Monica Berry
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Monica Berry has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Maria Carmen Galan
Departamento de Construcciones Arquitectónicas I, Escuela Técnica Superior de Arquitectura, Universidad de Sevilla, Seville, Spain
3 shared publications Anthony P. Corfield
University of Bristol, School of Physics, NSQI, Tyndall Avenue, Bristol BS8 1FD, UK
2 shared publications- Bo Hou
School of Physics and Astronomy, Cardiff University, Cardiff, CF24 3AA, UK
2 shared publications David Benito-Alifonso
School of Chemistry, University of Bristol, Cantock's Close, BS8 1TS, UK.
2 shared publicationsDavid J. Fermin
School of Chemistry, University of Bristol, Cantock's Close, Bristol BS8 1TS (UK)
2 shared publicationsHarriet Lockyear
School of Chemistry, University of Bristol, Cantock's Close, Bristol BS8 1TS (UK)
2 shared publications
Latest Publications
- Open Access
- 7 March 2016
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 52 (27) , 4906-4909
Imidazolium-tagged glycan probes for non-covalent labeling of live cells
Selective, bioorthogonal and fast labeling of glycoconjugates in living cells is a major challenge for synthetic and cellular biology. Here we report the use imidazolium tagged-mannosamine derivative (ITag-Man) for the non-covalent, rapid and site-specific labeling of sialic acid containing glycoproteins using commercial N-nitrilotriacetate fluorescent reagents in a range of cell lines.
- 7 March 2016
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 52 (27) , 4906-4909
Open AccessImidazolium-tagged glycan probes for non-covalent labeling of live cells
Selective, bioorthogonal and fast labeling of glycoconjugates in living cells is a major challenge for synthetic and cellular biology. Here we report the use imidazolium tagged-mannosamine derivative (ITag-Man) for the non-covalent, rapid and site-specific labeling of sialic acid containing glycoproteins using commercial N-nitrilotriacetate fluorescent reagents in a range of cell lines.
- 1 July 2015
- Published by Elsevier in Trends in Biochemical Sciences
- Vol. 40 (7) , 351-359
Glycan variation and evolution in the eukaryotes
- 1 July 2015
- Published by Elsevier in Trends in Biochemical Sciences
- Vol. 40 (7) , 351-359
Glycan variation and evolution in the eukaryotes
- Open Access
- 5 December 2013
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 53 (3) , 810-814
Lactose as a “Trojan Horse” for Quantum Dot Cell Transport
A series of glycan‐coated quantum dots were prepared to probe the effect of glycan presentation in intracellular localization in HeLa and SV40 epithelial cells. We show that glycan density mostly impacts on cell toxicity, whereas glycan type affects the cell uptake and intracellular localization. Moreover, we show that lactose can act as a “Trojan horse” on bi‐functionalized QDs to help intracellular delivery of other non‐internalizable glycan moieties and largely avoid the endosomal/lysosomal degradative pathway.
- 5 December 2013
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 53 (3) , 810-814
Open AccessLactose as a “Trojan Horse” for Quantum Dot Cell Transport
A series of glycan‐coated quantum dots were prepared to probe the effect of glycan presentation in intracellular localization in HeLa and SV40 epithelial cells. We show that glycan density mostly impacts on cell toxicity, whereas glycan type affects the cell uptake and intracellular localization. Moreover, we show that lactose can act as a “Trojan horse” on bi‐functionalized QDs to help intracellular delivery of other non‐internalizable glycan moieties and largely avoid the endosomal/lysosomal degradative pathway.
- Open Access
- 5 December 2013
- Published by Wiley in Angewandte Chemie
- Vol. 126 (3) , 829-833
Lactose as a “Trojan Horse” for Quantum Dot Cell Transport
- 5 December 2013
- Published by Wiley in Angewandte Chemie
- Vol. 126 (3) , 829-833
Open AccessLactose as a “Trojan Horse” for Quantum Dot Cell Transport
- 1 January 2013
- Published by Springer Nature
- p. 1615-1618
Mucin Biophysics
- 10 December 2012
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 9 (6) , 1740-1743
Mucins: a dynamic biology
In this highlight, we discuss the multifaceted biology of mucins, where molecular architecture meets function, and especially the collective properties of mucin networks and gels that select adherent bacteria and restrict penetration.
