an experimental investigation of the surface EMG signal properties detected during high-force-level isometric fatiguing contractions of the biceps brachii muscle. Simulations and experimental results were largely in agreement and show that 1) spectral variables, %Rec, and %Det are influenced by CV and degree of synchronization; 2) spectral variables are highly correlated with %Det ( R = −0.95 in the simulations and −0.78 and −0.75 for the initial values and normalized slopes, respectively, in the experimental signals), and thus the information they provide on muscle properties is basically the same; and 3) variations of %Det and %Rec in response to changes in muscle properties are significantly larger than the variations of spectral variables. This study validates RQA as a means for fatigue assessment with potential advantages (such as the higher sensitivity to changes of muscle status) with respect to the classic spectral analysis.
- 16 September 2002
- Published by Wiley in Muscle & Nerve
- Vol. 26 (5) , 681-695
Surface EMG crosstalk between knee extensor muscles: Experimental and model results
Surface electromyographic (EMG) crosstalk between vastus lateralis, vastus medialis, and rectus femoris muscles was evaluated by selective electrical stimulation of one muscle and recording from the stimulated and another muscle with linear surface arrays of eight electrodes. The ratio between the amplitude of the signals recorded over nonstimulated and stimulated muscles and their correlation coefficient were used as indices to quantify crosstalk. Single‐differential and double‐differential detection systems were used with interelectrode distances in the range 10–40 mm. The multichannel EMG signals clearly showed that crosstalk is largely due to nonpropagating potentials that correspond in time to the end of the propagation of the action potentials generated by the stimulated muscle. The crosstalk signal increased with increasing interelectrode distance and was statistically higher for single‐ than for double‐differential recordings. The correlation‐based indices of crosstalk were poorly correlated with the amplitude‐based indices. Moreover, the characteristic spectral frequencies of the signals detected over the nonstimulated muscles were statistically higher than those from the stimulated muscles. A mathematical model of signal generation was used to explain the experimental findings. This study clarifies many controversial findings of past investigations and creates the basis for crosstalk interpretation, simulation, and reduction. © 2002 Wiley Periodicals, Inc. Muscle Nerve 26: 681–695, 2002
- 16 September 2002
- Published by Wiley in Muscle & Nerve
- Vol. 26 (5) , 681-695
Surface EMG crosstalk between knee extensor muscles: Experimental and model results
Surface electromyographic (EMG) crosstalk between vastus lateralis, vastus medialis, and rectus femoris muscles was evaluated by selective electrical stimulation of one muscle and recording from the stimulated and another muscle with linear surface arrays of eight electrodes. The ratio between the amplitude of the signals recorded over nonstimulated and stimulated muscles and their correlation coefficient were used as indices to quantify crosstalk. Single‐differential and double‐differential detection systems were used with interelectrode distances in the range 10–40 mm. The multichannel EMG signals clearly showed that crosstalk is largely due to nonpropagating potentials that correspond in time to the end of the propagation of the action potentials generated by the stimulated muscle. The crosstalk signal increased with increasing interelectrode distance and was statistically higher for single‐ than for double‐differential recordings. The correlation‐based indices of crosstalk were poorly correlated with the amplitude‐based indices. Moreover, the characteristic spectral frequencies of the signals detected over the nonstimulated muscles were statistically higher than those from the stimulated muscles. A mathematical model of signal generation was used to explain the experimental findings. This study clarifies many controversial findings of past investigations and creates the basis for crosstalk interpretation, simulation, and reduction. © 2002 Wiley Periodicals, Inc. Muscle Nerve 26: 681–695, 2002
- 19 February 2002
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 86 (6) , 469-478
Standardising surface electromyogram recordings for assessment of activity and fatigue in the human upper trapezius muscle
