Gul Tosun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Gul Tosun has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Yagmur Sener
5 shared publications- Abdulkadir Sengun
Department of Conservative Dentistry, Faculty of Dentistry, Selçuk University, Konya, Turkey
2 shared publications - Ebru Kucukyilmaz
Department of Pediatric Dentistry, Faculty of Dentistry, İzmir Kâtip Çelebi University, Izmir, Turkey
2 shared publications Y. Sener
2 shared publicationsA. U. Eldeniz
1 shared publicationAbdulkadir Ṣengün
Associate Professor, Selcuk University, Faculty of Dentistry, Department of Conservative Dentistry, Konya, Turkey
1 shared publication
Latest Publications
- 25 April 2015
- Vol. 82 (1) , 53-6
Periostitis ossificans managed with endodontic treatment.
Periostitis ossificans (PO) is a specific type of chronic osteomyelitis. Radiographically, it is characterized by the presence of lamellae of newly formed periosteal bone outside the cortex, giving the characteristic appearance of "onion skin." The most common cause of PO is periapical infection of the mandibular permanent first molar, which occurs primarily in children and young adults. Treatment in these cases is directed toward eliminating the source of the infection, either by extraction of the offending tooth or endodontic therapy. The purpose of this paper is to present a case of PO involving a permanent mandibular first molar managed with endodontic treatment.
- 25 April 2015
- Vol. 82 (1) , 53-6
Periostitis ossificans managed with endodontic treatment.
Periostitis ossificans (PO) is a specific type of chronic osteomyelitis. Radiographically, it is characterized by the presence of lamellae of newly formed periosteal bone outside the cortex, giving the characteristic appearance of "onion skin." The most common cause of PO is periapical infection of the mandibular permanent first molar, which occurs primarily in children and young adults. Treatment in these cases is directed toward eliminating the source of the infection, either by extraction of the offending tooth or endodontic therapy. The purpose of this paper is to present a case of PO involving a permanent mandibular first molar managed with endodontic treatment.
- 1 January 2014
- Published by International Organization of Scientific Research in IOSR Journal of Dental and Medical Sciences
- Vol. 13 (4) , 80-82
Dental Treatment in Asperger Syndrome
- 1 January 2014
- Published by International Organization of Scientific Research in IOSR Journal of Dental and Medical Sciences
- Vol. 13 (4) , 80-82
Dental Treatment in Asperger Syndrome
- 1 January 2013
- Published by Kare Publishing in Journal of Pediatric Dentistry
- Vol. 1 (2) , 42
Influence of soft drinks on dental enamel: An in vitro study
This in vitro study was to evaluate the erosive potential of four soft drinks at different times on bovine teeth by profilometry. Bovine incisors buccal side was sectioned with a diamond saw and a total of 100 enamel blocks were prepared (8 × 4 × 0.5 mm). Five specimens each were exposed to 60 ml of soft drinks (Sprite, Coca Cola, Cappy-orange and Ayran) for 15, 30, 60, 120 and 180 minutes in a continuously vibrating soft drinks bath in a beaker at room temperature. Surface loss of the specimens was determined with a profilometry. The data were analyzed by two-way analysis of variance and Tukey HSD test. Loss of enamel was observed in Coca Cola, Cappy and Sprite groups. Coca Cola was significantly higher erosive potential in 180 minutes than other soft drinks (p < 0.05). Ayran was no sign of erosive potential in all time. It can be concluded that the composition of the beverages had a significant effect on dental erosion, so consumption of Ayran can be advised.
- 1 January 2013
- Published by Kare Publishing in Journal of Pediatric Dentistry
- Vol. 1 (2) , 42
Influence of soft drinks on dental enamel: An in vitro study
This in vitro study was to evaluate the erosive potential of four soft drinks at different times on bovine teeth by profilometry. Bovine incisors buccal side was sectioned with a diamond saw and a total of 100 enamel blocks were prepared (8 × 4 × 0.5 mm). Five specimens each were exposed to 60 ml of soft drinks (Sprite, Coca Cola, Cappy-orange and Ayran) for 15, 30, 60, 120 and 180 minutes in a continuously vibrating soft drinks bath in a beaker at room temperature. Surface loss of the specimens was determined with a profilometry. The data were analyzed by two-way analysis of variance and Tukey HSD test. Loss of enamel was observed in Coca Cola, Cappy and Sprite groups. Coca Cola was significantly higher erosive potential in 180 minutes than other soft drinks (p < 0.05). Ayran was no sign of erosive potential in all time. It can be concluded that the composition of the beverages had a significant effect on dental erosion, so consumption of Ayran can be advised.
