Takayoshi Kohmura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Takayoshi Kohmura has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Katsuji Koyama
Department of Physics, Graduate School of Science, Kyoto University, Sakyo-ku, Kyoto 606-8502
4 shared publications Hiroshi Murakami
Rikkyo Univ. (Japan)
3 shared publications- Hiroshi Tsunemi
Osaka University
3 shared publications - Shunji Kitamoto
Department of Physics, Rikkyo University
3 shared publications Daisuke Matsuura
Osaka Univ. (Japan)
2 shared publicationsEmi Miyata
Osaka Univ. (Japan)
2 shared publications
Latest Publications
- 12 July 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7011, 70112L
NeXT SXI data processing system
The Soft X-ray Imager (SXI) is the X-ray CCD detector system on board the NeXT mission that is to be launched around 2013. The system consists of a camera, an SXI-specific data processing unit (SXI-E) and a CPU unit commonly used throughout the NeXT satellite. All the analog signal handling is restricted within the camera unit, and all the I/O of the unit are digital. The camera unit and SXI-E are connected by multiple LVDS lines, and SXI-E and the CPU unit will be connected by a SpaceWire (SpW) network. The network can connect SXI-E to multiple CPU units (the formal SXI CPU and neighbors) and all the CPU units in the network have connections to multiple neighbors: with this configuration, the SXI system can work even in the case that one SpW connection or the formal SXI CPU is down. The main tasks of SXI-E are to generate the CCD driving pattern, the acquisition of the image data stream and HK data supplied by the camera and transfer them to the CPU unit with the Remote Memory Access Protocol (RMAP) over SpW. In addition to them, SXI-E also detects the pixels whose values are higher than the event threshold and both adjacent pixels in the same line, and send their coordinates to the CPU unit. The CPU unit can reduce its load significantly with this information because it gets rid of the necessity to scan whole the image to detect X-ray events.
- 12 July 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7011, 70112L
NeXT SXI data processing system
The Soft X-ray Imager (SXI) is the X-ray CCD detector system on board the NeXT mission that is to be launched around 2013. The system consists of a camera, an SXI-specific data processing unit (SXI-E) and a CPU unit commonly used throughout the NeXT satellite. All the analog signal handling is restricted within the camera unit, and all the I/O of the unit are digital. The camera unit and SXI-E are connected by multiple LVDS lines, and SXI-E and the CPU unit will be connected by a SpaceWire (SpW) network. The network can connect SXI-E to multiple CPU units (the formal SXI CPU and neighbors) and all the CPU units in the network have connections to multiple neighbors: with this configuration, the SXI system can work even in the case that one SpW connection or the formal SXI CPU is down. The main tasks of SXI-E are to generate the CCD driving pattern, the acquisition of the image data stream and HK data supplied by the camera and transfer them to the CPU unit with the Remote Memory Access Protocol (RMAP) over SpW. In addition to them, SXI-E also detects the pixels whose values are higher than the event threshold and both adjacent pixels in the same line, and send their coordinates to the CPU unit. The CPU unit can reduce its load significantly with this information because it gets rid of the necessity to scan whole the image to detect X-ray events.
