Birgit Hailer
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Birgit Hailer has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Peter Van Leeuwen
University Witten/Herdecke
8 shared publications Dietrich Grönemeyer
4 shared publicationsHarald Schäfer
Department of Medicine, Philippusstift, Essen, Germany
3 shared publicationsSabine Auth‐Eisernitz
Department of Medicine, Philippusstift, Essen, Germany
3 shared publicationsDietrich H. W. Grönemeyer
University Witten/Herdecke
2 shared publicationsGregor Eiling
Dept. of Internal Medicine
2 shared publications
Latest Publications
- Open Access
- 12 August 2016
- Published by VM Media Group sp. z o.o in Cardiology Journal
- Vol. 23 (4) , 422-428
A novel cross-sector telemedical approach to detect arrhythmia in primary care patients with palpitations using a patient-activated event recorder
The investigated cross-sector telemetric network is a feasible approach to detect arrhythmia in patients with palpitations and may have high impact on further treatment, notably in those at risk for stroke due to AF.
- 12 August 2016
- Published by VM Media Group sp. z o.o in Cardiology Journal
- Vol. 23 (4) , 422-428
Open AccessA novel cross-sector telemedical approach to detect arrhythmia in primary care patients with palpitations using a patient-activated event recorder
The investigated cross-sector telemetric network is a feasible approach to detect arrhythmia in patients with palpitations and may have high impact on further treatment, notably in those at risk for stroke due to AF.
- 1 July 2015
- Published by Elsevier in Science Bulletin
- Vol. 60 (14) , 1235-1240
Sparse current source reconstruction in MCG
- 1 July 2015
- Published by Elsevier in Science Bulletin
- Vol. 60 (14) , 1235-1240
Sparse current source reconstruction in MCG
- 1 January 2010
- Published by Springer Nature in IFMBE Proceedings
- p. 413-416
Nondipolar Content of Cardiac Magnetic Field Maps in Patients after ST Elevation Myocardial Infarction
- 1 January 2010
- Published by Springer Nature in IFMBE Proceedings
- p. 413-416
Nondipolar Content of Cardiac Magnetic Field Maps in Patients after ST Elevation Myocardial Infarction
- 1 January 2010
- Published by Springer Nature in IFMBE Proceedings
- p. 436-439
Magnetic Field Map Orientation in Patients after ST Elevation Myocardial Infarction
- 1 January 2010
- Published by Springer Nature in IFMBE Proceedings
- p. 436-439
Magnetic Field Map Orientation in Patients after ST Elevation Myocardial Infarction
- 1 March 2008
- Published by Springer Nature in Herz
- Vol. 33 (2) , 153-157
Herzinfarktverbund Essen: Ergebnisse nach 1 Jahr
- 1 March 2008
- Published by Springer Nature in Herz
- Vol. 33 (2) , 153-157
Herzinfarktverbund Essen: Ergebnisse nach 1 Jahr
- 1 July 2007
- p. 20-2
Comparison of magnetocardiography and electrocardiography.
Automated techniques were developed for the measurement of cardiac repolarisation using magnetocardiography. This was achieved by collaboration with the Physikalisch-Technische Bundesanstalt (PTB), Berlin, Germany and the Grönemeyer Institute of Microtherapy, Bochum, Germany, to obtain recordings of magnetocardiograms (MCGs) in cardiac patients and healthy subjects. Manual and automated ventricular repolarisation measurements from MCGs were evaluated to determine the clinical relevance of these measurements compared with electrocardiograms (ECGs). Results showed that MCG and ECG T-wave shapes differed and that manual repolarisation measurement was significantly influenced by T-wave amplitude. Automatic measurements of repolarisation in both MCGs and ECGs differed between techniques. The effects of filtering on the waveforms showed that filtering in some MCG research systems could significantly influence the results, with 20 ms differences common. In addition, MCGs were better able to identify differences in the distribution of cardiac magnetic field strength during repolarisation and depolarisation between normal subjects and cardiac patients. Differences were also determined in ventricular repolarisation between MCGs and ECGs, which cannot be explained by channel/lead numbers or amplitude effects alone. The techniques developed are essential, because of the many extra MCG channels to analyse, and will encourage the use of MCG facilities.
- 1 July 2007
- p. 20-2
Comparison of magnetocardiography and electrocardiography.
Automated techniques were developed for the measurement of cardiac repolarisation using magnetocardiography. This was achieved by collaboration with the Physikalisch-Technische Bundesanstalt (PTB), Berlin, Germany and the Grönemeyer Institute of Microtherapy, Bochum, Germany, to obtain recordings of magnetocardiograms (MCGs) in cardiac patients and healthy subjects. Manual and automated ventricular repolarisation measurements from MCGs were evaluated to determine the clinical relevance of these measurements compared with electrocardiograms (ECGs). Results showed that MCG and ECG T-wave shapes differed and that manual repolarisation measurement was significantly influenced by T-wave amplitude. Automatic measurements of repolarisation in both MCGs and ECGs differed between techniques. The effects of filtering on the waveforms showed that filtering in some MCG research systems could significantly influence the results, with 20 ms differences common. In addition, MCGs were better able to identify differences in the distribution of cardiac magnetic field strength during repolarisation and depolarisation between normal subjects and cardiac patients. Differences were also determined in ventricular repolarisation between MCGs and ECGs, which cannot be explained by channel/lead numbers or amplitude effects alone. The techniques developed are essential, because of the many extra MCG channels to analyse, and will encourage the use of MCG facilities.
