Kathleen Kreiss
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kathleen Kreiss has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Christine R. Schuler
Division of Respiratory Disease Studies, Field Studies Branch, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WVa 26505, USA
3 shared publications - Marcia L. Stanton
Respiratory Health Division, National Institute for Occupational Safety and Health, Morgantown, WV, United States
3 shared publications Paul L. Enright
College of Public Health, The University of Arizona, Tucson, Arizona
3 shared publications- Aleksandr Byron Stefaniak
Respiratory Health Division, National Institute for Occupational Safety and Health, Morgantown, WV 26505, USA
2 shared publications Barbara L. Materna
Occupational Health Branch, Division of Environmental and Occupational Disease Control, California Department of Public Health (CDPH), Richmond, California
2 shared publicationsGregory A Day
2 shared publications
Latest Publications
- 25 June 2014
- Published by Wiley in American Journal of Industrial Medicine
- Vol. 57 (8) , 972
The authors respond to Egilman
- 25 June 2014
- Published by Wiley in American Journal of Industrial Medicine
- Vol. 57 (8) , 972
The authors respond to Egilman
- Open Access
- 23 June 2014
- Published by BMJ in Occupational and Environmental Medicine
- Vol. 71 (Suppl 1) , A63.3-A63
0041 Associations of thermophilic actinomycetes and non-tuberculous mycobacteria with respiratory health in occupants of a water-damaged office building
Objectives We examined microbial correlates of health outcomes in employees in a building with a sarcoidosis cluster and excess asthma. Method We offered employees a questionnaire and pulmonary function tests (PFT) and collected 120 floor dust samples by vacuuming workstation areas or the exterior rim of the floor. We analysed dust for culturable fungi, bacteria, actinomycetes, non-tuberculous mycobacteria, and cell wall components of fungi [(1→3)-β-D-glucan] and Gram-negative bacteria (endotoxin). Results Among 136 employees, 77% participated in the questionnaire, 64% in PFTs, and 49% in both. Of the 105 questionnaire participants, 50 (48%) reported at least one hypersensitivity pneumonitis (HP)-like symptom (shortness of breath on exertion, flu-like achiness, or fever and chills) in the last 4 weeks; 69 (66%) reported at least one HP-like symptom in the last 12 months. PFT results were abnormal or borderline for 13 participants (6 obstruction; 2 restriction; 2 mixed pattern; and 3 borderline obstruction). In multivariate logistic regressions, log-transformed levels of thermophilic actinomycetes (GM=580 CFU/m2) were positively associated with HP-like symptoms in the last 4 weeks [odds ratio (OR)=1.6, 95% confidence interval (CI)=1.15–2.35] and 12 months (OR=1.6, 95% CI=1.09–2.32), and with an abnormal/borderline PFT result (OR=1.7, 95% CI=1.04–2.88). Log-transformed mycobacteria levels (GM=960 CFU/m2) were marginally positively associated with HP-like symptoms in the last 4 weeks that improved when away from the building (OR=1.9; 95% CI=0.95–3.85). These associations were not confounded by smoking, gender, age, or building tenure. Conclusions Our study suggests that thermophilic actinomycetes and non-tuberculous mycobacteria may have played a role in the respiratory illness among occupants of this water-damaged building.
