BDBarney Lee Doyle

Barney Lee Doyle

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Barney Lee Doyle has a total of 68 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Measurement and Simulation of Ultra-Low-Energy Ion–Solid Interaction Dynamics

    by Michael Titze, Jonathan D. Poplawsky, Silvan Kretschmer, Arkady V. Krasheninnikov, Barney L. Doyle, Edward S. Bielejec, Gerhard Hobler, Alex Belianinov

    Ion implantation is a key capability for the semiconductor industry. As devices shrink, novel materials enter the manufacturing line, and quantum technologies transition to being more mainstream. Traditional implantation methods fall short in terms of energy, ion species, and positional precision. Here, we demonstrate 1 keV focused ion beam Au implantation into Si and validate the results via atom probe tomography. We show the Au implant depth at 1 keV is 0.8 nm and that identical results for low-energy ion implants can be achieved by either lowering the column voltage or decelerating ions using bias while maintaining a sub-micron beam focus. We compare our experimental results to static calculations using SRIM and dynamic calculations using binary collision approximation codes TRIDYN and IMSIL. A large discrepancy between the static and dynamic simulation is found, which is due to lattice enrichment with high-stopping-power Au and surface sputtering. Additionally, we demonstrate how model details are particularly important to the simulation of these low-energy heavy-ion implantations. Finally, we discuss how our results pave a way towards much lower implantation energies while maintaining high spatial resolution.


  • Transient Photocurrent From High-Voltage Vertical GaN Diodes Irradiated With Electrons: Experiments and Simulations

    by S. D. Koukourinkova, A. Colon, B. L. Doyle, G. Vizkelethy, G. W. Pickrell, B. P. Gunning, K. E. Kropka, E. S. Bielejec, W. R. Wampler

    Radiation-hard high-voltage vertical GaN p-n diodes are being developed for use in power electronics subjected to ionizing radiation. We present a comparison of the measured and simulated photocurrent response of diodes exposed to ionizing irradiation with 70 keV and 20 MeV electrons at dose rates in the range of 1.4x10 7 - 5.0x10 8 rad(GaN)/s. The simulations correctly predict the trend in measured steady-state photocurrent and agree with experimental results within a factor of 2. Furthermore, simulations of the transient photocurrent response to dose rates with uniform and non-uniform ionization depth profiles uncover the physical processes involved that cannot be otherwise experimentally observed due to orders of magnitude larger RC time constant of the test circuit. The simulations were performed using an Exploratory Physics Development code developed at Sandia National Laboratories. The code offers the capability to include defect physics under more general conditions, not included in commercially available software packages, extending the applicability of the simulations to different types of radiation environments.


  • Open Access

    In Situ TEM Multi-Beam Ion Irradiation as a Technique for Elucidating Synergistic Radiation Effects

    by Caitlin Anne Taylor, Daniel Charles Bufford, Brittany Rana Muntifering, David Senor, Mackenzie Steckbeck, Justin Davis, Barney Doyle, Daniel Buller, Khalid Mikhiel Hattar

    Materials designed for nuclear reactors undergo microstructural changes resulting from a combination of several environmental factors, including neutron irradiation damage, gas accumulation and elevated temperatures. Typical ion beam irradiation experiments designed for simulating a neutron irradiation environment involve irradiating the sample with a single ion beam and subsequent characterization of the resulting microstructure, often by transmission electron microscopy (TEM). This method does not allow for examination of microstructural effects due to simultaneous gas accumulation and displacement cascade damage, which occurs in a reactor. Sandia’s in situ ion irradiation TEM (I3TEM) offers the unique ability to observe microstructural changes due to irradiation damage caused by concurrent multi-beam ion irradiation in real time. This allows for time-dependent microstructure analysis. A plethora of additional in situ stages can be coupled with these experiments, e.g., for more accurately simulating defect kinetics at elevated reactor temperatures. This work outlines experiments showing synergistic effects in Au using in situ ion irradiation with various combinations of helium, deuterium and Au ions, as well as some initial work on materials utilized in tritium-producing burnable absorber rods (TPBARs): zirconium alloys and LiAlO2.


  • Tomographic Back-Projection Algorithm for “Incomplete” Compton X-Rays Detectors

    by Cristiano Lino Fontana, Giuseppe Baldazzi, Andrea Battistella, Michele Bello, Dante Bollini, Marcello Galli, Giuliano Moschini, Gianluigi Zampa, Nicola Zampa, Paolo Rossi, et al.

    A “Compton” detector finds the direction of an X‐ray by letting it interact with a gaseous, liquid or thin solid material (Tracker) and employing no collimators. This paper takes into account the case of an “incomplete” solid Tracker where the recoiling electron travels only a few dozen microns and cannot be followed. However, impact positions and incoming and outgoing energies are measured. In this situation, exploiting the Compton Scattering formula, one is only able to identify a cone whose surface the X‐ray belongs to. On the other hand, Compton tomography luckily requires only a few views (for example rotating the apparatus in just four positions around the subject), as the “electronic collimation” that takes place in each position already extracts X‐rays coming from many directions. A back‐projection algorithm that combines the reconstructed “cones” in space, weighed according to the Klein‐Nishina formula, has been applied to the special case of small animal SPECT(Single Photon Emission Computed Tomography). Here the source is close to the detector, every imaged point in space is calculated from many rays that are emitted at different angles, and the algorithm totally differs from that of the Compton imaging in Astronomy. Tomography reconstruction has been validated by employing simulated data, generated using GEANT4 that includes the Doppler Broadening in the energies of scattered photons, which is due to moving non‐free electrons. Space resolution has been assessed.