- 30 June 2007
- Published by Elsevier in International Congress Series
- Vol. 1300, 488-491
Magnetocardiography in hypertensive and coronary artery disease
- 30 June 2007
- Published by Elsevier in International Congress Series
- Vol. 1300, 488-491
Magnetocardiography in hypertensive and coronary artery disease
- 20 April 2005
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 10 (2) , 188-196
The Value of Magnetocardiography in the Course of Coronary Intervention
The noninvasive detection of restenosis after percutaneous coronary intervention (PCI) remains a clinical challenge. Previous studies have shown that magnetocardiograms reveal obvious changes in patients with coronary artery disease (CAD) and normal electrocardiogram (ECG) at rest. The present study aimed to evaluate the potential of magnetocardiography (MCG) for the detection of electrophysiological changes in the course of successful PCI. Twelve-lead ECG and unshielded four-channel MCG (SQUID AG, Essen, Germany) were registered at nine prethoracic sites in 50 patients with CAD (62 +/- 10 years; EF = 76 +/- 11%; registration: before, 24 hours, and 1 month (n = 25) after PCI) and 57 normals (51 +/- 9 years). Current density vector (CDV) maps were reconstructed within the ST-T interval and classified from category 0 (normal) to category 4 (grossly abnormal). In both groups and at all registration times, the percentage of each category of maps was calculated and compared. Most CDV maps of normals were classified as category 0, 1, or 2 compared to CAD patients before PCI with most maps of category 3 and 4 (P < 0.0005). Twenty-four hours after PCI, more maps were classified as category 2 (P < 0.05) and less as category 4 (P < 0.005). One month after PCI the MCG results further improved: more maps were classified as category 1 (P < 0.05) and 2 (P < 0.005) and less maps as category 4 (P < 0.0001). The ECG remained unchanged in the course of PCI. Unshielded four-channel MCG reveals obvious changes in the course of successful PCI on the basis of CDV map reconstruction during repolarization. The method seems to be suitable for the follow-up of patients after PCI.
- 20 April 2005
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 10 (2) , 188-196
The Value of Magnetocardiography in the Course of Coronary Intervention
The noninvasive detection of restenosis after percutaneous coronary intervention (PCI) remains a clinical challenge. Previous studies have shown that magnetocardiograms reveal obvious changes in patients with coronary artery disease (CAD) and normal electrocardiogram (ECG) at rest. The present study aimed to evaluate the potential of magnetocardiography (MCG) for the detection of electrophysiological changes in the course of successful PCI. Twelve-lead ECG and unshielded four-channel MCG (SQUID AG, Essen, Germany) were registered at nine prethoracic sites in 50 patients with CAD (62 +/- 10 years; EF = 76 +/- 11%; registration: before, 24 hours, and 1 month (n = 25) after PCI) and 57 normals (51 +/- 9 years). Current density vector (CDV) maps were reconstructed within the ST-T interval and classified from category 0 (normal) to category 4 (grossly abnormal). In both groups and at all registration times, the percentage of each category of maps was calculated and compared. Most CDV maps of normals were classified as category 0, 1, or 2 compared to CAD patients before PCI with most maps of category 3 and 4 (P < 0.0005). Twenty-four hours after PCI, more maps were classified as category 2 (P < 0.05) and less as category 4 (P < 0.005). One month after PCI the MCG results further improved: more maps were classified as category 1 (P < 0.05) and 2 (P < 0.005) and less maps as category 4 (P < 0.0001). The ECG remained unchanged in the course of PCI. Unshielded four-channel MCG reveals obvious changes in the course of successful PCI on the basis of CDV map reconstruction during repolarization. The method seems to be suitable for the follow-up of patients after PCI.
- 14 January 2005
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 28 (1) , 8-16
The Value of Magnetocardiography in Patients with and Without Relevant Stenoses of the Coronary Arteries Using an Unshielded System
Background: The diagnostic management of patients with chest pain remains a clinical challenge. Magnetocardiography (MCG) is a noninvasive method for the recording of cardiac electromagnetic signals at multiple sites above the chest cage. Contrary to electrocardiogram (ECG) the magnetic field is unaltered by surrounding tissues. The present study aimed to analyze the diagnostic value of an unshielded four‐channel MCG for the detection of coronary artery disease (CAD) in patients with chest pain. Methods: The study included 417 subjects: 177 patients with angiographically documented CAD (stenoses ≥50%), 123 symptomatic patients without hemodynamically relevant stenosis (nCAD) and 117 healthy subjects. Twelve‐lead ECG was obtained in all subjects. The magnetocardiography recordings were taken from 36 positions at rest. From these current density vector maps were generated during the ST‐T interval. Each map was classified using a classification system with a scale from 0 (normal) to 4 (grossly abnormal). Results: While the ECG was normal in all subjects the MCG revealed typical differences. In normals most maps were classified as category 0, 1 or 2, in nCAD and more so in CAD patients the categories 3 and 4 prevailed. Using a cut‐off value of 39.2% for the discrimination between normals and CAD patients sensitivity was 73.3%, specificity 70.1%. Conclusion: Contrary to ECG, unshielded MCG reveals significant differences between normals and symptomatic patients with and without relevant stenoses using current density reconstruction during repolarization at rest. This method might be a suitable noninvasive tool for the management of patients with chest pain.