- Open Access
- 30 January 2007
- Published by Oxford University Press (OUP) in Publications of the Astronomical Society of Japan
- Vol. 59 (sp1) , S361-S367
Swift and Suzaku Observations of the X-Ray Afterglow from the GRB 060105
Results are presented of early X-ray afterglow observations of GRB 060105 by Swift and Suzaku. The bright, long gamma-ray burst GRB 060105 triggered the Swift Burst Alert Telescope at 06:49:28 on 2006 January 5 ($$T_0$$). The Suzaku team commenced a pre-planned target of opportunity observation at 19 ks (5.3 hr) after the Swift trigger. The X-ray flux faded during observations from $$6.8 \times 10^{-9} \,\mathrm{erg} \,\mathrm{s}^{-1} \,\mathrm{cm}^{-2}$$ (at $$T_0 + 87 \,\mathrm{s}$$ with the Swift/XRT) to $$1.5 \times 10^{-13} \,\mathrm{erg} \,\mathrm{s}^{-1} \,\mathrm{cm}^{-2}$$ [at $$T_0 + 94 \hbox{}{--} 101 \,\mathrm{ks}$$ with the Suzaku X-ray Imaging Spectrometer (XIS)] in the 2–10 keV energy band. Following prompt emission and successive very steep decay, a shallow decay was observed from $$T_0 + 187 \,\mathrm{s}$$ to $$T_0 + 1287 \,\mathrm{s}$$. After an observation gap during $$T_0 + (1.5 \hbox{}{--} 3) \;\mathrm{ks}$$, an extremely early steep decay was observed in $$T_0 + (4 \hbox{}{--} 30) \;\mathrm{ks}$$. The lightcurve flattened again at $$T_0 + 30 \,\mathrm{ks}$$, and another steep decay followed from $$T_0 + 50 \,\mathrm{ks}$$ to the end of observations. Both steep decays exhibited decay indices of 2.3–2.4. This very early break, if it is a jet break, is the earliest case among X-ray afterglow observations, suggesting a very narrow jet whose opening angle is well below $$1^\circ$$. The unique Suzaku/XIS data allow us to set very tight upper limits on line emission or absorption in this GRB. For the reported pseudo-redshift of $$z = 4.0 \pm 1.3$$ the upper limit on the iron line equivalent width is 50 eV.- 30 January 2007
- Published by Oxford University Press (OUP) in Publications of the Astronomical Society of Japan
- Vol. 59 (sp1) , S361-S367
Open AccessSwift and Suzaku Observations of the X-Ray Afterglow from the GRB 060105
Results are presented of early X-ray afterglow observations of GRB 060105 by Swift and Suzaku. The bright, long gamma-ray burst GRB 060105 triggered the Swift Burst Alert Telescope at 06:49:28 on 2006 January 5 ($$T_0$$). The Suzaku team commenced a pre-planned target of opportunity observation at 19 ks (5.3 hr) after the Swift trigger. The X-ray flux faded during observations from $$6.8 \times 10^{-9} \,\mathrm{erg} \,\mathrm{s}^{-1} \,\mathrm{cm}^{-2}$$ (at $$T_0 + 87 \,\mathrm{s}$$ with the Swift/XRT) to $$1.5 \times 10^{-13} \,\mathrm{erg} \,\mathrm{s}^{-1} \,\mathrm{cm}^{-2}$$ [at $$T_0 + 94 \hbox{}{--} 101 \,\mathrm{ks}$$ with the Suzaku X-ray Imaging Spectrometer (XIS)] in the 2–10 keV energy band. Following prompt emission and successive very steep decay, a shallow decay was observed from $$T_0 + 187 \,\mathrm{s}$$ to $$T_0 + 1287 \,\mathrm{s}$$. After an observation gap during $$T_0 + (1.5 \hbox{}{--} 3) \;\mathrm{ks}$$, an extremely early steep decay was observed in $$T_0 + (4 \hbox{}{--} 30) \;\mathrm{ks}$$. The lightcurve flattened again at $$T_0 + 30 \,\mathrm{ks}$$, and another steep decay followed from $$T_0 + 50 \,\mathrm{ks}$$ to the end of observations. Both steep decays exhibited decay indices of 2.3–2.4. This very early break, if it is a jet break, is the earliest case among X-ray afterglow observations, suggesting a very narrow jet whose opening angle is well below $$1^\circ$$. The unique Suzaku/XIS data allow us to set very tight upper limits on line emission or absorption in this GRB. For the reported pseudo-redshift of $$z = 4.0 \pm 1.3$$ the upper limit on the iron line equivalent width is 50 eV. - 14 June 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6266, 62662V
X-ray polarimeter with a multilayer-coated CCD
We report a new type X-ray imaging polarimeter: a multilayer-coated CCD. When the X-rays are detected by the CCD, with the incident angle of 45 deg, through the coated multi-layer, the transmissions of the P and S polarized photons are different from each other and we can get an image with a selected position angle of the polarization. By the simulation of the transmission of the multi-layer, we designed an optimal number of the layer-pair and their thickness. The target wave length is 135Å, because the Mo/Si multi-layer has a good performance in this energy range. If the dead layer of the back-side CCD is 1000Å, nine layer-pairs make the largest difference between the P and S transmission. We deposited the Mo/Si multi-layer directly on a back-side CCD. The CCD was exposed to the polarized photons from synchrotron radiation with 45 deg incident angle. The detected intensity is measured as a function of the photon energy and of the rotation angle around the photon beam. The detection of the polarization is confirmed. However the measured performance is lower than expected. Some possibilities of the cause are discussed.
