Ali Shaibani
Research Subjects
Ali Shaibani has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Eric J. Russell
Department of Radiology, Northwestern University, 676 North Saint Clair Street, Suite 800, Chicago, Ill 60611
4 shared publicationsAjay K. Wakhloo
3 shared publicationsBernard Bendok
2 shared publications- Bernard R. Bendok
Department of Neurological Surgery, Mayo Clinic, Phoenix, Arizona, USA
2 shared publications Hunt H. Batjer
2 shared publications- Mark Jay Alberts
Northwestern University, Feinberg School of Medicine, 710 N Lake Shore Drive, Chicago, IL 60611, USA
2 shared publications
Latest Publications
- 1 May 2018
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of neurosurgery. Pediatrics
- Vol. 21 (5) , 466-470
MynxGrip vascular closure device use in pediatric neurointerventional procedures
OBJECTIVE: The aim of this paper was assess the efficacy and safety of using the MynxGrip arterial closure device in pediatric neuroendovascular procedures where the use of closure devices remains off-label despite their validation and widespread use in adults.METHODS: A retrospective review of all pediatric patients who underwent diagnostic or interventional neuroendovascular procedures at the authors’ institution was performed. MynxGrip use was predicated by an adequate depth of subcutaneous tissue and common femoral artery (CFA) diameter. Patients remained on supine bedrest for 2 hours after diagnostic procedures and for 3 hours after therapeutic procedures. Patient demographics, procedural details, hemostasis status, and complications were recorded.RESULTS: Over 36 months, 83 MynxGrip devices were deployed in 53 patients (23 male and 30 female patients; mean age 14 years) who underwent neuroendovascular procedures. The right-side CFA was the main point of access for most procedures. The mean CFA diameter was 6.24 mm and ranged from 4 mm to 8.5 mm. Diagnostic angiography comprised 46% of the procedures. A single device failure occurred without any sequelae; the device was extracted, and hemostasis was achieved by manual compression with the placement of a Safeguard compression device. No other immediate or delayed major complications were recorded.CONCLUSIONS: MynxGrip can be used safely in the pediatric population for effective hemostasis and has the advantage of earlier mobilization.
- 1 May 2018
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of neurosurgery. Pediatrics
- Vol. 21 (5) , 466-470
MynxGrip vascular closure device use in pediatric neurointerventional procedures
OBJECTIVE: The aim of this paper was assess the efficacy and safety of using the MynxGrip arterial closure device in pediatric neuroendovascular procedures where the use of closure devices remains off-label despite their validation and widespread use in adults.METHODS: A retrospective review of all pediatric patients who underwent diagnostic or interventional neuroendovascular procedures at the authors’ institution was performed. MynxGrip use was predicated by an adequate depth of subcutaneous tissue and common femoral artery (CFA) diameter. Patients remained on supine bedrest for 2 hours after diagnostic procedures and for 3 hours after therapeutic procedures. Patient demographics, procedural details, hemostasis status, and complications were recorded.RESULTS: Over 36 months, 83 MynxGrip devices were deployed in 53 patients (23 male and 30 female patients; mean age 14 years) who underwent neuroendovascular procedures. The right-side CFA was the main point of access for most procedures. The mean CFA diameter was 6.24 mm and ranged from 4 mm to 8.5 mm. Diagnostic angiography comprised 46% of the procedures. A single device failure occurred without any sequelae; the device was extracted, and hemostasis was achieved by manual compression with the placement of a Safeguard compression device. No other immediate or delayed major complications were recorded.CONCLUSIONS: MynxGrip can be used safely in the pediatric population for effective hemostasis and has the advantage of earlier mobilization.
