Eugen Gallasch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Eugen Gallasch has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Dietmar Rafolt
Institute of Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
2 shared publicationsMartin Fend
Department of Physiology, Medical University Graz, Graz, Austria
2 shared publicationsAndon Kossev
Institute of Biophysics, Bulgarian Academy of Sciences, Sofia, Bulgaria
1 shared publicationChristian M. Siedentopf
Department of Neuroradiology, Medical University Innsbruck, Innsbruck, Austria
1 shared publicationFlorian Koppelstaetter
Department of Neuroradiology, Medical University Innsbruck, Innsbruck, Austria
1 shared publicationFranz Gerstenbrand
Ludwig Boltzmann Institute for Restorative Neurology and Neuromodulation, Vienna, Austria
1 shared publication
Latest Publications
- 20 September 2008
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 105 (1) , 47-54
Changes in motor cortex excitability following training of a novel goal-directed motor task
Training of skilled movements leads to typical changes in motor evoked potentials (MEPs). To explore how such changes are related to motor performance and hand preference, a goal-directed movement task was implemented on a haptic interface. Right and left hands of right-handed subjects were trained in two sessions separated by a pause of 10 min. Transcranial magnetic stimulation (TMS) was applied contralaterally to the trained hand before and after each session. Effects of right hand training: after session #1 MEP-facilitation was +60%, intracortical inhibition (ICI) was reduced and task improvement was +37%. Following session #2 all variables remained unchanged. Left hand training: after session #1 MEP-facilitation was +59%, ICI remained unchanged and task improvement was +30%. Following session #2 all variables remained unchanged. It is concluded that mainly the early phase of skill acquisition induces neuroplastic changes. The asymmetry in ICI obviously reflects functional side differences in hand motor control.
- 20 September 2008
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 105 (1) , 47-54
Changes in motor cortex excitability following training of a novel goal-directed motor task
Training of skilled movements leads to typical changes in motor evoked potentials (MEPs). To explore how such changes are related to motor performance and hand preference, a goal-directed movement task was implemented on a haptic interface. Right and left hands of right-handed subjects were trained in two sessions separated by a pause of 10 min. Transcranial magnetic stimulation (TMS) was applied contralaterally to the trained hand before and after each session. Effects of right hand training: after session #1 MEP-facilitation was +60%, intracortical inhibition (ICI) was reduced and task improvement was +37%. Following session #2 all variables remained unchanged. Left hand training: after session #1 MEP-facilitation was +59%, ICI remained unchanged and task improvement was +30%. Following session #2 all variables remained unchanged. It is concluded that mainly the early phase of skill acquisition induces neuroplastic changes. The asymmetry in ICI obviously reflects functional side differences in hand motor control.
- Open Access
- 9 October 2006
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 24 (5) , 1177-1182
Contact force‐ and amplitude‐controllable vibrating probe for somatosensory mapping of plantar afferences with fMRI
Purpose: To study cerebral responses evoked from mechanoreceptors in the human foot sole using a computer‐controlled vibrotactile stimulation system.Materials and Methods: The stimulation system consisted of two stationary moving magnet actuators with indentors to gently contact and vibrate the foot sole during functional MRI (fMRI) experiments. To allow independent settings of contact force (0–20 N) and intensity of vibration (frequency range = 20–100 Hz) the actuators were controlled by a digital servo loop. For fMRI experiments with complex stimulus protocols, both vibrating probes were further operated under supervisory control.Results: The MR compatibility of this electromagnetic system was tested in a 1.5T scanner with an actively shielded magnet (Siemens Magnetom Sonata). Blood oxygenation level‐dependent (BOLD) responses were detected in the contralateral left pre‐ and postcentral gyrus, bilaterally within the secondary somatosensory cortex, bilaterally within the supplementary motor cortex, and bilaterally within the anterior cingular gyrus.Conclusion: This stimulation device provides a new tool for identifying cerebral structures that convey sensory information from the foot region, which is of promising diagnostic value, particularly for assessing sensorimotor deficits resulting from brain lesions. J. Magn. Reson. Imaging 2006.
- 9 October 2006
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 24 (5) , 1177-1182
Open AccessContact force‐ and amplitude‐controllable vibrating probe for somatosensory mapping of plantar afferences with fMRI
Purpose: To study cerebral responses evoked from mechanoreceptors in the human foot sole using a computer‐controlled vibrotactile stimulation system.Materials and Methods: The stimulation system consisted of two stationary moving magnet actuators with indentors to gently contact and vibrate the foot sole during functional MRI (fMRI) experiments. To allow independent settings of contact force (0–20 N) and intensity of vibration (frequency range = 20–100 Hz) the actuators were controlled by a digital servo loop. For fMRI experiments with complex stimulus protocols, both vibrating probes were further operated under supervisory control.Results: The MR compatibility of this electromagnetic system was tested in a 1.5T scanner with an actively shielded magnet (Siemens Magnetom Sonata). Blood oxygenation level‐dependent (BOLD) responses were detected in the contralateral left pre‐ and postcentral gyrus, bilaterally within the secondary somatosensory cortex, bilaterally within the supplementary motor cortex, and bilaterally within the anterior cingular gyrus.Conclusion: This stimulation device provides a new tool for identifying cerebral structures that convey sensory information from the foot region, which is of promising diagnostic value, particularly for assessing sensorimotor deficits resulting from brain lesions. J. Magn. Reson. Imaging 2006.
- 22 February 2005
- Published by Wiley in Artificial Organs
- Vol. 29 (3) , 207-211
Evaluation of FES‐Induced Knee Joint Moments in Paraplegics with Denervated Muscles
Abstract: The pendulum test was applied to evaluate functional electrical stimulation (FES)‐induced joint moments in paraplegics with denervated muscles. Therefore a manipulandum was connected to the knee joint and programmed to elicit gravity‐induced leg oscillations. The FES‐induced output torque was compensated for in order to keep the leg in a mean vertical position (knee angle 90°). A second‐order dynamical model was applied to extract the elastic and viscous moments from the recorded leg oscillations. This model provided an almost adequate description of the relaxed and FES‐contracted states. In the relaxed state the elastic moment was 15.3 ± 2.37 Nm/rad and the viscous moment was 0.41 ± 0.21 Nms/rad. The FES‐induced elastic moment was 29.4 ± 28.5 Nm/rad and the FES‐induced viscous moment was 1.53 ± 1.03 Nms/rad (N = 10, before FES‐training).
- 22 February 2005
- Published by Wiley in Artificial Organs
- Vol. 29 (3) , 207-211
Evaluation of FES‐Induced Knee Joint Moments in Paraplegics with Denervated Muscles
Abstract: The pendulum test was applied to evaluate functional electrical stimulation (FES)‐induced joint moments in paraplegics with denervated muscles. Therefore a manipulandum was connected to the knee joint and programmed to elicit gravity‐induced leg oscillations. The FES‐induced output torque was compensated for in order to keep the leg in a mean vertical position (knee angle 90°). A second‐order dynamical model was applied to extract the elastic and viscous moments from the recorded leg oscillations. This model provided an almost adequate description of the relaxed and FES‐contracted states. In the relaxed state the elastic moment was 15.3 ± 2.37 Nm/rad and the viscous moment was 0.41 ± 0.21 Nms/rad. The FES‐induced elastic moment was 29.4 ± 28.5 Nm/rad and the FES‐induced viscous moment was 1.53 ± 1.03 Nms/rad (N = 10, before FES‐training).