Maria Ionica
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Maria Ionica has a total of 233 co-authors. Here are the top co-authors by number of shared publications:
- Giovanni Ambrosi
INFN Perugia, via A. Pascoli, I-06100 Perugia, Italy
6 shared publications - Mirco Caprai
INFN, Sezione di Perugia, via Pascoli s.n.c., 06123 Perugia, Italy
5 shared publications - Andrea Papi
INFN, Sezione di Perugia, via Pascoli s.n.c., 06123 Perugia, Italy
4 shared publications - Anna Grazia Monteduro
Omnics Research Group, Department of Mathematics and Physics “Ennio De Giorgi”, University of Salento, Institute of Nanotechnology CNR-Nanotec, INFN Sezione di Lecce, Via per Monteroni, 73100 Lecce, Italy
4 shared publications - Anna Paola Caricato
INFN Sezione di Lecce, via per Arnesano, 73100 Lecce
4 shared publications - Arianna Morozzi
Istituto Nazionale di Fisica Nucleare, Sezione di Perugia, via A. Pascoli, 06123, Perugia
4 shared publications
Latest Publications
- Open Access
Hydrogenated Amorphous Silicon Charge-Selective Contact Devices on a Polyimide Flexible Substrate for Dosimetry and Beam Flux Measurements
Hydrogenated amorphous silicon (a-Si:H) devices on flexible substrates are currently being studied for application in dosimetry and beam flux measurements. The necessity of in vivo dosimetry requires thin devices with maximal transparency and flexibility. For this reason, a thin (7 to 2.49 × 1010 p/(cm2 s).
Open AccessHydrogenated Amorphous Silicon Charge-Selective Contact Devices on a Polyimide Flexible Substrate for Dosimetry and Beam Flux Measurements
Hydrogenated amorphous silicon (a-Si:H) devices on flexible substrates are currently being studied for application in dosimetry and beam flux measurements. The necessity of in vivo dosimetry requires thin devices with maximal transparency and flexibility. For this reason, a thin (7 to 2.49 × 1010 p/(cm2 s).
- Open Access
- 25 September 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (19) , 1551
Mobility Gaps of Hydrogenated Amorphous Silicon Related to Hydrogen Concentration and Its Influence on Electrical Performance
This paper presents a comprehensive study of hydrogenated amorphous silicon (a-Si)-based detectors, utilizing electrical characterization, Raman spectroscopy, photoemission, and inverse photoemission techniques. The unique properties of a-Si have sparked interest in its application for radiation detection in both physics and medicine. Although amorphous silicon (a-Si) is inherently a highly defective material, hydrogenation significantly reduces defect density, enabling its use in radiation detector devices. Spectroscopic measurements provide insights into the intricate relationship between the structure and electronic properties of a-Si, enhancing our understanding of how specific configurations, such as the choice of substrate, can markedly influence detector performance. In this study, we compare the performance of a-Si detectors deposited on two different substrates: crystalline silicon (c-Si) and flexible Kapton. Our findings suggest that detectors deposited on Kapton exhibit reduced sensitivity, despite having comparable noise and leakage current levels to those on crystalline silicon. We hypothesize that this discrepancy may be attributed to the substrate material, differences in film morphology, and/or the alignment of energy levels. Further measurements are planned to substantiate these hypotheses.
- 25 September 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (19) , 1551
Open AccessMobility Gaps of Hydrogenated Amorphous Silicon Related to Hydrogen Concentration and Its Influence on Electrical Performance
This paper presents a comprehensive study of hydrogenated amorphous silicon (a-Si)-based detectors, utilizing electrical characterization, Raman spectroscopy, photoemission, and inverse photoemission techniques. The unique properties of a-Si have sparked interest in its application for radiation detection in both physics and medicine. Although amorphous silicon (a-Si) is inherently a highly defective material, hydrogenation significantly reduces defect density, enabling its use in radiation detector devices. Spectroscopic measurements provide insights into the intricate relationship between the structure and electronic properties of a-Si, enhancing our understanding of how specific configurations, such as the choice of substrate, can markedly influence detector performance. In this study, we compare the performance of a-Si detectors deposited on two different substrates: crystalline silicon (c-Si) and flexible Kapton. Our findings suggest that detectors deposited on Kapton exhibit reduced sensitivity, despite having comparable noise and leakage current levels to those on crystalline silicon. We hypothesize that this discrepancy may be attributed to the substrate material, differences in film morphology, and/or the alignment of energy levels. Further measurements are planned to substantiate these hypotheses.
