Hidehito Nanto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hidehito Nanto has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Yoshinori Takei
AMS R&D Center, Kanazawa Institute of Tech
5 shared publications K. Wada
Dept. of Electrical and Electronic Systems Engineering, Kyushu University
4 shared publicationsS. Kanae
Dept. of Electrical and Electronic Systems Engineering, Kyushu University
4 shared publicationsZ.J. Yang
Dept. of Electrical and Electronic Systems Engineering, Kyushu University
3 shared publicationsA. Kinbara
1 shared publicationE. Kusano
1 shared publication
Latest Publications
- 21 November 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 62 (1) , 010505
Optically stimulated luminescence dosimeters: principles, phosphors and applications
This review paper discusses the basics of the optically stimulated luminescence (OSL) phenomenon, phosphors for OSL, functional design of OSL phosphors, and application areas of the OSL phenomenon, such as radiation dose monitoring for individual and environmental, computed radiography for medical and dental diagnosis, dating, security, archaeological dating, and autoradiography for drug discovery. Finally, the future prospects of the OSL phenomenon as passive-type dosimeters are mentioned.
- 21 November 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 62 (1) , 010505
Optically stimulated luminescence dosimeters: principles, phosphors and applications
This review paper discusses the basics of the optically stimulated luminescence (OSL) phenomenon, phosphors for OSL, functional design of OSL phosphors, and application areas of the OSL phenomenon, such as radiation dose monitoring for individual and environmental, computed radiography for medical and dental diagnosis, dating, security, archaeological dating, and autoradiography for drug discovery. Finally, the future prospects of the OSL phenomenon as passive-type dosimeters are mentioned.
- Open Access
- 12 December 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 706
Photostimulable Phosphor Glass for Ionizing Radiation Monitoring
Silver (Ag+) doped phosphate glass after exposure to ionizing radiation has an intense luminescence by stimulating with ultra-violet light. This phenomenon is called radiophotoluminescence (RPL). The RPL intensity was increased linearly with increasing X-ray irradiation dose up to about 1000 Gy. Small amount of bead-type RPL glass as large as about 0.05mm was well prepared with a jet flame system. It was confirmed that the RPL glass beads could be used as passive-type radiation dosimeters. Visualization and monitoring system of radiation dose distribution utilizing RPL phenomenon in the Ag+-doped phosphate glass are developed in this study. In the presentation, the basic luminescence properties are reported as well as the application of Ag+-doped phosphate glass beads to radiation dose distribution monitoring.
- 12 December 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 706
Open AccessPhotostimulable Phosphor Glass for Ionizing Radiation Monitoring
Silver (Ag+) doped phosphate glass after exposure to ionizing radiation has an intense luminescence by stimulating with ultra-violet light. This phenomenon is called radiophotoluminescence (RPL). The RPL intensity was increased linearly with increasing X-ray irradiation dose up to about 1000 Gy. Small amount of bead-type RPL glass as large as about 0.05mm was well prepared with a jet flame system. It was confirmed that the RPL glass beads could be used as passive-type radiation dosimeters. Visualization and monitoring system of radiation dose distribution utilizing RPL phenomenon in the Ag+-doped phosphate glass are developed in this study. In the presentation, the basic luminescence properties are reported as well as the application of Ag+-doped phosphate glass beads to radiation dose distribution monitoring.
- 30 May 2006
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 119 (1-4) , 398-401
Eu-doped CsBr phosphor as a new optically-stimulable phosphor material for medical x-ray imaging sensor
CsBr phosphor ceramics doped with different luminescence centres such as In2O3, Eu2O3, EuCl3, SmCl3, TbCl3, GdCl3 or NdCl3 as the candidate for a new optically-stimulable phosphor for medical X-ray imaging sensor were prepared using a conventional ceramic fabrication process. It was found that X-ray-irradiated Eu-doped CsBr (CsBr:Eu) exhibited intense optically stimulated luminescence (OSL). The peak wavelength of the OSL emission and stimulation spectra of CsBr:Eu phosphor ceramic sample were 450 and 690 nm, respectively. The dependence of OSL properties on the conditions of preparation of phosphor ceramic samples, such as Eu concentration, sintering temperature and sintering time, were studied. The optimum preparation conditions were also studied. It was found that the OSL intensity of CsBr:Eu phosphor ceramics fabricated under optimum preparation conditions is higher than that of commercially available imaging plates using BaFBr:Eu.