- 1 January 2011
- Published by Elsevier
- p. 1655-1687
Vascular Anatomy of the Spine, Imaging, and Endovascular Treatment of Spinal Vascular Diseases
- 1 January 2011
- Published by Elsevier
- p. 1655-1687
Vascular Anatomy of the Spine, Imaging, and Endovascular Treatment of Spinal Vascular Diseases
- 31 October 2007
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 18 (10) , 1297-1299
Fracture of a Nitinol Carotid Artery Stent That Caused Restenosis
- 31 October 2007
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 18 (10) , 1297-1299
Fracture of a Nitinol Carotid Artery Stent That Caused Restenosis
- 30 June 2007
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 18 (6) , 785-788
Pulsatility Imaging of Saccular Aneurysm Model by 64-Slice CT with Dynamic Multiscan Technique
- 30 June 2007
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 18 (6) , 785-788
Pulsatility Imaging of Saccular Aneurysm Model by 64-Slice CT with Dynamic Multiscan Technique
- 1 December 2004
- Vol. 25 (10) , 1807-1811
Rheolytic Catheter Thrombectomy, Balloon Angioplasty, and Direct Recombinant Tissue Plasminogen Activator Thrombolysis of Dural Sinus Thrombosis with Preexisting Hemorrhagic Infarctions
Summary: We describe the case of a 28-year-old obtunded woman who presented with bilateral anterior parietal lobe cortical hemorrhages associated with thrombosis of the superior sagittal sinus, both transverse and sigmoid sinuses, and multiple cortical veins draining into the sagittal sinus. Initial heparin therapy was not effective. A combination of AngioJet rheolytic catheter thrombectomy, balloon angioplasty, and continuous direct superior sagittal sinus recombinant tissue plasminogen activator infusion led to venous recanalization with a successful clinical outcome, without worsening of the preexisting intracranial hemorrhages.
- 1 December 2004
- Vol. 25 (10) , 1807-1811
Rheolytic Catheter Thrombectomy, Balloon Angioplasty, and Direct Recombinant Tissue Plasminogen Activator Thrombolysis of Dural Sinus Thrombosis with Preexisting Hemorrhagic Infarctions
Summary: We describe the case of a 28-year-old obtunded woman who presented with bilateral anterior parietal lobe cortical hemorrhages associated with thrombosis of the superior sagittal sinus, both transverse and sigmoid sinuses, and multiple cortical veins draining into the sagittal sinus. Initial heparin therapy was not effective. A combination of AngioJet rheolytic catheter thrombectomy, balloon angioplasty, and continuous direct superior sagittal sinus recombinant tissue plasminogen activator infusion led to venous recanalization with a successful clinical outcome, without worsening of the preexisting intracranial hemorrhages.
- 1 December 2004
- Published by Elsevier in Seminars in Cerebrovascular Diseases and Stroke
- Vol. 4 (4) , 176-194
Endovascular Treatment of Dural Arteriovenous Shunts
- 1 December 2004
- Published by Elsevier in Seminars in Cerebrovascular Diseases and Stroke
- Vol. 4 (4) , 176-194
Endovascular Treatment of Dural Arteriovenous Shunts
- 1 September 2004
- Vol. 25 (8) , 1384-1386
Temporary Balloon Occlusion to Test Adequacy of Collateral Flow to the Retina and Tolerance for Endovascular Aneurysmal Coiling
Summary: Two carotid ophthalmic artery aneurysms with incorporation of the artery into the neck were referred for endovascular assessment. Temporary balloon occlusion at the aneurysm neck was performed in an attempt to assess the adequacy of collateral flow to the retina. During inflation, the patients reported visual deterioration that resolved upon deflation, which indicates that collateral blood flow was insufficient. The patients were referred for surgical clipping to ensure preservation of the ophthalmic artery.
- 1 September 2004
- Vol. 25 (8) , 1384-1386
Temporary Balloon Occlusion to Test Adequacy of Collateral Flow to the Retina and Tolerance for Endovascular Aneurysmal Coiling
Summary: Two carotid ophthalmic artery aneurysms with incorporation of the artery into the neck were referred for endovascular assessment. Temporary balloon occlusion at the aneurysm neck was performed in an attempt to assess the adequacy of collateral flow to the retina. During inflation, the patients reported visual deterioration that resolved upon deflation, which indicates that collateral blood flow was insufficient. The patients were referred for surgical clipping to ensure preservation of the ophthalmic artery.
- 1 June 2004
- Published by Wolters Kluwer Health in Contemporary Neurosurgery
- Vol. 26 (13) , 1-5
Update on Carotid Artery Stenting
- 1 June 2004
- Published by Wolters Kluwer Health in Contemporary Neurosurgery
- Vol. 26 (13) , 1-5
Update on Carotid Artery Stenting
- 1 June 2004
- Published by Wolters Kluwer Health in Contemporary Neurosurgery
- Vol. 26 (12) , 1-4
Update on Carotid Artery Stenting
- 1 June 2004
- Published by Wolters Kluwer Health in Contemporary Neurosurgery
- Vol. 26 (12) , 1-4
Update on Carotid Artery Stenting