GSGlenn S. Slavin

Glenn S. Slavin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Glenn S. Slavin has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Addressing efficiency and residual magnetization cross talk in multi-slice 2D steady-state free precession imaging of the heart

    by Glenn S. Slavin, Dan W. Rettmann

    This work presents an efficient method for achieving steady state in multi‐slice 2D balanced steady‐state free precession (SSFP) imaging of cardiac function. With current techniques, data acquisition for each slice is preceded by one or two heartbeats of dummy excitations. Depending on the number of heartbeats required for data acquisition, these dummy heartbeats can represent a large fraction of the total imaging time. As described here, FIESTA‐SP (FIESTA with steady‐state preparation) increases the imaging efficiency to nearly 100% by eliminating dummy heartbeats. Steady state for each slice is achieved using a linear flip angle series of excitations during the first cardiac phase of the first heartbeat for each slice. Because imaging proceeds immediately from one slice to the next, a heretofore‐unseen issue arises where residual magnetization from each slice contaminates subsequent acquisitions. Accelerating the approach to steady state for each slice and eliminating slice cross talk are important for both multi‐slice and interactive real‐time imaging. Magn Reson Med 53:965–969, 2005.


  • Open Access

    FIESTA‐ET: High‐resolution cardiac imaging using echo‐planar steady‐state free precession

    by Glenn S. Slavin, Manojkumar Saranathan

    This work describes a technique that combines multishot echo‐planar imaging (EPI) with steady‐state free precession (SSFP, also known as TrueFISP, FIESTA, and balanced FFE) for multislice, cine MR imaging of the heart. Unlike recently reported methods, the technique presented here (FIESTA‐ET) is high‐resolution and does not require offline reconstruction or postprocessing. It is therefore suitable for use on standard clinical scanners. FIESTA‐ET was compared with conventional FIESTA imaging in 10 volunteers and quantitative analyses of myocardial signal‐to‐noise ratios (SNR) and ventricular volumes were performed. While providing comparable image quality, FIESTA‐ET required half the acquisition time per slice of conventional FIESTA. Because multiple slices could be imaged in a single breathhold, the entire heart could be scanned in less than 2 min. Although the FIESTA‐ET images exhibited an unexpected increase (P < 0.0005) in myocardial SNR of 16% over FIESTA, the volumetric measurements showed excellent correlation. Magn Reson Med 48:934–941, 2002.


  • First-Pass Myocardial Perfusion MR Imaging with Interleaved Notched Saturation: Feasibility Study

    by Glenn S. Slavin, Steven D. Wolff, Sandeep N. Gupta, Thomas K. F. Foo

    The authors evaluated a magnetization preparation scheme with a "notched" section profile for T1-weighted first-pass myocardial perfusion magnetic resonance (MR) imaging at 1.5 T. The pulse sequence consisted of a preparation sequence followed by an interleaved gradient-echo echo-planar sequence. Image contrast was evaluated in a feasibility study in 12 adult patients. The notched saturation pulse allowed long magnetization recovery times without sacrificing section coverage. Image contrast between normal and ischemic myocardium was excellent.