Hitoshi Mukohyama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hitoshi Mukohyama has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Hisashi Taniguchi
6 shared publicationsShogo Ozawa
2 shared publicationsTakashi Ohyama
2 shared publicationsAkihiko Watanabe
1 shared publicationChiaki Kadota
1 shared publicationDavid J Reisberg
1 shared publication
Latest Publications
- 23 June 2005
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 32 (7) , 541-544
Rehabilitation of a bilateral maxillectomy patient with a free fibula osteocutaneous flap*
summary Rehabilitation of patients who have undergone bilateral maxillectomy is difficult because of extensive loss of bone and soft tissue. In this clinical report, prosthodontic rehabilitation of oral function in a bilateral maxillecitomy patient combined with a new fibular osteocutaneous flap, which was designed to have two oronasal slits for the retention of an obturator prosthesis, was described. A 58‐year‐old man with a maxillary alveolar carcinoma underwent bilateral maxillectomy. The defect was reconstructed using a vascularized fibular bone wrapped circumferentially with a peroneal flap, which was fixed with miniplates between the right malar prominence and cut edge of the left zygoma remaining two slits anterior and posterior to the graft. Two and half weeks after the surgery, a delayed surgical obturator was delivered and an obturator prosthesis was delivered 6 weeks after the surgery. This obturator prosthesis could be extended into the slits to engage the tissue undercuts, and was stable during use. Mastication, deglutition, articulation and the mid‐facial profile of the patient were rehabilitated. After installation of the obturator prosthesis, relining of the prosthesis base was carried out alongside the healing process of the graft, and adjustment of occlusions and high‐pressure spots was carried out. No clinical disorders were observed either in the grafted tissue or the obturator prosthesis with a 3‐year prognosis. Newly designing a fibular osteocutaneous flap combined with tissue‐borne obturator prosthesis is one successful approach to the restoration of oral function, and increases the patient's quality of life after bilateral maxillectomy.
- 23 June 2005
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 32 (7) , 541-544
Rehabilitation of a bilateral maxillectomy patient with a free fibula osteocutaneous flap*
summary Rehabilitation of patients who have undergone bilateral maxillectomy is difficult because of extensive loss of bone and soft tissue. In this clinical report, prosthodontic rehabilitation of oral function in a bilateral maxillecitomy patient combined with a new fibular osteocutaneous flap, which was designed to have two oronasal slits for the retention of an obturator prosthesis, was described. A 58‐year‐old man with a maxillary alveolar carcinoma underwent bilateral maxillectomy. The defect was reconstructed using a vascularized fibular bone wrapped circumferentially with a peroneal flap, which was fixed with miniplates between the right malar prominence and cut edge of the left zygoma remaining two slits anterior and posterior to the graft. Two and half weeks after the surgery, a delayed surgical obturator was delivered and an obturator prosthesis was delivered 6 weeks after the surgery. This obturator prosthesis could be extended into the slits to engage the tissue undercuts, and was stable during use. Mastication, deglutition, articulation and the mid‐facial profile of the patient were rehabilitated. After installation of the obturator prosthesis, relining of the prosthesis base was carried out alongside the healing process of the graft, and adjustment of occlusions and high‐pressure spots was carried out. No clinical disorders were observed either in the grafted tissue or the obturator prosthesis with a 3‐year prognosis. Newly designing a fibular osteocutaneous flap combined with tissue‐borne obturator prosthesis is one successful approach to the restoration of oral function, and increases the patient's quality of life after bilateral maxillectomy.
- 9 July 2004
- Vol. 17 (3) , 345-9
Innovative gas injection technique for closed-hollow obturator.
The purpose of this study was to determine the proper prerequisite conditions for gas injection and the steps for applying gas injection for obturator fabrication. Optimal prerequisite conditions were investigated by using thermocoupling to verify exothermic changes in the resin during polymerization. Three experimental groups were designated: in the control group (C), resin was packed into the mold without argon gas injection; in the gas injection group (GI), after resin packing, gas was injected into the resin bulb in the mold; and in the plunger/gas injection group (PGI), after resin packing, the syringe plunger was drawn out before gas injection. The 55 degrees C mold temperature and addition of 0.3% DMPT to the monomer liquid caused differences in exothermic temperature increase in various parts of the resin. Without gas injection and plunger drawing, porosity was observed in the thick bulbs of groups C and PGI. In group PGI, a balloon-like elliptic hollow was observed. Compared to group C, the weight reduction in group PGI was approximately 10%. Proper mold temperature with secondary venting and the addition of DMPT were required before the injection of gas. The resulting prosthesis could be fabricated in one step and required no resin seal.
