Gerd Geerling
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Gerd Geerling has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
M. Müller
6 shared publications- Stefan Schrader
Augenklinik, Universitätsklinikum Düsseldorf
5 shared publications A. Kramer
3 shared publicationsH. Ohgke
3 shared publicationsH. Strobel
3 shared publications- Thilo Wedel
Institute of Anatomy, Center of Clinical Anatomy, Kiel University, Kiel, Germany
3 shared publications
Latest Publications
- 30 January 2017
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 234 (01) , 40-45
Periokuläre nekrotisierende Fasziitis – Fallbericht und Überblick
Die periokuläre nekrotisierende Fasziitis ist ein sehr seltenes ophthalmologisches Krankheitsbild mit potenziell lebensbedrohenden Verlauf. Grundlage der Erkrankung ist eine bakterielle Infektion im Bereich der Faszien, die sich rasch ausbreitet. Dieser Beitrag legt beispielhaft den Verlauf der Erkrankung anhand eines Fallberichts dar und gibt einen Überblick über die typischen klinischen Zeichen und Symptome der periokulären nekrotisierenden Fasziitis. Peri-ocular necrotising fasciitis is a very rare ophthalmological clinical picture and is potentially fatal. This disease is caused by bacterial infection of the fasciae, which rapidly spreads. The present article reports a typical case of the disease and gives an overview of the typical clinical signs and symptoms of peri-ocular necrotising fasciitis.
- 30 January 2017
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 234 (01) , 40-45
Periokuläre nekrotisierende Fasziitis – Fallbericht und Überblick
Die periokuläre nekrotisierende Fasziitis ist ein sehr seltenes ophthalmologisches Krankheitsbild mit potenziell lebensbedrohenden Verlauf. Grundlage der Erkrankung ist eine bakterielle Infektion im Bereich der Faszien, die sich rasch ausbreitet. Dieser Beitrag legt beispielhaft den Verlauf der Erkrankung anhand eines Fallberichts dar und gibt einen Überblick über die typischen klinischen Zeichen und Symptome der periokulären nekrotisierenden Fasziitis. Peri-ocular necrotising fasciitis is a very rare ophthalmological clinical picture and is potentially fatal. This disease is caused by bacterial infection of the fasciae, which rapidly spreads. The present article reports a typical case of the disease and gives an overview of the typical clinical signs and symptoms of peri-ocular necrotising fasciitis.
- 13 November 2014
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 232 (01) , 85-98
Hornhaut: endotheliale Dystrophien, endotheliale Degenerationen
Dieser Übersichtsartikel bietet einen kurzen Überblick über die endothelialen Hornhautdystrophien (HD) und Degenerationen, deren primäre Störung im Bereich des einschichtigen Endothels bzw. der Descemet-Membran liegt, sowie deren Therapie. Hornhautendotheldegenerationen sind definiert als Veränderungen des Endothels aufgrund von Alterungsprozessen oder durch Trauma (z. B. nach Kataraktchirurgie). Hornhautdystrophien beschreiben eine Vielzahl verschiedener erblicher Krankheitsbilder, bei denen meist ein bilateraler, nahezu ausschließlicher Befall der Hornhaut vorliegt. Die Vererbung ist meist autosomal-dominant, kann aber auch autosomal-rezessiv und X-chromosomal-dominant sein.
- 13 November 2014
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 232 (01) , 85-98
Hornhaut: endotheliale Dystrophien, endotheliale Degenerationen
Dieser Übersichtsartikel bietet einen kurzen Überblick über die endothelialen Hornhautdystrophien (HD) und Degenerationen, deren primäre Störung im Bereich des einschichtigen Endothels bzw. der Descemet-Membran liegt, sowie deren Therapie. Hornhautendotheldegenerationen sind definiert als Veränderungen des Endothels aufgrund von Alterungsprozessen oder durch Trauma (z. B. nach Kataraktchirurgie). Hornhautdystrophien beschreiben eine Vielzahl verschiedener erblicher Krankheitsbilder, bei denen meist ein bilateraler, nahezu ausschließlicher Befall der Hornhaut vorliegt. Die Vererbung ist meist autosomal-dominant, kann aber auch autosomal-rezessiv und X-chromosomal-dominant sein.