- 1 September 2009
- Published by MRE Press in Journal of Clinical Pediatric Dentistry
- Vol. 34 (1) , 71-75
Rapp-Hodgkin Syndrome: Clinical and Dental Findings
Rapp-Hodgkin syndrome is a rare form of ectodermal dysplasia involving the hair, eyes, sweat glands, nails,teeth and palate. This syndrome is characterized by stiff, sparse hair with the appearance of steel wool,sparse eyebrows and lashes, cleft palate, absence of lacrimal punctae, epiphora, a decreased number of sweat glands, and dystrophic nails. Cleft palate, hypodontia, abnormal tooth shape, multiple caries, delayed eruption of teeth are the main oral manifestations. In this paper we describe the clinical and dental findings of this syndrome in a 7 year old girl referred to the dental clinic because of severe tooth ache. The dental treatment included root canal treatment, composite restorations, extractions and removable prostheses. This paper highlights features of Rapp-Hodgkin Syndrome and its dental rehabilitation.
- 1 September 2009
- Published by MRE Press in Journal of Clinical Pediatric Dentistry
- Vol. 34 (1) , 71-75
Rapp-Hodgkin Syndrome: Clinical and Dental Findings
Rapp-Hodgkin syndrome is a rare form of ectodermal dysplasia involving the hair, eyes, sweat glands, nails,teeth and palate. This syndrome is characterized by stiff, sparse hair with the appearance of steel wool,sparse eyebrows and lashes, cleft palate, absence of lacrimal punctae, epiphora, a decreased number of sweat glands, and dystrophic nails. Cleft palate, hypodontia, abnormal tooth shape, multiple caries, delayed eruption of teeth are the main oral manifestations. In this paper we describe the clinical and dental findings of this syndrome in a 7 year old girl referred to the dental clinic because of severe tooth ache. The dental treatment included root canal treatment, composite restorations, extractions and removable prostheses. This paper highlights features of Rapp-Hodgkin Syndrome and its dental rehabilitation.
- 25 February 2008
- Published by Wiley in International Endodontic Journal
- Vol. 41 (5) , 436-441
Accuracy of two electronic apex locators in primary teeth with and without apical resorption: a laboratory study
To evaluate the accuracy of the Root ZX (J Morita Corp., Kyoto, Japan) and Tri Auto ZX (J Morita Corp.) devices for measuring root canal length in primary teeth with and without apical resorption. Thirty-four extracted human primary molar teeth with resorption and 19 primary teeth without resorption were collected. After endodontic access preparation, the actual lengths of the teeth were determined. The teeth were then embedded in an alginate model to determine the electronic working length measurement. Statistical evaluation was completed using Student's t-tests. For the Root ZX, there was no significant difference between those teeth with root resorption and those without. However, for the Tri Auto ZX, there was a significant difference in the electronic measurements between those teeth with root resorption and those without (P < 0.05). Significant differences were found amongst the measurements of the two apex locators (P < 0.05). For root canals with resorption, the respective accuracy rates (within +/-0.5 mm) of Root ZX and Tri Auto ZX were 83.33% and 89.47%; within +/-1 mm, the Root ZX and Tri Auto ZX demonstrated 98.95% and 100% accuracy, respectively. For root canals with no resorption, the percentage of measurements within +/-0.5 mm of the apical construction was 89.28% for the Root ZX and 80.35% for the Tri Auto ZX. The accuracy within +/-1 mm of the Root ZX and the Tri Auto ZX was 98.22% and 100%, respectively. Within the limitations of this laboratory study, the presence of resorption affected the performance of the Tri Auto ZX more than the Root ZX.
- 25 February 2008
- Published by Wiley in International Endodontic Journal
- Vol. 41 (5) , 436-441
Accuracy of two electronic apex locators in primary teeth with and without apical resorption: a laboratory study
To evaluate the accuracy of the Root ZX (J Morita Corp., Kyoto, Japan) and Tri Auto ZX (J Morita Corp.) devices for measuring root canal length in primary teeth with and without apical resorption. Thirty-four extracted human primary molar teeth with resorption and 19 primary teeth without resorption were collected. After endodontic access preparation, the actual lengths of the teeth were determined. The teeth were then embedded in an alginate model to determine the electronic working length measurement. Statistical evaluation was completed using Student's t-tests. For the Root ZX, there was no significant difference between those teeth with root resorption and those without. However, for the Tri Auto ZX, there was a significant difference in the electronic measurements between those teeth with root resorption and those without (P < 0.05). Significant differences were found amongst the measurements of the two apex locators (P < 0.05). For root canals with resorption, the respective accuracy rates (within +/-0.5 mm) of Root ZX and Tri Auto ZX were 83.33% and 89.47%; within +/-1 mm, the Root ZX and Tri Auto ZX demonstrated 98.95% and 100% accuracy, respectively. For root canals with no resorption, the percentage of measurements within +/-0.5 mm of the apical construction was 89.28% for the Root ZX and 80.35% for the Tri Auto ZX. The accuracy within +/-1 mm of the Root ZX and the Tri Auto ZX was 98.22% and 100%, respectively. Within the limitations of this laboratory study, the presence of resorption affected the performance of the Tri Auto ZX more than the Root ZX.