- Open Access
- 24 November 2023
- Published by MDPI AG in Instruments
- Vol. 7 (4) , 46
Collection of Silicon Detectors Mechanical Properties from Static and Dynamic Characterization Test Campaigns
Physics research is constantly pursuing more efficient silicon detectors, often trying to develop complex and optimized geometries, thus leading to non-trivial engineering challenges. Although critical for this optimization, there are few silicon tile mechanical data available in the literature. In an attempt to partially fill this gap, the present work details various mechanical-related aspects of spaceborne silicon detectors. Specifically, this study concerns three experimental campaigns with different objectives: a mechanical characterization of the material constituting the detector (in terms of density, elastic, and failure properties), an analysis of the adhesive effect on the loads, and a wirebond vibrational endurance campaign performed on three different unpotted samples. By collecting and discussing the experimental results, this work aims to fulfill its purpose of providing insight into the mechanical problems associated with this specific application and procuring input data of paramount importance. For the study to be complete, the perspective taken is broader than mere silicon analysis and embraces all related aspects; i.e., the detector–structure adhesive interface and the structural integrity of wirebonds. In summary, this paper presents experimental data on the material properties of silicon detectors, the impact of the adhesive on the gluing stiffness, and unpotted wirebond vibrational endurance. At the same time, the discussion of the results furnishes an all-encompassing view of the design-associated criticalities in experiments where silicon detectors are employed.
- 24 November 2023
- Published by MDPI AG in Instruments
- Vol. 7 (4) , 46
Open AccessCollection of Silicon Detectors Mechanical Properties from Static and Dynamic Characterization Test Campaigns
Physics research is constantly pursuing more efficient silicon detectors, often trying to develop complex and optimized geometries, thus leading to non-trivial engineering challenges. Although critical for this optimization, there are few silicon tile mechanical data available in the literature. In an attempt to partially fill this gap, the present work details various mechanical-related aspects of spaceborne silicon detectors. Specifically, this study concerns three experimental campaigns with different objectives: a mechanical characterization of the material constituting the detector (in terms of density, elastic, and failure properties), an analysis of the adhesive effect on the loads, and a wirebond vibrational endurance campaign performed on three different unpotted samples. By collecting and discussing the experimental results, this work aims to fulfill its purpose of providing insight into the mechanical problems associated with this specific application and procuring input data of paramount importance. For the study to be complete, the perspective taken is broader than mere silicon analysis and embraces all related aspects; i.e., the detector–structure adhesive interface and the structural integrity of wirebonds. In summary, this paper presents experimental data on the material properties of silicon detectors, the impact of the adhesive on the gluing stiffness, and unpotted wirebond vibrational endurance. At the same time, the discussion of the results furnishes an all-encompassing view of the design-associated criticalities in experiments where silicon detectors are employed.
- Open Access
- 4 October 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (19) , 3466
High-Resolution Photoemission Study of Neutron-Induced Defects in Amorphous Hydrogenated Silicon Devices
In this paper, by means of high-resolution photoemission, soft X-ray absorption and atomic force microscopy, we investigate, for the first time, the mechanisms of damaging, induced by neutron source, and recovering (after annealing) of p-i-n detector devices based on hydrogenated amorphous silicon (a-Si:H). This investigation will be performed by mean of high-resolution photoemission, soft X-Ray absorption and atomic force microscopy. Due to dangling bonds, the amorphous silicon is a highly defective material. However, by hydrogenation it is possible to reduce the density of the defect by several orders of magnitude, using hydrogenation and this will allow its usage in radiation detector devices. The investigation of the damage induced by exposure to high energy irradiation and its microscopic origin is fundamental since the amount of defects determine the electronic properties of the a-Si:H. The comparison of the spectroscopic results on bare and irradiated samples shows an increased degree of disorder and a strong reduction of the Si-H bonds after irradiation. After annealing we observe a partial recovering of the Si-H bonds, reducing the disorder in the Si (possibly due to the lowering of the radiation-induced dangling bonds). Moreover, effects in the uppermost coating are also observed by spectroscopies.