- 14 January 2005
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 28 (1) , 8-16
The Value of Magnetocardiography in Patients with and Without Relevant Stenoses of the Coronary Arteries Using an Unshielded System
Background: The diagnostic management of patients with chest pain remains a clinical challenge. Magnetocardiography (MCG) is a noninvasive method for the recording of cardiac electromagnetic signals at multiple sites above the chest cage. Contrary to electrocardiogram (ECG) the magnetic field is unaltered by surrounding tissues. The present study aimed to analyze the diagnostic value of an unshielded four‐channel MCG for the detection of coronary artery disease (CAD) in patients with chest pain. Methods: The study included 417 subjects: 177 patients with angiographically documented CAD (stenoses ≥50%), 123 symptomatic patients without hemodynamically relevant stenosis (nCAD) and 117 healthy subjects. Twelve‐lead ECG was obtained in all subjects. The magnetocardiography recordings were taken from 36 positions at rest. From these current density vector maps were generated during the ST‐T interval. Each map was classified using a classification system with a scale from 0 (normal) to 4 (grossly abnormal). Results: While the ECG was normal in all subjects the MCG revealed typical differences. In normals most maps were classified as category 0, 1 or 2, in nCAD and more so in CAD patients the categories 3 and 4 prevailed. Using a cut‐off value of 39.2% for the discrimination between normals and CAD patients sensitivity was 73.3%, specificity 70.1%. Conclusion: Contrary to ECG, unshielded MCG reveals significant differences between normals and symptomatic patients with and without relevant stenoses using current density reconstruction during repolarization at rest. This method might be a suitable noninvasive tool for the management of patients with chest pain.
- 30 November 2004
- Vol. 2004, 82
Detection of coronary artery disease with MCG.
The diagnosis of cardiac ischemia related to coronary artery disease (CAD) is a clinical challenge. Despite many methods clinically available, the predictive value of each is still limited. Magnetocardiography (MCG) offers new insights in the electrogenesis of the disease. In the last decade a number of studies using biomagnetometers have dealt with the identification of CAD patients using coronary angiography as a gold standard. As the availability of these systems is limited, studies have focused either on exercise-induced ischemia or on chronic ischemia and the infarct scar at rest. Different parameters have been developed based on signal morphology, time intervals, source parameters or magnetic field map analysis. Concerning signal morphology, main work concentrates on ST-depression, ST-T signal amplitude as well as QRS and ST-T integrals. Dealing with time intervals, most studies focus on the QT interval. The evaluation of of QT dispersion spatially in the MCG, reflecting regional heterogeneity of repolarization, improved the identification of CAD patients. Besides the calculation of the equivalent current dipole during de- and repolarization, parameters of the magnetic field orientation were used to identify CAD patients and localize exercise-induced ischemic regions. Heart rate adjusted alteration in the magnetic field orientation allowed the quantification of ischemia-induced changes in MCG. The estimation of current density (CDV) further enabled to separate healthy subjects from CAD patients at rest. In the course of interventional therapy CDV maps returned toward that of healthy subjects.Thus, there is justification for routine clinical use of the MCG in the diagnosis of CAD.
- 30 November 2004
- Vol. 2004, 82
Detection of coronary artery disease with MCG.
The diagnosis of cardiac ischemia related to coronary artery disease (CAD) is a clinical challenge. Despite many methods clinically available, the predictive value of each is still limited. Magnetocardiography (MCG) offers new insights in the electrogenesis of the disease. In the last decade a number of studies using biomagnetometers have dealt with the identification of CAD patients using coronary angiography as a gold standard. As the availability of these systems is limited, studies have focused either on exercise-induced ischemia or on chronic ischemia and the infarct scar at rest. Different parameters have been developed based on signal morphology, time intervals, source parameters or magnetic field map analysis. Concerning signal morphology, main work concentrates on ST-depression, ST-T signal amplitude as well as QRS and ST-T integrals. Dealing with time intervals, most studies focus on the QT interval. The evaluation of of QT dispersion spatially in the MCG, reflecting regional heterogeneity of repolarization, improved the identification of CAD patients. Besides the calculation of the equivalent current dipole during de- and repolarization, parameters of the magnetic field orientation were used to identify CAD patients and localize exercise-induced ischemic regions. Heart rate adjusted alteration in the magnetic field orientation allowed the quantification of ischemia-induced changes in MCG. The estimation of current density (CDV) further enabled to separate healthy subjects from CAD patients at rest. In the course of interventional therapy CDV maps returned toward that of healthy subjects.Thus, there is justification for routine clinical use of the MCG in the diagnosis of CAD.