  • Radiation microscope for SEE testing using GeV ions.

    by Barney Lee Doyle, James Arthur Knapp, Paolo Rossi, Khalid M. Hattar, Gyorgy Vizkelethy, David Kenneth Brice, Janelle V. Branson

    Radiation Effects Microscopy is an extremely useful technique in failure analysis of electronic parts used in radiation environment. It also provides much needed support for development of radiation hard components used in spacecraft and nuclear weapons. As the IC manufacturing technology progresses, more and more overlayers are used; therefore, the sensitive region of the part is getting farther and farther from the surface. The thickness of these overlayers is so large today that the traditional microbeams, which are used for REM are unable to reach the sensitive regions. As a result, higher ion beam energies have to be used (> GeV), which are available only at cyclotrons. Since it is extremely complicated to focus these GeV ion beams, a new method has to be developed to perform REM at cyclotrons. We developed a new technique, Ion Photon Emission Microscopy, where instead of focusing the ion beam we use secondary photons emitted from a fluorescence layer on top of the devices being tested to determine the position of the ion hit. By recording this position information in coincidence with an SEE signal we will be able to indentify radiation sensitive regions of modern electronic parts, which will increase the efficiency ofmore » radiation hard circuits.« less

  • Particulate characterization by PIXE multivariate spectral analysis

    by Arlyn J. Antolak, Daniel H. Morse, Patrick G. Grant, Paul G. Kotula, Barney L. Doyle, Charles B. Richardson


  • Simulation of neutron displacement damage in bipolar junction transistors using high-energy heavy ion beams.

    by Barney Lee Doyle, Daniel L. Buller, Harold Paul Hjalmarson, Robert M Fleming, Edward Salvador Bielejec, Gyorgy Vizkelethy

    Electronic components such as bipolar junction transistors (BJTs) are damaged when they are exposed to radiation and, as a result, their performance can significantly degrade. In certain environments the radiation consists of short, high flux pulses of neutrons. Electronics components have traditionally been tested against short neutron pulses in pulsed nuclear reactors. These reactors are becoming less and less available; many of them were shut down permanently in the past few years. Therefore, new methods using radiation sources other than pulsed nuclear reactors needed to be developed. Neutrons affect semiconductors such as Si by causing atomic displacements of Si atoms. The recoiled Si atom creates a collision cascade which leads to displacements in Si. Since heavy ions create similar cascades in Si we can use them to create similar damage to what neutrons create. This LDRD successfully developed a new technique using easily available particle accelerators to provide an alternative to pulsed nuclear reactors to study the displacement damage and subsequent transient annealing that occurs in various transistor devices and potentially qualify them against radiation effects caused by pulsed neutrons.


  • An annular Si drift detector µPIXE system using AXSIA analysis

    by B. L. Doyle, D. S. Walsh, P. G. Kotula, P. Rossi, T. Schülein, M. Rohde

    Sandia and Rontec have developed an annular, 12‐element, 60 mm 2 , Peltier‐cooled, translatable, silicon drift detector called the SDD‐12. The body of the SDD‐12 is only 22.8 mm in total thickness and easily fits between the sample and the upstream wall of the Sandia microbeam chamber. At a working distance of 1 mm, the solid angle is 1.09 sr. The energy resolution is 170 eV at count rates <40 kcps and 200 eV for rates of 1 Mcps. X‐ray count rates must be maintained below 50 kcps when protons are allowed to strike the full area of the SDD. Another innovation with this new µPIXE system is that the data are analyzed using Sandia's Automated eXpert Spectral Image Analysis (AXSIA). Copyright © 2005 John Wiley & Sons, Ltd.


  • Direct single ion machining of nanopores.

    by Barney Lee Doyle, David Martin Follstaedt, Paolo Rossi, Adam K Norman

    The irradiation of thin insulating films by high-energy ions (374 MeV Au{sup +25} or 241 MeV I{sup +19}) was used to attempt to form nanometer-size pores through the films spontaneously. Such ions deposit a large amount of energy into the target materials ({approx}20 keV/nm), which significantly disrupts their atomic lattice and sputters material from the surfaces, and might produce nanopores for appropriate ion-material combinations. Transmission electron microscopy was used to examine the resulting ion tracks. Tracks were found in the crystalline oxides quartz, sapphire, and mica. Sapphire and mica showed ion tracks that are likely amorphous and exhibit pits 5 nm in diameter on the surface at the ion entrance and exit points. This suggests that nanopores might form in mica if the film thickness is less than {approx}10 nm. Tracks in quartz showed strain in the matrix around them. Tracks were not found in the amorphous thin films examined: 20 nm-SiN{sub x}, deposited SiOx, fused quartz (amorphous SiO{sub 2}), formvar and 3 nm-C. Other promising materials for nanopore formation were identified, including thin Au and SnO{sub 2} layers.