Pradeep Moonot
Research Subjects
Pradeep Moonot has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Neil Ashwood
Department of Trauma and Orthopaedics, University Hospitals of Derby and Burton NHS Foundation Trust, Burton-On-Trent DE13 0RB, UK
3 shared publications P. Allen
Princess Royal University Hospital Farnborough Kent UK
2 shared publications- Scott Arthur Banks
Department of Mechanical & Aerospace Engineering, University of Florida, Gainesville, FL, USA
2 shared publications Ah Harvey
Royal Bournemouth and Christchurch Hospitals NHS Foundation Trust, UK
1 shared publicationD. Lockwood
London School of Hygiene & Tropical Medicine, Keppel Street, London WC1E 7HT, UK
1 shared publicationFares S. Haddad
UCLH Trust
1 shared publication
Latest Publications
- 1 November 2013
- Published by Royal College of Surgeons of England in The Annals of The Royal College of Surgeons of England
- Vol. 95 (8) , 573-576
Impact of change of knee prosthesis on early clinical outcomes in a large volume arthroplasty centre
Introduction: The aim of our study was to investigate the effect of changing the default knee prosthesis in a high volume dedicated arthroplasty unit from DePuy’s PFC® Sigma® to Smith & Nephew’s Genesis™ II. Methods: A retrospective analysis was performed of prospective data on primary total knee replacements (TKRs) from January 2009 until December 2011. This provided information on the operative time, length of stay, pain at mobilisation, radiography analysis, any complications, and readmission at 30 and 60 days. Results: The total numbers of primary TKRs using the PFC® and Genesis™ II prostheses were 1,061 and 1,268 respectively. The results showed a slight increase (maximum of five minutes) in the operative time for all the surgeons except one surgeon, whose operative time reduced by an average of seven minutes. There was no significant adverse outcome after the change in the knee implant. There was no clinically significant increase in the length of stay, pain at mobilisation or complication rates. There was a twofold increase in the wastage of the implant in the Genesis™ II group in the initial learning period. Conclusions: Through a competitive process of implant tendering, we have successfully introduced a new implant into a large elective orthopaedic unit. This has resulted in significant financial savings without adversely affecting our clinical practice or patient outcome.
- 1 November 2013
- Published by Royal College of Surgeons of England in The Annals of The Royal College of Surgeons of England
- Vol. 95 (8) , 573-576
Impact of change of knee prosthesis on early clinical outcomes in a large volume arthroplasty centre
Introduction: The aim of our study was to investigate the effect of changing the default knee prosthesis in a high volume dedicated arthroplasty unit from DePuy’s PFC® Sigma® to Smith & Nephew’s Genesis™ II. Methods: A retrospective analysis was performed of prospective data on primary total knee replacements (TKRs) from January 2009 until December 2011. This provided information on the operative time, length of stay, pain at mobilisation, radiography analysis, any complications, and readmission at 30 and 60 days. Results: The total numbers of primary TKRs using the PFC® and Genesis™ II prostheses were 1,061 and 1,268 respectively. The results showed a slight increase (maximum of five minutes) in the operative time for all the surgeons except one surgeon, whose operative time reduced by an average of seven minutes. There was no significant adverse outcome after the change in the knee implant. There was no clinically significant increase in the length of stay, pain at mobilisation or complication rates. There was a twofold increase in the wastage of the implant in the Genesis™ II group in the initial learning period. Conclusions: Through a competitive process of implant tendering, we have successfully introduced a new implant into a large elective orthopaedic unit. This has resulted in significant financial savings without adversely affecting our clinical practice or patient outcome.