- 14 June 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6266, 62662V
X-ray polarimeter with a multilayer-coated CCD
We report a new type X-ray imaging polarimeter: a multilayer-coated CCD. When the X-rays are detected by the CCD, with the incident angle of 45 deg, through the coated multi-layer, the transmissions of the P and S polarized photons are different from each other and we can get an image with a selected position angle of the polarization. By the simulation of the transmission of the multi-layer, we designed an optimal number of the layer-pair and their thickness. The target wave length is 135Å, because the Mo/Si multi-layer has a good performance in this energy range. If the dead layer of the back-side CCD is 1000Å, nine layer-pairs make the largest difference between the P and S transmission. We deposited the Mo/Si multi-layer directly on a back-side CCD. The CCD was exposed to the polarized photons from synchrotron radiation with 45 deg incident angle. The detected intensity is measured as a function of the photon energy and of the rotation angle around the photon beam. The detection of the polarization is confirmed. However the measured performance is lower than expected. Some possibilities of the cause are discussed.
- 14 June 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6266, 62662I
Soft x-ray imager (SXI) onboard the NeXT satellite
We give overview and the current status of the development of the Soft X-ray Imager (SXI) onboard the NeXT satellite. SXI is an X-ray CCD camera placed at the focal plane detector of the Soft X-ray Telescopes for Imaging (SXT-I) onboard NeXT. The pixel size and the format of the CCD is 24 x 24μm (IA) and 2048 x 2048 x 2 (IA+FS). Currently, we have been developing two types of CCD as candidates for SXI, in parallel. The one is front illumination type CCD with moderate thickness of the depletion layer (70 ~ 100μm) as a baseline plan. The other one is the goal plan, in which we develop back illumination type CCD with a thick depletion layer (200 ~ 300μm). For the baseline plan, we successfully developed the proto model 'CCD-NeXT1' with the pixel size of 12μm x 12μm and the CCD size of 24mm x 48mm. The depletion layer of the CCD has reached 75 ~ 85μm. The goal plan is realized by introduction of a new type of CCD 'P-channel CCD', which collects holes in stead of electrons in the common 'N-channel CCD'. By processing a test model of P-channel CCD we have confirmed high quantum efficiency above 10 keV with an equivalent depletion layer of 300μm. A back illumination type of P-channel CCD with a depletion layer of 200μm with aluminum coating for optical blocking has been also successfully developed. We have been also developing a thermo-electric cooler (TEC) with the function of the mechanically support of the CCD wafer without standoff insulators, for the purpose of the reduction of thermal input to the CCD through the standoff insulators. We have been considering the sensor housing and the onboard electronics for the CCD clocking, readout and digital processing of the frame date.
- 14 June 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6266, 62662I
Soft x-ray imager (SXI) onboard the NeXT satellite
We give overview and the current status of the development of the Soft X-ray Imager (SXI) onboard the NeXT satellite. SXI is an X-ray CCD camera placed at the focal plane detector of the Soft X-ray Telescopes for Imaging (SXT-I) onboard NeXT. The pixel size and the format of the CCD is 24 x 24μm (IA) and 2048 x 2048 x 2 (IA+FS). Currently, we have been developing two types of CCD as candidates for SXI, in parallel. The one is front illumination type CCD with moderate thickness of the depletion layer (70 ~ 100μm) as a baseline plan. The other one is the goal plan, in which we develop back illumination type CCD with a thick depletion layer (200 ~ 300μm). For the baseline plan, we successfully developed the proto model 'CCD-NeXT1' with the pixel size of 12μm x 12μm and the CCD size of 24mm x 48mm. The depletion layer of the CCD has reached 75 ~ 85μm. The goal plan is realized by introduction of a new type of CCD 'P-channel CCD', which collects holes in stead of electrons in the common 'N-channel CCD'. By processing a test model of P-channel CCD we have confirmed high quantum efficiency above 10 keV with an equivalent depletion layer of 300μm. A back illumination type of P-channel CCD with a depletion layer of 200μm with aluminum coating for optical blocking has been also successfully developed. We have been also developing a thermo-electric cooler (TEC) with the function of the mechanically support of the CCD wafer without standoff insulators, for the purpose of the reduction of thermal input to the CCD through the standoff insulators. We have been considering the sensor housing and the onboard electronics for the CCD clocking, readout and digital processing of the frame date.