- 4 October 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (19) , 3466
Open AccessHigh-Resolution Photoemission Study of Neutron-Induced Defects in Amorphous Hydrogenated Silicon Devices
In this paper, by means of high-resolution photoemission, soft X-ray absorption and atomic force microscopy, we investigate, for the first time, the mechanisms of damaging, induced by neutron source, and recovering (after annealing) of p-i-n detector devices based on hydrogenated amorphous silicon (a-Si:H). This investigation will be performed by mean of high-resolution photoemission, soft X-Ray absorption and atomic force microscopy. Due to dangling bonds, the amorphous silicon is a highly defective material. However, by hydrogenation it is possible to reduce the density of the defect by several orders of magnitude, using hydrogenation and this will allow its usage in radiation detector devices. The investigation of the damage induced by exposure to high energy irradiation and its microscopic origin is fundamental since the amount of defects determine the electronic properties of the a-Si:H. The comparison of the spectroscopic results on bare and irradiated samples shows an increased degree of disorder and a strong reduction of the Si-H bonds after irradiation. After annealing we observe a partial recovering of the Si-H bonds, reducing the disorder in the Si (possibly due to the lowering of the radiation-induced dangling bonds). Moreover, effects in the uppermost coating are also observed by spectroscopies.
- Open Access
- 26 September 2022
- Published by MDPI AG in Instruments
- Vol. 6 (4) , 52
Tracker-in-Calorimeter (TIC) Project: A Calorimetric New Solution for Space Experiments
A space-based detector dedicated to measurements of -rays and charged particles has to achieve a balance between different instrumental requirements. A good angular resolution is necessary for the -rays, whereas an excellent geometric factor is needed for the charged particles. The tracking reference technique of -ray physics is based on a pair-conversion telescope made of passive material (e.g., tungsten) coupled with sensitive layers (e.g., silicon microstrip). However, this kind of detector has a limited acceptance because of the large lever arm between the active layers, needed to improve the track reconstruction capability. Moreover, the passive material can induce fragmentation of nuclei, thus worsening charge reconstruction performances. The Tracker-In-Calorimeter (TIC) project aims to solve all these drawbacks. In the TIC proposal, the silicon sensors are moved inside a highly-segmented isotropic calorimeter with a couple of external scintillators dedicated to charge reconstruction. In principle, this configuration has a good geometrical factor, and the angle of the -rays can be precisely reconstructed from the lateral profile of the electromagnetic shower sampled, at different depths in the calorimeter, by silicon strips. The effectiveness of this approach has been studied with Monte Carlo simulations and validated with beam test data of a small prototype.- 26 September 2022
- Published by MDPI AG in Instruments
- Vol. 6 (4) , 52
Open AccessTracker-in-Calorimeter (TIC) Project: A Calorimetric New Solution for Space Experiments
A space-based detector dedicated to measurements of -rays and charged particles has to achieve a balance between different instrumental requirements. A good angular resolution is necessary for the -rays, whereas an excellent geometric factor is needed for the charged particles. The tracking reference technique of -ray physics is based on a pair-conversion telescope made of passive material (e.g., tungsten) coupled with sensitive layers (e.g., silicon microstrip). However, this kind of detector has a limited acceptance because of the large lever arm between the active layers, needed to improve the track reconstruction capability. Moreover, the passive material can induce fragmentation of nuclei, thus worsening charge reconstruction performances. The Tracker-In-Calorimeter (TIC) project aims to solve all these drawbacks. In the TIC proposal, the silicon sensors are moved inside a highly-segmented isotropic calorimeter with a couple of external scintillators dedicated to charge reconstruction. In principle, this configuration has a good geometrical factor, and the angle of the -rays can be precisely reconstructed from the lateral profile of the electromagnetic shower sampled, at different depths in the calorimeter, by silicon strips. The effectiveness of this approach has been studied with Monte Carlo simulations and validated with beam test data of a small prototype. - Open Access
- 11 May 2022
- Published by MDPI AG in Instruments
- Vol. 6 (2) , 19
Design of an Antimatter Large Acceptance Detector In Orbit (ALADInO)
