Renshi Sawada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Renshi Sawada has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Eiji Higurashi
Graduate School of Engineering, Tohoku University, Sendai, Japan
12 shared publications Takahiro Ito
4 shared publications- Tadatomo Suga
Collaborative Research Center, Meisei University, Hino-shi, Tokyo 191-8506, Japan
2 shared publications Akira Shimizu
NTT Microsystem Integration Laboratories, Nippon Telegraph and Telephone Corp
1 shared publication- Hirofumi Nogami
Department of Mechanical Engineering, Faculty of Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan
1 shared publication Hiroshi Koshimizu
NTT-AT
1 shared publication
Latest Publications
- Open Access
- 1 January 2018
- Published by INSTICC
- p. 48-53
Simultaneous Measurement of a Blood Flow and a Contact Pressure
- 1 January 2018
- Published by INSTICC
- p. 48-53
Open AccessSimultaneous Measurement of a Blood Flow and a Contact Pressure
- 1 January 2013
- Published by INSTICC
- p. 30-37
Stable Measurement of Blood Flow while Running Using a Micro Blood Flowmeter
Skin blood flow during exercise has been studied before, with measurements made using laser Doppler blood flowmeters; however, their use was limited to activities with minimal motion, such as riding bicycle ergometers, because conventional devices are large and their measurements easily altered by movements of the optical fiber, rendering them inappropriate for running. We have previously developed a micro integrated laser Doppler blood flowmeter using microelectromechanical systems (MEMS) technology. The micro blood flowmeter is wearable and can measure signal stably even while the wearer is moving. We monitored skin blood flow during running at velocities of 6 km/h, 8 km/h, and 10 km/h, and were successful in measuring a stable signal under these conditions. We found that at the forehead the skin blood flow increases and, in contrast, at the fingertip it initially decreases during running. We also found that the level of these increases and decreases correlated with the running velo
- 1 January 2013
- Published by INSTICC
- p. 30-37
Stable Measurement of Blood Flow while Running Using a Micro Blood Flowmeter
Skin blood flow during exercise has been studied before, with measurements made using laser Doppler blood flowmeters; however, their use was limited to activities with minimal motion, such as riding bicycle ergometers, because conventional devices are large and their measurements easily altered by movements of the optical fiber, rendering them inappropriate for running. We have previously developed a micro integrated laser Doppler blood flowmeter using microelectromechanical systems (MEMS) technology. The micro blood flowmeter is wearable and can measure signal stably even while the wearer is moving. We monitored skin blood flow during running at velocities of 6 km/h, 8 km/h, and 10 km/h, and were successful in measuring a stable signal under these conditions. We found that at the forehead the skin blood flow increases and, in contrast, at the fingertip it initially decreases during running. We also found that the level of these increases and decreases correlated with the running velo
- 1 January 2013
- Published by Japan Society for Precision Engineering in Journal of the Japan Society for Precision Engineering
- Vol. 79 (8) , 719-724
Low-Temperature Bonding Technologies Realizing High-Functional Optical Microsystems and Sensors
- 1 January 2013
- Published by Japan Society for Precision Engineering in Journal of the Japan Society for Precision Engineering
- Vol. 79 (8) , 719-724
Low-Temperature Bonding Technologies Realizing High-Functional Optical Microsystems and Sensors
- 12 July 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Low-temperature bonding of optical chips using coined Au stud bumps and its application to micro laser Doppler velocimeter
Surface activated bonding of laser diode (LD) chips on coined Au stud bumps (thickness: 10~15 μm) with smooth surfaces (Ra <; 3.5 nm) was demonstrated for optical microsensor applications. Bonding of LD chips with Au thin films to the Au stud bumps on the Si substrates was performed in ambient air at low temperature (150 °C). Die-shear strength per unit area was three times as high as that obtained between Au thin films (thickness: 0.5 μm). Using this technique, compact and thin micro laser Doppler velocimeter (2.8 mm × 2.8 mm × 1 mm thick) was developed. The feasibility of measuring velocity was demonstrated for a moving Au wire (diameter: 22 μm).
