Robert Bauernschmitt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Robert Bauernschmitt has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Rüdiger Lange
Department of Cardiovascular Surgery, German Heart Centre Munich, Technische Universität München, 80636 Munich, Germany
8 shared publications - Sabine Bleiziffer
Clinic for Cardiovascular Surgery, Department of Cardiovascular Surgery, German Heart Center, Technical University Munich, Lazarettstr. 36, 80636, Munich, Germany.
8 shared publications - Walter Benno Eichinger
German Heart Center Munich, Department of Cardiovascular Surgery, Munich, Germany
7 shared publications Ruediger Lange
5 shared publicationsFlorian Botzenhardt
3 shared publications- Markus Krane
Department of Cardiovascular Surgery, Institute Insure, German Heart Center Munich, School of Medicine & Health, Technical University of Munich, Lazarettstrasse 36, 80636 Munich, Germany
3 shared publications
Latest Publications
- Open Access
- 1 April 2011
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 40 (5) , 1105-1113
Incidence and treatment of procedural cardiovascular complications associated with trans-arterial and trans-apical interventional aortic valve implantation in 412 consecutive patients
Objective: Trans-catheter aortic valve implantation (TAVI) technology is rapidly evolving, with 412 procedures having been performed at our institution. Herein, we report a complete, prospective analysis of complications occurring during transvascular and trans-apical implantations with two different prostheses. Methods: Between June 2007 and June 2010, 412 patients (258 female, mean age 80.3 ± 7.2 years, logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) 20.2% ± 13.0%) underwent TAVI through either a retrograde (n = 252 transfemoral, n = 28 transaxillary, and n = 5 transaortic) or antegrade (n = 127 trans-apical) approach at our institution. The trans-apical access was chosen only in cases where transvascular implantation was not possible. As many as 283 CoreValve and 129 Edwards Sapien prostheses were implanted. Results: Thirty-day survival was 90.9%. Vascular complications occurred in 42 patients (10.2%). In four patients, lethal aortic root (n = 3) or abdominal (n = 1) aortic rupture occurred. Pericardial effusion developed in 53 patients (12.8%), which resulted in cardiac tamponade in 12 patients (2.9%). Twenty-three patients (5.6%) with valve malplacement were treated interventionally. In five patients (1.2%), emergency institution of cardiopulmonary bypass was required during the procedure for temporary support; all patients survived. Seventeen patients underwent re-intervention on the catheter valve (4.1%). Conclusions: With growing experience, complications with TAVI may be avoided by proper patient selection and skillful management. Other complications, when they occur, require a specific treatment algorithm to avoid delay in decision making. A considerable number of complications after TAVI require surgical treatment. Therefore, the ideal environment for TAVI procedures is a hybrid operating room, where a multidisciplinary team of surgeons, cardiologists, and anesthesiologists is best fitted to meet the current needs associated with TAVI technology. A reduction in complications was seen after 300 cases. This finding attests to the complexity of the procedure in addition to the experience required to reduce the incidence of complications.
- 1 April 2011
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 40 (5) , 1105-1113
Open AccessIncidence and treatment of procedural cardiovascular complications associated with trans-arterial and trans-apical interventional aortic valve implantation in 412 consecutive patients
Objective: Trans-catheter aortic valve implantation (TAVI) technology is rapidly evolving, with 412 procedures having been performed at our institution. Herein, we report a complete, prospective analysis of complications occurring during transvascular and trans-apical implantations with two different prostheses. Methods: Between June 2007 and June 2010, 412 patients (258 female, mean age 80.3 ± 7.2 years, logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) 20.2% ± 13.0%) underwent TAVI through either a retrograde (n = 252 transfemoral, n = 28 transaxillary, and n = 5 transaortic) or antegrade (n = 127 trans-apical) approach at our institution. The trans-apical access was chosen only in cases where transvascular implantation was not possible. As many as 283 CoreValve and 129 Edwards Sapien prostheses were implanted. Results: Thirty-day survival was 90.9%. Vascular complications occurred in 42 patients (10.2%). In four patients, lethal aortic root (n = 3) or abdominal (n = 1) aortic rupture occurred. Pericardial effusion developed in 53 patients (12.8%), which resulted in cardiac tamponade in 12 patients (2.9%). Twenty-three patients (5.6%) with valve malplacement were treated interventionally. In five patients (1.2%), emergency institution of cardiopulmonary bypass was required during the procedure for temporary support; all patients survived. Seventeen patients underwent re-intervention on the catheter valve (4.1%). Conclusions: With growing experience, complications with TAVI may be avoided by proper patient selection and skillful management. Other complications, when they occur, require a specific treatment algorithm to avoid delay in decision making. A considerable number of complications after TAVI require surgical treatment. Therefore, the ideal environment for TAVI procedures is a hybrid operating room, where a multidisciplinary team of surgeons, cardiologists, and anesthesiologists is best fitted to meet the current needs associated with TAVI technology. A reduction in complications was seen after 300 cases. This finding attests to the complexity of the procedure in addition to the experience required to reduce the incidence of complications.