- 20 August 2014
- Published by Wiley in Acta Ophthalmologica
- Vol. 92
Restoration of meibomian gland function in severe dry eye disease due to obstructive MGD with an automated physical therapy device
- 20 August 2014
- Published by Wiley in Acta Ophthalmologica
- Vol. 92
Restoration of meibomian gland function in severe dry eye disease due to obstructive MGD with an automated physical therapy device
- 18 June 2014
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 231 (06) , 603-610
Einflussfaktoren auf die Messung der Lipidschichtdicke des Tränenfilms mittels Interferometrie
Einleitung: Die quantitative Messung der Dicke der Lipidschicht des Tränenfilms ist eine neue und vielversprechende Methode zur Diagnostik von qualitativem Tränenmangel. Allerdings gibt es bislang keine Untersuchungen zu Schwankungen im Tagesverlauf und dem Einfluss anderer Faktoren auf die Messung der Lipidschichtdicke. Material und Methoden: Es wurden jeweils 10 Probanden ohne bekanntes Sicca-Syndrom zu 3 verschiedenen Tageszeiten, an 3 verschiedenen Tagen sowie vor und nach therapeutischer Expression der Meibom-Drüsen mit dem Lipiview®-Interferometer untersucht. Als Vergleichsparameter dienten die Tränenfilmaufrisszeit, die diagnostische Expression, die Tränenmeniskushöhe sowie die subjektiven Symptome gemessen mit dem OSDI-(Ocular Surface Disease Index-)Fragebogen. Ergebnisse: Es zeigte sich eine geringere Schwankungsbreite der Lipidschichtdickenmessung im Tagesverlauf sowie von Tag zu Tag verglichen mit der Tränenfilmaufrisszeit. Eine Expression der Meibom-Drüsen erhöhte die Dicke der Lipidschicht des Tränenfilms signifikant. Zusätzlich bestand eine Korrelation zwischen den Ausgangswerten der Tränenfilmaufrisszeit und der Lipidschichtdicke. Diskussion: Die Untersuchungen zeigen, dass die Lipidschichtdicke gemessen mit dem Lipiview®-Interferometer ein im Zeitverlauf relativ konstanter Parameter zu sein scheint. Außerdem konnte die Expression der Meibom-Drüsen als möglicher Einflussfaktor identifiziert werden. Die hier durchgeführten Untersuchungen wurden an Probanden ohne bekanntes Sicca-Syndrom durchgeführt. Zukünftige Studien sollten untersuchen, ob sich diese Ergebnisse an Patienten mit trockenem Auge bestätigen lassen. Introduction: The quantitative measurement of the tear film lipid layer thickness is a relatively new and promising method. However, so far it has not been investigated whether there is a diurnal or a day to day variability and whether certain factors are confounding the measurement of the lipid layer thickness. Materials and Methods: In three different experimental settings, 10 subjects without known sicca syndrome were examined at three different time points on one day, on three different days and before and after therapeutic expression of the Meibomian glands. As a comparison, the parameters tear film break-up time, tear meniscus height, diagnostic expression of the Meibomian glands and subjective symptoms, determined using the OSDI (ocular surface disease index) questionnaire, were measured. Results: The results of the study showed a smaller variation of the lipid layer thickness measurements during the day and from day to day compared to the tear film break-up time. The expression of the Meibomian glands significantly increased the lipid layer thickness. There was a correlation between the baseline values of tear film break-up time and the lipid layer thickness. Discussion: Our data showed that the lipid layer thickness as measured with the Lipiview® interferometer appears to be a relatively constant parameter over time. In addition, the expression of the Meibomian glands could be identified as a potential confounding factor. In this study we included only healthy subjects without known sicca syndrome. For the future our findings need to be validated in dry eye patients.