- 23 June 2014
- Published by BMJ in Occupational and Environmental Medicine
- Vol. 71 (Suppl 1) , A63.3-A63
Open Access0041 Associations of thermophilic actinomycetes and non-tuberculous mycobacteria with respiratory health in occupants of a water-damaged office building
Objectives We examined microbial correlates of health outcomes in employees in a building with a sarcoidosis cluster and excess asthma. Method We offered employees a questionnaire and pulmonary function tests (PFT) and collected 120 floor dust samples by vacuuming workstation areas or the exterior rim of the floor. We analysed dust for culturable fungi, bacteria, actinomycetes, non-tuberculous mycobacteria, and cell wall components of fungi [(1→3)-β-D-glucan] and Gram-negative bacteria (endotoxin). Results Among 136 employees, 77% participated in the questionnaire, 64% in PFTs, and 49% in both. Of the 105 questionnaire participants, 50 (48%) reported at least one hypersensitivity pneumonitis (HP)-like symptom (shortness of breath on exertion, flu-like achiness, or fever and chills) in the last 4 weeks; 69 (66%) reported at least one HP-like symptom in the last 12 months. PFT results were abnormal or borderline for 13 participants (6 obstruction; 2 restriction; 2 mixed pattern; and 3 borderline obstruction). In multivariate logistic regressions, log-transformed levels of thermophilic actinomycetes (GM=580 CFU/m2) were positively associated with HP-like symptoms in the last 4 weeks [odds ratio (OR)=1.6, 95% confidence interval (CI)=1.15–2.35] and 12 months (OR=1.6, 95% CI=1.09–2.32), and with an abnormal/borderline PFT result (OR=1.7, 95% CI=1.04–2.88). Log-transformed mycobacteria levels (GM=960 CFU/m2) were marginally positively associated with HP-like symptoms in the last 4 weeks that improved when away from the building (OR=1.9; 95% CI=0.95–3.85). These associations were not confounded by smoking, gender, age, or building tenure. Conclusions Our study suggests that thermophilic actinomycetes and non-tuberculous mycobacteria may have played a role in the respiratory illness among occupants of this water-damaged building.
- 22 November 2013
- Published by Wiley in American Journal of Industrial Medicine
- Vol. 57 (2) , 129-137
Work‐related spirometric restriction in flavoring manufacturing workers
Background: Flavoring‐exposed workers are at risk for occupational lung disease.Methods: We examined serial spirometries from corporate medical surveillance of flavoring production workers to assess abnormality compared to the U.S. population; mean decline in forced expiratory volume in one second (FEV1) and forced vital capacity (FVC); and excessive declines in FEV1.Results: Of 106 workers, 30 had spirometric restriction, 3 had obstruction, 1 had both, and 13 (of 70, 19%) had excessive declines in FEV1. The adjusted prevalence of restriction was 3.7 times expected. Employees with higher potential for flavorings exposure had 3.0 times and 2.4 times greater average annual declines in FEV1 and FVC respectively, and had 5.8 times higher odds of having excessive FEV1 declines than employees with lower potential for exposure.Conclusion: Exposure‐related spirometric abnormalities consistent with a restrictive process evolved during employment, suggesting that exposures in flavoring production are associated with a range of pathophysiology. Am. J. Ind. Med. 57:129–137, 2014. Published 2013. This article is a U.S. Government work and is in the public domain in the USA.
- 22 November 2013
- Published by Wiley in American Journal of Industrial Medicine
- Vol. 57 (2) , 129-137
Work‐related spirometric restriction in flavoring manufacturing workers
Background: Flavoring‐exposed workers are at risk for occupational lung disease.Methods: We examined serial spirometries from corporate medical surveillance of flavoring production workers to assess abnormality compared to the U.S. population; mean decline in forced expiratory volume in one second (FEV1) and forced vital capacity (FVC); and excessive declines in FEV1.Results: Of 106 workers, 30 had spirometric restriction, 3 had obstruction, 1 had both, and 13 (of 70, 19%) had excessive declines in FEV1. The adjusted prevalence of restriction was 3.7 times expected. Employees with higher potential for flavorings exposure had 3.0 times and 2.4 times greater average annual declines in FEV1 and FVC respectively, and had 5.8 times higher odds of having excessive FEV1 declines than employees with lower potential for exposure.Conclusion: Exposure‐related spirometric abnormalities consistent with a restrictive process evolved during employment, suggesting that exposures in flavoring production are associated with a range of pathophysiology. Am. J. Ind. Med. 57:129–137, 2014. Published 2013. This article is a U.S. Government work and is in the public domain in the USA.