- 30 May 2006
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 119 (1-4) , 398-401
Eu-doped CsBr phosphor as a new optically-stimulable phosphor material for medical x-ray imaging sensor
CsBr phosphor ceramics doped with different luminescence centres such as In2O3, Eu2O3, EuCl3, SmCl3, TbCl3, GdCl3 or NdCl3 as the candidate for a new optically-stimulable phosphor for medical X-ray imaging sensor were prepared using a conventional ceramic fabrication process. It was found that X-ray-irradiated Eu-doped CsBr (CsBr:Eu) exhibited intense optically stimulated luminescence (OSL). The peak wavelength of the OSL emission and stimulation spectra of CsBr:Eu phosphor ceramic sample were 450 and 690 nm, respectively. The dependence of OSL properties on the conditions of preparation of phosphor ceramic samples, such as Eu concentration, sintering temperature and sintering time, were studied. The optimum preparation conditions were also studied. It was found that the OSL intensity of CsBr:Eu phosphor ceramics fabricated under optimum preparation conditions is higher than that of commercially available imaging plates using BaFBr:Eu.
- 5 May 2006
- Published by The Institute of Systems, Control and Information Engineers in Proceedings of the ISCIE International Symposium on Stochastic Systems Theory and its Applications
- Vol. 2006, 107-112
Sequential Updating of The Error Covariance Matrix in Subspace Identification for Time-varying System
Recursive updating algorithms of error covariance matrices in subspace identification methods for time-varying systems are derived. The proposed algorithms can be applied to estimate the system parameters which are slowly time-varying. The algorithms are based on the fact that the subspace extraction amounts to computing singular value decomposition of the SC of the input submatrix in data product moments and the SC can be interpreted as the least squares residuals. We have proposed an unified framework for the MOESP type of the subspace identification method by using the SC. In this paper, we show the aforementioned time-varying case can be also treated in the proposed framework.
- 5 May 2006
- Published by The Institute of Systems, Control and Information Engineers in Proceedings of the ISCIE International Symposium on Stochastic Systems Theory and its Applications
- Vol. 2006, 107-112
Sequential Updating of The Error Covariance Matrix in Subspace Identification for Time-varying System
Recursive updating algorithms of error covariance matrices in subspace identification methods for time-varying systems are derived. The proposed algorithms can be applied to estimate the system parameters which are slowly time-varying. The algorithms are based on the fact that the subspace extraction amounts to computing singular value decomposition of the SC of the input submatrix in data product moments and the SC can be interpreted as the least squares residuals. We have proposed an unified framework for the MOESP type of the subspace identification method by using the SC. In this paper, we show the aforementioned time-varying case can be also treated in the proposed framework.
- 5 May 2005
- Published by The Institute of Systems, Control and Information Engineers in Proceedings of the ISCIE International Symposium on Stochastic Systems Theory and its Applications
- Vol. 2005, 72-77
Recursive Subspace Identification Using A Unified Approach
Using a unified approach, recursive subspace identification algorithms are derived for the MOESP type of subspace methods. The proposed approach is based on the fact that the subspace extraction amounts to computing singular value decomposition of the Schur complement (SC) of the input submatrix in data product moments and the SC can be interpreted as the least squares residuals.
- 5 May 2005
- Published by The Institute of Systems, Control and Information Engineers in Proceedings of the ISCIE International Symposium on Stochastic Systems Theory and its Applications
- Vol. 2005, 72-77
Recursive Subspace Identification Using A Unified Approach
Using a unified approach, recursive subspace identification algorithms are derived for the MOESP type of subspace methods. The proposed approach is based on the fact that the subspace extraction amounts to computing singular value decomposition of the Schur complement (SC) of the input submatrix in data product moments and the SC can be interpreted as the least squares residuals.
