THTakashi Hirotani

Takashi Hirotani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Takashi Hirotani has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 June 2015
      • Vol. 68  (6) , 460-4

    [Aortic Valve Replacement after Balloon Valvuloplasty for Aortic Valve Stenosis in a Dialysis Patient with Cardiogenic Shock;Report of a Case].

    by Masanori Takamatsu, Takashi Hirotani, Satoshi Ohtsubo, Sumikatsu Saito, Shigeyuki Takeuchi, Tasuku Hasegawa, Ayaka Endo, Yu Yamasaki, Kentaro Hayashida

    A 67-year-old man on chronic hemodialysis was admitted with worsening congestive heart failure due to critical aortic stenosis. Echocardiography showed severe aortic stenosis with a valve area of 0.67 cm2 and an ejection fraction of 0.31. Cardiac catheterization revealed severe pulmonary hypertension with pulmonary artery pressures of 62/32 mmHg. In the middle of cardiac catheterization, the systolic pressure declined to 60 mmHg due to cardiogenic shock. Dopamine hydrochloride and dobutamine hydrochloride infusions were necessary to maintain a systolic pressure greater than 80 mmHg. Balloon aortic valvuloplasty was urgently performed. The patient's symptoms rapidly resolved except for angina on exertion. One month later, elective aortic valve replacement was performed. The postoperative course was uneventful and the he was discharged on the 60th postoperative day. A follow-up echocardiogram 6 months postoperatively revealed normal prosthetic valve function and an ejection fraction of 0.6.

    • 1 October 2004
      • Vol. 10  (5) , 314-6

    Mycotic aneurysm of the descending aorta with hemoptysis.

    by Mamoru Munakata, Takashi Hirotani, Tsukasa Nakamichi, Shigeyuki Takeuchi

    Mycotic aneurysm of the descending aorta is usually described as rare. We present two recent cases of mycotic aneurysm of the descending aorta complicated with hemoptysis. Urgent tube graft replacements were successfully performed under cardiopulmonary bypass support. Bacterial causes of the aneurysms were methicillin-resistant Staphylococcus aureus in the first case and Staphylococcus aureus in the second case. Although the first patient died fifteenth months after surgery, the second patient remains well fourteenth months after the operation.


  • Open Access

    Routine extended graft replacement for an acute type a aortic dissection and the patency of the residual false channel

    by Takashi Hirotani, Tsukasa Nakamichi, Mamoru Munakata, Shigeyuki Takeuchi


  • Risks and benefits of bilateral internal thoracic artery grafting in diabetic patients

    by Takashi Hirotani, Tsukasa Nakamichi, Mamoru Munakata, Shigeyuki Takeuchi


    • 1 October 2002
      • Vol. 8  (5) , 281-5

    A modified infarct exclusion technique for a post-infarction ventricular septal defect.

    by Takashi Hirotani, Tsukasa Nakamichi

    Operative mortality for a post-infarction ventricular septal defect (VSD) remains high. The infarct exclusion technique has been producing a favorable outcome for repairing this serious defect. However, there is the technical weakness, namely running suture along the base of the necrotic septum. We sutured a pericardial patch using multiple interrupted mattress sutures in such a manner as to exclude the infarct and VSD. Over the past seven years, nine consecutive patients with a post-infarction VSD underwent an early repair in the same manner. The VSD was anterior in eight patients and posterior in one. We sutured a xenopericardial patch to the healthy myocardium around the infarct using interrupted mattress sutures instead of running sutures as the infarct exclusion technique. In addition, on the postero-inferior margin of the patch, one or two mattress sutures passing through the full thickness of the anterior papillary muscle were used. Only one patient died of pneumonia 50 days after surgery. The other eight patients were followed up and were functionally classified as NYHA class I or II. These findings suggest that our modified infarct exclusion technique using multiple mattress sutures is an effective alternative surgical technique.


  • Feasibility and suitability of the routine use of bilateral internal thoracic arteries

    by Takashi Hirotani, Shogo Shirota, Yasunori Cho, Shigeyuki Takeuchi


    • 1 February 2002
      • Vol. 8  (1) , 18-23

    Reoperation for coronary artery disease: devised management for reoperation including digital subtraction angiography.

    by Takayuki Kumamoto, Takashi Hirotani, Tadashi Kameda, Shogo Shirota

    Between December 1990 and August 1999, a consecutive series of 494 patients underwent coronary artery bypass grafting, while 19 (3.8%) patients underwent isolated reoperative coronary bypass grafting. The mean age of 16 males and 3 females who underwent reoperation was 63.4 +/- 6.4 years. The mean interval from the initial operation to reoperation was 50.7 +/- 61.0 months (range 3 days to 16 years). There were neither operative nor in-hospital deaths. Postoperative graft patency was 96.9% in all the bypass grafts and 96.7% in the arterial grafts. Despite the small number of reoperations, the outcomes were favorable due to our devised management: the patients who had received coronary artery bypass grafting underwent intra-aortic digital subtraction angiography 7 days postoperatively to evaluate the early graft patency, which subsequently avoided reoperation 1 to 3 months after the initial operation when the pericardial adhesion was tight; in the primary operation, internal thoracic artery grafts were covered with thymus, and the pericardium was closed for an easy sternal re-entry; and in the reoperation, stenotic grafts were dissected and ligated after aortic cross-clamping, all sides of the heart were dissected to obtain a good operative field and to prepare for any cardiac accident, arterial grafts were used to avoid re-reoperation, and aprotinin was useful in reducing perioperative bleeding. The present findings suggest that intra-aortic digital subtraction angiography, appropriate preparation for follow-up surgery at the primary operation, and complete revascularization using arterial grafts at reoperation appear to have contributed to the satisfactory outcome in coronary reoperation.