- 12 August 2013
- Published by BMJ in Occupational and Environmental Medicine
- Vol. 70 (10) , 679-680
Dampness and mould in schools and respiratory symptoms
- 12 August 2013
- Published by BMJ in Occupational and Environmental Medicine
- Vol. 70 (10) , 679-680
Dampness and mould in schools and respiratory symptoms
- 1 April 2013
- Published by Wolters Kluwer Health in Current Opinion in Allergy and Clinical Immunology
- Vol. 13 (2) , 167-172
Occupational causes of constrictive bronchiolitis
Purpose of review New literature from 2009 to 2012 regarding occupational constrictive bronchiolitis challenges textbook descriptions of this disease, formerly thought to be limited to fixed airflow limitation arising in the wake of accidental overexposure to noxious chemicals. Indolent evolution of dyspnea without a recognized hazardous exposure is a more common presentation. Recent findings Biopsy-confirmed case series of constrictive bronchiolitis from US soldiers, Iranian survivors of sulfur mustard gassing, hospital-based studies, and flavoring-related cases document that indolent constrictive bronchiolitis cases can have normal spirometry or either restrictive or obstructive abnormalities. High-resolution computerized tomography studies can be normal or reflect air-trapping and mosaic attenuation on expiratory films. Thus, in the absence of noninvasive abnormalities, the diagnosis in dyspneic patients may require thoracoscopic biopsy in settings in which exposure risk has not been recognized. Many workers with occupational constrictive bronchiolitis stabilize with cessation of exposures causing bronchiolar epithelial necrosis. Summary Clinicians need a high index of suspicion for constrictive bronchiolitis in young patients with rapidly progressing exertional dyspnea, regardless of spirometric and radiologic findings. Identification of novel causes and exposure-response relations for known causes are needed to provide guidance for protecting workers at risk for this largely irreversible lung disease.
- 1 April 2013
- Published by Wolters Kluwer Health in Current Opinion in Allergy and Clinical Immunology
- Vol. 13 (2) , 167-172
Occupational causes of constrictive bronchiolitis
Purpose of review New literature from 2009 to 2012 regarding occupational constrictive bronchiolitis challenges textbook descriptions of this disease, formerly thought to be limited to fixed airflow limitation arising in the wake of accidental overexposure to noxious chemicals. Indolent evolution of dyspnea without a recognized hazardous exposure is a more common presentation. Recent findings Biopsy-confirmed case series of constrictive bronchiolitis from US soldiers, Iranian survivors of sulfur mustard gassing, hospital-based studies, and flavoring-related cases document that indolent constrictive bronchiolitis cases can have normal spirometry or either restrictive or obstructive abnormalities. High-resolution computerized tomography studies can be normal or reflect air-trapping and mosaic attenuation on expiratory films. Thus, in the absence of noninvasive abnormalities, the diagnosis in dyspneic patients may require thoracoscopic biopsy in settings in which exposure risk has not been recognized. Many workers with occupational constrictive bronchiolitis stabilize with cessation of exposures causing bronchiolar epithelial necrosis. Summary Clinicians need a high index of suspicion for constrictive bronchiolitis in young patients with rapidly progressing exertional dyspnea, regardless of spirometric and radiologic findings. Identification of novel causes and exposure-response relations for known causes are needed to provide guidance for protecting workers at risk for this largely irreversible lung disease.
- 25 October 2012
- Published by Wiley in American Journal of Industrial Medicine
- Vol. 56 (3) , 300-307
Serial evaluations at an indium‐tin oxide production facility
Background We evaluated the effectiveness of workplace changes to prevent indium lung disease, using 2002–2010 surveillance data collected by an indium‐tin oxide production facility. Methods We assessed pulmonary function using lower limits of normal. Blood indium concentration and personal air sampling data were used to estimate exposure. Results Abnormalities were uncommon at hire. After hire, prevalence of spirometric restriction was 31% (n = 14/45), about fourfold higher than expected. Excessive decline in FEV1 was elevated at 29% (n = 12/41). Half (n = 21/42) had blood indium ≥5 µg/l. More recent hires had fewer abnormalities. There was a suggestion that abnormalities were more common among workers with blood indium ≥5 µg/l, but otherwise an exposure‐response relationship was not evident. Peak dust concentrations were obscured by time averaging. Conclusions Evolving lung function abnormalities consistent with subclinical indium lung disease appeared common and merit systematic investigation. Traditional measures of exposure and response were not illustrative, suggesting fresh approaches will be needed. Workplace changes seemed to have had a positive though incomplete impact; novel preventive interventions are warranted. Am. J. Ind. Med. 56:300–307, 2013.
