Hideshi Sekine
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hideshi Sekine has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Syuntaro Nomoto
Department of Fixed Prosthodontics, Tokyo Dental College, Tokyo, Japan
4 shared publications Tatsuo Taguchi
Division of Oral Implantology, Department of Clinical Oral Health Science, Tokyo Dental College
3 shared publicationsFumiyori Matsuzaki
Division of Oral Implantology, Department of Clinical Oral Health Science, Tokyo Dental College
2 shared publicationsIchiro Shimamura
Department of Prosthodontics, Tokyo Dental College, Japan
2 shared publicationsKatsunori Furuya
Division of Oral Implantology, Department of Clinical Oral Health Science, Tokyo Dental College
2 shared publicationsKiyoshi Mochizuki
Laboratory of Brain Research, Oral Health Science Center, Tokyo Dental College, 1-2-2, Masago, Mihama, Chiba 261-8502, Japan
2 shared publications
Latest Publications
- Open Access
- 18 September 2026
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
Optimizing post-space drying: insights from an in vitro study using standardized three-dimensional-printed models
Optimizing post-space drying: insights from an in vitro study using standardized three-dimensional-printed models
- 18 September 2026
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
Open AccessOptimizing post-space drying: insights from an in vitro study using standardized three-dimensional-printed models
Optimizing post-space drying: insights from an in vitro study using standardized three-dimensional-printed models
- Open Access
Sintering Distortion in Multi-Composition-Layered Zirconia Disks for Dental Prostheses: An Experimental Analysis
Zirconia is a high-strength ceramic and has increasing importance, particularly in the field of aesthetic dentistry for crown restorations. Multi-composition-layered-type (MCL) zirconia is attracting attention as a new material that integrates high light transmittance with mechanical strength. However, there are no reports on the deformation induced by sintering in MCL zirconia. Therefore, we aimed to investigate the sintering distortion of MCL zirconia. An experimental fixed dental prosthesis (FDP) was designed based on a 4-unit monolithic zirconia FDP. A MCL with no color gradation and an MCL with color gradation were selected. Particularly, three milling areas—the top end of the disk (area I) (n = 7), vertical center (area II) (n = 7), and bottom end of the disk (area III) (n = 7)—were investigated. Moreover, sintering distortions generated by experimental FDPs were measured. Sintering distortion was detected in all areas. The direction of distortion varied by area—positive in area I, negative in area II, and approximately zero in area III—with a significant difference between areas I and II (p = 0.001). The largest absolute distortion was observed in c-MCL-A (area I); the corresponding marginal gaps were ~89.4 μm (second molar) and ~56.9 μm (first premolar), both below the clinical threshold of 120 μm.
Open AccessSintering Distortion in Multi-Composition-Layered Zirconia Disks for Dental Prostheses: An Experimental Analysis
Zirconia is a high-strength ceramic and has increasing importance, particularly in the field of aesthetic dentistry for crown restorations. Multi-composition-layered-type (MCL) zirconia is attracting attention as a new material that integrates high light transmittance with mechanical strength. However, there are no reports on the deformation induced by sintering in MCL zirconia. Therefore, we aimed to investigate the sintering distortion of MCL zirconia. An experimental fixed dental prosthesis (FDP) was designed based on a 4-unit monolithic zirconia FDP. A MCL with no color gradation and an MCL with color gradation were selected. Particularly, three milling areas—the top end of the disk (area I) (n = 7), vertical center (area II) (n = 7), and bottom end of the disk (area III) (n = 7)—were investigated. Moreover, sintering distortions generated by experimental FDPs were measured. Sintering distortion was detected in all areas. The direction of distortion varied by area—positive in area I, negative in area II, and approximately zero in area III—with a significant difference between areas I and II (p = 0.001). The largest absolute distortion was observed in c-MCL-A (area I); the corresponding marginal gaps were ~89.4 μm (second molar) and ~56.9 μm (first premolar), both below the clinical threshold of 120 μm.