The objectives of this work were to determine optimal surface electromyogram (EMG) electrode locations, and inter-electrode distance (IED), when assessing activity and fatigue in the human upper trapezius muscle. Surface EMG signals were recorded from the upper trapezius muscle of 11 healthy male subjects using a linear array of 16 surface electrodes. Five arm positions were investigated (arms at the side of the body, 45° and 90° flexion, 45° and 90° abduction). Fatiguing (1 kg hand load held for 3 min) and non-fatiguing (no load, 0.5 kg and 1 kg hand load held for 3 s) contractions were made. The variabilities of the average rectified value, root mean square, mean and median power spectral frequency and slope over time of these parameters as functions of electrode location and IED (from 5 mm over a range of 35 mm in steps of 5 mm) were quantitatively evaluated. A criterion for selecting the optimal electrode position was applied. This criterion indicated an optimal location measured from the acromion (38% of the distance from the lateral edge of acromion to the spine of the seventh cervical vertebra) which was statistically the same for all the EMG descriptors, arm positions and IED investigated. Finally, it was found that both EMG variables and indexes of muscle fatigue depended on IED which should thus be properly standardised. On the basis of the sensitivity of the EMG descriptors to electrode location and cross-talk reduction, an IED of 20 mm is suggested when a global analysis of activity in the upper trapezius muscle is made using a single pair of electrodes. This study emphasises that a surface EMG analysis of the upper trapezius muscle, following a proper placement of the electrodes and selection of IED, can give reliable indications of muscle activity and fatigue. Data on the myoelectric manifestations of muscle fatigue of the upper trapezius muscle are provided for the optimal electrode location.
- 19 February 2002
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 86 (6) , 469-478
Standardising surface electromyogram recordings for assessment of activity and fatigue in the human upper trapezius muscle
The objectives of this work were to determine optimal surface electromyogram (EMG) electrode locations, and inter-electrode distance (IED), when assessing activity and fatigue in the human upper trapezius muscle. Surface EMG signals were recorded from the upper trapezius muscle of 11 healthy male subjects using a linear array of 16 surface electrodes. Five arm positions were investigated (arms at the side of the body, 45° and 90° flexion, 45° and 90° abduction). Fatiguing (1 kg hand load held for 3 min) and non-fatiguing (no load, 0.5 kg and 1 kg hand load held for 3 s) contractions were made. The variabilities of the average rectified value, root mean square, mean and median power spectral frequency and slope over time of these parameters as functions of electrode location and IED (from 5 mm over a range of 35 mm in steps of 5 mm) were quantitatively evaluated. A criterion for selecting the optimal electrode position was applied. This criterion indicated an optimal location measured from the acromion (38% of the distance from the lateral edge of acromion to the spine of the seventh cervical vertebra) which was statistically the same for all the EMG descriptors, arm positions and IED investigated. Finally, it was found that both EMG variables and indexes of muscle fatigue depended on IED which should thus be properly standardised. On the basis of the sensitivity of the EMG descriptors to electrode location and cross-talk reduction, an IED of 20 mm is suggested when a global analysis of activity in the upper trapezius muscle is made using a single pair of electrodes. This study emphasises that a surface EMG analysis of the upper trapezius muscle, following a proper placement of the electrodes and selection of IED, can give reliable indications of muscle activity and fatigue. Data on the myoelectric manifestations of muscle fatigue of the upper trapezius muscle are provided for the optimal electrode location.
- 1 January 2002
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 92 (1) , 235-247
Motor unit recruitment strategies investigated by surface EMG variables
During isometric contractions of increasing strength, motor units (MUs) are recruited by the central nervous system in an orderly manner starting with the smallest, with muscle fibers that usually show the lowest conduction velocity (CV). Theory predicts that the higher the velocity of propagation of the action potential, the higher the power at high frequencies of the detected surface signal. These considerations suggest that the power spectral density of the surface detected electromyogram (EMG) signal may give indications about the MU recruitment process. The purpose of this paper is to investigate the potential and limitations of spectral analysis of the surface EMG signal as a technique for the investigation of muscle force control. The study is based on a simulation approach and on an experimental investigation of the properties of surface EMG signals detected from the biceps brachii during isometric linearly increasing torque contractions. Both simulation and experimental data indicate that volume conductor properties play an important role as confounding factors that may mask any relation between EMG spectral variables and estimated CV as a size principle parameter during ramp contractions. The correlation between spectral variables and CV is thus significantly lower when the MU pool is not stable than during constant-torque isometric contractions. Our results do not support the establishment of a general relationship between spectral EMG variables and torque or recruitment strategy.