A new generation magnetic spectrometer in space will open the opportunity to investigate the frontiers in direct high-energy cosmic ray measurements and to precisely measure the amount of the rare antimatter component in cosmic rays beyond the reach of current missions. We propose the concept for an Antimatter Large Acceptance Detector In Orbit (ALADInO), designed to take over the legacy of direct measurements of cosmic rays in space performed by PAMELA and AMS-02. ALADInO features technological solutions conceived to overcome the current limitations of magnetic spectrometers in space with a layout that provides an acceptance larger than 10 m sr. A superconducting magnet coupled to precision tracking and time-of-flight systems can provide the required matter–antimatter separation capabilities and rigidity measurement resolution with a Maximum Detectable Rigidity better than 20 TV. The inner 3D-imaging deep calorimeter, designed to maximize the isotropic acceptance of particles, allows for the measurement of cosmic rays up to PeV energies with accurate energy resolution to precisely measure features in the cosmic ray spectra. The operations of ALADInO in the Sun–Earth L2 Lagrangian point for at least 5 years would enable unique revolutionary observations with groundbreaking discovery potentials in the field of astroparticle physics by precision measurements of electrons, positrons, and antiprotons up to 10 TeV and of nuclear cosmic rays up to PeV energies, and by the possible unambiguous detection and measurement of low-energy antideuteron and antihelium components in cosmic rays.- 11 May 2022
- Published by MDPI AG in Instruments
- Vol. 6 (2) , 19
Open AccessDesign of an Antimatter Large Acceptance Detector In Orbit (ALADInO)
A new generation magnetic spectrometer in space will open the opportunity to investigate the frontiers in direct high-energy cosmic ray measurements and to precisely measure the amount of the rare antimatter component in cosmic rays beyond the reach of current missions. We propose the concept for an Antimatter Large Acceptance Detector In Orbit (ALADInO), designed to take over the legacy of direct measurements of cosmic rays in space performed by PAMELA and AMS-02. ALADInO features technological solutions conceived to overcome the current limitations of magnetic spectrometers in space with a layout that provides an acceptance larger than 10 m sr. A superconducting magnet coupled to precision tracking and time-of-flight systems can provide the required matter–antimatter separation capabilities and rigidity measurement resolution with a Maximum Detectable Rigidity better than 20 TV. The inner 3D-imaging deep calorimeter, designed to maximize the isotropic acceptance of particles, allows for the measurement of cosmic rays up to PeV energies with accurate energy resolution to precisely measure features in the cosmic ray spectra. The operations of ALADInO in the Sun–Earth L2 Lagrangian point for at least 5 years would enable unique revolutionary observations with groundbreaking discovery potentials in the field of astroparticle physics by precision measurements of electrons, positrons, and antiprotons up to 10 TeV and of nuclear cosmic rays up to PeV energies, and by the possible unambiguous detection and measurement of low-energy antideuteron and antihelium components in cosmic rays. - Open Access
- 8 October 2021
- Published by MDPI AG in Instruments
- Vol. 5 (4) , 32
Fabrication of a Hydrogenated Amorphous Silicon Detector in 3-D Geometry and Preliminary Test on Planar Prototypes
Hydrogenated amorphous silicon (a-Si:H) can be produced by plasma-enhanced chemical vapor deposition (PECVD) of SiH4 (silane) mixed with hydrogen. The resulting material shows outstanding radiation hardness properties and can be deposited on a wide variety of substrates. Devices employing a-Si:H technologies have been used to detect many different kinds of radiation, namely, minimum ionizing particles (MIPs), X-rays, neutrons, and ions, as well as low-energy protons and alphas. However, the detection of MIPs using planar a-Si:H diodes has proven difficult due to their unsatisfactory S/N ratio arising from a combination of high leakage current, high capacitance, and limited charge collection efficiency (50% at best for a 30 µm planar diode). To overcome these limitations, the 3D-SiAm collaboration proposes employing a 3D detector geometry. The use of vertical electrodes allows for a small collection distance to be maintained while preserving a large detector thickness for charge generation. The depletion voltage in this configuration can be kept below 400 V with a consequent reduction in the leakage current. In this paper, following a detailed description of the fabrication process, the results of the tests performed on the planar p-i-n structures made with ion implantation of the dopants and with carrier selective contacts are illustrated.