- 1 April 2009
- Published by SAGE Publications in Trauma
- Vol. 11 (2) , 123-132
Clavicle fractures
Clavicular fractures represent 2.6—5% of all fractures, with middle third fractures being the commonest. The shape of the clavicle bone is such that it has a flat medial and lateral expanses, linked by a thin, tubular middle. This central transitional area represents a weak link in clavicular structure, which is not protected by or reinforced with muscle or ligamentous attachments, therefore rendering it prone to fracture. Due to the subcutaneous position of the clavicle, there is an inherent susceptibility to direct injury. These fractures are easy to diagnose due to the presence of swelling and bruising present. Radiographical examination should include an anteroposterior and a 45°caudal tilt view. Optimal treatment in undisplaced or minimally displaced fractures is with a sling. In displaced or comminuted fractures the risk of non-union and poor functional outcome may be markedly higher and may be best treated with surgical fixation.
- 1 April 2009
- Published by SAGE Publications in Trauma
- Vol. 11 (2) , 123-132
Clavicle fractures
Clavicular fractures represent 2.6—5% of all fractures, with middle third fractures being the commonest. The shape of the clavicle bone is such that it has a flat medial and lateral expanses, linked by a thin, tubular middle. This central transitional area represents a weak link in clavicular structure, which is not protected by or reinforced with muscle or ligamentous attachments, therefore rendering it prone to fracture. Due to the subcutaneous position of the clavicle, there is an inherent susceptibility to direct injury. These fractures are easy to diagnose due to the presence of swelling and bruising present. Radiographical examination should include an anteroposterior and a 45°caudal tilt view. Optimal treatment in undisplaced or minimally displaced fractures is with a sling. In displaced or comminuted fractures the risk of non-union and poor functional outcome may be markedly higher and may be best treated with surgical fixation.
- 31 March 2009
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 17 (8) , 927-934
Tibiofemoral kinematic analysis of knee flexion for a medial pivot knee
The performance of total knee arthroplasty in deeply flexed postures is of increasing concern as the procedure is performed on younger, more physically active and more culturally diverse populations. Several implant design factors, including tibiofemoral conformity, tibial slope and posterior condylar geometry have been shown directly to affect deep flexion performance. The goal of this study was to evaluate the kinematics of a fixed‐bearing, asymmetric, medial rotation arthroplasty design in moderate and deep flexion. Thirteen study participants (15 knees) with a medial rotation knee arthroplasty were observed performing a weight‐bearing lunge activity to maximum comfortable flexion and kneeling on a padded bench from 90° to maximum comfortable flexion using lateral fluoroscopy. Subjects averaged 74 years of age and nine were female. At maximum weight‐bearing flexion, the knees exhibited 115° of implant flexion (102°–125°) and 7° (−3° to 12°) of tibial internal rotation. The medial and lateral condylar translated posteriorly by 2 and 5 mm, respectively. At maximum kneeling flexion, the knees exhibited 119° of implant flexion (101°–139°) and 5° (−2° to 14°) of tibial internal rotation. The lateral condyle translated posteriorly by 11 mm. The medial rotation knee exhibited motion patterns similar to those observed in the normal knee, but less tibial rotation. The medially conforming articulation beneficially controls femoral AP position in deep flexion, in patients who require such motion as part of their lifestyle.
- 31 March 2009
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 17 (8) , 927-934
Tibiofemoral kinematic analysis of knee flexion for a medial pivot knee
The performance of total knee arthroplasty in deeply flexed postures is of increasing concern as the procedure is performed on younger, more physically active and more culturally diverse populations. Several implant design factors, including tibiofemoral conformity, tibial slope and posterior condylar geometry have been shown directly to affect deep flexion performance. The goal of this study was to evaluate the kinematics of a fixed‐bearing, asymmetric, medial rotation arthroplasty design in moderate and deep flexion. Thirteen study participants (15 knees) with a medial rotation knee arthroplasty were observed performing a weight‐bearing lunge activity to maximum comfortable flexion and kneeling on a padded bench from 90° to maximum comfortable flexion using lateral fluoroscopy. Subjects averaged 74 years of age and nine were female. At maximum weight‐bearing flexion, the knees exhibited 115° of implant flexion (102°–125°) and 7° (−3° to 12°) of tibial internal rotation. The medial and lateral condylar translated posteriorly by 2 and 5 mm, respectively. At maximum kneeling flexion, the knees exhibited 119° of implant flexion (101°–139°) and 5° (−2° to 14°) of tibial internal rotation. The lateral condyle translated posteriorly by 11 mm. The medial rotation knee exhibited motion patterns similar to those observed in the normal knee, but less tibial rotation. The medially conforming articulation beneficially controls femoral AP position in deep flexion, in patients who require such motion as part of their lifestyle.
