YWYi Wang

Yi Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yi Wang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Khurram Moin

    Department of Biomedical Engineering, SUNY at Stony Brook, Stony Brook, New York, USA

    2 shared publications
  • Nathaniel Reichek

    Department of Biomedical Engineering, SUNY at Stony Brook, Stony Brook, New York, USA

    2 shared publications
  • Olakunle Akinboboye

    Department of Biomedical Engineering, SUNY at Stony Brook, Stony Brook, New York, USA

    2 shared publications
  • Sunil T. Mathew

    Research and Education Department, St. Francis Hospital, Roslyn, New York, USA

    1 shared publication

Latest Publications

  • Open Access

    Myocardial first pass perfusion: Steady‐state free precession versus spoiled gradient echo and segmented echo planar imaging

    by Yi Wang, Khurram Moin, Olakunle Akinboboye, Nathaniel Reichek

    The imaging sequences used in first pass (FP) perfusion to date have important limitations in contrast‐to‐noise ratio (CNR), temporal and spatial resolution, and myocardial coverage. As a result, controversy exists about optimal imaging strategies for FP myocardial perfusion. Since imaging performance varies from subject to subject, it is difficult to form conclusions without direct comparison of different sequences in the same subject. The purpose of this study was to directly compare the saturation recovery SSFP technique to other more commonly used myocardial first pass perfusion techniques, namely spoiled GRE and segmented EPI. Differences in signal‐to‐noise ratio (SNR), CNR, relative maximal upslope (RMU) of signal amplitude, and artifacts at comparable temporal and spatial resolution among the three sequences were investigated in computer simulation, contrast agent doped phantoms, and 16 volunteers. The results demonstrate that SSFP perfusion images exhibit an improvement of approximately 77% in SNR and 23% in CNR over spoiled GRE and 85% SNR and 50% CNR over segmented EPI. Mean RMU was similar between SSFP and spoiled GRE, but there was a 58% increase in RMU with SSFP versus segmented EPI. Magn Reson Med, 2005.


  • Myocardial first‐pass perfusion assessment using rotational long‐axis MRI

    by Yi Wang, Khurram Moin, Sunil T. Mathew, Olakunle Akinboboye, Nathaniel Reichek

    Purpose To study a first‐pass myocardial perfusion imaging method, such that long‐axis imaging slices are obtained rotationally around the short‐axis centroid of the left ventricular cavity, in order to improve myocardial coverage and better delineate the basal and apical myocardium. Materials and Methods This rotational long‐axis (RLA) method was examined in 12 volunteers and compared to the perfusion images from conventional parallel short‐axis (PSA) acquisitions in terms of the contrast to noise ratio (CNR), relative signal upslope and myocardial coverage. Both RLA and PSA first‐pass perfusion images were acquired on each volunteer with otherwise identical imaging parameters using the partial Fourier saturation recovery steady state gradient echo sequence with refocused magnetization (TrueFISP) technique. Results Compared to PSA, RLA perfusion images with identical imaging parameters on the same subject exhibit an average of near 30% improvement in total myocardial area imaged. In addition, true basal and apical myocardium was seen on RLA, but not on PSA. The mean CNR and relative upslope were similar between the two techniques. Conclusions This RLA perfusion imaging scheme is superior to the conventional PSA approach in terms of extent myocardial coverage and delineation of basal and apical regions of the left ventricle. J. Magn. Reson. Imaging 2005;22:53–58.