  • Open Access

    Reply to D'Ancona et al.

    by Takashi Hirotani

    We appreciate the comments on our article [1], which were raised by Dr D'Ancona and co-workers. We agree with them in the point that the interpretation of mean flow values together with transit time flow curves and PI values may improve the ability to detect bypass failure. In fact, when the mean flow rate of a bypass graft is low, its flow curve indicating the diastolic dominance, as well as PI values included between 1 and 5, may help us to regard the graft as having no problems. In the study of our series, however, two of seven internal thoracic artery (ITA) grafts with more than 75% stenosis at their anastomosed sites showed the mean flow rate of higher than 80 ml/min, and three of eleven ITA grafts which showed a string sign on the pre-discharge coronary angiography, had the mean flow rate of higher than 100 ml/min. We consider the existence of the process, in which the anastomosed site is slowly narrowed after closure of the sternum or in which the caliber of ITA grafts is gradually adapted to the appropriate size according to the myocardial oxygen demands after surgery.

  • Open Access

    An evaluation of the intraoperative transit time measurements of coronary bypass flow

    by Takashi Hirotani, Tadashi Kameda, Shogo Shirota, Yoshihisa Nakao

    Objective: The intraoperative measurement of the coronary bypass flow enables the identification of technical errors while the sternum is still open. The transit-time flow method is able to effectively measure the internal thoracic artery graft flow. The aim of the present study was to analyze the factors which affected the bypass flow rate. Methods: We measured the blood flow of 291 in situ internal thoracic artery (ITA) and 190 saphenous vein (SV) grafts constructed in 171 patients undergoing coronary artery bypass grafting from December 1996 to March 2000 using this method during the surgery. All patients underwent postoperative coronary angiography before the patients were discharged. The blood flow rate of all bypass grafts constructed was assessed after the patients were weaned from cardiopulmonary bypass. Results: The mean flow rate of all ITA grafts was 65.1±36.7 ml/min and that of all SV grafts was 56.4±29.9 ml/min. According to analyses using correlation tests, the graft flow was found to significantly correlate with the grafted perfusion areas and the diameter of the bypassed coronary arteries. However, no significant difference was observed between the flow rates of the ITA grafts with and without stenosis or string phenomenon, but significant (P≪0.0001) correlation was observed between the occurrence of a string sign and the degree of proximal stenosis of the recipient coronary artery. Regarding SV grafts, the mean flow rate of occluded grafts (29.2±20.5 ml/min) was significantly (P≪0.0001) less than non-occluded grafts (56.4±29.9 ml/min). Conclusions: The bypass flow was affected by such a large number of factors that only measuring the bypass flow rate could not sufficiently predict either stenosed or narrowed grafts. However, ITA grafts bypassed to the coronary arteries with less stenosis were shown to more easily become narrowed.


  • Aortic arch repair using hypothermic circulatory arrest technique associated with pharmacological brain protection

    by Takashi Hirotani, Tadashi Kameda, Takayuki Kumamoto, Shogo Shirota

    Hypothermic circulatory arrest is a standard procedure for the treatment of aortic arch. However, there is a time limit for this procedure. There is now an urgent need to develop prophylactic measures to extend the time limit. We have used a pharmacological mixture of thiopental, nicardipine and mannitol for all patients undergoing circulatory arrest since 1991 to extend the safe limit. The purpose of this study was to analyze the neurological complications demonstrated by these patients and to evaluate the brain-protective effects of our measure. The clinical records of 75 consecutive patients undergoing an aortic arch repair using a hypothermic circulatory arrest technique during the past 8 years were retrospectively reviewed. Systemic cooling was continued until a total disappearance of EEG activity. Prior to circulatory arrest, 15 or 30 mg/kg of thiopental, 20 mg of nicardipine and 300 ml of mannitol were infused into the venous reservoir of a cardiopulmonary bypass circuit. Graft replacement was performed in all patients and the extent of replacement was a total aortic arch in 43 patients, a distal aortic arch in 17, a hemiarch in 13 and a distal aortic arch and a total descending aorta in two. The duration of circulatory arrest ranged from 16 to 80 min (mean 41.5 min), and it exceeded 45 min in 37 patients. Operative mortality was 10.7% and two patients died of stroke. Three patients had permanent and three other patients had transient neural deficits. The incidence of stroke was 8.0% as a whole, and no correlation between the incidence of neurological complications and the duration of circulatory arrest was found. A multivariate analysis showed that the duration of circulatory arrest was determined as a predictor of neither operative mortality nor postoperative stroke. The findings of the present study suggest that our pharmacological brain protection appears to be effective for safely extending hypothermic circulatory arrest.