Fumiaki Kura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Fumiaki Kura has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Junko Amemura-Maekawa
Department of Bacteriology I, National Institute of Infectious Diseases, Tokyo, Japan
2 shared publications - Akihiro Sato
Department of Infection Prevention and Control, Tokyo Medical University Hospital, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
1 shared publication E. Ishii
Department of Microbiology, Osaka City Institute of Public Health and Environmental Sciences, Osaka, Japan
1 shared publicationH. Tsuji
Department of infectious Diseases, Hyogo Prefectural Institute of Public Health and Environmental Sciences, Kobe, Japan
1 shared publicationH. Watanabe
Department of Bacteriology, National Institute of Infectious Diseases, Tokyo, Japan
1 shared publicationHaruo Watanabe
Department of Bacteriology, National Institute of Infectious Diseases, Tokyo 162-8640, Japan
1 shared publication
Latest Publications
- Open Access
- 17 July 2021
- Published by Springer Nature in BMC Microbiology
- Vol. 21 (1) , 1-12
Detection of Legionella species, the influence of precipitation on the amount of Legionella DNA, and bacterial microbiome in aerosols from outdoor sites near asphalt roads in Toyama Prefecture, Japan
Background: Legionellosis is caused by the inhalation of aerosolized water contaminated withLegionellabacteria. In this study, we investigated the prevalence ofLegionellaspecies in aerosols collected from outdoor sites near asphalt roads, bathrooms in public bath facilities, and other indoor sites, such as buildings and private homes, using amoebic co-culture, quantitative PCR, and 16S rRNA gene amplicon sequencing.Results: Legionellaspecies were not detected by amoebic co-culture. However,LegionellaDNA was detected in 114/151 (75.5%) air samples collected near roads (geometric mean ± standard deviation: 1.80 ± 0.52 log10copies/m3), which was comparable to the numbers collected from bathrooms [15/21 (71.4%), 1.82 ± 0.50] but higher than those collected from other indoor sites [11/30 (36.7%), 0.88 ± 0.56] (P < 0.05). The amount ofLegionellaDNA was correlated with the monthly total precipitation (r = 0.56,P < 0.01). It was also directly and inversely correlated with the daily total precipitation for seven days (r = 0.21,P = 0.01) and one day (r = − 0.29,P < 0.01) before the sampling day, respectively. 16S rRNA gene amplicon sequencing revealed thatLegionellaspecies were detected in 9/30 samples collected near roads (mean proportion of reads, 0.11%). At the species level,L. pneumophilawas detected in 2/30 samples collected near roads (the proportion of reads, 0.09 and 0.11% of the total reads number in each positive sample). The three most abundant bacterial genera in the samples collected near roads wereSphingomonas,Streptococcus, andMethylobacterium(mean proportion of reads; 21.1%, 14.6%, and 1.6%, respectively). In addition, the bacterial diversity in outdoor environment was comparable to that in indoor environment which contains aerosol-generating features and higher than that in indoor environment without the features.Conclusions: DNA fromLegionellaspecies was widely present in aerosols collected from outdoor sites near asphalt roads, especially during the rainy season. Our findings suggest that there may be a risk of exposure toLegionellaspecies not only in bathrooms but also in the areas surrounding asphalt roads. Therefore, the possibility of contracting legionellosis in daily life should be considered.
- 17 July 2021
- Published by Springer Nature in BMC Microbiology
- Vol. 21 (1) , 1-12
Open AccessDetection of Legionella species, the influence of precipitation on the amount of Legionella DNA, and bacterial microbiome in aerosols from outdoor sites near asphalt roads in Toyama Prefecture, Japan
Background: Legionellosis is caused by the inhalation of aerosolized water contaminated withLegionellabacteria. In this study, we investigated the prevalence ofLegionellaspecies in aerosols collected from outdoor sites near asphalt roads, bathrooms in public bath facilities, and other indoor sites, such as buildings and private homes, using amoebic co-culture, quantitative PCR, and 16S rRNA gene amplicon sequencing.Results: Legionellaspecies were not detected by amoebic co-culture. However,LegionellaDNA was detected in 114/151 (75.5%) air samples collected near roads (geometric mean ± standard deviation: 1.80 ± 0.52 log10copies/m3), which was comparable to the numbers collected from bathrooms [15/21 (71.4%), 1.82 ± 0.50] but higher than those collected from other indoor sites [11/30 (36.7%), 0.88 ± 0.56] (P < 0.05). The amount ofLegionellaDNA was correlated with the monthly total precipitation (r = 0.56,P < 0.01). It was also directly and inversely correlated with the daily total precipitation for seven days (r = 0.21,P = 0.01) and one day (r = − 0.29,P < 0.01) before the sampling day, respectively. 16S rRNA gene amplicon sequencing revealed thatLegionellaspecies were detected in 9/30 samples collected near roads (mean proportion of reads, 0.11%). At the species level,L. pneumophilawas detected in 2/30 samples collected near roads (the proportion of reads, 0.09 and 0.11% of the total reads number in each positive sample). The three most abundant bacterial genera in the samples collected near roads wereSphingomonas,Streptococcus, andMethylobacterium(mean proportion of reads; 21.1%, 14.6%, and 1.6%, respectively). In addition, the bacterial diversity in outdoor environment was comparable to that in indoor environment which contains aerosol-generating features and higher than that in indoor environment without the features.Conclusions: DNA fromLegionellaspecies was widely present in aerosols collected from outdoor sites near asphalt roads, especially during the rainy season. Our findings suggest that there may be a risk of exposure toLegionellaspecies not only in bathrooms but also in the areas surrounding asphalt roads. Therefore, the possibility of contracting legionellosis in daily life should be considered.