- Open Access
- 1 January 2008
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 27 (3) , 466-470
Temperature Rise under Normal and Caries-Affected Primary Tooth Dentin Disks during Polymerization of Adhesives and Resin-containing Dental Materials
The purpose of this study was to compare the temperature rise under normal and caries-affected primary tooth dentin during photopolymerization of two adhesives and resin-containing restorative materials. Caries-affected and normal dentin disks were prepared from extracted primary molars with only mesial or distal approximal caries (4 mm in diameter, 1 mm in height). Temperature rise during photopolymerization of adhesive materials was measured with a J-type thermocouple wire that was connected to a data logger. Data were analyzed with two-way ANOVA and independent samples t-test. Temperature rise under caries-affected primary tooth dentin disks was higher than that of normal primary tooth dentin disks during polymerization of both adhesive systems and resin-containing dental materials (p<0.05). It was found that adhesive systems induced a higher temperature rise during polymerization as compared to the resin-containing restorative materials (p<0.05). In particular, temperature rise during polymerization of adhesive materials exceeded 5.5°C under caries-affected primary tooth dentin.
- 1 January 2008
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 27 (3) , 466-470
Open AccessTemperature Rise under Normal and Caries-Affected Primary Tooth Dentin Disks during Polymerization of Adhesives and Resin-containing Dental Materials
The purpose of this study was to compare the temperature rise under normal and caries-affected primary tooth dentin during photopolymerization of two adhesives and resin-containing restorative materials. Caries-affected and normal dentin disks were prepared from extracted primary molars with only mesial or distal approximal caries (4 mm in diameter, 1 mm in height). Temperature rise during photopolymerization of adhesive materials was measured with a J-type thermocouple wire that was connected to a data logger. Data were analyzed with two-way ANOVA and independent samples t-test. Temperature rise under caries-affected primary tooth dentin disks was higher than that of normal primary tooth dentin disks during polymerization of both adhesive systems and resin-containing dental materials (p<0.05). It was found that adhesive systems induced a higher temperature rise during polymerization as compared to the resin-containing restorative materials (p<0.05). In particular, temperature rise during polymerization of adhesive materials exceeded 5.5°C under caries-affected primary tooth dentin.
- Open Access
- 1 January 2008
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 02 (01) , 11-17
Microtensile and Microshear Bond Strength of an Antibacterial Self-Etching System to Primary Tooth Dentin
Objectives: The aim of this study was to test the hypothesis that the bonding ability of antibacterial bonding system to primary dentin was not different from the parental material which did not contain any antibacterial component. Methods: Extracted human non-carious primary molars were ground to expose the coronal dentin, and then randomly divided into two experimental groups: treatment with Clearfil Protect Bond or with Clearfil SE Bond (Kuraray Medical Inc.). Composite-dentin sticks with a cross-sectional area of approximately 0.90 mm2 were prepared and subsequently subjected to microtensile bond strength (μTBS) and microshear bond strength (μSBS) tests. For the μTBS tests, specimens were attached to an Instron testing machine with a cyanoacrylate adhesive. For μSBS testing, the sticks were mechanically fixed to the μSBS testing apparatus. The bonds were stressed in shear or tension at a crosshead speed of 1mm/min until failure occurred. Resin-dentin interfaces produced by each system were examined using SEM. The data were analyzed with Mann-Whitney’s U test. Results: The μTBS and μSBS of Clearfil Protect Bond were 30.69±9.71 and 9.94±3.78 MPa, respectively. Clearfil SE Bond showed significantly greater values of 37.31±9.57 and 12.83±3.15 MPa, respectively. SEM analysis demonstrated similar micro-morphological features including the thickness of the hybrid layer for both materials. Conclusions: It was showed that antibacterial self-etching system Clearfil Protect Bond showed lower bond strength values compared to primary dentin than that of to Clearfil SE Bond on primary dentin. (Eur J Dent 2008;2:11-17)
- 1 January 2008
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 02 (01) , 11-17
Open AccessMicrotensile and Microshear Bond Strength of an Antibacterial Self-Etching System to Primary Tooth Dentin