- 10 December 2012
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 9 (6) , 1740-1743
Mucins: a dynamic biology
In this highlight, we discuss the multifaceted biology of mucins, where molecular architecture meets function, and especially the collective properties of mucin networks and gels that select adherent bacteria and restrict penetration.
- 1 October 2008
- Published by Wiley in Optometry and Vision Science
- Vol. 85 (10) , E930-8
Mucins and Ocular Signs in Symptomatic and Asymptomatic Contact Lens Wear
Purpose.: Lid wiper epitheliopathy (LWE) and lid parallel conjunctival folds (LIPCOF) are related to dry eye symptoms in contact lens wearers. Both clinical signs are assumed to be related to mechanical forces during blinking. As the mucus layer is a protector of the ocular surface tissue, this study investigates whether any alterations of mucins are detectable comparing symptomatic and asymptomatic soft contact lens wearers. Methods.: Comfort was evaluated using the Contact Lens Dry Eye Questionnaire. Corneal staining, LWE, and LIPCOF were assessed in the right eyes of 50 (19 men, 31 women; mean age, 32.1 ± 11.4 years) experienced lens wearers. The tear film was sampled using Schirmer strips pressed onto the temporal conjunctiva and from harvested contact lenses. Mucins were assessed in dot‐blots and Western blots after electrophoresis on 1% agarose or 4 to 12% NuPAGE Gels. Non‐parametric analyses were used to study differences between groups and correlations between objective tests, mucins, and symptoms. Results.: Thirty‐one subjects were classified asymptomatic and 19 symptomatic by the questionnaire. LWE and LIPCOF were significantly increased in the symptomatic group (p < 0.035). MUC5AC reactivity was significantly decreased in symptomatics (p = 0.050). MUC4 was correlated to temporal LIPCOF and LWE, (r = −0.47 and −0.46; p < 0.01). MUC16 and MUC5AC correlated with corneal staining (0.36 < r < 0.53; p < 0.04). Conclusions.: Symptomatic contact lens wearers exhibit significantly more LWE and LIPCOF, and decreased MUC5AC reactivity. LWE and LIPCOF are significantly correlated; this may reflect their common frictional origin. Increased friction might follow from insufficient mucins, or an altered composition of the resident mucins at the ocular surface. In this study, we show that decreased mucin production is associated with the severity of LWE and LIPCOF.
- 1 October 2008
- Published by Wiley in Optometry and Vision Science
- Vol. 85 (10) , E930-8
Mucins and Ocular Signs in Symptomatic and Asymptomatic Contact Lens Wear
Purpose.: Lid wiper epitheliopathy (LWE) and lid parallel conjunctival folds (LIPCOF) are related to dry eye symptoms in contact lens wearers. Both clinical signs are assumed to be related to mechanical forces during blinking. As the mucus layer is a protector of the ocular surface tissue, this study investigates whether any alterations of mucins are detectable comparing symptomatic and asymptomatic soft contact lens wearers. Methods.: Comfort was evaluated using the Contact Lens Dry Eye Questionnaire. Corneal staining, LWE, and LIPCOF were assessed in the right eyes of 50 (19 men, 31 women; mean age, 32.1 ± 11.4 years) experienced lens wearers. The tear film was sampled using Schirmer strips pressed onto the temporal conjunctiva and from harvested contact lenses. Mucins were assessed in dot‐blots and Western blots after electrophoresis on 1% agarose or 4 to 12% NuPAGE Gels. Non‐parametric analyses were used to study differences between groups and correlations between objective tests, mucins, and symptoms. Results.: Thirty‐one subjects were classified asymptomatic and 19 symptomatic by the questionnaire. LWE and LIPCOF were significantly increased in the symptomatic group (p < 0.035). MUC5AC reactivity was significantly decreased in symptomatics (p = 0.050). MUC4 was correlated to temporal LIPCOF and LWE, (r = −0.47 and −0.46; p < 0.01). MUC16 and MUC5AC correlated with corneal staining (0.36 < r < 0.53; p < 0.04). Conclusions.: Symptomatic contact lens wearers exhibit significantly more LWE and LIPCOF, and decreased MUC5AC reactivity. LWE and LIPCOF are significantly correlated; this may reflect their common frictional origin. Increased friction might follow from insufficient mucins, or an altered composition of the resident mucins at the ocular surface. In this study, we show that decreased mucin production is associated with the severity of LWE and LIPCOF.
