Bernhard Christian Meyer
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bernhard Christian Meyer has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
K.-J. Wolf
Charité-University Medicine
5 shared publicationsW. Hopfenmüller
Charité-University Medicine
4 shared publicationsB. B. Frericks
Charité-University Hospital, Campus Benjamin Franklin
2 shared publicationsC. Ribbe
Charité-University Medicine
2 shared publications- F. K. Wacker
Johns Hopkins University, Baltimore, MD
2 shared publications F. Wacker
2 shared publications
Latest Publications
- 1 February 2015
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 26 (2) , S120
Comparison of C-arm computed tomography and multi-detector CT in patients with chronic thromboembolic pulmonary hypertension
- 1 February 2015
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 26 (2) , S120
Comparison of C-arm computed tomography and multi-detector CT in patients with chronic thromboembolic pulmonary hypertension
- 1 March 2014
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 25 (3) , S51
C-arm CT of the pulmonary arteries: does it provide additional information for the diagnostic work-up of patients with chronic thromboembolic pulmonary hypertension prior to surgical or interventional treatment?
- 1 March 2014
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 25 (3) , S51
C-arm CT of the pulmonary arteries: does it provide additional information for the diagnostic work-up of patients with chronic thromboembolic pulmonary hypertension prior to surgical or interventional treatment?
- 30 September 2009
- Published by Springer Nature in European Radiology
- Vol. 20 (2) , 497-505
Do the cardiovascular risk profile and the degree of arterial wall calcification influence the performance of MDCT angiography of lower extremity arteries?
To retrospectively assess the influence of arterial wall calcifications on the accuracy of run-off computed tomographic angiography (CTA) and to analyse whether cardiovascular risk factors are predictors of compromising calcifications.
- 30 September 2009
- Published by Springer Nature in European Radiology
- Vol. 20 (2) , 497-505
Do the cardiovascular risk profile and the degree of arterial wall calcification influence the performance of MDCT angiography of lower extremity arteries?
To retrospectively assess the influence of arterial wall calcifications on the accuracy of run-off computed tomographic angiography (CTA) and to analyse whether cardiovascular risk factors are predictors of compromising calcifications.
- 4 September 2009
- Published by Springer Nature in Der Radiologe
- Vol. 49 (9) , 856-861
Auf Flachdetektor-CT basierende elektromagnetische Navigation
- 4 September 2009
- Published by Springer Nature in Der Radiologe
- Vol. 49 (9) , 856-861
Auf Flachdetektor-CT basierende elektromagnetische Navigation
- 8 May 2009
- Published by Springer Nature in European Radiology
- Vol. 19 (9) , 2302-2309
The value of combined soft-tissue and vessel visualisation before transarterial chemoembolisation of the liver using C-arm computed tomography
The purpose of the study was to prospectively evaluate intrahepatic vessel depiction on C-arm CT (CACT) and the influence of the additional combined tissue and three-dimensional vessel visualisation on the positioning of the TACE catheter in comparison to DSA alone. Thirty consecutive patients scheduled for their first transarterial chemoembolisation underwent biphasic CACT and DSA of the liver. After assessing the DSA images for procedure planning, the CACT images were reviewed. The number and origin of the tumour-feeding arteries and the ideal position of the catheter for TACE on both DSA and CACT were assessed and correlated. The number of vessels identified as tumour feeders in each patient was significantly higher using additional CACT than on DSA alone (CACT: 4.0 ± 1.7; DSA: 3.3 ± 1.4; P = 0.003, t-test). After considering CACT, in 50% of the patients the catheter position was changed for TACE. Segmental portal vein thrombosis was seen in three patients on CACT, but in only one on DSA. As CACT depicts soft tissue and small vessels with high spatial resolution, tumour vessel allocation is facilitated, and ideal catheter position for TACE can be more accurately identified. The high impact of CACT on the TACE procedure suggests the benefits of its routine use for all patients undergoing their first TACE.
- 8 May 2009
- Published by Springer Nature in European Radiology
- Vol. 19 (9) , 2302-2309
The value of combined soft-tissue and vessel visualisation before transarterial chemoembolisation of the liver using C-arm computed tomography
The purpose of the study was to prospectively evaluate intrahepatic vessel depiction on C-arm CT (CACT) and the influence of the additional combined tissue and three-dimensional vessel visualisation on the positioning of the TACE catheter in comparison to DSA alone. Thirty consecutive patients scheduled for their first transarterial chemoembolisation underwent biphasic CACT and DSA of the liver. After assessing the DSA images for procedure planning, the CACT images were reviewed. The number and origin of the tumour-feeding arteries and the ideal position of the catheter for TACE on both DSA and CACT were assessed and correlated. The number of vessels identified as tumour feeders in each patient was significantly higher using additional CACT than on DSA alone (CACT: 4.0 ± 1.7; DSA: 3.3 ± 1.4; P = 0.003, t-test). After considering CACT, in 50% of the patients the catheter position was changed for TACE. Segmental portal vein thrombosis was seen in three patients on CACT, but in only one on DSA. As CACT depicts soft tissue and small vessels with high spatial resolution, tumour vessel allocation is facilitated, and ideal catheter position for TACE can be more accurately identified. The high impact of CACT on the TACE procedure suggests the benefits of its routine use for all patients undergoing their first TACE.