- 25 October 2012
- Published by Wiley in American Journal of Industrial Medicine
- Vol. 56 (3) , 300-307
Serial evaluations at an indium‐tin oxide production facility
Background We evaluated the effectiveness of workplace changes to prevent indium lung disease, using 2002–2010 surveillance data collected by an indium‐tin oxide production facility. Methods We assessed pulmonary function using lower limits of normal. Blood indium concentration and personal air sampling data were used to estimate exposure. Results Abnormalities were uncommon at hire. After hire, prevalence of spirometric restriction was 31% (n = 14/45), about fourfold higher than expected. Excessive decline in FEV1 was elevated at 29% (n = 12/41). Half (n = 21/42) had blood indium ≥5 µg/l. More recent hires had fewer abnormalities. There was a suggestion that abnormalities were more common among workers with blood indium ≥5 µg/l, but otherwise an exposure‐response relationship was not evident. Peak dust concentrations were obscured by time averaging. Conclusions Evolving lung function abnormalities consistent with subclinical indium lung disease appeared common and merit systematic investigation. Traditional measures of exposure and response were not illustrative, suggesting fresh approaches will be needed. Workplace changes seemed to have had a positive though incomplete impact; novel preventive interventions are warranted. Am. J. Ind. Med. 56:300–307, 2013.
- 1 July 2012
- Published by Wolters Kluwer Health in Clinical Pulmonary Medicine
- Vol. 19 (4) , 165-173
Respiratory Disease Among Flavoring-exposed Workers in Food and Flavoring Manufacture
Fixed airways obstruction was found in workers producing microwave popcorn in relation to inhaling synthetic butter flavoring volatiles in 2000. Since then, an industry-wide hazard of clinical bronchiolitis obliterans was found in other microwave-popcorn plants, in flavoring manufacture, and in diacetyl (2,3-butanedione) manufacture. Recently, workers in 1 food production and 1 flavoring manufacturing facility have had excesses of spirometric restrictive abnormalities. Evidence of flavoring-related excessive declines in forced expiratory volume in 1 second (FEV1) suggests that restriction in the latter flavoring plant is work-related. However, the pathologic and physiological correlates of restriction in flavoring-exposed workers remain uninvestigated. Diacetyl vapor causes respiratory epithelial necrosis in rodents, compatible with the pathologic mechanism for constrictive bronchiolitis, but exposures in flavoring manufacturing are more diverse than diacetyl. The diacetyl substitute, 2,3-pentanedione, has comparable toxicity to diacetyl, and other members of the α-diketone family have not been evaluated for respiratory toxicity. With the increasing spectrum of flavoring-related lung diseases and chemical exposures, pulmonologists caring for flavoring-exposed workers have novel challenges. These include examining excessive FEV1 declines in serial spirometry and improving surveillance spirometry quality so that excessive declines can be detected at an earlier stage. The best means of preventing permanent impairment from irreversible occupational lung disease is to intervene for workers with excessive FEV1 decline within the normal range and before diagnostic criteria for occupational lung disease can be met. Regulation of diacetyl and 2,3-pentanedione, which does not yet exist, may not prevent all occupational lung disease in flavoring-exposed workers.