- 18 June 2014
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 231 (06) , 603-610
Einflussfaktoren auf die Messung der Lipidschichtdicke des Tränenfilms mittels Interferometrie
Einleitung: Die quantitative Messung der Dicke der Lipidschicht des Tränenfilms ist eine neue und vielversprechende Methode zur Diagnostik von qualitativem Tränenmangel. Allerdings gibt es bislang keine Untersuchungen zu Schwankungen im Tagesverlauf und dem Einfluss anderer Faktoren auf die Messung der Lipidschichtdicke. Material und Methoden: Es wurden jeweils 10 Probanden ohne bekanntes Sicca-Syndrom zu 3 verschiedenen Tageszeiten, an 3 verschiedenen Tagen sowie vor und nach therapeutischer Expression der Meibom-Drüsen mit dem Lipiview®-Interferometer untersucht. Als Vergleichsparameter dienten die Tränenfilmaufrisszeit, die diagnostische Expression, die Tränenmeniskushöhe sowie die subjektiven Symptome gemessen mit dem OSDI-(Ocular Surface Disease Index-)Fragebogen. Ergebnisse: Es zeigte sich eine geringere Schwankungsbreite der Lipidschichtdickenmessung im Tagesverlauf sowie von Tag zu Tag verglichen mit der Tränenfilmaufrisszeit. Eine Expression der Meibom-Drüsen erhöhte die Dicke der Lipidschicht des Tränenfilms signifikant. Zusätzlich bestand eine Korrelation zwischen den Ausgangswerten der Tränenfilmaufrisszeit und der Lipidschichtdicke. Diskussion: Die Untersuchungen zeigen, dass die Lipidschichtdicke gemessen mit dem Lipiview®-Interferometer ein im Zeitverlauf relativ konstanter Parameter zu sein scheint. Außerdem konnte die Expression der Meibom-Drüsen als möglicher Einflussfaktor identifiziert werden. Die hier durchgeführten Untersuchungen wurden an Probanden ohne bekanntes Sicca-Syndrom durchgeführt. Zukünftige Studien sollten untersuchen, ob sich diese Ergebnisse an Patienten mit trockenem Auge bestätigen lassen. Introduction: The quantitative measurement of the tear film lipid layer thickness is a relatively new and promising method. However, so far it has not been investigated whether there is a diurnal or a day to day variability and whether certain factors are confounding the measurement of the lipid layer thickness. Materials and Methods: In three different experimental settings, 10 subjects without known sicca syndrome were examined at three different time points on one day, on three different days and before and after therapeutic expression of the Meibomian glands. As a comparison, the parameters tear film break-up time, tear meniscus height, diagnostic expression of the Meibomian glands and subjective symptoms, determined using the OSDI (ocular surface disease index) questionnaire, were measured. Results: The results of the study showed a smaller variation of the lipid layer thickness measurements during the day and from day to day compared to the tear film break-up time. The expression of the Meibomian glands significantly increased the lipid layer thickness. There was a correlation between the baseline values of tear film break-up time and the lipid layer thickness. Discussion: Our data showed that the lipid layer thickness as measured with the Lipiview® interferometer appears to be a relatively constant parameter over time. In addition, the expression of the Meibomian glands could be identified as a potential confounding factor. In this study we included only healthy subjects without known sicca syndrome. For the future our findings need to be validated in dry eye patients.
- 15 September 2010
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 227 (11) , 879-886
Anatomischer und subjektiver Erfolg einer strukturierten chirurgischen Therapiestrategie zum Management der chronischen Epiphora – eine postoperative Zufriedenheitsanalyse