- 1 March 2011
- Vol. 20 (2) , 191-8
Long-term performance of the Hancock bioprosthetic valved conduit in the aortic root position.
The study aim was to assess long-term morbidity and mortality with special regard to prosthesis durability after aortic root replacement with the Hancock bioprosthetic porcine conduit. Between 1975 and 2004, a total of 81 patients (55 males, 26 females; mean age 58 +/- 18 years) underwent aortic root replacement with the Hancock conduit for aortic dissection (n = 22; 27%), ascending aortic aneurysm (n = 57; 70%), or porcelain aorta (n = 2; 3%). Twenty-five patients (31%) underwent an emergency operation, 12 (15%) presented with Marfan syndrome, and eight (10%) had undergone previous cardiac surgery. Concomitant procedures were performed in 26 cases (32%). The follow up was 98% complete; the mean follow up was 4.8 +/- 4.0 years (range: 1 day to 16.7 years), and the cumulative follow up was 403 patient-years. Actuarial event-free rates were calculated, and valve-related complications classified according to guidelines for reporting morbidity and mortality after cardiac valvular operations. There were seven (9%) operative deaths and four (5%) in-hospital deaths. Actuarial survival rates at five and 10 years (excluding operative deaths) were 77.0 +/- 5.3% and 54.0 +/- 7.5%, respectively. Actuarial freedom from aortic valve reoperation at five and 10 years was 98 +/- 1.6% and 64 +/- 10.2%, from structural valve deterioration 88.1 +/- 4.7% and 49.9 +/- 9.6%, from thromboembolic events 87.4 +/- 4.6% and 75.1 +/- 9.5%, and from major bleeding events 90.2 +/- 3.9% and 75.4 +/- 8.1%, respectively. Among redo procedures, the stentless Hancock valve could be excised without separating the synthetic graft from the left ventricular outflow tract, and a stented valve prosthesis thus implanted. Hence, it was possible to avoid a second Bentall operation. The long-term survival rates after aortic root replacement with the bioprosthetic Hancock conduit were reasonable for this demanding patient cohort. However, the durability of the prosthesis was inferior to that reported for the stented Hancock valve substitute. The key benefit of this bioprosthetic valved conduit was the simplified redo procedure.
- 1 March 2011
- Vol. 20 (2) , 191-8
Long-term performance of the Hancock bioprosthetic valved conduit in the aortic root position.
The study aim was to assess long-term morbidity and mortality with special regard to prosthesis durability after aortic root replacement with the Hancock bioprosthetic porcine conduit. Between 1975 and 2004, a total of 81 patients (55 males, 26 females; mean age 58 +/- 18 years) underwent aortic root replacement with the Hancock conduit for aortic dissection (n = 22; 27%), ascending aortic aneurysm (n = 57; 70%), or porcelain aorta (n = 2; 3%). Twenty-five patients (31%) underwent an emergency operation, 12 (15%) presented with Marfan syndrome, and eight (10%) had undergone previous cardiac surgery. Concomitant procedures were performed in 26 cases (32%). The follow up was 98% complete; the mean follow up was 4.8 +/- 4.0 years (range: 1 day to 16.7 years), and the cumulative follow up was 403 patient-years. Actuarial event-free rates were calculated, and valve-related complications classified according to guidelines for reporting morbidity and mortality after cardiac valvular operations. There were seven (9%) operative deaths and four (5%) in-hospital deaths. Actuarial survival rates at five and 10 years (excluding operative deaths) were 77.0 +/- 5.3% and 54.0 +/- 7.5%, respectively. Actuarial freedom from aortic valve reoperation at five and 10 years was 98 +/- 1.6% and 64 +/- 10.2%, from structural valve deterioration 88.1 +/- 4.7% and 49.9 +/- 9.6%, from thromboembolic events 87.4 +/- 4.6% and 75.1 +/- 9.5%, and from major bleeding events 90.2 +/- 3.9% and 75.4 +/- 8.1%, respectively. Among redo procedures, the stentless Hancock valve could be excised without separating the synthetic graft from the left ventricular outflow tract, and a stented valve prosthesis thus implanted. Hence, it was possible to avoid a second Bentall operation. The long-term survival rates after aortic root replacement with the bioprosthetic Hancock conduit were reasonable for this demanding patient cohort. However, the durability of the prosthesis was inferior to that reported for the stented Hancock valve substitute. The key benefit of this bioprosthetic valved conduit was the simplified redo procedure.