- 1 July 2012
- Published by Wolters Kluwer Health in Clinical Pulmonary Medicine
- Vol. 19 (4) , 165-173
Respiratory Disease Among Flavoring-exposed Workers in Food and Flavoring Manufacture
Fixed airways obstruction was found in workers producing microwave popcorn in relation to inhaling synthetic butter flavoring volatiles in 2000. Since then, an industry-wide hazard of clinical bronchiolitis obliterans was found in other microwave-popcorn plants, in flavoring manufacture, and in diacetyl (2,3-butanedione) manufacture. Recently, workers in 1 food production and 1 flavoring manufacturing facility have had excesses of spirometric restrictive abnormalities. Evidence of flavoring-related excessive declines in forced expiratory volume in 1 second (FEV1) suggests that restriction in the latter flavoring plant is work-related. However, the pathologic and physiological correlates of restriction in flavoring-exposed workers remain uninvestigated. Diacetyl vapor causes respiratory epithelial necrosis in rodents, compatible with the pathologic mechanism for constrictive bronchiolitis, but exposures in flavoring manufacturing are more diverse than diacetyl. The diacetyl substitute, 2,3-pentanedione, has comparable toxicity to diacetyl, and other members of the α-diketone family have not been evaluated for respiratory toxicity. With the increasing spectrum of flavoring-related lung diseases and chemical exposures, pulmonologists caring for flavoring-exposed workers have novel challenges. These include examining excessive FEV1 declines in serial spirometry and improving surveillance spirometry quality so that excessive declines can be detected at an earlier stage. The best means of preventing permanent impairment from irreversible occupational lung disease is to intervene for workers with excessive FEV1 decline within the normal range and before diagnostic criteria for occupational lung disease can be met. Regulation of diacetyl and 2,3-pentanedione, which does not yet exist, may not prevent all occupational lung disease in flavoring-exposed workers.
- 19 September 2011
- Published by Wiley in American Journal of Industrial Medicine
- Vol. 55 (8) , 657-668
Longitudinal lung function declines among California flavoring manufacturing workers
Background: The California Department of Public Health received serial spirometry data for flavoring manufacturing workers at 20 companies at risk of bronchiolitis obliterans.Methods: We graded spirometry quality; identified individual workers with excessive decline in forced expiratory volume in 1 s (FEV1) using relative longitudinal limits of decline based on 4% average within‐person variability; and analyzed declines by occupational risk factors.Results: The quality of 1,696 spirometry tests from 724 workers varied by 17 providers, with poorer quality from commercial providers. Of 416 workers with at least two tests, 40 (9.6%) had abnormal FEV1 decline. Of 289 workers with high quality spirometry, 21 (7.3%) had abnormal decline. Only one of the 21 had airways obstruction. Abnormal FEV1 decline rates (per person‐month) were greater among workers at companies using ≥800 lbs/year diacetyl than at companies using lesser amounts. Abnormal FEV1 decline rates were greater at companies previously having four‐person clusters of spirometric obstruction than at companies with no or only one worker with obstruction.Conclusions: Spirometric surveillance of flavoring workers can identify individual workers with an abnormal FEV1 decline for preventive intervention, even when the FEV1 itself remains within the normal range. Good quality spirometry and classification of abnormal with relative longitudinal limit of decline minimize misclassification of possible work‐related health effects. Am. J. Ind. Med. 55:657–668, 2012.
- 19 September 2011
- Published by Wiley in American Journal of Industrial Medicine
- Vol. 55 (8) , 657-668
Longitudinal lung function declines among California flavoring manufacturing workers
Background: The California Department of Public Health received serial spirometry data for flavoring manufacturing workers at 20 companies at risk of bronchiolitis obliterans.Methods: We graded spirometry quality; identified individual workers with excessive decline in forced expiratory volume in 1 s (FEV1) using relative longitudinal limits of decline based on 4% average within‐person variability; and analyzed declines by occupational risk factors.Results: The quality of 1,696 spirometry tests from 724 workers varied by 17 providers, with poorer quality from commercial providers. Of 416 workers with at least two tests, 40 (9.6%) had abnormal FEV1 decline. Of 289 workers with high quality spirometry, 21 (7.3%) had abnormal decline. Only one of the 21 had airways obstruction. Abnormal FEV1 decline rates (per person‐month) were greater among workers at companies using ≥800 lbs/year diacetyl than at companies using lesser amounts. Abnormal FEV1 decline rates were greater at companies previously having four‐person clusters of spirometric obstruction than at companies with no or only one worker with obstruction.Conclusions: Spirometric surveillance of flavoring workers can identify individual workers with an abnormal FEV1 decline for preventive intervention, even when the FEV1 itself remains within the normal range. Good quality spirometry and classification of abnormal with relative longitudinal limit of decline minimize misclassification of possible work‐related health effects. Am. J. Ind. Med. 55:657–668, 2012.
