Brian S. Sorg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Brian S. Sorg has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
Ashley J. Welch
Biomedical Engineering Program, University of Texas at Austin, Austin, Texas 78712
2 shared publications
Latest Publications
- 25 February 2003
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 32 (3) , 215-223
Preliminary biocompatibility experiment of polymer films for laser-assisted tissue welding
Background and Objectives The purpose of this study was to examine the impact of a polymer film for liquid solder strength reinforcement on the short term healing of a wound closed by laser‐tissue soldering. Materials and Methods Full thickness incisions created on the dorsum of Sprague–Dawley rats were closed by laser‐tissue soldering: albumin solder with Indocyanine Green (ICG) dye was inserted between the incision edges and photothermally coagulated with a diode laser. A poly(DL‐lactic‐co‐glycolic acid) (PLGA) polymer film was implanted subcutaneously in the bottom of the incision (controls had no film). Specimens were harvested at 0, 3, 7, and 14 days for breaking strength testing and histological analysis. Results Breaking strengths of the controls at 0 and 14 days were statistically stronger than the specimens with the implanted films (t‐test, P < 0.05). A slight difficulty in apposing the wound edges due to the film presence may have contributed to the low acute strengths. Interference with the wound contraction process by the films possibly contributed to the lower breaking strength at 14 days. Wound histology indicated a mild foreign body reaction to the polymer film material. Conclusions The polymer film was well tolerated by the tissue, and the tissue response to the material was consistent with that seen in the literature. The breaking strength differences between control and film‐implanted specimens at 0 and 14 days were probably the result of mechanical complications (tissue apposition and wound contraction) due to the presence of the film, and not due to the film material itself. The use of polymer film patches for liquid solder reinforcement and breaking strength enhancement may have certain application specific issues that need to be addressed. Strategies to account for these issues require further research. Lasers Surg. Med. 32:215–223, 2003.
- 25 February 2003
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 32 (3) , 215-223
Preliminary biocompatibility experiment of polymer films for laser-assisted tissue welding
Background and Objectives The purpose of this study was to examine the impact of a polymer film for liquid solder strength reinforcement on the short term healing of a wound closed by laser‐tissue soldering. Materials and Methods Full thickness incisions created on the dorsum of Sprague–Dawley rats were closed by laser‐tissue soldering: albumin solder with Indocyanine Green (ICG) dye was inserted between the incision edges and photothermally coagulated with a diode laser. A poly(DL‐lactic‐co‐glycolic acid) (PLGA) polymer film was implanted subcutaneously in the bottom of the incision (controls had no film). Specimens were harvested at 0, 3, 7, and 14 days for breaking strength testing and histological analysis. Results Breaking strengths of the controls at 0 and 14 days were statistically stronger than the specimens with the implanted films (t‐test, P < 0.05). A slight difficulty in apposing the wound edges due to the film presence may have contributed to the low acute strengths. Interference with the wound contraction process by the films possibly contributed to the lower breaking strength at 14 days. Wound histology indicated a mild foreign body reaction to the polymer film material. Conclusions The polymer film was well tolerated by the tissue, and the tissue response to the material was consistent with that seen in the literature. The breaking strength differences between control and film‐implanted specimens at 0 and 14 days were probably the result of mechanical complications (tissue apposition and wound contraction) due to the presence of the film, and not due to the film material itself. The use of polymer film patches for liquid solder reinforcement and breaking strength enhancement may have certain application specific issues that need to be addressed. Strategies to account for these issues require further research. Lasers Surg. Med. 32:215–223, 2003.
- 12 November 2002
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 31 (5) , 339-342
Tissue welding with biodegradable polymer films–demonstration of acute strength reinforcement in vivo
Background and Objectives: To demonstrate, in vivo, acute strength reinforcement benefits of polymer film patches.Study Design/Materials and Methods: Full thickness incisions created in a dorsal skin flap of Sprague–Dawley rats were closed by laser‐tissue welding: albumin solder was topically applied to the incision on the dermal surface, and a poly(lactic‐co‐glycolic acid) (PLGA) polymer film placed on the solder as a patch (controls had no film). Breaking strength was tested acutely (15–20 minutes after sacrifice).Results: The patched incisions were statistically stronger than the controls (ANOVA, P < 0.05).Conclusions: Polymer film patches may be a viable method to increase acute breaking strengths of welds using topically applied solder. Lasers Surg. Med. 31:339–342, 2002.
- 12 November 2002
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 31 (5) , 339-342
Tissue welding with biodegradable polymer films–demonstration of acute strength reinforcement in vivo
Background and Objectives: To demonstrate, in vivo, acute strength reinforcement benefits of polymer film patches.Study Design/Materials and Methods: Full thickness incisions created in a dorsal skin flap of Sprague–Dawley rats were closed by laser‐tissue welding: albumin solder was topically applied to the incision on the dermal surface, and a poly(lactic‐co‐glycolic acid) (PLGA) polymer film placed on the solder as a patch (controls had no film). Breaking strength was tested acutely (15–20 minutes after sacrifice).Results: The patched incisions were statistically stronger than the controls (ANOVA, P < 0.05).Conclusions: Polymer film patches may be a viable method to increase acute breaking strengths of welds using topically applied solder. Lasers Surg. Med. 31:339–342, 2002.