- Open Access
- 1 December 2001
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 562 (2) , 943-949
Delayed Iron Lines in Centaurus X‐3
We present the study of the aperiodic time variation of the binary X-ray pulsar Centaurus X-3 observed with the Rossi X-Ray Timing Explorer (RXTE). We extracted light curves from six energy bands and calculated cross-spectral functions between the energy band containing the iron K lines (iron band) and the remaining bands. We discovered, for the first time, that the temporal variation of iron band emission is delayed as compared with that of the other energy X-rays by 0.39 ± 0.10 ms (1 σ error). We also discovered that the time difference shows a general trend such that the higher energy X-rays are advanced in comparison with the lower energy X-rays with the exception of the iron band. Assuming that the iron emission lines are fluorescent lines in origin and are emitted by circumstellar matter, we derived 5.6 ± 1.5 ms for the time delay of the temporal variation of the iron line from the average temporal variation in the energy band above the iron absorption edge, taking into account the energy spectral shape and the photoelectric absorption cross section. This result leads to a determination of (1.7 ± 0.5) × 108 cm for the distance between the original X-ray source and the reprocessor, which emits the iron lines. The general trend of the hard X-ray advance is considered to be related to the X-ray emission mechanism on the neutron star.
- 1 December 2001
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 562 (2) , 943-949
Open AccessDelayed Iron Lines in Centaurus X‐3
We present the study of the aperiodic time variation of the binary X-ray pulsar Centaurus X-3 observed with the Rossi X-Ray Timing Explorer (RXTE). We extracted light curves from six energy bands and calculated cross-spectral functions between the energy band containing the iron K lines (iron band) and the remaining bands. We discovered, for the first time, that the temporal variation of iron band emission is delayed as compared with that of the other energy X-rays by 0.39 ± 0.10 ms (1 σ error). We also discovered that the time difference shows a general trend such that the higher energy X-rays are advanced in comparison with the lower energy X-rays with the exception of the iron band. Assuming that the iron emission lines are fluorescent lines in origin and are emitted by circumstellar matter, we derived 5.6 ± 1.5 ms for the time delay of the temporal variation of the iron line from the average temporal variation in the energy band above the iron absorption edge, taking into account the energy spectral shape and the photoelectric absorption cross section. This result leads to a determination of (1.7 ± 0.5) × 108 cm for the distance between the original X-ray source and the reprocessor, which emits the iron lines. The general trend of the hard X-ray advance is considered to be related to the X-ray emission mechanism on the neutron star.