- Open Access
- 1 October 2005
- Published by BMJ in British Journal of Ophthalmology
- Vol. 89 (10) , 1387
Immunology of the lacrimal gland, tear film and ocular surface
A short quotation (p 152) summarises the book: “These systems are all part of the multiple and redundant and protective mechanisms…[that] maintain a functioning cornea.” Reflecting this complexity, chapters range from the pathogenesis of herpetic keratitis to dry eyes, to mucosal immunity and the use of topical ciclosporin, to tear film and contact lenses and, of course, inflammation. The book includes more unusual chapters on ocular surface: these integrate the eye into the upper aerodigestive tract. Parallels between lacrimal and salivary glands, which are not often conducted, focus attention to the inflammatory and immune processes common to these mucosae and the diagnostic markers they might offer.
- 1 October 2005
- Published by BMJ in British Journal of Ophthalmology
- Vol. 89 (10) , 1387
Open AccessImmunology of the lacrimal gland, tear film and ocular surface
A short quotation (p 152) summarises the book: “These systems are all part of the multiple and redundant and protective mechanisms…[that] maintain a functioning cornea.” Reflecting this complexity, chapters range from the pathogenesis of herpetic keratitis to dry eyes, to mucosal immunity and the use of topical ciclosporin, to tear film and contact lenses and, of course, inflammation. The book includes more unusual chapters on ocular surface: these integrate the eye into the upper aerodigestive tract. Parallels between lacrimal and salivary glands, which are not often conducted, focus attention to the inflammatory and immune processes common to these mucosae and the diagnostic markers they might offer.
- Open Access
- 1 November 2004
- Published by BMJ in British Journal of Ophthalmology
- Vol. 88 (11) , 1460-1466
Dynamic molecular resolution imaging of preocular fluid impressions
Aim: The preocular fluid is renewed with molecules secreted by the underlying cells and with lacrimal gland secretions, while maintaining a stable surface topography. The authors tested the hypothesis that interactions between gelled and newly inserted mucins are the key to this stability. Methods: Using atomic force microscopy, the authors studied the topography of the freshly isolated preocular fluid obtained by impression cytology. The effects of adding mucins to this impression were compared with adding mucins to a pure mucin macromolecular assembly as a single component control to the more complex preocular fluid. The control structure was built up by repeated addition of pure ocular mucin to a tethering surface. Results: Imaging at molecular resolution showed a thin layer of superficial preocular fluid with an appearance consistent with a gel that was very flat, with surface roughness of approximately 0.1 nm. Mucin molecules adhering to a clean flat surface maintained their individual character when overlapping, whereas molecules integrating in the impression could not be followed individually. Both the preocular impression and the pure mucin assembly were stable under imaging for at least 90 minutes. The roughness of the pure mucin network decreased as more mucin was added. In contrast, there was a small increase in the roughness of the 2.25 μm2 area of impression over the 60 minutes of continuous imaging, although locally there appeared to be infill of low height features. Disulphide bond breaking resulted in the collapse of the imaged structure in both the pure mucin control and the more complex ex vivo preocular impression. Conclusions: Polymeric mucins linked by disulphide bonds prevent or lessen loss of ocular surface material into the surrounding aqueous tears.