- 1 April 2008
- Published by Royal College of Surgeons of England in The Annals of The Royal College of Surgeons of England
- Vol. 90 (3) , 208-212
Fast-Track Aassessment Clinic: Selection of Patients for a One-Stop Hip Assessment Clinic
INTRODUCTION: The fast-track assessment clinic (FTAC) is a process to select patients who are very likely to require primary total hip replacement. Selected patients can then be seen in a one-off clinic reducing the number of hospital visits, cost to primary care trusts and delay between referral and treatment. PATIENTS AND METHODS: Fifty patients on the waiting list for hip replacement were analysed to see if there were common parameters that led to their inclusion. From these data, fast-track selection criteria (FTSCs) were generated. These FTSCs were used to make a dual comparison of outcomes between 52 patients seen in a traditional clinic. Finally, a pilot study was conducted in which patients fulfilling FTSCs were seen in a designated clinic. RESULTS: An Oxford hip score (OHS) of 34 and above combined with severe loss of joint space, severe marginal osteophytes, or both was common to most patients on the waiting list (84%). FTSCs correctly predicted the outcome of the orthopaedic clinic in 38 patients out of a total of 52. During the pilot stage, positive FTSCs were shown to have a positive predictive value of 92% for joint replacement being carried out and a negative predictive value of 46%. CONCLUSIONS: An OHS of 34 or above combined with complete loss of joint space and/or severe marginal osteophyte formation can be used to select patients who are very likely to need total hip replacement. These patients can be seen in a clinic that combines assessment of surgical indication with medical fitness for surgery.
- 1 April 2008
- Published by Royal College of Surgeons of England in The Annals of The Royal College of Surgeons of England
- Vol. 90 (3) , 208-212
Fast-Track Aassessment Clinic: Selection of Patients for a One-Stop Hip Assessment Clinic
INTRODUCTION: The fast-track assessment clinic (FTAC) is a process to select patients who are very likely to require primary total hip replacement. Selected patients can then be seen in a one-off clinic reducing the number of hospital visits, cost to primary care trusts and delay between referral and treatment. PATIENTS AND METHODS: Fifty patients on the waiting list for hip replacement were analysed to see if there were common parameters that led to their inclusion. From these data, fast-track selection criteria (FTSCs) were generated. These FTSCs were used to make a dual comparison of outcomes between 52 patients seen in a traditional clinic. Finally, a pilot study was conducted in which patients fulfilling FTSCs were seen in a designated clinic. RESULTS: An Oxford hip score (OHS) of 34 and above combined with severe loss of joint space, severe marginal osteophytes, or both was common to most patients on the waiting list (84%). FTSCs correctly predicted the outcome of the orthopaedic clinic in 38 patients out of a total of 52. During the pilot stage, positive FTSCs were shown to have a positive predictive value of 92% for joint replacement being carried out and a negative predictive value of 46%. CONCLUSIONS: An OHS of 34 or above combined with complete loss of joint space and/or severe marginal osteophyte formation can be used to select patients who are very likely to need total hip replacement. These patients can be seen in a clinic that combines assessment of surgical indication with medical fitness for surgery.