Hintergrund: Eine Epiphora kann durch Hypersekretion oder Tränenabflussstörung infolge einer relativen oder absoluten Tränenwegstenose (TWS) resultieren. In der Therapie der Tränenabflussstörungen ist in der Regel ein spezifisches chirurgisches Vorgehen erforderlich. Wir stellen die subjektiven und objektiven Ergebnisse eines standardisierten Therapieschemas bei 243 konsekutiv an den Augenkliniken der Universität Lübeck und Würzburg aufgrund einer chronischen, nicht reizbedingten Epiphora behandelten Patienten vor. Patienten und Methoden: Es handelt sich um eine retrospektive Kohortenstudie, in die 243 Patienten mit minimaler Nachbeobachtungszeit von 6 Monaten eingeschlossen wurden. Die durchgeführten Eingriffe umfassten laterale Zügelplastik (n = 72), externe Dakryozystorhinostomie (DCR) bei absoluter (n = 116) und relativer TWS (n = 25), DCR mit kanalikuluschirurgischen Elementen (n = 18) und einfache Kanalikulus-Chirurgie (n = 12). Bei 168 Patienten wurde mittels strukturierter Telefonbefragung allgemeine und kosmetische Zufriedenheit mit dem OP-Ergebnis, das Ausmaß der Epiphora sowie andere Beschwerden erfragt. Postoperative Befunde wurden den Akten entnommen. Ergebnisse: Beschwerdefrei waren 59,5 % der Patienten, eine relative Epiphorareduktion (Epiphora nur draußen/bei Wind) trat bei 19,6 % ein. 20,8 % hatten persistierende Epiphora (draußen und in geschlossenen Räumen). Nach DCR bei absoluter bzw. relativer TWS trat bei 81 % (57 %) Beschwerdefreiheit, bei 7 % (24 %) eine relative Epiphorareduktion ein. Bei 12 % (19 %) persistierte die Epiphora. Der Erfolgsunterschied zwischen beiden Indikationen war mit p = 0,018 signifikant. Patienten mit absoluter TWS waren postoperativ in 95 % frei spülbar. 73,8 % der Patienten waren mit dem Operationsergebnis zufrieden, 7,7 % indifferent, 18,4 % nicht zufrieden. 4 Patienten waren kosmetisch unzufrieden. Schlussfolgerungen: Die chirurgischen Methoden des Therapieschemas reduzierten die Beschwerden bei 79,1 % der befragten Patienten. Bei absoluter postsaccaler TWS kann mittels externer DCR ein anatomischer Erfolg von 95 % und eine subjektive Besserung in 88 % mit guten kosmetischen Ergebnissen erzielt werden. Bei relativer TWS kann zwar in geringerem Maße, jedoch in 81 % eine Besserung der Beschwerden erzielt werden. Unsere Ergebnisse bestätigen somit, dass postoperativer Erfolg vom präoperativen Mechanismus der Epiphora abhängt. Background: Epiphora is the result of hypersecretion or reduced tear outflow because of relative or absolute obstruction of the lacrimal system. For the treatment a specific surgical procedure is usually required. Herein we present the subjective and objective findings of 243 consecutive patients with non-irritative induced epiphora, who underwent an operation in a standardised therapy scheme, which is used at the eye departments of the Universities of Lübeck and Würzburg. Patients and Methods: In a retrospective cohort study 243 patients were included who underwent lateral tarsal strip (n = 72), external dacryocystorhinostomy (DCR) in the case of an absolute nasolacrimal duct obstruction (NLDO) (n = 116) and relative NLDO (n = 25), DCR with canalicular surgery (n = 18) and simple canalicular surgery (n = 12) with a follow-up of at least 6 month. Common patient and cosmetical satisfaction, intensity of symptoms and further symptoms of 168 patients were evaluated by sending a questionnaire with subsequent telephone survey. Objective findings were recorded from hospital charts. Results: 59.5 % of the patients were free of complaints, 19.6 % had an absolute decrease of symptoms (epiphora outside and in windy weather) and 20.8 % persistent epiphora (symptoms both in- and outside persisted). 81 % of patients with absolute NLDO and 57 % with relative NLDO were graded as being free of symptoms, 7 % (24 %) as a relative decrease and 12 % (19 %) as a persistence of symptoms. There was a significant difference in success between these indications (p = 0.018). Patency of the lacrimal system assessed by irrigation was found in 95 % (absolute NLDO). Commonly, 73.8 % were satisfied, 7.7 % indifferent and 18.4 % not satisfied. 4 patients were cosmetically not satisfied. Conclusions: Use of a standardised therapy scheme reduces the symptoms in 79.1 % of the patients. In patients with absolute NLDO external DCR achieves an anatomic success rate of 95 % and a subjective improvement in 88 % with excellent cosmetic results. In comparison with absolute NLDO the success rate of relative NLDO is lower, but still with a subjective improvement in 81 %. Our results show that postoperative success depends on the preoperative cause of the epiphora.