Objectives: The aim of this study was to test the hypothesis that the bonding ability of antibacterial bonding system to primary dentin was not different from the parental material which did not contain any antibacterial component. Methods: Extracted human non-carious primary molars were ground to expose the coronal dentin, and then randomly divided into two experimental groups: treatment with Clearfil Protect Bond or with Clearfil SE Bond (Kuraray Medical Inc.). Composite-dentin sticks with a cross-sectional area of approximately 0.90 mm2 were prepared and subsequently subjected to microtensile bond strength (μTBS) and microshear bond strength (μSBS) tests. For the μTBS tests, specimens were attached to an Instron testing machine with a cyanoacrylate adhesive. For μSBS testing, the sticks were mechanically fixed to the μSBS testing apparatus. The bonds were stressed in shear or tension at a crosshead speed of 1mm/min until failure occurred. Resin-dentin interfaces produced by each system were examined using SEM. The data were analyzed with Mann-Whitney’s U test. Results: The μTBS and μSBS of Clearfil Protect Bond were 30.69±9.71 and 9.94±3.78 MPa, respectively. Clearfil SE Bond showed significantly greater values of 37.31±9.57 and 12.83±3.15 MPa, respectively. SEM analysis demonstrated similar micro-morphological features including the thickness of the hybrid layer for both materials. Conclusions: It was showed that antibacterial self-etching system Clearfil Protect Bond showed lower bond strength values compared to primary dentin than that of to Clearfil SE Bond on primary dentin. (Eur J Dent 2008;2:11-17)
- 21 August 2007
- Published by Wiley in International Journal of Paediatric Dentistry
- Vol. 18 (1) , 62-69
Bond strength of two total‐etching bonding systems on caries‐affected and sound primary teeth dentin
Aim. As bond strength of currently available adhesive systems in caries‐affected teeth dentin on primary tooth dentin was not well known, the bond strength of two bonding systems (PQI and OptiBond Solo Plus) was evaluated on caries‐affected and sound primary molar tooth dentin and observed the micromorphology of the adhesive–dentin interfaces.Methods. By grinding both the sound (n = 30) and caries‐affected (n = 30) approximal surfaces of teeth, flat dentin surfaces were obtained. The prepared surfaces were bonded with one of the each adhesive systems and a composite resin. After storing the bonded specimens in water at 37 °C for 24 h, the samples were sectioned and the bond strength of the adhesive systems was tested by the microshear test method. The data were statistically analysed.Results. Microshear bond strengths of PQI group for caries‐affected and sound primary tooth dentin were 9.43 ± 2.44 (MPa) and 9.32 ± 2.95 (MPa) (P > 0.05), respectively, and the bond strengths of OptiBond Solo Plus group for caries‐affected and sound primary tooth dentin were 15.33 ± 3.59 (MPa) and 11.96 ± 2.30 (MPa) (P < 0.05), respectively. Micromorphological features between sound and caries‐affected dentin were similar in both PQI and OptiBond Solo Plus groups.Conclusion. Both the adhesives showed significantly different bond strengths in caries‐affected dentin but showed similar bond strengths in sound dentin.
- 21 August 2007
- Published by Wiley in International Journal of Paediatric Dentistry
- Vol. 18 (1) , 62-69
Bond strength of two total‐etching bonding systems on caries‐affected and sound primary teeth dentin
Aim. As bond strength of currently available adhesive systems in caries‐affected teeth dentin on primary tooth dentin was not well known, the bond strength of two bonding systems (PQI and OptiBond Solo Plus) was evaluated on caries‐affected and sound primary molar tooth dentin and observed the micromorphology of the adhesive–dentin interfaces.Methods. By grinding both the sound (n = 30) and caries‐affected (n = 30) approximal surfaces of teeth, flat dentin surfaces were obtained. The prepared surfaces were bonded with one of the each adhesive systems and a composite resin. After storing the bonded specimens in water at 37 °C for 24 h, the samples were sectioned and the bond strength of the adhesive systems was tested by the microshear test method. The data were statistically analysed.Results. Microshear bond strengths of PQI group for caries‐affected and sound primary tooth dentin were 9.43 ± 2.44 (MPa) and 9.32 ± 2.95 (MPa) (P > 0.05), respectively, and the bond strengths of OptiBond Solo Plus group for caries‐affected and sound primary tooth dentin were 15.33 ± 3.59 (MPa) and 11.96 ± 2.30 (MPa) (P < 0.05), respectively. Micromorphological features between sound and caries‐affected dentin were similar in both PQI and OptiBond Solo Plus groups.Conclusion. Both the adhesives showed significantly different bond strengths in caries‐affected dentin but showed similar bond strengths in sound dentin.