- Open Access
- 19 January 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 128, 105078
Sintering distortion of monolithic zirconia in 4-unit fixed partial denture: Effect of layered structure and vertical milling area
- 19 January 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 128, 105078
Open AccessSintering distortion of monolithic zirconia in 4-unit fixed partial denture: Effect of layered structure and vertical milling area
- Open Access
- 1 January 2021
- Published by Tokyo Dental College in The Bulletin of Tokyo Dental College
- Vol. 62 (2) , 2020-0038-125
Patient with Poor Esthetic Anterior Tooth Position Treated with Lithium Disilicate Mesial Cantilever Single-retainer Fixed Partial Denture: A Case Report
We report a case of fixed prosthetic treatment for poor esthetics due to the position of the maxillary left lateral incisor in a 43-year-old woman. Initial examination revealed no carious lesions, but the tooth axis of the maxillary right canine showed mesial inclination of approximately 15°. Orthodontic treatment was first proposed but was declined by the patient as they did not wish to undergo a prolonged period of therapy. Therefore, recovery by extraction of the maxillary right lateral incisor and prosthetic treatment was proposed as an alternative. The method to be used for application of a 3-unit fixed partial denture and implant treatment was explained to the patient. She refused to give consent to this plan as well, however, due to concerns regarding the need to cut a lot from a non-problematic tooth and the length of time such treatment would require. Therefore, the problem was finally treated by application of a cantilever single-retainer fixed partial denture while giving sufficient consideration to extraction and occlusal contact. Lithium disilicate was used for the material of the prothesis. At 1 year after completion of treatment, no problem was observed with either the prosthetic appliance or the abutment teeth.
- 1 January 2021
- Published by Tokyo Dental College in The Bulletin of Tokyo Dental College
- Vol. 62 (2) , 2020-0038-125
Open AccessPatient with Poor Esthetic Anterior Tooth Position Treated with Lithium Disilicate Mesial Cantilever Single-retainer Fixed Partial Denture: A Case Report
We report a case of fixed prosthetic treatment for poor esthetics due to the position of the maxillary left lateral incisor in a 43-year-old woman. Initial examination revealed no carious lesions, but the tooth axis of the maxillary right canine showed mesial inclination of approximately 15°. Orthodontic treatment was first proposed but was declined by the patient as they did not wish to undergo a prolonged period of therapy. Therefore, recovery by extraction of the maxillary right lateral incisor and prosthetic treatment was proposed as an alternative. The method to be used for application of a 3-unit fixed partial denture and implant treatment was explained to the patient. She refused to give consent to this plan as well, however, due to concerns regarding the need to cut a lot from a non-problematic tooth and the length of time such treatment would require. Therefore, the problem was finally treated by application of a cantilever single-retainer fixed partial denture while giving sufficient consideration to extraction and occlusal contact. Lithium disilicate was used for the material of the prothesis. At 1 year after completion of treatment, no problem was observed with either the prosthetic appliance or the abutment teeth.
- Open Access
- 1 January 2012
- Published by Tokyo Dental College in The Bulletin of Tokyo Dental College
- Vol. 53 (3) , 109-117
Dental Implant Treatment after Improvement of Oral Environment by Orthodontic Therapy
A 57-year-old man presented with mesial inclination of the lower right first molar caused by untreated loss of the second premolar. The occlusal relationship was restored by dental implant treatment following improvement of the intraoral environment by orthodontic therapy. At his initial visit, the interdental spacing in the molar-premolar region was inadequate, as the first molar had mesially inclined into the extraction space of the second premolar. The patient had also lost the second molar and complained of masticatory problems on the right side. It was considered necessary to restore the second molar and improve the occlusal relationship with the first molar to recover occlusal function on the right side. After orthodontic therapy to correct the position of the mesially inclined tooth, occlusal restoration was carried out by dental implant treatment. The patient's clinical condition has remained excellent at over 5 years 2 months post-surgically and the patient is satisfied with the treatment outcome. The combination of dental implant treatment and orthodontic therapy were effective in improving the intraoral environment in this patient, indicating the efficacy of interdisciplinary treatment planning and practice.
- 1 January 2012
- Published by Tokyo Dental College in The Bulletin of Tokyo Dental College
- Vol. 53 (3) , 109-117
Open AccessDental Implant Treatment after Improvement of Oral Environment by Orthodontic Therapy
A 57-year-old man presented with mesial inclination of the lower right first molar caused by untreated loss of the second premolar. The occlusal relationship was restored by dental implant treatment following improvement of the intraoral environment by orthodontic therapy. At his initial visit, the interdental spacing in the molar-premolar region was inadequate, as the first molar had mesially inclined into the extraction space of the second premolar. The patient had also lost the second molar and complained of masticatory problems on the right side. It was considered necessary to restore the second molar and improve the occlusal relationship with the first molar to recover occlusal function on the right side. After orthodontic therapy to correct the position of the mesially inclined tooth, occlusal restoration was carried out by dental implant treatment. The patient's clinical condition has remained excellent at over 5 years 2 months post-surgically and the patient is satisfied with the treatment outcome. The combination of dental implant treatment and orthodontic therapy were effective in improving the intraoral environment in this patient, indicating the efficacy of interdisciplinary treatment planning and practice.
