JHJonny Hansson

Jonny Hansson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jonny Hansson has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Magnus Båth

    University of Gothenburg, Sahlgrenska Academy, Institute of Clinical Sciences, Department of Medical Radiation Sciences, Gothenburg, Sweden

    3 shared publications
  • Lars Gunnar Månsson

    Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, SE-413 45 Gothenburg, Sweden Department of Radiation Physics, Institute of Clinical Sciences, the Sahlgrenska Academy at University of Gothenburg, SE-413 45 Gothenburg, Sweden

    2 shared publications
  • Anne Thilander-Klang

    Department of Medical Physics and Biomedical Engineering , Sahlgrenska University Hospital, Gothenburg , Sweden 2 Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy , University of Gothenburg, SE-413 45 Gothenburg , Sweden

    1 shared publication
  • Annette Kjellström

    1 shared publication
  • Elisabeth Bjurklint

    1 shared publication
  • Håkan Boström

    1 shared publication

Latest Publications

  • THE VALIDITY OF USING ROC SOFTWARE FOR ANALYSING VISUAL GRADING CHARACTERISTICS DATA: AN INVESTIGATION BASED ON THE NOVEL SOFTWARE VGC ANALYZER

    by Jonny Hansson, Lars Gunnar Månsson, Magnus Båth

    The purpose of the present work was to investigate the validity of using single-reader-adapted receiver operating characteristics (ROC) software for analysis of visual grading characteristics (VGC) data. VGC data from four published VGC studies on optimisation of X-ray examinations, previously analysed using ROCFIT, were reanalysed using a recently developed software dedicated to VGC analysis (VGC Analyzer), and the outcomes [the mean and 95 % confidence interval (CI) of the area under the VGC curve (AUCVGC) and the p-value] were compared. The studies included both paired and non-paired data and were reanalysed both for the fixed-reader and the random-reader situations. The results showed good agreement between the softwares for the mean AUCVGC. For non-paired data, wider CIs were obtained with VGC Analyzer than previously reported, whereas for paired data, the previously reported CIs were similar or even broader. Similar observations were made for the p-values. The results indicate that the use of single-reader-adapted ROC software such as ROCFIT for analysing non-paired VGC data may lead to an increased risk of committing Type I errors, especially in the random-reader situation. On the other hand, the use of ROC software for analysis of paired VGC data may lead to an increased risk of committing Type II errors, especially in the fixed-reader situation.


  • Comparison of three methods for determining CT dose profile: presenting the tritium method

    by Jonny Hansson, Simone Eriksson, Anne Thilander-Klang, Magnus Båth

    The purpose of the present work was to describe a method of using an imaging plate from a computed radiography system to determine the computed tomography (CT) dose profile (the tritium method) and to compare this method with point-dose measurements using a solid-state detector (CT Dose Profiler; RTI Electronics, Mölndal, Sweden) and the indirect method of comparing the air kerma-length product (PKL) at different beam collimations. The three methods were used to determine the full width at half maximum (FWHM) of the dose profile of a multi-slice CT at different nominal beam collimations. For all beam collimations, the obtained deviation between the tritium method and the CT Dose Profiler was smaller than 0.1 mm. The maximum relative error was 2 %. For the PKL method, the deviation from the CT Dose Profiler was between 0.2 and 0.4 mm, resulting in a relative error larger than 10 % for the smallest beam collimation even after normalisation to a known FWHM. In conclusion, the proposed method of using an imaging plate to determine the FWHM of the CT dose profile has a high accuracy and shows good agreement with the more advanced method of point-dose measurements using a solid-state detector.


  • A practical approach to prioritise among optimisation tasks in X-ray imaging: introducing the 4-bit concept

    by Jonny Hansson, Patrik Sund, Pernilla Jonasson, Lars Gunnar MÅNsson, Magnus BÅTh

    According to European and national legislation, as well as international recommendations, X-ray examinations shall be optimised. However, with limited resources and hundreds of different types of X-ray examinations, it may be difficult to prioritise among the optimisation tasks at a radiology department. This work is focused on describing a method that can be used to determine the order of which the examinations should be optimised. In the Medical Exposure Directive from 1997, the European Commission prescribes the content of an optimisation process in relation to medical exposure. A reasonable interpretation of the directive is that the assurance of medical purpose for a justified examination is superior to the need of decreased radiation dose. This was used as a basis for developing a method for prioritisation among optimisation tasks. For each examination type, the following four yes/no questions are raised: (i) Is the present image quality unacceptable? (ii) Is the examination of particular importance? (iii) Is the radiation dose suspiciously high? (iv) Are there special dose level concerns, e.g. diagnostic reference levels? Arguing that a positive response to any of the four questions results in the examination being higher prioritised than otherwise and that the questions are labelled in order of decreasing relevance, it can be shown that the resulting flow chart, determining the order of which the examinations should be optimised, can be described by a 4-bit binary scale. In this way, each examination type is given a number from 0 to 15, a higher number corresponding to the examination being prioritised higher in the optimisation work. The method was applied to a general radiology department and resulted in a well-discriminated distribution of examinations prioritised for optimisation tasks. In conclusion, taking into account both medical outcome and potential risk, the proposed method can be used to determine the order in which examinations at a radiology department should be optimised.


  • An optimisation strategy in a digital environment applied to neonatal chest imaging

    by Jonny Hansson, Magnus Båth, Markus Håkansson, Håkan Grundin, Elisabeth Bjurklint, Pia Orvestad, Annette Kjellström, Håkan Boström, Mats Jönsson, Kenneth Jonsson, et al.

    The aim of this study was to find the optimum tube voltage for neonatal chest imaging in computed radiography. The study was designed to take full advantage of the benefits of digital imaging, for example, by comparing the tube voltages at constant effective dose. A phantom study using a living rabbit was first conducted. Images were collected at tube voltages ranging from 40 to 90 kVp. The reproduction of four structures (central vessels, peripheral vessels, carina and thoracic vertebrae) was rated by 10 radiologists. The reproduction of both central and peripheral vessels was relatively independent of tube voltage. The carina was better reproduced at higher tube voltages whereas the opposite was true for the thoracic vertebrae. Based on the higher importance of the reproduction of the carina it was decided that 90 kVp was the optimal tube voltage. To validate the result from the phantom study, a follow-up study was conducted in which images of neonates collected at the tube voltage regularly used at Sahlgrenska University Hospital (70 kVp) were compared with images collected at the tube voltage proposed by the phantom study. The follow-up study confirmed the results from the phantom study that the reproduction of the carina was better at 90 than at 70 kVp. In conclusion, for neonatal chest imaging—given the same effective dose—90 kVp gives better reproduction of important structures than the regularly used 70 kVp.