- Open Access
- 25 June 2001
- Published by Oxford University Press (OUP) in Publications of the Astronomical Society of Japan
- Vol. 53 (3) , L9-L12
A 168-s X-Ray Pulsar in the Small Magellanic Cloud Observed with ASCA
We report on the detection of $$167.8 \pm 0.2\,\mathrm{s}$$ pulsations from AX J0052.9$$-$$7157 in the Small Magellanic Cloud with ASCA. The pulsations show an energy-independent sinusoidal profile. The X-ray spectrum has been described by an absorbed hard power-law (photon index $$\sim 0.7$$) with a luminosity of $$\sim 8.8 \times 10^{35}\,\mathrm{erg}\,\mathrm{s}^{-1}$$ at a distance of $$60\,\mathrm{kpc}$$. The position is determined to be $$\mathrm{(R.A.,~Dec.)}_{\mathrm{J2000}} = (00{}^{\mathrm{h}}52{}^{\rm m}59\rlap{.}{}^{\rm s}2, -71{71{}^{\mathrm{\circ}}57{}^{\mathrm{\prime}}58{}^{\mathrm{\prime\prime}}})$$, with an error radius of $$\sim {30{}^{\mathrm{\prime\prime}}}$$. We have found that a variable Be/X-ray binary RX J0052.9$$-$$7158 is located within the $$30{}^{\mathrm{\prime\prime}}$$ error circle, and is also located at the edge of the $$10{}^{\mathrm{\prime}}$$ error circle of the 169-s pulsar XTE J0054$$-$$720. We therefore conclude that these are the same source, a Be/X-ray binary pulsar.- 25 June 2001
- Published by Oxford University Press (OUP) in Publications of the Astronomical Society of Japan
- Vol. 53 (3) , L9-L12
Open AccessA 168-s X-Ray Pulsar in the Small Magellanic Cloud Observed with ASCA
We report on the detection of $$167.8 \pm 0.2\,\mathrm{s}$$ pulsations from AX J0052.9$$-$$7157 in the Small Magellanic Cloud with ASCA. The pulsations show an energy-independent sinusoidal profile. The X-ray spectrum has been described by an absorbed hard power-law (photon index $$\sim 0.7$$) with a luminosity of $$\sim 8.8 \times 10^{35}\,\mathrm{erg}\,\mathrm{s}^{-1}$$ at a distance of $$60\,\mathrm{kpc}$$. The position is determined to be $$\mathrm{(R.A.,~Dec.)}_{\mathrm{J2000}} = (00{}^{\mathrm{h}}52{}^{\rm m}59\rlap{.}{}^{\rm s}2, -71{71{}^{\mathrm{\circ}}57{}^{\mathrm{\prime}}58{}^{\mathrm{\prime\prime}}})$$, with an error radius of $$\sim {30{}^{\mathrm{\prime\prime}}}$$. We have found that a variable Be/X-ray binary RX J0052.9$$-$$7158 is located within the $$30{}^{\mathrm{\prime\prime}}$$ error circle, and is also located at the edge of the $$10{}^{\mathrm{\prime}}$$ error circle of the 169-s pulsar XTE J0054$$-$$720. We therefore conclude that these are the same source, a Be/X-ray binary pulsar. - Open Access
- 25 April 2001
- Published by Oxford University Press (OUP) in Publications of the Astronomical Society of Japan
- Vol. 53 (2) , 227-231
ASCA Identification of SMC X-2 with the 2.37-s Pulsar Discovered by RXTE
ASCA observed a new X-ray pulsar recently discovered with RXTE in the Small Magellanic Cloud, and detected coherent pulsations with a barycentric period of $$2.37230 \pm 0.00004~\mathrm{s}$$. The position is determined within a $$\sim 30{{}^{\mathrm{\prime\prime}}}$$ radius error, which is much more accurate than that reported with RXTE. Since the position error well overlaps a $$\sim 20{{}^{\mathrm{\prime\prime}}}$$ radius error of the SAS-3 transient source SMC X-2, and since the probability that an unrelated source falls in the error region by chance is estimated to be less than 0.1%, we conclude that SMC X-2 is the 2.37-s pulsar. The X-ray spectrum in the 0.7–10.0 keV band can be fitted with a model of a power-law continuum plus a fluorescent line from neutral or low-ionization iron. The pulse profile has a single peak below a few keV and gradually changes to be a double-peaked structure as the energy increases; in particular, the iron line band (6.0–7.0 keV) marginally shows a double-peaked profile similar to that of the higher energy band observed with RXTE.- 25 April 2001
- Published by Oxford University Press (OUP) in Publications of the Astronomical Society of Japan
- Vol. 53 (2) , 227-231
Open AccessASCA Identification of SMC X-2 with the 2.37-s Pulsar Discovered by RXTE