- 1 January 2012
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 56 (1) , 47-52
Immediate implant placement in the maxillary central incisor region: A case report
- 1 January 2012
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 56 (1) , 47-52
Immediate implant placement in the maxillary central incisor region: A case report
- 15 December 2011
- Vol. 26 (6) , 1303-8
Intravenous sedation and hemodynamic changes during dental implant surgery.
The purpose of the present study was to determine whether intravenous sedation during dental implant surgery contributed to stabilization of hemodynamics. Two hundred fifty-five consecutive patients treated with dental implants were randomly assigned to receive either intravenous sedation with local anesthesia (sedation group, n = 123) or local anesthesia only (nonsedation group, n = 132). Midazolam and propofol were used synergistically as sedative agents. Systolic blood pressure, diastolic blood pressure, and pulse rate were measured every 2.5 minutes during dental implant surgery. On the basis of these data, the coefficient of variation, percentage of change, maximum values, and incidences of a larger increase were analyzed and expressed as cardiovascular changes. A comparison of percentages of change, maximum values, and incidences of a greater increase showed that systolic and/or diastolic blood pressure were significantly higher in the nonsedation group than in the sedation group. The combination of midazolam and propofol sedation prevented excessive increases in blood pressure. The circulatory suppression induced by the intravenous sedation regimen not only reduced mental stress arising from the state of sedation but also exerted a pharmacologic effect. The application of this intravenous sedation regimen stabilized hemodynamics and contributed to the safety of the patient in dental implant surgery. The application of intravenous sedation had a beneficial effect for hemodynamic changes during dental implant surgery.
- 15 December 2011
- Vol. 26 (6) , 1303-8
Intravenous sedation and hemodynamic changes during dental implant surgery.
The purpose of the present study was to determine whether intravenous sedation during dental implant surgery contributed to stabilization of hemodynamics. Two hundred fifty-five consecutive patients treated with dental implants were randomly assigned to receive either intravenous sedation with local anesthesia (sedation group, n = 123) or local anesthesia only (nonsedation group, n = 132). Midazolam and propofol were used synergistically as sedative agents. Systolic blood pressure, diastolic blood pressure, and pulse rate were measured every 2.5 minutes during dental implant surgery. On the basis of these data, the coefficient of variation, percentage of change, maximum values, and incidences of a larger increase were analyzed and expressed as cardiovascular changes. A comparison of percentages of change, maximum values, and incidences of a greater increase showed that systolic and/or diastolic blood pressure were significantly higher in the nonsedation group than in the sedation group. The combination of midazolam and propofol sedation prevented excessive increases in blood pressure. The circulatory suppression induced by the intravenous sedation regimen not only reduced mental stress arising from the state of sedation but also exerted a pharmacologic effect. The application of this intravenous sedation regimen stabilized hemodynamics and contributed to the safety of the patient in dental implant surgery. The application of intravenous sedation had a beneficial effect for hemodynamic changes during dental implant surgery.
- 2 August 2004
- Published by Elsevier in International Congress Series
- Vol. 1270, 333-336
The activities of the central nervous system concerned with the recognition of periodontal tactile sensation
- 2 August 2004
- Published by Elsevier in International Congress Series
- Vol. 1270, 333-336
The activities of the central nervous system concerned with the recognition of periodontal tactile sensation
- 2 August 2004
- Published by Elsevier in International Congress Series
- Vol. 1270, 333-336
The activities of the central nervous system concerned with the recognition of periodontal tactile sensationRecording of SEFs following periodontal tactile stimulation and identification of the ECD in the postcentral gyrus in humans
- 2 August 2004
- Published by Elsevier in International Congress Series
- Vol. 1270, 333-336
The activities of the central nervous system concerned with the recognition of periodontal tactile sensationRecording of SEFs following periodontal tactile stimulation and identification of the ECD in the postcentral gyrus in humans