- 1 January 2002
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 92 (1) , 235-247
Motor unit recruitment strategies investigated by surface EMG variables
During isometric contractions of increasing strength, motor units (MUs) are recruited by the central nervous system in an orderly manner starting with the smallest, with muscle fibers that usually show the lowest conduction velocity (CV). Theory predicts that the higher the velocity of propagation of the action potential, the higher the power at high frequencies of the detected surface signal. These considerations suggest that the power spectral density of the surface detected electromyogram (EMG) signal may give indications about the MU recruitment process. The purpose of this paper is to investigate the potential and limitations of spectral analysis of the surface EMG signal as a technique for the investigation of muscle force control. The study is based on a simulation approach and on an experimental investigation of the properties of surface EMG signals detected from the biceps brachii during isometric linearly increasing torque contractions. Both simulation and experimental data indicate that volume conductor properties play an important role as confounding factors that may mask any relation between EMG spectral variables and estimated CV as a size principle parameter during ramp contractions. The correlation between spectral variables and CV is thus significantly lower when the MU pool is not stable than during constant-torque isometric contractions. Our results do not support the establishment of a general relationship between spectral EMG variables and torque or recruitment strategy.
- 1 January 2001
- Vol. 26, 63-6
Effect of electrode shape on spectral features of surface detected motor unit action potentials.
A method for simulating the effect of electrodes of any shape on surface detected motor unit action potentials (MUAPs) is described. The method is based on an approach we have recently proposed according to which the spatial integration of an electrode with physical dimensions is described as a two-dimensional spatial filtering of the electric potential over the skin. The effect of circular, square and bar electrodes on the frequency characteristics of surface detected MUAPs is investigated from the theoretical point of view. In particular the appearance of characteristic frequencies at which the power spectrum of the detected surface EMG signal is zero (spectral dips) is analyzed in relationship with electrode size and shape. It is shown that the physical dimensions of the electrodes may determine spectral dips in the surface EMG power spectrum but only for particular electrode shapes. Simulation results are shown to validate the theoretical considerations.
- 1 January 2001
- Vol. 26, 63-6
Effect of electrode shape on spectral features of surface detected motor unit action potentials.
A method for simulating the effect of electrodes of any shape on surface detected motor unit action potentials (MUAPs) is described. The method is based on an approach we have recently proposed according to which the spatial integration of an electrode with physical dimensions is described as a two-dimensional spatial filtering of the electric potential over the skin. The effect of circular, square and bar electrodes on the frequency characteristics of surface detected MUAPs is investigated from the theoretical point of view. In particular the appearance of characteristic frequencies at which the power spectrum of the detected surface EMG signal is zero (spectral dips) is analyzed in relationship with electrode size and shape. It is shown that the physical dimensions of the electrodes may determine spectral dips in the surface EMG power spectrum but only for particular electrode shapes. Simulation results are shown to validate the theoretical considerations.