ASCA observed a new X-ray pulsar recently discovered with RXTE in the Small Magellanic Cloud, and detected coherent pulsations with a barycentric period of $$2.37230 \pm 0.00004~\mathrm{s}$$. The position is determined within a $$\sim 30{{}^{\mathrm{\prime\prime}}}$$ radius error, which is much more accurate than that reported with RXTE. Since the position error well overlaps a $$\sim 20{{}^{\mathrm{\prime\prime}}}$$ radius error of the SAS-3 transient source SMC X-2, and since the probability that an unrelated source falls in the error region by chance is estimated to be less than 0.1%, we conclude that SMC X-2 is the 2.37-s pulsar. The X-ray spectrum in the 0.7–10.0 keV band can be fitted with a model of a power-law continuum plus a fluorescent line from neutral or low-ionization iron. The pulse profile has a single peak below a few keV and gradually changes to be a double-peaked structure as the energy increases; in particular, the iron line band (6.0–7.0 keV) marginally shows a double-peaked profile similar to that of the higher energy band observed with RXTE. - Open Access
- 20 September 1999
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 523 (1) , L65-L68
Discovery of 715 Second Pulsations from the Faint X-Ray Source AX J170006−4157
We report here the discovery of a new X-ray pulsator, AX J170006-4157, in the Galactic plane. The source was observed three times between 1994 and 1997 by the Advanced Satellite for Cosmology and Astrophysics. Significant pulsations with P = 714.5 ± 0.3 s were discovered from the third observation made between MJD 50,707.8926 and MJD 50,710.2199. The X-ray spectrum is described by a flat power-law function with a photon index of 0.7. Although the spectrum could also be fitted by thermal models, the temperature obtained was unphysically high. The hard spectrum suggests that the source is a neutron star binary pulsar similar to X Persei (4U 0352+309), but we cannot completely exclude the possibility that it is a white dwarf binary.
- 20 September 1999
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 523 (1) , L65-L68
Open AccessDiscovery of 715 Second Pulsations from the Faint X-Ray Source AX J170006−4157
We report here the discovery of a new X-ray pulsator, AX J170006-4157, in the Galactic plane. The source was observed three times between 1994 and 1997 by the Advanced Satellite for Cosmology and Astrophysics. Significant pulsations with P = 714.5 ± 0.3 s were discovered from the third observation made between MJD 50,707.8926 and MJD 50,710.2199. The X-ray spectrum is described by a flat power-law function with a photon index of 0.7. Although the spectrum could also be fitted by thermal models, the temperature obtained was unphysically high. The hard spectrum suggests that the source is a neutron star binary pulsar similar to X Persei (4U 0352+309), but we cannot completely exclude the possibility that it is a white dwarf binary.
- Open Access
- 1 December 1998
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 508 (2) , 854-858
Discovery of a 220 Second X‐Ray Pulsar, AX J1749.2−2725
We report here the discovery of a faint 220 s X-ray pulsar, AX J1749.2-2725, with ASCA. In the analysis, we used a method that can detect a pulsating source in a field of view contaminated by stray light. The source was observed on four occasions between 1995 March and 1997 September. The observed source flux was ~3.0 × 10-11 ergs s-1 cm-2 (2-10 keV) in 1995 March and became an order of magnitude fainter during the 2.5 yr interval. We cannot rule out the possibility that AX J1749.2-2725 is a nearby (d 1.3 kpc) DQ Her-type white dwarf binary, while the hard X-ray spectrum and the transient behavior suggest that it is a distant (d ~ 8.5 kpc) binary system containing a neutron star.
- 1 December 1998
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 508 (2) , 854-858
Open AccessDiscovery of a 220 Second X‐Ray Pulsar, AX J1749.2−2725
We report here the discovery of a faint 220 s X-ray pulsar, AX J1749.2-2725, with ASCA. In the analysis, we used a method that can detect a pulsating source in a field of view contaminated by stray light. The source was observed on four occasions between 1995 March and 1997 September. The observed source flux was ~3.0 × 10-11 ergs s-1 cm-2 (2-10 keV) in 1995 March and became an order of magnitude fainter during the 2.5 yr interval. We cannot rule out the possibility that AX J1749.2-2725 is a nearby (d 1.3 kpc) DQ Her-type white dwarf binary, while the hard X-ray spectrum and the transient behavior suggest that it is a distant (d ~ 8.5 kpc) binary system containing a neutron star.