- 15 September 2010
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 227 (11) , 879-886
Anatomischer und subjektiver Erfolg einer strukturierten chirurgischen Therapiestrategie zum Management der chronischen Epiphora – eine postoperative Zufriedenheitsanalyse
Hintergrund: Eine Epiphora kann durch Hypersekretion oder Tränenabflussstörung infolge einer relativen oder absoluten Tränenwegstenose (TWS) resultieren. In der Therapie der Tränenabflussstörungen ist in der Regel ein spezifisches chirurgisches Vorgehen erforderlich. Wir stellen die subjektiven und objektiven Ergebnisse eines standardisierten Therapieschemas bei 243 konsekutiv an den Augenkliniken der Universität Lübeck und Würzburg aufgrund einer chronischen, nicht reizbedingten Epiphora behandelten Patienten vor. Patienten und Methoden: Es handelt sich um eine retrospektive Kohortenstudie, in die 243 Patienten mit minimaler Nachbeobachtungszeit von 6 Monaten eingeschlossen wurden. Die durchgeführten Eingriffe umfassten laterale Zügelplastik (n = 72), externe Dakryozystorhinostomie (DCR) bei absoluter (n = 116) und relativer TWS (n = 25), DCR mit kanalikuluschirurgischen Elementen (n = 18) und einfache Kanalikulus-Chirurgie (n = 12). Bei 168 Patienten wurde mittels strukturierter Telefonbefragung allgemeine und kosmetische Zufriedenheit mit dem OP-Ergebnis, das Ausmaß der Epiphora sowie andere Beschwerden erfragt. Postoperative Befunde wurden den Akten entnommen. Ergebnisse: Beschwerdefrei waren 59,5 % der Patienten, eine relative Epiphorareduktion (Epiphora nur draußen/bei Wind) trat bei 19,6 % ein. 20,8 % hatten persistierende Epiphora (draußen und in geschlossenen Räumen). Nach DCR bei absoluter bzw. relativer TWS trat bei 81 % (57 %) Beschwerdefreiheit, bei 7 % (24 %) eine relative Epiphorareduktion ein. Bei 12 % (19 %) persistierte die Epiphora. Der Erfolgsunterschied zwischen beiden Indikationen war mit p = 0,018 signifikant. Patienten mit absoluter TWS waren postoperativ in 95 % frei spülbar. 73,8 % der Patienten waren mit dem Operationsergebnis zufrieden, 7,7 % indifferent, 18,4 % nicht zufrieden. 4 Patienten waren kosmetisch unzufrieden. Schlussfolgerungen: Die chirurgischen Methoden des Therapieschemas reduzierten die Beschwerden bei 79,1 % der befragten Patienten. Bei absoluter postsaccaler TWS kann mittels externer DCR ein anatomischer Erfolg von 95 % und eine subjektive Besserung in 88 % mit guten kosmetischen Ergebnissen erzielt werden. Bei relativer TWS kann zwar in geringerem Maße, jedoch in 81 % eine Besserung der Beschwerden erzielt werden. Unsere Ergebnisse bestätigen somit, dass postoperativer Erfolg vom präoperativen Mechanismus der Epiphora abhängt. Background: Epiphora is the result of hypersecretion or reduced tear outflow because of relative or absolute obstruction of the lacrimal system. For the treatment a specific surgical procedure is usually required. Herein we present the subjective and objective findings of 243 consecutive patients with non-irritative induced epiphora, who underwent an operation in a standardised therapy scheme, which is used at the eye departments of the Universities of Lübeck and Würzburg. Patients and Methods: In a retrospective cohort study 243 patients were included who underwent lateral tarsal strip (n = 72), external dacryocystorhinostomy (DCR) in the case of an absolute nasolacrimal duct obstruction (NLDO) (n = 116) and relative NLDO (n = 25), DCR with canalicular surgery (n = 18) and simple canalicular surgery (n = 12) with a follow-up of at least 6 month. Common patient and cosmetical satisfaction, intensity of symptoms and further symptoms of 168 patients were evaluated by sending a questionnaire with subsequent telephone survey. Objective findings were recorded from hospital charts. Results: 59.5 % of the patients were free of complaints, 19.6 % had an absolute decrease of symptoms (epiphora outside and in windy weather) and 20.8 % persistent epiphora (symptoms both in- and outside persisted). 81 % of patients with absolute NLDO and 57 % with relative NLDO were graded as being free of symptoms, 7 % (24 %) as a relative decrease and 12 % (19 %) as a persistence of symptoms. There was a significant difference in success between these indications (p = 0.018). Patency of the lacrimal system assessed by irrigation was found in 95 % (absolute NLDO). Commonly, 73.8 % were satisfied, 7.7 % indifferent and 18.4 % not satisfied. 4 patients were cosmetically not satisfied. Conclusions: Use of a standardised therapy scheme reduces the symptoms in 79.1 % of the patients. In patients with absolute NLDO external DCR achieves an anatomic success rate of 95 % and a subjective improvement in 88 % with excellent cosmetic results. In comparison with absolute NLDO the success rate of relative NLDO is lower, but still with a subjective improvement in 81 %. Our results show that postoperative success depends on the preoperative cause of the epiphora.
