Jian-Ya Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jian-Ya Wang has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Bin Xue
School of Petrochemical Engineering, Shenyang University of Technology
1 shared publicationZhao-Lun Fang
1 shared publicationZhao-Lun Fang
Research Center for Analytical Sciences, Northeastern University, Shenyang 110006, P. R. China
1 shared publication
Latest Publications
- Open Access
- 12 September 2006
- Published by Springer Nature in Analytical Sciences
- Vol. 22 (9) , 1233-1236
Sequential Injection Analysis for Cr(VI) and Cr(III) with Renewable Surface Reflection Spectrophotometry
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 12 September 2006
- Published by Springer Nature in Analytical Sciences
- Vol. 22 (9) , 1233-1236
Open AccessSequential Injection Analysis for Cr(VI) and Cr(III) with Renewable Surface Reflection Spectrophotometry
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 31 May 2006
- Published by Elsevier in Chemical Research in Chinese Universities
- Vol. 22 (3) , 287-291
Enzymatic Determination of Glucose by Optical-Fiber Sensor Sequential Injection Renewable Surface Spectrophotometry
- 31 May 2006
- Published by Elsevier in Chemical Research in Chinese Universities
- Vol. 22 (3) , 287-291
Enzymatic Determination of Glucose by Optical-Fiber Sensor Sequential Injection Renewable Surface Spectrophotometry
- 1 February 2002
- Vol. 22 (1) , 126-30
[Studies on a sequential injection renewable surface reflectance spectrophotometric system using a microchip flow cell].
A microchip flow cell was developed for flow injection renewable surface assay by reflectance spectrophotometry. The flow cell was coupled to a sequential injection system and optical fiber photometric detection system. The flow cell featured a three-layer structure. The flow channel was cut into a silicone rubber membrance which formed the middle layer, and a porous filter was inlayed across a widened section of the channel to trap microbeads introduced into the flow cell. The area of the detection window of the flow cell was approximately 3.6 mm2, the volume of the bead trapped in the flow cell was 2.2 microL, the depth of the bead layer was 600 microns. A multistrand bifurcated optical fiber was coupled with incident light, detector and flow cell. The chromogenic reaction of Cr(VI) with 1,5-diphenylcarbohydrazide (DPC) which was adsorbed on trapped Polysorb C-18 beads was used as a model reaction to optimize the flow cell design and the experimental system. The reflectance of the renewable reaction surface was monitored at 540 nm. With 100 microL sample loaded and 1.0 mL.min-1 carrier flow rate, the linear response range was 0-0.6 microgram.mL-1 Cr(VI). A detection limit (3 sigma) of 6 ng.mL-1, precision of 1.5% RSD(n = 11), and a throughput of 64 samples per hour were achieved. Considerations in system and flow cell design, the influence of depth of the bead layer, weight of beads used, and the flow rates of carrier stream on the performance were discussed.
- 1 February 2002
- Vol. 22 (1) , 126-30
[Studies on a sequential injection renewable surface reflectance spectrophotometric system using a microchip flow cell].
A microchip flow cell was developed for flow injection renewable surface assay by reflectance spectrophotometry. The flow cell was coupled to a sequential injection system and optical fiber photometric detection system. The flow cell featured a three-layer structure. The flow channel was cut into a silicone rubber membrance which formed the middle layer, and a porous filter was inlayed across a widened section of the channel to trap microbeads introduced into the flow cell. The area of the detection window of the flow cell was approximately 3.6 mm2, the volume of the bead trapped in the flow cell was 2.2 microL, the depth of the bead layer was 600 microns. A multistrand bifurcated optical fiber was coupled with incident light, detector and flow cell. The chromogenic reaction of Cr(VI) with 1,5-diphenylcarbohydrazide (DPC) which was adsorbed on trapped Polysorb C-18 beads was used as a model reaction to optimize the flow cell design and the experimental system. The reflectance of the renewable reaction surface was monitored at 540 nm. With 100 microL sample loaded and 1.0 mL.min-1 carrier flow rate, the linear response range was 0-0.6 microgram.mL-1 Cr(VI). A detection limit (3 sigma) of 6 ng.mL-1, precision of 1.5% RSD(n = 11), and a throughput of 64 samples per hour were achieved. Considerations in system and flow cell design, the influence of depth of the bead layer, weight of beads used, and the flow rates of carrier stream on the performance were discussed.