- 31 January 2011
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 91 (1) , 96
Invited Commentary
- 31 January 2011
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 91 (1) , 96
Invited Commentary
- 15 January 2011
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 40 (2)
Apical-access-related complications associated with trans-catheter aortic valve implantation.
The left-ventricular trans-apical access has become well established for trans-catheter aortic valve implantation, especially for patients in whom a retrograde trans-arterial implantation is contraindicated. We report on the short- and long-term implications of the apical-access-site-specific complications.
- 15 January 2011
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 40 (2)
Apical-access-related complications associated with trans-catheter aortic valve implantation.
The left-ventricular trans-apical access has become well established for trans-catheter aortic valve implantation, especially for patients in whom a retrograde trans-arterial implantation is contraindicated. We report on the short- and long-term implications of the apical-access-site-specific complications.
- 30 September 2010
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 140 (3) , 611-616
Intermittent regurgitation caused by incomplete leaflet closure of the Medtronic ADVANTAGE bileaflet heart valve: Analysis of the underlying mechanism
- 30 September 2010
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 140 (3) , 611-616
Intermittent regurgitation caused by incomplete leaflet closure of the Medtronic ADVANTAGE bileaflet heart valve: Analysis of the underlying mechanism
- 8 March 2010
- Published by Elsevier in International Journal of Cardiology
- Vol. 149 (2) , 221-226
Identification of an up-regulated anti-apoptotic network in the internal thoracic artery
- 8 March 2010
- Published by Elsevier in International Journal of Cardiology
- Vol. 149 (2) , 221-226
Identification of an up-regulated anti-apoptotic network in the internal thoracic artery
- 30 January 2009
- Published by Springer Nature in Zeitschrift für Herz-,Thorax- und Gefäßchirurgie
- Vol. 23 (1) , 2-8
Kathetergestützter Aortenklappenersatz: Alternative zur offenen Chirurgie bei Hochrisikopatienten
- 30 January 2009
- Published by Springer Nature in Zeitschrift für Herz-,Thorax- und Gefäßchirurgie
- Vol. 23 (1) , 2-8
Kathetergestützter Aortenklappenersatz: Alternative zur offenen Chirurgie bei Hochrisikopatienten
- 1 January 2009
- Vol. 18 (1) , 95-100
Hemodynamic characterization of the Sorin Mitroflow pericardial bioprosthesis at rest and exercise.
Although the long-term clinical outcome after aortic valve replacement (AVR) with the Sorin Mitroflow pericardial bioprosthesis has been well described, few data are available with regards to hemodynamic performance. On the basis of its specialized design, with the pericardium mounted on the outside of the stent, the Mitroflow valve is considered to provide optimal opening and orifice areas. Between February 2006 and April 2007, a total of 127 patients (66 females, 61 males; mean age 77.6 +/- 5.2 years) underwent AVR with the Mitroflow valve at the authors' institution. Echocardiography was performed at discharge in 91 patients, while a six-month follow up examination was conducted in 78 (including ergometer hemodynamics in 25 cases). The mean systolic pressure gradient (MPG) ranged from 19.7 +/- 3.3 mmHg (size 19 valve) to 12.4 +/- 2.4 mmHg (size 27 valve), and the mean effective orifice area (EOA) from 0.96 +/- 0.0 cm2 (size 19 valve) to 2.36 +/- 0.4 cm2 (size 27 valve). The incidence of mild-to-moderate and severe prosthesis-patient mismatch (PPM) was 33% and 10% at the six-month follow up. During exercise (25 W-100 W), the MPG increased from 17.1 +/- 3.6 mmHg to 23.6 mmHg in valve sizes 19 to 21, and from 12.2 +/- 3.6 mmHg to 15.9 +/- 2.5 mmHg in valve sizes 23 to 27. The effective orifice fraction (EOF = EOA/annulus area) was 38 +/- 7%. The Mitroflow valve exhibits an adequate MPG and EOA, as might be expected for a pericardial bioprosthesis. Of note, the gradient increase during exercise was low, especially for the larger valve sizes. Due to its special design, the Mitroflow prosthesis shows a large opening, as demonstrated by the high EOF. These data relating to the EOA of all prosthesis sizes may help surgeons to select the minimum prosthesis size in order to prevent PPM.