- Open Access
- 17 August 2011
- Published by Scandinavian Journal of Work, Environment and Health in Scandinavian Journal of Work, Environment & Health
- Vol. 38 (3) , 247-258
Sensitization and chronic beryllium disease at a primary manufacturing facility, part 1: historical exposure reconstruction
Previous epidemiologic studies of beryllium sensitization (BeS) and chronic beryllium disease (CBD) have reported inconsistent exposure-response relationships, likely due to exposure misclassification. The objective of this study was to develop historical estimates of size-selective personal exposure to beryllium for an epidemiologic study. In 1999, a cross-sectional survey of workers hired after 1 January 1994 was conducted at a beryllium production facility. Personal exposure data from two air sampling surveys conducted in 1999 were used to obtain total, respirable, and submicron particle baseline exposure estimates (BEE) for a job-exposure matrix (JEM). General area air samples collected from 1994-1999 were used to estimate annual changes in exposures (temporal factors) for 24 different process areas. Historical exposure estimates (HEE) were calculated by applying the temporal factors to the BEE. Workers were assigned HEE based on their work history, and their historical exposure profile was summarized as cumulative, average, or highest-ever job exposure. Changes in exposure over a 6-year period were observed in 10 of the 24 process areas with an overall mean decline of 18% per year. The overall total exposure for study participants over their work tenure ranged from: 0.001-34.44 μg/m(3)-year, 0.01-16.26 μg/m(3), and 0.01-17.54 μg /m(3) for cumulative, average, and highest-ever job, respectively. For respirable exposures, the ranges were: 0.001-15.54 μg/m(3)-year, 0.01-3.56 μg/m(3), 0.01-5.54 μg /m(3) for cumulative, average, and highest-ever job, respectively. Using this JEM, exposure-response relationships for BeS and CBD can be explored over a range of exposure metrics such as total, respirable, and submicron beryllium mass concentrations, including summary measures such as cumulative, average, or highest exposures, with the ultimate objective of elucidating a quantitative exposure-response relationship.
- 17 August 2011
- Published by Scandinavian Journal of Work, Environment and Health in Scandinavian Journal of Work, Environment & Health
- Vol. 38 (3) , 247-258
Open AccessSensitization and chronic beryllium disease at a primary manufacturing facility, part 1: historical exposure reconstruction
Previous epidemiologic studies of beryllium sensitization (BeS) and chronic beryllium disease (CBD) have reported inconsistent exposure-response relationships, likely due to exposure misclassification. The objective of this study was to develop historical estimates of size-selective personal exposure to beryllium for an epidemiologic study. In 1999, a cross-sectional survey of workers hired after 1 January 1994 was conducted at a beryllium production facility. Personal exposure data from two air sampling surveys conducted in 1999 were used to obtain total, respirable, and submicron particle baseline exposure estimates (BEE) for a job-exposure matrix (JEM). General area air samples collected from 1994-1999 were used to estimate annual changes in exposures (temporal factors) for 24 different process areas. Historical exposure estimates (HEE) were calculated by applying the temporal factors to the BEE. Workers were assigned HEE based on their work history, and their historical exposure profile was summarized as cumulative, average, or highest-ever job exposure. Changes in exposure over a 6-year period were observed in 10 of the 24 process areas with an overall mean decline of 18% per year. The overall total exposure for study participants over their work tenure ranged from: 0.001-34.44 μg/m(3)-year, 0.01-16.26 μg/m(3), and 0.01-17.54 μg /m(3) for cumulative, average, and highest-ever job, respectively. For respirable exposures, the ranges were: 0.001-15.54 μg/m(3)-year, 0.01-3.56 μg/m(3), 0.01-5.54 μg /m(3) for cumulative, average, and highest-ever job, respectively. Using this JEM, exposure-response relationships for BeS and CBD can be explored over a range of exposure metrics such as total, respirable, and submicron beryllium mass concentrations, including summary measures such as cumulative, average, or highest exposures, with the ultimate objective of elucidating a quantitative exposure-response relationship.