- 16 May 2007
- Vol. 2 (1) , 158
Generation of organized Lacrimal gland cell spheroids by simulated microgravity.
- 16 May 2007
- Vol. 2 (1) , 158
Generation of organized Lacrimal gland cell spheroids by simulated microgravity.
- 16 May 2007
- Vol. 2 (1) , 159
Amniotic membrane as a matrix for lacrimal gland tissue engineering.
- 23 August 2005
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 222 (08) , 612-614
Keratoplastik - Eine vereinfachte Klassifikation/Terminologie zur Erfassung aktueller Operationskonzepte
In den letzten Jahren ist das Spektrum der Keratoplastik-Techniken durch zahlreiche Varianten bereichert worden. Neben der perforierenden Keratoplastik sind durch Fortschritte bei Dissektionsinstrumentarium und -technik eine größere Zahl von Variationen vor allem der lamellären Hornhautransplantation entstanden und mit individuellen Bezeichnungen und Akronymen versehen worden. In diesem kreativen terminologischen Chaos fehlt jedoch bislang die Eindeutigkeit. Nach einer kurzen Definition der grundlegenden Begriffe schlagen wir hier eine möglichst vereinfachte, klar strukturierte deutschsprachige Nomenklatur einschließlich von Abkürzungen vor, die auch mit im angloamerikanischen Raum verwendeten Termini überwiegend übereinstimmt. Thanks to technical advances the surgical options for corneal grafting have been widely expanded in recent years. Promoted by new instruments and techniques for intrastromal dissection a number of variations of lamellar keratoplasty, including descriptive terms and abbreviations have been suggested. This creative chaos, however, lacks simplicity, specificity and structure. Following a short definition of the basic terms we here present a simplified and clearly structured classification, which also incorporates the Anglo-American terminology and should, therefore, be acceptable for the wider international ophthalmic community.
- 23 August 2005
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 222 (08) , 612-614
Keratoplastik - Eine vereinfachte Klassifikation/Terminologie zur Erfassung aktueller Operationskonzepte
In den letzten Jahren ist das Spektrum der Keratoplastik-Techniken durch zahlreiche Varianten bereichert worden. Neben der perforierenden Keratoplastik sind durch Fortschritte bei Dissektionsinstrumentarium und -technik eine größere Zahl von Variationen vor allem der lamellären Hornhautransplantation entstanden und mit individuellen Bezeichnungen und Akronymen versehen worden. In diesem kreativen terminologischen Chaos fehlt jedoch bislang die Eindeutigkeit. Nach einer kurzen Definition der grundlegenden Begriffe schlagen wir hier eine möglichst vereinfachte, klar strukturierte deutschsprachige Nomenklatur einschließlich von Abkürzungen vor, die auch mit im angloamerikanischen Raum verwendeten Termini überwiegend übereinstimmt. Thanks to technical advances the surgical options for corneal grafting have been widely expanded in recent years. Promoted by new instruments and techniques for intrastromal dissection a number of variations of lamellar keratoplasty, including descriptive terms and abbreviations have been suggested. This creative chaos, however, lacks simplicity, specificity and structure. Following a short definition of the basic terms we here present a simplified and clearly structured classification, which also incorporates the Anglo-American terminology and should, therefore, be acceptable for the wider international ophthalmic community.
- 9 March 2005
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 243 (7) , 706-714
An optimised protocol for the production of autologous serum eyedrops
Background Serum eyedrops have been successfully used in the treatment of severe dry eye, persistent epithelial defects and other severe ocular surface disorders. A number of clinical studies showed a variable efficacy of this approach, but the parameters for the production of this blood product varied significantly. In order to establish an optimised protocol for the production of serum eyedrops, we examined the effect of various clotting times, centrifugation forces, types of diluent and dilutions on the concentration of growth factors, fibronectin, and vitamins in serum and tested the epitheliotrophic capacity of these serum modifications in a cell culture model of human SV-40-immortalised corneal epithelial cells (HCE-T). Methods Serum samples were prepared with a clotting time of 20, 60 or 120 min, a centrifugation force of 500×g or 3,000×g, and diluted with BSS or isotonic saline. The concentrations of EGF, TGF-β1, PDGF-AB, FGF, HGF, fibronectin, vitamin A and vitamin E in these samples were evaluated with ELISA and HPLC. HCE-T cells were incubated for 24, 48, 72, 96 and 144 h with 100, 50, 25, 12.5, 6.25 and 3.125% serum in diluent, and cell proliferation, migration and differentiation were evaluated by means of a luminescence-based ATP assay, a colony-dispersion assay and scanning electron microscopy. Results Using a longer clotting time resulted in an increased concentration of all the epitheliotrophic factors examined in serum; the diffference was statistically significant for EGF, TGF-β1 and HGF. Increasing the g force of centrifugation from 500×g to 3,000×g resulted in significantly less TGF-β1, but more EGF and vitamin A. Cell proliferation was better supported by serum prepared with 3,000×g and diluted with BSS. Serum prepared with a longer clotting time yielded better cell migration and differentiation. Conclusion Clotting time, centrifugation and diluents have a significant impact on the composition and epitheliotrophic effects of serum. A long clotting time (≥120 min), a sharp centrifugation (3,000×g for 15 min) and dilution with BSS improve the ability of serum eyedrops to support proliferation, migration and differentiation of corneal epithelial cells.