- 9 July 2004
- Vol. 17 (3) , 345-9
Innovative gas injection technique for closed-hollow obturator.
The purpose of this study was to determine the proper prerequisite conditions for gas injection and the steps for applying gas injection for obturator fabrication. Optimal prerequisite conditions were investigated by using thermocoupling to verify exothermic changes in the resin during polymerization. Three experimental groups were designated: in the control group (C), resin was packed into the mold without argon gas injection; in the gas injection group (GI), after resin packing, gas was injected into the resin bulb in the mold; and in the plunger/gas injection group (PGI), after resin packing, the syringe plunger was drawn out before gas injection. The 55 degrees C mold temperature and addition of 0.3% DMPT to the monomer liquid caused differences in exothermic temperature increase in various parts of the resin. Without gas injection and plunger drawing, porosity was observed in the thick bulbs of groups C and PGI. In group PGI, a balloon-like elliptic hollow was observed. Compared to group C, the weight reduction in group PGI was approximately 10%. Proper mold temperature with secondary venting and the addition of DMPT were required before the injection of gas. The resulting prosthesis could be fabricated in one step and required no resin seal.
- 1 July 2004
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 92 (1) , 23-26
Lip plumper prosthesis for a patient with a marginal mandibulectomy: a clinical report
- 1 July 2004
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 92 (1) , 23-26
Lip plumper prosthesis for a patient with a marginal mandibulectomy: a clinical report
- 1 June 2004
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 91 (6) , 518-520
Chairside modification of a surgical obturator: A clinical report
- 1 June 2004
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 91 (6) , 518-520
Chairside modification of a surgical obturator: A clinical report
- 1 March 2004
- Vol. 51 (1) , 19-25
The pattern of tongue pressure against the palate during articulating glossal sounds in normal subjects and glossectomy patients.
The purpose of the present study was to measure tongue pressure with the aim of characterizing the pattern of linguopalatal contact during articulating glossal sounds in normal subjects and glossectomy patients. Tongue pressures against the palate were evaluated in 13 normal subjects and 5 glossectomy patients by using three parameters: the duration from the onset of linguopalatal contact to the time of maximum pressure, the maximum pressure, and anterior posterior ratio of the maximum pressure. Three glossal sounds, [ti], [t [symbol: see text] i], and [[symbol: see text] i], which have tendency of mishearing in glossectomy patients, were selected for test sounds. A unique characteristic was demonstrated in normal subjects. The score of the maximum pressure showed an apparent order among the three sounds, while the durations revealed the opposite order. Anterior posterior ratio of the maximum pressure also showed some relationship among three sounds. In glossectomy patients, these characters were not found. The loss of tongue volume or deterioration of tongue mobility causes these results.
- 1 March 2004
- Vol. 51 (1) , 19-25
The pattern of tongue pressure against the palate during articulating glossal sounds in normal subjects and glossectomy patients.
The purpose of the present study was to measure tongue pressure with the aim of characterizing the pattern of linguopalatal contact during articulating glossal sounds in normal subjects and glossectomy patients. Tongue pressures against the palate were evaluated in 13 normal subjects and 5 glossectomy patients by using three parameters: the duration from the onset of linguopalatal contact to the time of maximum pressure, the maximum pressure, and anterior posterior ratio of the maximum pressure. Three glossal sounds, [ti], [t [symbol: see text] i], and [[symbol: see text] i], which have tendency of mishearing in glossectomy patients, were selected for test sounds. A unique characteristic was demonstrated in normal subjects. The score of the maximum pressure showed an apparent order among the three sounds, while the durations revealed the opposite order. Anterior posterior ratio of the maximum pressure also showed some relationship among three sounds. In glossectomy patients, these characters were not found. The loss of tongue volume or deterioration of tongue mobility causes these results.
- 1 December 2003
- Vol. 50 (4) , 257-64
Electromyographic activity of masticatory muscles and mandibular movement during function in marginal mandibulectomy patients.