- 1 September 2007
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 89-B (9) , 1206-1209
Early results for treatment of three- and four-part fractures of the proximal humerus using the PHILOS plate system
Secure fixation of displaced proximal fractures of the humerus is a challenging problem. A total of 32 patients with acutely displaced three- or four-part proximal fractures of the humerus were treated by open reduction and internal fixation using the proximal humeral internal locking system (PHILOS) plate. There were 23 women and nine men with a mean age of 59.9 years (18 to 87). Data were collected prospectively and the outcomes were assessed using the Constant score. The mean follow-up was for 11 months (3 to 24). In 31 patients (97%) the fracture united clinically and radiologically at a mean of 10 weeks (8 to 24). The mean Constant score at final review was 66.5 (30 to 92). There was no significant difference in outcome when comparing patients aged more than 60 years (18 patients) with those aged less than 60 years (14 patients) (t-test, p = 0.8443). There was one case each of nonunion, malunion and a broken screw in the elderly population. This plate provides an alternative method of fixation for fractures of the proximal humerus. It provides a stable fixation in young patients with good-quality bone sufficient to permit early mobilisation. Failure of the screws to maintain fixation in the elderly remains a problem.
- 1 September 2007
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 89-B (9) , 1206-1209
Early results for treatment of three- and four-part fractures of the proximal humerus using the PHILOS plate system
Secure fixation of displaced proximal fractures of the humerus is a challenging problem. A total of 32 patients with acutely displaced three- or four-part proximal fractures of the humerus were treated by open reduction and internal fixation using the proximal humeral internal locking system (PHILOS) plate. There were 23 women and nine men with a mean age of 59.9 years (18 to 87). Data were collected prospectively and the outcomes were assessed using the Constant score. The mean follow-up was for 11 months (3 to 24). In 31 patients (97%) the fracture united clinically and radiologically at a mean of 10 weeks (8 to 24). The mean Constant score at final review was 66.5 (30 to 92). There was no significant difference in outcome when comparing patients aged more than 60 years (18 patients) with those aged less than 60 years (14 patients) (t-test, p = 0.8443). There was one case each of nonunion, malunion and a broken screw in the elderly population. This plate provides an alternative method of fixation for fractures of the proximal humerus. It provides a stable fixation in young patients with good-quality bone sufficient to permit early mobilisation. Failure of the screws to maintain fixation in the elderly remains a problem.
- 23 December 2005
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 14 (9) , 862-864
Intra‐articular pull out of an interference screw after anterior cruciate ligament reconstruction
We report a rare case of late femoral interference screw migration in the posterior compartment of the knee after anterior cruciate ligament reconstruction. The graft was intact with no signs of damage. The screw was successfully removed through the posteromedial portal site and the patient regained full function of the knee.
- 23 December 2005
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 14 (9) , 862-864
Intra‐articular pull out of an interference screw after anterior cruciate ligament reconstruction
We report a rare case of late femoral interference screw migration in the posterior compartment of the knee after anterior cruciate ligament reconstruction. The graft was intact with no signs of damage. The screw was successfully removed through the posteromedial portal site and the patient regained full function of the knee.
- 14 December 2005
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 14 (10) , 1004-1006
Intra‐articular pull out of an interference screw after anterior cruciate ligament reconstruction
We report a rare case of late femoral interference screw migration in the posterior compartment of the knee after anterior cruciate ligament reconstruction. The graft was intact with no signs of damage. The screw was successfully removed through the posteromedial portal site and the patient regained full function of the knee
- 14 December 2005
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 14 (10) , 1004-1006
Intra‐articular pull out of an interference screw after anterior cruciate ligament reconstruction
We report a rare case of late femoral interference screw migration in the posterior compartment of the knee after anterior cruciate ligament reconstruction. The graft was intact with no signs of damage. The screw was successfully removed through the posteromedial portal site and the patient regained full function of the knee
- Open Access
- 1 October 2005
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 87-B (10) , 1328-1332
Orthopaedic complications of leprosy
- 1 October 2005
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 87-B (10) , 1328-1332
Open AccessOrthopaedic complications of leprosy
- 1 June 2005
- Published by Springer Nature in European Journal of Trauma
- Vol. 31 (3) , 271-273
Simultaneous Ipsilateral Fracture of the Elbow, Forearm and Wrist in a Child
- 1 June 2005
- Published by Springer Nature in European Journal of Trauma
- Vol. 31 (3) , 271-273
Simultaneous Ipsilateral Fracture of the Elbow, Forearm and Wrist in a Child