- Open Access
- 1 April 2020
- Published by Elsevier in International Journal of Infectious Diseases
- Vol. 93, 300-304
Persistent Legionella contamination of water faucets in a tertiary hospital in Japan
- 1 April 2020
- Published by Elsevier in International Journal of Infectious Diseases
- Vol. 93, 300-304
Open AccessPersistent Legionella contamination of water faucets in a tertiary hospital in Japan
- 5 September 2005
- Published by Cambridge University Press (CUP) in Epidemiology and Infection
- Vol. 134 (2) , 385-391
Outbreak of Legionnaires' disease on a cruise ship linked to spa-bath filter stones contaminated with Legionella pneumophila serogroup 5
In January 2003, two cases of Legionnaires' disease associated with a ship's cruise were registered in the database of National Epidemiological Surveillance of Infectious Diseases. A 70-year-old male heavy smoker with mild emphysema contracted the disease during a cruise. Legionella pneumophila serogroup (sg) 5 was isolated from the patient's sputum and the ship's indoor spa. The isolate from the spa matched the patient's isolate by genotyping performed by pulsed-field gel electrophoresis (PFGE). The second case was in a 73-year-old female. During epidemiological investigation, a third case of Legionnaire's disease in a 71-year-old male was subsequently diagnosed among passengers on the same ship on the following cruise. Environmental investigation revealed that porous natural stones (Maifanshi) in the filters of the spas had harboured L. pneumophila, a phenomenon which has not been reported except in Japan. This is the first documented evidence of L. pneumophila sg 5 infection on a ship and of porous stones as a source of Legionella infection.
- 5 September 2005
- Published by Cambridge University Press (CUP) in Epidemiology and Infection
- Vol. 134 (2) , 385-391
Outbreak of Legionnaires' disease on a cruise ship linked to spa-bath filter stones contaminated with Legionella pneumophila serogroup 5
In January 2003, two cases of Legionnaires' disease associated with a ship's cruise were registered in the database of National Epidemiological Surveillance of Infectious Diseases. A 70-year-old male heavy smoker with mild emphysema contracted the disease during a cruise. Legionella pneumophila serogroup (sg) 5 was isolated from the patient's sputum and the ship's indoor spa. The isolate from the spa matched the patient's isolate by genotyping performed by pulsed-field gel electrophoresis (PFGE). The second case was in a 73-year-old female. During epidemiological investigation, a third case of Legionnaire's disease in a 71-year-old male was subsequently diagnosed among passengers on the same ship on the following cruise. Environmental investigation revealed that porous natural stones (Maifanshi) in the filters of the spas had harboured L. pneumophila, a phenomenon which has not been reported except in Japan. This is the first documented evidence of L. pneumophila sg 5 infection on a ship and of porous stones as a source of Legionella infection.
- Open Access
- 1 May 2003
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 41 (5) , 2227-2229
Neonatal Sudden Death Due to Legionella Pneumonia Associated with Water Birth in a Domestic Spa Bath
We report the first case of neonatal Legionnaires' disease associated with water birth in a spa bath at home. Legionella pneumophila serogroup 6 was detected from postmortem lung tissue.
- 1 May 2003
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 41 (5) , 2227-2229
Open AccessNeonatal Sudden Death Due to Legionella Pneumonia Associated with Water Birth in a Domestic Spa Bath
We report the first case of neonatal Legionnaires' disease associated with water birth in a spa bath at home. Legionella pneumophila serogroup 6 was detected from postmortem lung tissue.