The purpose of this study is to evaluate the masticatory muscle activity and mandibular movement during function in marginal mandibulectomy patients. Three marginal mandibulectomy patients and three healthy subjects participated in this study. The activities of the temporalis (TA) and masseter muscles (MM) on the normal and resected sides during maximum voluntary clenching (MVC) and gum chewing (Gch), and mandibular movement during Gch were analyzed. Paired t-test, Student's t-test and one-way ANOVA were performed at P < 0.05. For MVC, integrated EMG (iEMG) in patients was lower than in healthy subjects. When iEMG of each muscle activity in patients was compared, TA activity on the resected side was greater than that of MM. There were no differences between the normal and resected sides in TA or MM. For Gch, no differences in iEMG, burst or chewing time were found between patients and healthy subjects. MVC was greater than Gch in healthy subjects, but no difference was found in patients. The range of mandibular movement along the X axis in patients was greater than in healthy subjects. Within the limitations of this study, EMG activity in patients during MVC was remarkably lower than that in healthy subjects, and altered mandibular movement was observed.
- 1 December 2003
- Vol. 50 (4) , 257-64
Electromyographic activity of masticatory muscles and mandibular movement during function in marginal mandibulectomy patients.
The purpose of this study is to evaluate the masticatory muscle activity and mandibular movement during function in marginal mandibulectomy patients. Three marginal mandibulectomy patients and three healthy subjects participated in this study. The activities of the temporalis (TA) and masseter muscles (MM) on the normal and resected sides during maximum voluntary clenching (MVC) and gum chewing (Gch), and mandibular movement during Gch were analyzed. Paired t-test, Student's t-test and one-way ANOVA were performed at P < 0.05. For MVC, integrated EMG (iEMG) in patients was lower than in healthy subjects. When iEMG of each muscle activity in patients was compared, TA activity on the resected side was greater than that of MM. There were no differences between the normal and resected sides in TA or MM. For Gch, no differences in iEMG, burst or chewing time were found between patients and healthy subjects. MVC was greater than Gch in healthy subjects, but no difference was found in patients. The range of mandibular movement along the X axis in patients was greater than in healthy subjects. Within the limitations of this study, EMG activity in patients during MVC was remarkably lower than that in healthy subjects, and altered mandibular movement was observed.
- 1 December 2002
- Vol. 49 (4) , 121-8
Vibration analysis of obturator prostheses with different bulb height designs.
The purpose of this study was to investigate the effect on the vibratory characteristics of a cast hollow obturator prosthesis retainer when varying its bulb height. Bulb parts with high (H), middle (M), and low (L) lateral walls were prepared. A Vibration Generator was used to excite the three obturators, while a Laser-Doppler Vibrometer was employed to detect the vibrations at specified measurement points. The frequency response functions of each obturator were recorded on an FFT analyzer to enable their modal shapes to be identified. In addition, transient response simulations were carried out and the decay rate (DR) and the maximum amplitude (MA) of the rest and clasp parts of each obturator were obtained. These were statistically analyzed by ANOVA and Fisher's PLSD test (p < 0.01). The modal shapes were almost the same in all obturators. Significant differences were found in DR in all pairs among the three obturator prostheses, with the DR of the L type being the highest. On the other hand, there were no significant differences in MA. We conclude that the L type is preferable from the standpoint of its vibratory characteristics.
- 1 December 2002
- Vol. 49 (4) , 121-8
Vibration analysis of obturator prostheses with different bulb height designs.
The purpose of this study was to investigate the effect on the vibratory characteristics of a cast hollow obturator prosthesis retainer when varying its bulb height. Bulb parts with high (H), middle (M), and low (L) lateral walls were prepared. A Vibration Generator was used to excite the three obturators, while a Laser-Doppler Vibrometer was employed to detect the vibrations at specified measurement points. The frequency response functions of each obturator were recorded on an FFT analyzer to enable their modal shapes to be identified. In addition, transient response simulations were carried out and the decay rate (DR) and the maximum amplitude (MA) of the rest and clasp parts of each obturator were obtained. These were statistically analyzed by ANOVA and Fisher's PLSD test (p < 0.01). The modal shapes were almost the same in all obturators. Significant differences were found in DR in all pairs among the three obturator prostheses, with the DR of the L type being the highest. On the other hand, there were no significant differences in MA. We conclude that the L type is preferable from the standpoint of its vibratory characteristics.