- 1 January 2009
- Vol. 18 (1) , 95-100
Hemodynamic characterization of the Sorin Mitroflow pericardial bioprosthesis at rest and exercise.
Although the long-term clinical outcome after aortic valve replacement (AVR) with the Sorin Mitroflow pericardial bioprosthesis has been well described, few data are available with regards to hemodynamic performance. On the basis of its specialized design, with the pericardium mounted on the outside of the stent, the Mitroflow valve is considered to provide optimal opening and orifice areas. Between February 2006 and April 2007, a total of 127 patients (66 females, 61 males; mean age 77.6 +/- 5.2 years) underwent AVR with the Mitroflow valve at the authors' institution. Echocardiography was performed at discharge in 91 patients, while a six-month follow up examination was conducted in 78 (including ergometer hemodynamics in 25 cases). The mean systolic pressure gradient (MPG) ranged from 19.7 +/- 3.3 mmHg (size 19 valve) to 12.4 +/- 2.4 mmHg (size 27 valve), and the mean effective orifice area (EOA) from 0.96 +/- 0.0 cm2 (size 19 valve) to 2.36 +/- 0.4 cm2 (size 27 valve). The incidence of mild-to-moderate and severe prosthesis-patient mismatch (PPM) was 33% and 10% at the six-month follow up. During exercise (25 W-100 W), the MPG increased from 17.1 +/- 3.6 mmHg to 23.6 mmHg in valve sizes 19 to 21, and from 12.2 +/- 3.6 mmHg to 15.9 +/- 2.5 mmHg in valve sizes 23 to 27. The effective orifice fraction (EOF = EOA/annulus area) was 38 +/- 7%. The Mitroflow valve exhibits an adequate MPG and EOA, as might be expected for a pericardial bioprosthesis. Of note, the gradient increase during exercise was low, especially for the larger valve sizes. Due to its special design, the Mitroflow prosthesis shows a large opening, as demonstrated by the high EOF. These data relating to the EOA of all prosthesis sizes may help surgeons to select the minimum prosthesis size in order to prevent PPM.
- 30 December 2008
- Published by Georg Thieme Verlag KG in Kardiologie up2date
- Vol. 4 (04) , 276-280
Bioengineering von Herzklappen
Clinically used valve prostheses are still associated with several limitations. The biological prostheses are limited due to their durability and mechanical valves need permanent oral anticoagulation. Tissue engineering could become a capable tool to create an „ideal” living heart valve with the potential to grow. This would be a matter of particular interest especially in paediatric patients. This article gives a short overview about current concepts, used cell types and clinical experiences with tissue engineered heart valves.
- 30 December 2008
- Published by Georg Thieme Verlag KG in Kardiologie up2date
- Vol. 4 (04) , 276-280
Bioengineering von Herzklappen
Clinically used valve prostheses are still associated with several limitations. The biological prostheses are limited due to their durability and mechanical valves need permanent oral anticoagulation. Tissue engineering could become a capable tool to create an „ideal” living heart valve with the potential to grow. This would be a matter of particular interest especially in paediatric patients. This article gives a short overview about current concepts, used cell types and clinical experiences with tissue engineered heart valves.
- 5 November 2008
- Published by Springer Nature
- p. 155-166
Cardiovascular Dynamics Following Open Heart Surgery: Early Impairment and Potential for Recovery
- 5 November 2008
- Published by Springer Nature
- p. 155-166
Cardiovascular Dynamics Following Open Heart Surgery: Early Impairment and Potential for Recovery