Anne Bahr
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Anne Bahr has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Ashley B. Saunders
Department of Small Animal Clinical Sciences, College of Veterinary Medicine and Biomedical Sciences, Texas A&M University, College Station, TX
1 shared publication Matthew Miller
Department of Small Animal Medicine and Surgery, College of Veterinary Medicine, Texas A&M University, College Station, TX
1 shared publicationMatthew W. Miller
1 shared publication- Sonya G. Gordon
Department of Small Animal Clinical Sciences, College of Veterinary Medicine and Biomedical Sciences, Texas A&M University , College Station, TX 77843
1 shared publication Sonya Gordon
Department of Small Animal Medicine and Surgery, College of Veterinary Medicine, Texas A&M University, College Station, TX
1 shared publication
Latest Publications
- 1 January 2007
- Published by Wiley in Journal of Veterinary Internal Medicine
- Vol. 21 (1) , 68-75
Echocardiographic and Angiographic Comparison of Ductal Dimensions in Dogs with Patent Ductus Arteriosus
Transcatheter occlusion of patent ductus arteriosus (PDA) is a minimally invasive treatment option in dogs. Device selection based on appropriately acquired PDA dimensions and morphology can minimize procedural complications, including minimizing residual ductal flow and inappropriate embolization. Transesophageal echocardiographic (TEE) derived minimum ductal diameter measurements would most accurately reflect angiographic measurements. Color Doppler (CD) TEE and transthoracic echocardiographic (TTE) ductal measurements would overestimate two-dimensional (2D) measurements. Fifteen client-owned dogs with PDA. PDA dimensions obtained with angiography, 2D and CD TTE, 2D and CD TEE from the right and left views were prospectively evaluated. PDA dimensions were measured by using TEE most closely approximated angiographic measures. CD TTE and TEE frequently overestimated angiographic measures of minimum ductal diameter. TEE accurately identified a type III (tubular) PDA morphology in 1 dog. Fourteen of 15 dogs were determined to have hemodynamically significant reductions in left to right shunting documented by a first-pass nuclear angiocardiographic ratio of pulmonary to systemic blood flow < or = 1.2 and trivial (n = 3) to no (n = 11) CD TTE flow at approximately 1 month after PDA occlusion. TEE provided accurate anatomic information regarding PDA morphology and closely approximated angiographic ductal dimensions while aiding in both coil deployment and confirmation of intra-operative ductal closure.
- 1 January 2007
- Published by Wiley in Journal of Veterinary Internal Medicine
- Vol. 21 (1) , 68-75
Echocardiographic and Angiographic Comparison of Ductal Dimensions in Dogs with Patent Ductus Arteriosus
Transcatheter occlusion of patent ductus arteriosus (PDA) is a minimally invasive treatment option in dogs. Device selection based on appropriately acquired PDA dimensions and morphology can minimize procedural complications, including minimizing residual ductal flow and inappropriate embolization. Transesophageal echocardiographic (TEE) derived minimum ductal diameter measurements would most accurately reflect angiographic measurements. Color Doppler (CD) TEE and transthoracic echocardiographic (TTE) ductal measurements would overestimate two-dimensional (2D) measurements. Fifteen client-owned dogs with PDA. PDA dimensions obtained with angiography, 2D and CD TTE, 2D and CD TEE from the right and left views were prospectively evaluated. PDA dimensions were measured by using TEE most closely approximated angiographic measures. CD TTE and TEE frequently overestimated angiographic measures of minimum ductal diameter. TEE accurately identified a type III (tubular) PDA morphology in 1 dog. Fourteen of 15 dogs were determined to have hemodynamically significant reductions in left to right shunting documented by a first-pass nuclear angiocardiographic ratio of pulmonary to systemic blood flow < or = 1.2 and trivial (n = 3) to no (n = 11) CD TTE flow at approximately 1 month after PDA occlusion. TEE provided accurate anatomic information regarding PDA morphology and closely approximated angiographic ductal dimensions while aiding in both coil deployment and confirmation of intra-operative ductal closure.
- 1 January 2002
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 16 (1) , 74-79
First-Pass Nuclear Angiocardiography in the Evaluation of Patent Ductus Arteriosus in Dogs
First-pass nuclear angiocardiography (FPNA) was performed in 5 normal dogs and in 19 dogs with left-to-right shunting patent ductus arteriosus (PDA). Affected dogs were evaluated before and after an occlusion procedure (surgical ligation or transarterial coil embolization). Two methods of analysis were used to evaluate the pulmonary time-activity curves and assess the magnitude of the shunt. One method involved the calculation of a simple count ratio (C2:C1). The other method used gamma variate modeling to estimate the ratio of pulmonary to systemic blood flow (QP:QS). Values for normal dogs (mean +/- SD) were C2:C1 = 0.39 +/- 0.11 and QP:QS = 1.10 +/- 0.03. Values for affected dogs were C2:C1 = 0.59 +/- 0.17, QP:QS = 2.01 +/- 0.46 before intervention and QP:QS = 1.21 +/- 0.17, C2:C1 = 0.42 +/- 0.12 after intervention. Both methods detected significant differences between normal and affected dogs (QP:QS, t-test, P < .001; C2:C1; t-test; P = .018) and between affected dogs pre- and postocclusion (QP:QS. paired t-test, P < .001; C2:C1, paired t-test, P = .002). However, QP:QS was a better separator of normal from affected animals. First-pass nuclear angiocardiography, by the gamma variate method, may be a useful, adjunct diagnostic test in evaluation of animals with left-to-fight shunting PDA, particularly in animals with residual shunting after an occlusion procedure.
- 1 January 2002
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 16 (1) , 74-79
First-Pass Nuclear Angiocardiography in the Evaluation of Patent Ductus Arteriosus in Dogs
First-pass nuclear angiocardiography (FPNA) was performed in 5 normal dogs and in 19 dogs with left-to-right shunting patent ductus arteriosus (PDA). Affected dogs were evaluated before and after an occlusion procedure (surgical ligation or transarterial coil embolization). Two methods of analysis were used to evaluate the pulmonary time-activity curves and assess the magnitude of the shunt. One method involved the calculation of a simple count ratio (C2:C1). The other method used gamma variate modeling to estimate the ratio of pulmonary to systemic blood flow (QP:QS). Values for normal dogs (mean +/- SD) were C2:C1 = 0.39 +/- 0.11 and QP:QS = 1.10 +/- 0.03. Values for affected dogs were C2:C1 = 0.59 +/- 0.17, QP:QS = 2.01 +/- 0.46 before intervention and QP:QS = 1.21 +/- 0.17, C2:C1 = 0.42 +/- 0.12 after intervention. Both methods detected significant differences between normal and affected dogs (QP:QS, t-test, P < .001; C2:C1; t-test; P = .018) and between affected dogs pre- and postocclusion (QP:QS. paired t-test, P < .001; C2:C1, paired t-test, P = .002). However, QP:QS was a better separator of normal from affected animals. First-pass nuclear angiocardiography, by the gamma variate method, may be a useful, adjunct diagnostic test in evaluation of animals with left-to-fight shunting PDA, particularly in animals with residual shunting after an occlusion procedure.