- 9 March 2005
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 243 (7) , 706-714
An optimised protocol for the production of autologous serum eyedrops
Background Serum eyedrops have been successfully used in the treatment of severe dry eye, persistent epithelial defects and other severe ocular surface disorders. A number of clinical studies showed a variable efficacy of this approach, but the parameters for the production of this blood product varied significantly. In order to establish an optimised protocol for the production of serum eyedrops, we examined the effect of various clotting times, centrifugation forces, types of diluent and dilutions on the concentration of growth factors, fibronectin, and vitamins in serum and tested the epitheliotrophic capacity of these serum modifications in a cell culture model of human SV-40-immortalised corneal epithelial cells (HCE-T). Methods Serum samples were prepared with a clotting time of 20, 60 or 120 min, a centrifugation force of 500×g or 3,000×g, and diluted with BSS or isotonic saline. The concentrations of EGF, TGF-β1, PDGF-AB, FGF, HGF, fibronectin, vitamin A and vitamin E in these samples were evaluated with ELISA and HPLC. HCE-T cells were incubated for 24, 48, 72, 96 and 144 h with 100, 50, 25, 12.5, 6.25 and 3.125% serum in diluent, and cell proliferation, migration and differentiation were evaluated by means of a luminescence-based ATP assay, a colony-dispersion assay and scanning electron microscopy. Results Using a longer clotting time resulted in an increased concentration of all the epitheliotrophic factors examined in serum; the diffference was statistically significant for EGF, TGF-β1 and HGF. Increasing the g force of centrifugation from 500×g to 3,000×g resulted in significantly less TGF-β1, but more EGF and vitamin A. Cell proliferation was better supported by serum prepared with 3,000×g and diluted with BSS. Serum prepared with a longer clotting time yielded better cell migration and differentiation. Conclusion Clotting time, centrifugation and diluents have a significant impact on the composition and epitheliotrophic effects of serum. A long clotting time (≥120 min), a sharp centrifugation (3,000×g for 15 min) and dilution with BSS improve the ability of serum eyedrops to support proliferation, migration and differentiation of corneal epithelial cells.
- 1 February 2005
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 123 (2) , 253-257
Intraoperative 2-Dimensional Optical Coherence Tomography as a New Tool for Anterior Segment Surgery
We tested a 1310-nm optical coherence tomograph coupled with a beam splitter on the front lens of an operating microscope for intraoperative, noncontact visualization of anterior segment procedures. This new modification of optical coherence tomography technology allows intraoperative, high-resolution, cross-sectional imaging and pachymetry of the cornea and sclera during anterior segment surgery. It is particularly helpful for lamellar dissection techniques such as deep anterior lamellar keratoplasty and trabeculectomy.
- 1 February 2005
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 123 (2) , 253-257
Intraoperative 2-Dimensional Optical Coherence Tomography as a New Tool for Anterior Segment Surgery
We tested a 1310-nm optical coherence tomograph coupled with a beam splitter on the front lens of an operating microscope for intraoperative, noncontact visualization of anterior segment procedures. This new modification of optical coherence tomography technology allows intraoperative, high-resolution, cross-sectional imaging and pachymetry of the cornea and sclera during anterior segment surgery. It is particularly helpful for lamellar dissection techniques such as deep anterior lamellar keratoplasty and trabeculectomy.