Nei Fernandes Lopes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nei Fernandes Lopes has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Francisco de Almeida Lobo
Universidade Federal de Mato Grosso, Brasil
1 shared publication - Marco Antonio Oliva
Universidade Federal de Viçosa
1 shared publication Moacyr Maestri
Universidade Federal de Viçosa, Brasil
1 shared publication- Morethson Resende
Embrapa Milho e Sorgo, Brasil
1 shared publication
Latest Publications
- Open Access
- 1 February 2004
- Published by FapUNIFESP (SciELO) in Pesquisa Agropecuária Brasileira
- Vol. 39 (2) , 113-121
Infrared thermometry to schedule irrigation of common bean
The objective of this work was to determine the critical irrigation time for common bean (Phaseolus vulgaris L. cv. Carioca) using infrared thermometry. Five treatments were analyzed. Canopy temperature differences between plants and a well-watered control about 1, 2, 3, 4, and 5±0.5ºC were tested. Physiological variables and plant growth were analyzed to establish the best time to irrigate. There was a significant linear correlation between the index and stomatal resistance, transpiration rate, and leaf water potential. Although significant linear correlation between the index and mean values of total dry matter, absolute growth rate, and leaf area index was found, no correlation was found with other growth index like relative growth rate, net assimilation rate, and leaf area ratio. Plants irrigated when their canopy temperature was 3±0.5ºC above the control had their relative growth rate mean value increased up to 59.7%, yielding 2,260.2 kg ha-1, with a reduction of 38.0% in the amount of water used. Plants irrigated when their canopy temperature was 4±0.5ºC yielded 1,907.6 kg ha-1, although their relative growth rate mean value was 4.0% below the control. These results show that the best moment to irrigate common bean is when their canopy temperature is between 3ºC and 4±0.5ºC above the control.
- 1 February 2004
- Published by FapUNIFESP (SciELO) in Pesquisa Agropecuária Brasileira
- Vol. 39 (2) , 113-121
Open AccessInfrared thermometry to schedule irrigation of common bean
The objective of this work was to determine the critical irrigation time for common bean (Phaseolus vulgaris L. cv. Carioca) using infrared thermometry. Five treatments were analyzed. Canopy temperature differences between plants and a well-watered control about 1, 2, 3, 4, and 5±0.5ºC were tested. Physiological variables and plant growth were analyzed to establish the best time to irrigate. There was a significant linear correlation between the index and stomatal resistance, transpiration rate, and leaf water potential. Although significant linear correlation between the index and mean values of total dry matter, absolute growth rate, and leaf area index was found, no correlation was found with other growth index like relative growth rate, net assimilation rate, and leaf area ratio. Plants irrigated when their canopy temperature was 3±0.5ºC above the control had their relative growth rate mean value increased up to 59.7%, yielding 2,260.2 kg ha-1, with a reduction of 38.0% in the amount of water used. Plants irrigated when their canopy temperature was 4±0.5ºC yielded 1,907.6 kg ha-1, although their relative growth rate mean value was 4.0% below the control. These results show that the best moment to irrigate common bean is when their canopy temperature is between 3ºC and 4±0.5ºC above the control.