- 8 October 2021
- Published by MDPI AG in Instruments
- Vol. 5 (4) , 32
Open AccessFabrication of a Hydrogenated Amorphous Silicon Detector in 3-D Geometry and Preliminary Test on Planar Prototypes
Hydrogenated amorphous silicon (a-Si:H) can be produced by plasma-enhanced chemical vapor deposition (PECVD) of SiH4 (silane) mixed with hydrogen. The resulting material shows outstanding radiation hardness properties and can be deposited on a wide variety of substrates. Devices employing a-Si:H technologies have been used to detect many different kinds of radiation, namely, minimum ionizing particles (MIPs), X-rays, neutrons, and ions, as well as low-energy protons and alphas. However, the detection of MIPs using planar a-Si:H diodes has proven difficult due to their unsatisfactory S/N ratio arising from a combination of high leakage current, high capacitance, and limited charge collection efficiency (50% at best for a 30 µm planar diode). To overcome these limitations, the 3D-SiAm collaboration proposes employing a 3D detector geometry. The use of vertical electrodes allows for a small collection distance to be maintained while preserving a large detector thickness for charge generation. The depletion voltage in this configuration can be kept below 400 V with a consequent reduction in the leakage current. In this paper, following a detailed description of the fabrication process, the results of the tests performed on the planar p-i-n structures made with ion implantation of the dopants and with carrier selective contacts are illustrated.
- Open Access
- 31 May 2021
- Published by MDPI AG in Instruments
- Vol. 5 (2) , 20
Advantages and Requirements in Time Resolving Tracking for Astroparticle Experiments in Space
A large-area, solid-state detector with single-hit precision timing measurement will enable several breakthrough experimental advances for the direct measurement of particles in space. Silicon microstrip detectors are the most promising candidate technology to instrument the large areas of the next-generation astroparticle space borne detectors that could meet the limitations on power consumption required by operations in space. We overview the novel experimental opportunities that could be enabled by the introduction of the timing measurement, concurrent with the accurate spatial and charge measurement, in Silicon microstrip tracking detectors, and we discuss the technological solutions and their readiness to enable the operations of large-area Silicon microstrip timing detectors in space.
- 31 May 2021
- Published by MDPI AG in Instruments
- Vol. 5 (2) , 20
Open AccessAdvantages and Requirements in Time Resolving Tracking for Astroparticle Experiments in Space
A large-area, solid-state detector with single-hit precision timing measurement will enable several breakthrough experimental advances for the direct measurement of particles in space. Silicon microstrip detectors are the most promising candidate technology to instrument the large areas of the next-generation astroparticle space borne detectors that could meet the limitations on power consumption required by operations in space. We overview the novel experimental opportunities that could be enabled by the introduction of the timing measurement, concurrent with the accurate spatial and charge measurement, in Silicon microstrip tracking detectors, and we discuss the technological solutions and their readiness to enable the operations of large-area Silicon microstrip timing detectors in space.