- 1 January 2001
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 48 (1) , 66-77
A model for the generation of synthetic intramuscular EMG signals to test decomposition algorithms
As more and more intramuscular electromyogram (EMG) decomposition programs are being developed, there is a growing need for evaluating and comparing their performances. One way to achieve this goal is to generate synthetic EMG signals having known features. Features of interest are: the number of channels acquired (number of detection surfaces), the number of detected motor unit action potential (MUAP) trains, their time-varying firing rates, the degree of shape similarity among MUAPs belonging to the same motor unit (MU) or to different MUs, the degree of MUAP superposition, the MU activation intervals, the amount and type of additive noise. A model is proposed to generate one or more channels of intramuscular EMG starting from a library of real MUAPs represented in a 16-dimensional space using their Associated Hermite expansion. The MUAP shapes, regularity of repetition rate, degree of superposition, activation intervals, etc. may be time variable and are described quantitatively by a number of parameters which define a stochastic process (the model) with known statistical features. The desired amount of noise may be added to the synthetic signal which may then be processed by the decomposition algorithm under test to evaluate its capability of recovering the signal features.
- 1 January 2001
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 48 (1) , 66-77
A model for the generation of synthetic intramuscular EMG signals to test decomposition algorithms
As more and more intramuscular electromyogram (EMG) decomposition programs are being developed, there is a growing need for evaluating and comparing their performances. One way to achieve this goal is to generate synthetic EMG signals having known features. Features of interest are: the number of channels acquired (number of detection surfaces), the number of detected motor unit action potential (MUAP) trains, their time-varying firing rates, the degree of shape similarity among MUAPs belonging to the same motor unit (MU) or to different MUs, the degree of MUAP superposition, the MU activation intervals, the amount and type of additive noise. A model is proposed to generate one or more channels of intramuscular EMG starting from a library of real MUAPs represented in a 16-dimensional space using their Associated Hermite expansion. The MUAP shapes, regularity of repetition rate, degree of superposition, activation intervals, etc. may be time variable and are described quantitatively by a number of parameters which define a stochastic process (the model) with known statistical features. The desired amount of noise may be added to the synthetic signal which may then be processed by the decomposition algorithm under test to evaluate its capability of recovering the signal features.
- 1 January 2001
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 48 (11) , 1326-1334
Concentric-ring electrode systems for noninvasive detection of single motor unit activity
New recording techniques for detecting surface electromyographic (EMG) signals based on concentric-ring electrodes are proposed in this paper. A theoretical study of the two-dimensional (2-D) spatial transfer function of these recording systems is developed both in case of rings with a physical dimension and in case of line rings. Design criteria for the proposed systems are presented in relation to spatial selectivity. It is shown that, given the radii of the rings, the weights of the spatial filter can be selected in order to improve the rejection of low spatial frequencies, thus increasing spatial selectivity. The theoretical transfer functions of concentric systems are obtained and compared with those of other detection systems. Signals detected with the ring electrodes and with traditional one-dimensional and 2-D systems are compared. The concentric-ring systems show higher spatial selectivity with respect to the traditional detection systems and reduce the problem of electrode location since they are invariant to rotations. The results shown are very promising for the noninvasive detection of single motor unit (MU) activities and decomposition of the surface EMG signal into the constituent MU action potential trains.
- 1 January 2001
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 48 (11) , 1326-1334
Concentric-ring electrode systems for noninvasive detection of single motor unit activity
New recording techniques for detecting surface electromyographic (EMG) signals based on concentric-ring electrodes are proposed in this paper. A theoretical study of the two-dimensional (2-D) spatial transfer function of these recording systems is developed both in case of rings with a physical dimension and in case of line rings. Design criteria for the proposed systems are presented in relation to spatial selectivity. It is shown that, given the radii of the rings, the weights of the spatial filter can be selected in order to improve the rejection of low spatial frequencies, thus increasing spatial selectivity. The theoretical transfer functions of concentric systems are obtained and compared with those of other detection systems. Signals detected with the ring electrodes and with traditional one-dimensional and 2-D systems are compared. The concentric-ring systems show higher spatial selectivity with respect to the traditional detection systems and reduce the problem of electrode location since they are invariant to rotations. The results shown are very promising for the noninvasive detection of single motor unit (MU) activities and decomposition of the surface EMG signal into the constituent MU action potential trains.