- 28 February 2009
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 20 (2) , S71-71
Abstract No. 184: Transarterial Chemoembolization (TACE) of Liver Metastases from Uveal Melanoma: Evaluation of Efficacy and LDH as a Prognostic Factor
- 28 February 2009
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 20 (2) , S71-71
Abstract No. 184: Transarterial Chemoembolization (TACE) of Liver Metastases from Uveal Melanoma: Evaluation of Efficacy and LDH as a Prognostic Factor
- 28 February 2009
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 20 (2) , S43-S44
Abstract No. 110: Fluoroscopy Guided Punctures in a Flat Detector C-Arm System: Evaluation of Stereoscopic Needle Tracking Based on Cone Beam CT Images
- 28 February 2009
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 20 (2) , S43-S44
Abstract No. 110: Fluoroscopy Guided Punctures in a Flat Detector C-Arm System: Evaluation of Stereoscopic Needle Tracking Based on Cone Beam CT Images
- 1 December 2008
- Published by Elsevier in European Journal of Radiology
- Vol. 68 (3) , 414-422
Dual energy CT of peripheral arteries: Effect of automatic bone and plaque removal on image quality and grading of stenoses
- 1 December 2008
- Published by Elsevier in European Journal of Radiology
- Vol. 68 (3) , 414-422
Dual energy CT of peripheral arteries: Effect of automatic bone and plaque removal on image quality and grading of stenoses
- 1 April 2008
- Published by Springer Nature in European Radiology
- Vol. 18 (8) , 1546-1555
Quantitative and qualitative evaluation of the influence of different table feeds on visualization of peripheral arteries in CT angiography of aortoiliac and lower extremity arteries
The influence of different table feeds (TF) on vascular enhancement and image quality in patients undergoing lower extremity runoff-CTA for peripheral artery occlusive disease (PAOD), acute ischemia (AI) or abdominal aortic aneurysm (AAA) with PAOD was investigated retrospectively. One hundred eighty-five patients (PAOD: n = 132; AI: n = 40; AAA: n = 13) underwent 16-detector runoff-CTA (120 kV; 140 mAs; rotation time 0.5 s, collimation 16 x 1.5 mm) using different TF (30 mm/s: n = 25; 40 mm/s: n = 91; 48 mm/s: n = 36; 56 mm/s: n = 33). Vascular enhancement of the large arteries was measured every 10cm along the z-axis from the upper abdomen to the toe. Arterial enhancement in the distal lower leg was compared (ANOVA, Bonferroni post-test). Qualitative assessment of bolus timing was performed independently by two radiologists. The study was IRB approved. In patients with PAOD or AI, enhancement of calf arteries using a TF of 48 mm/s (278 ± 79 HU) was significantly higher in comparison to two slower TF (30 mm/s: 201 ± 70 HU, P < 0.001; 40 mm/s: 251 ± 79 HU, P < 0.05; 56 mm/s: 261 ± 57 HU, NS) and the fewest noninterpretable arterial segments below the knee were observed with a TF of 48 mm/s (reader 1: 5/121 = 4.1%; reader 2: 4/121 = 3.3%). In patients with AAA, the fewest nondiagnostic segments occurred with a TF of 30 mm/s (2/12 = 17%, both readers) and 40 mm/s (4/24 = 17%, both readers). A TF of 48 mm/s provided the best synchronization of CT data acquisition and contrast bolus propagation and thus the best image quality in patients with PAOD and AI. In patients with AAA, a slower TF of 30 mm/s provided better image quality than faster CT protocols.
- 1 April 2008
- Published by Springer Nature in European Radiology
- Vol. 18 (8) , 1546-1555
Quantitative and qualitative evaluation of the influence of different table feeds on visualization of peripheral arteries in CT angiography of aortoiliac and lower extremity arteries
The influence of different table feeds (TF) on vascular enhancement and image quality in patients undergoing lower extremity runoff-CTA for peripheral artery occlusive disease (PAOD), acute ischemia (AI) or abdominal aortic aneurysm (AAA) with PAOD was investigated retrospectively. One hundred eighty-five patients (PAOD: n = 132; AI: n = 40; AAA: n = 13) underwent 16-detector runoff-CTA (120 kV; 140 mAs; rotation time 0.5 s, collimation 16 x 1.5 mm) using different TF (30 mm/s: n = 25; 40 mm/s: n = 91; 48 mm/s: n = 36; 56 mm/s: n = 33). Vascular enhancement of the large arteries was measured every 10cm along the z-axis from the upper abdomen to the toe. Arterial enhancement in the distal lower leg was compared (ANOVA, Bonferroni post-test). Qualitative assessment of bolus timing was performed independently by two radiologists. The study was IRB approved. In patients with PAOD or AI, enhancement of calf arteries using a TF of 48 mm/s (278 ± 79 HU) was significantly higher in comparison to two slower TF (30 mm/s: 201 ± 70 HU, P < 0.001; 40 mm/s: 251 ± 79 HU, P < 0.05; 56 mm/s: 261 ± 57 HU, NS) and the fewest noninterpretable arterial segments below the knee were observed with a TF of 48 mm/s (reader 1: 5/121 = 4.1%; reader 2: 4/121 = 3.3%). In patients with AAA, the fewest nondiagnostic segments occurred with a TF of 30 mm/s (2/12 = 17%, both readers) and 40 mm/s (4/24 = 17%, both readers). A TF of 48 mm/s provided the best synchronization of CT data acquisition and contrast bolus propagation and thus the best image quality in patients with PAOD and AI. In patients with AAA, a slower TF of 30 mm/s provided better image quality than faster CT protocols.