- Open Access
A New Approach to Calorimetry in Space-Based Experiments for High-Energy Cosmic Rays
Precise measurements of the energy spectra and of the composition of cosmic rays in the PeV region could improve our knowledge regarding their origin, acceleration mechanism, propagation, and composition. At the present time, spectral measurements in this region are mainly derived from data collected by ground-based detectors, because of the very low particle rates at these energies. Unfortunately, these results are affected by the high uncertainties typical of indirect measurements, which depend on the complicated modeling of the interaction of the primary particle with the atmosphere. A space experiment dedicated to measurements in this energy region has to achieve a balance between the requirements of lightness and compactness, with that of a large acceptance to cope with the low particle rates. CaloCube is a four-year-old R&D project, approved and financed by the Istituto Nazionale di Fisica Nucleare (INFN) in 2014, aiming to optimize the design of a space-borne calorimeter. The large acceptance needed is obtained by maximizing the number of entrance windows, while thanks to its homogeneity and high segmentation this new detector achieves an excellent energy resolution and an enhanced separation power between hadrons and electrons. In order to optimize detector performances with respect to the total mass of the apparatus, comparative studies on different scintillating materials, different sizes of crystals, and different spacings among them have been performed making use of MonteCarlo simulations. In parallel to simulations studies, several prototypes instrumented with CsI(Tl) (Caesium Iodide, Tallium doped) cubic crystals have been constructed and tested with particle beams. Moreover, the last development of CaloCube, the Tracker-In-Calorimeter (TIC) project, financed by the INFN in 2018, is focused on the feasibility of including several silicon layers at different depths in the calorimeter in order to reconstruct the particle direction. In fact, an important requirement for -ray astronomy is to have a good angular resolution in order to allow precise identification of astrophysical sources in space. In respect to the traditional approach of using a tracker with passive material in front of the calorimeter, the TIC solution can save a significant amount of mass budget in a space satellite experiment, which can then be exploited to improve the acceptance and the resolution of the calorimeter. In this paper, the status of the project and perspectives for future developments are presented.Open AccessA New Approach to Calorimetry in Space-Based Experiments for High-Energy Cosmic Rays
Precise measurements of the energy spectra and of the composition of cosmic rays in the PeV region could improve our knowledge regarding their origin, acceleration mechanism, propagation, and composition. At the present time, spectral measurements in this region are mainly derived from data collected by ground-based detectors, because of the very low particle rates at these energies. Unfortunately, these results are affected by the high uncertainties typical of indirect measurements, which depend on the complicated modeling of the interaction of the primary particle with the atmosphere. A space experiment dedicated to measurements in this energy region has to achieve a balance between the requirements of lightness and compactness, with that of a large acceptance to cope with the low particle rates. CaloCube is a four-year-old R&D project, approved and financed by the Istituto Nazionale di Fisica Nucleare (INFN) in 2014, aiming to optimize the design of a space-borne calorimeter. The large acceptance needed is obtained by maximizing the number of entrance windows, while thanks to its homogeneity and high segmentation this new detector achieves an excellent energy resolution and an enhanced separation power between hadrons and electrons. In order to optimize detector performances with respect to the total mass of the apparatus, comparative studies on different scintillating materials, different sizes of crystals, and different spacings among them have been performed making use of MonteCarlo simulations. In parallel to simulations studies, several prototypes instrumented with CsI(Tl) (Caesium Iodide, Tallium doped) cubic crystals have been constructed and tested with particle beams. Moreover, the last development of CaloCube, the Tracker-In-Calorimeter (TIC) project, financed by the INFN in 2018, is focused on the feasibility of including several silicon layers at different depths in the calorimeter in order to reconstruct the particle direction. In fact, an important requirement for -ray astronomy is to have a good angular resolution in order to allow precise identification of astrophysical sources in space. In respect to the traditional approach of using a tracker with passive material in front of the calorimeter, the TIC solution can save a significant amount of mass budget in a space satellite experiment, which can then be exploited to improve the acceptance and the resolution of the calorimeter. In this paper, the status of the project and perspectives for future developments are presented.