- 12 July 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Low-temperature bonding of optical chips using coined Au stud bumps and its application to micro laser Doppler velocimeter
Surface activated bonding of laser diode (LD) chips on coined Au stud bumps (thickness: 10~15 μm) with smooth surfaces (Ra <; 3.5 nm) was demonstrated for optical microsensor applications. Bonding of LD chips with Au thin films to the Au stud bumps on the Si substrates was performed in ambient air at low temperature (150 °C). Die-shear strength per unit area was three times as high as that obtained between Au thin films (thickness: 0.5 μm). Using this technique, compact and thin micro laser Doppler velocimeter (2.8 mm × 2.8 mm × 1 mm thick) was developed. The feasibility of measuring velocity was demonstrated for a moving Au wire (diameter: 22 μm).
- 1 January 2010
- Published by Japan Society for Precision Engineering in Journal of the Japan Society for Precision Engineering
- Vol. 76 (5) , 491-497
Technology for MEMS Commercialization : Current Status and Future Prospects
- 1 January 2010
- Published by Japan Society for Precision Engineering in Journal of the Japan Society for Precision Engineering
- Vol. 76 (5) , 491-497
Technology for MEMS Commercialization : Current Status and Future Prospects
- 1 January 2005
- Published by Laser Society of Japan in The Review of Laser Engineering
- Vol. 33 (11) , 761-765
Angular Alignment and Optical Drive of Optically Trapped Micro-Components
- 1 January 2005
- Published by Laser Society of Japan in The Review of Laser Engineering
- Vol. 33 (11) , 761-765
Angular Alignment and Optical Drive of Optically Trapped Micro-Components
- 1 January 2005
- Published by Laser Society of Japan in The Review of Laser Engineering
- Vol. 33 (11) , 732-738
Laser-Based Microsensors
- 1 January 2005
- Published by Laser Society of Japan in The Review of Laser Engineering
- Vol. 33 (11) , 732-738
Laser-Based Microsensors
- 14 August 2003
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 13 (6) , 942-947
Integrated micro-displacement sensor that uses beam divergence
- 14 August 2003
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 13 (6) , 942-947
Integrated micro-displacement sensor that uses beam divergence
- 1 January 2003
- Published by Japan Society of Mechanical Engineers in Proceedings of JSME-IIP/ASME-ISPS Joint Conference on Micromechatronics for Information and Precision Equipment : IIP/ISPS Joint MIPE
- Vol. 2003, 261-262
OD-04 CHARACTERISTICS AND CONTROL OF MEMS MIRRORS FOR OPTICAL CROSS-CONNECT SWITCH
- 1 January 2003
- Published by Japan Society of Mechanical Engineers in Proceedings of JSME-IIP/ASME-ISPS Joint Conference on Micromechatronics for Information and Precision Equipment : IIP/ISPS Joint MIPE
- Vol. 2003, 261-262
OD-04 CHARACTERISTICS AND CONTROL OF MEMS MIRRORS FOR OPTICAL CROSS-CONNECT SWITCH
- 22 April 2002
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 12 (3) , 286-290
Integrated microlaser displacement sensor
A new integrated optical microlaser displacement sensor that includes a Michelson interferometer was developed and its feasibility as a measurement device was confirmed. The sensor can measure the relative distance travelled against an outside reflective mirror. The measurement resolution is expected to be of the order of 0.01 μm. Its dimensions are 2.0 mm by 1.6 mm. Therefore, the displacement sensor itself can be moved at high speed because its inertia is extremely small and can be incorporated into a microstage and microsystem.
- 22 April 2002
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 12 (3) , 286-290
Integrated microlaser displacement sensor
A new integrated optical microlaser displacement sensor that includes a Michelson interferometer was developed and its feasibility as a measurement device was confirmed. The sensor can measure the relative distance travelled against an outside reflective mirror. The measurement resolution is expected to be of the order of 0.01 μm. Its dimensions are 2.0 mm by 1.6 mm. Therefore, the displacement sensor itself can be moved at high speed because its inertia is extremely small and can be incorporated into a microstage and microsystem.