- Open Access
- 1 January 2007
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 26 (1) , 116-121
Effect of Storage Duration/Solution on Microshear Bond Strength of Composite to Enamel
The aim of this study was to determine the effect of three storage solutions and two storage durations on microshear bond strength (μSBS) of a resin composite. Sixty non-carious human permanent molars were stored in three storage solutions (0.1% thymol, 10% formalin, and distilled water). Each tooth was separated mesio-distally into two parts. Specimens of the first part were stored for 24 hours, while specimens of the second part were stored for two months in the solutions. After each storage period, the enamel surface was covered with a composite resin in combination with an etch-rinse adhesive system. Specimens were then serially sectioned into sticks of 1 mm2 bond area and subjected to μSBS test. There were no statistically significant differences between the two storage periods for each solution (p>0.05). The thymol solution group showed lower μSBS values than those of distilled water for both storage periods (p0.05). In conclusion, the thymol solution caused the μSBS of the resin composite to decrease when compared to both formalin and distilled water after 24 hours and two months. However, the μSBS of the resin composite was not affected by storage duration.
- 1 January 2007
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 26 (1) , 116-121
Open AccessEffect of Storage Duration/Solution on Microshear Bond Strength of Composite to Enamel
The aim of this study was to determine the effect of three storage solutions and two storage durations on microshear bond strength (μSBS) of a resin composite. Sixty non-carious human permanent molars were stored in three storage solutions (0.1% thymol, 10% formalin, and distilled water). Each tooth was separated mesio-distally into two parts. Specimens of the first part were stored for 24 hours, while specimens of the second part were stored for two months in the solutions. After each storage period, the enamel surface was covered with a composite resin in combination with an etch-rinse adhesive system. Specimens were then serially sectioned into sticks of 1 mm2 bond area and subjected to μSBS test. There were no statistically significant differences between the two storage periods for each solution (p>0.05). The thymol solution group showed lower μSBS values than those of distilled water for both storage periods (p0.05). In conclusion, the thymol solution caused the μSBS of the resin composite to decrease when compared to both formalin and distilled water after 24 hours and two months. However, the μSBS of the resin composite was not affected by storage duration.
- 3 April 2006
- Published by Wiley in International Journal of Paediatric Dentistry
- Vol. 16 (3) , 218-221
Apert syndrome with glucose‐6‐phosphate dehydrogenase deficiency: a case report
Summary. Apert syndrome is characterized by midface hypoplasia, syndactyly of the hands and feet, proptosis of eyes, steep and flat frontal bones, and premature union of cranial sutures. Maxillary hypoplasia, deep palatal vault, anterior open bite, crowding of the dental arch, severely delayed tooth eruption, and dental malocclusion are the main oral manifestations of this syndrome.In this report, a case of Apert syndrome with glucose‐6‐phosphate dehydrogenase (G6PD) deficiency is presented. The patient, a 4‐year‐old male and the fourth child of healthy parents, was admitted to our department because of delayed tooth eruption. He had all the cardinal symptoms of the Apert syndrome.Clinical examination revealed that primary centrals, canines and first molars erupted; however, primary second molars and laterals had not erupted. The patient had no dental caries. Preventive treatments were applied, and subsequently, the patient was taken to long‐term follow up.
- 3 April 2006
- Published by Wiley in International Journal of Paediatric Dentistry
- Vol. 16 (3) , 218-221
Apert syndrome with glucose‐6‐phosphate dehydrogenase deficiency: a case report
Summary. Apert syndrome is characterized by midface hypoplasia, syndactyly of the hands and feet, proptosis of eyes, steep and flat frontal bones, and premature union of cranial sutures. Maxillary hypoplasia, deep palatal vault, anterior open bite, crowding of the dental arch, severely delayed tooth eruption, and dental malocclusion are the main oral manifestations of this syndrome.In this report, a case of Apert syndrome with glucose‐6‐phosphate dehydrogenase (G6PD) deficiency is presented. The patient, a 4‐year‐old male and the fourth child of healthy parents, was admitted to our department because of delayed tooth eruption. He had all the cardinal symptoms of the Apert syndrome.Clinical examination revealed that primary centrals, canines and first molars erupted; however, primary second molars and laterals had not erupted. The patient had no dental caries. Preventive treatments were applied, and subsequently, the patient was taken to long‐term follow up.