- 1 November 2004
- Published by BMJ in British Journal of Ophthalmology
- Vol. 88 (11) , 1460-1466
Open AccessDynamic molecular resolution imaging of preocular fluid impressions
Aim: The preocular fluid is renewed with molecules secreted by the underlying cells and with lacrimal gland secretions, while maintaining a stable surface topography. The authors tested the hypothesis that interactions between gelled and newly inserted mucins are the key to this stability. Methods: Using atomic force microscopy, the authors studied the topography of the freshly isolated preocular fluid obtained by impression cytology. The effects of adding mucins to this impression were compared with adding mucins to a pure mucin macromolecular assembly as a single component control to the more complex preocular fluid. The control structure was built up by repeated addition of pure ocular mucin to a tethering surface. Results: Imaging at molecular resolution showed a thin layer of superficial preocular fluid with an appearance consistent with a gel that was very flat, with surface roughness of approximately 0.1 nm. Mucin molecules adhering to a clean flat surface maintained their individual character when overlapping, whereas molecules integrating in the impression could not be followed individually. Both the preocular impression and the pure mucin assembly were stable under imaging for at least 90 minutes. The roughness of the pure mucin network decreased as more mucin was added. In contrast, there was a small increase in the roughness of the 2.25 μm2 area of impression over the 60 minutes of continuous imaging, although locally there appeared to be infill of low height features. Disulphide bond breaking resulted in the collapse of the imaged structure in both the pure mucin control and the more complex ex vivo preocular impression. Conclusions: Polymeric mucins linked by disulphide bonds prevent or lessen loss of ocular surface material into the surrounding aqueous tears.
- 1 February 2003
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 44 (2) , 567-572
Patterns of Mucin Adherence to Contact Lenses
Purpose. Contact lens wear alters the preocular fluid through factors that include tear deposits on the lens. In the current study, lens-adherent material was extracted to assess whether contact lenses sample mucins from the preocular fluid. methods. Discarded extended-wear contact lenses were collected from patients with no ocular surface disease. Mucins were extracted in guanidine hydrochloride (GuHCl) with protease inhibitors. After the supernatant was removed, the extraction was repeated twice with the addition of 10 mM dithiothreitol, making a total of three extractions. Mucins were isolated by cesium chloride (CsCl) gradient centrifugation and size fractionated on Sepharose CL2B. Charge distribution was analyzed on ion-exchange chromatography with a lithium perchlorate (LiClO4) gradient. results. Contact lens–adherent mucins comprised soluble mucins and mucins that required solubilization by (repeated) dithiothreitol treatment. MUC1, MUC4, MUC2, and MUC5AC mucins eluted mainly at low buoyant densities in extractions from lenses worn long term without disinfection and at successively higher buoyant densities from monthly disposable contact lenses. Mucins with little negative charge, which were observed in all extractions, and very highly negatively charged species, present in the second and third extractions from contact lenses, had no equivalents in tissue-extracted mucins. conclusions. Mucins adhering to contact lenses are altered forms of intracellular mucins. Different degrees of adherence of mucins to contact lenses may occur, either because of mucin characteristics or after mucin complexation with adherent materials. In the context of good contact lens hygiene, their presence may offer some protection from toxicants in the tear film, because mucins could function as acceptors for charged moieties such as free radicals.
- 1 February 2003
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 44 (2) , 567-572
Patterns of Mucin Adherence to Contact Lenses
Purpose. Contact lens wear alters the preocular fluid through factors that include tear deposits on the lens. In the current study, lens-adherent material was extracted to assess whether contact lenses sample mucins from the preocular fluid. methods. Discarded extended-wear contact lenses were collected from patients with no ocular surface disease. Mucins were extracted in guanidine hydrochloride (GuHCl) with protease inhibitors. After the supernatant was removed, the extraction was repeated twice with the addition of 10 mM dithiothreitol, making a total of three extractions. Mucins were isolated by cesium chloride (CsCl) gradient centrifugation and size fractionated on Sepharose CL2B. Charge distribution was analyzed on ion-exchange chromatography with a lithium perchlorate (LiClO4) gradient. results. Contact lens–adherent mucins comprised soluble mucins and mucins that required solubilization by (repeated) dithiothreitol treatment. MUC1, MUC4, MUC2, and MUC5AC mucins eluted mainly at low buoyant densities in extractions from lenses worn long term without disinfection and at successively higher buoyant densities from monthly disposable contact lenses. Mucins with little negative charge, which were observed in all extractions, and very highly negatively charged species, present in the second and third extractions from contact lenses, had no equivalents in tissue-extracted mucins. conclusions. Mucins adhering to contact lenses are altered forms of intracellular mucins. Different degrees of adherence of mucins to contact lenses may occur, either because of mucin characteristics or after mucin complexation with adherent materials. In the context of good contact lens hygiene, their presence may offer some protection from toxicants in the tear film, because mucins could function as acceptors for charged moieties such as free radicals.