- Open Access
- 5 May 2004
- Published by The Institute of Systems, Control and Information Engineers in Proceedings of the ISCIE International Symposium on Stochastic Systems Theory and its Applications
- Vol. 2004, 193-198
A Unified Approach for Subspace Identification Algorithms
In this paper, a unified approach for subspace-based identification methods by using Schur complement is proposed. MOESP (MIMO output error state space model identification) type of subspace idenitification methods are well known as an elementary subspace method. The extensions of the MOESP with instrumental variables (IV) have been proposed, which can be useful to solve the stochastic identification problems. We consider data product moments corresponding to the data matrix in the MOESP algorithms, then we show that the IV matrices in the MOESP-based methods can be expressed as modifications of the data product moment, and it enable us to treat the IV-MOESP algorithms under a unified framework even if the errors-in-variables (EIV) problems are considered.
- 5 May 2004
- Published by The Institute of Systems, Control and Information Engineers in Proceedings of the ISCIE International Symposium on Stochastic Systems Theory and its Applications
- Vol. 2004, 193-198
Open AccessA Unified Approach for Subspace Identification Algorithms
In this paper, a unified approach for subspace-based identification methods by using Schur complement is proposed. MOESP (MIMO output error state space model identification) type of subspace idenitification methods are well known as an elementary subspace method. The extensions of the MOESP with instrumental variables (IV) have been proposed, which can be useful to solve the stochastic identification problems. We consider data product moments corresponding to the data matrix in the MOESP algorithms, then we show that the IV matrices in the MOESP-based methods can be expressed as modifications of the data product moment, and it enable us to treat the IV-MOESP algorithms under a unified framework even if the errors-in-variables (EIV) problems are considered.
- Open Access
- 5 May 2003
- Published by The Institute of Systems, Control and Information Engineers in Proceedings of the ISCIE International Symposium on Stochastic Systems Theory and its Applications
- Vol. 2003, 195-200
Subspace Identification for Errors-in-Variables Models using Schur Complement Approach
In this paper, an interpretation of subspace-based identification methods with Schur complement approach is proposed. MOESP (MIMO output error state space model identification) algorithms are well known as an elementary subspace method. The extensions of the MOESP with instrumental variables (IV) have been proposed in literatures, which can be useful to solve the stochastic identification problems. Data product moments corresponding to the data matrix in the MOESP algorithms are used. Then we show that the IV extensions in the MOESP-based methods can be expressed as modifications of the data product moment, and it enable us to treat the MOESP-based algorithms under a same framework even if the errors-in-variables (EIV) problems are considered.
- 5 May 2003
- Published by The Institute of Systems, Control and Information Engineers in Proceedings of the ISCIE International Symposium on Stochastic Systems Theory and its Applications
- Vol. 2003, 195-200
Open AccessSubspace Identification for Errors-in-Variables Models using Schur Complement Approach
In this paper, an interpretation of subspace-based identification methods with Schur complement approach is proposed. MOESP (MIMO output error state space model identification) algorithms are well known as an elementary subspace method. The extensions of the MOESP with instrumental variables (IV) have been proposed in literatures, which can be useful to solve the stochastic identification problems. Data product moments corresponding to the data matrix in the MOESP algorithms are used. Then we show that the IV extensions in the MOESP-based methods can be expressed as modifications of the data product moment, and it enable us to treat the MOESP-based algorithms under a same framework even if the errors-in-variables (EIV) problems are considered.
- 1 July 2002
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 100 (1) , 385-388
Optically Stimulated Luminescence in an Imaging Plate Using BaFI:Eu
BaFI:Eu phosphors are fabricated using a new method of synthesis: liquid phase synthesis, in which the phosphor particles are formed through the association of Ba2+ ions, F- ions and Eu2+ ions in solution. An intense optically stimulated luminescence (OSL) peak at about 410 nm is observed by stimulating X ray irradiated BaFI:Eu phosphor with about 550-750 nm light. It is found that the peak wavelength of the optically stimulation spectrum is about 690 nm. This result suggests that the semiconductor laser can be used as the stimulating light source. It is also found that the OSL intensity is increased with increasing the X ray dose. The BaFI:Eu phosphor as a photostimulable material for the imaging place of a computed radiography system provides the following advantages: (1) high X ray absorption coefficient, (2) high monodispersion in size which would contribute to sharp images, (3) high OSL and thus low luminescence mottle and (4) high DQE (detective quantum efficiency).
- 1 July 2002
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 100 (1) , 385-388
Optically Stimulated Luminescence in an Imaging Plate Using BaFI:Eu
BaFI:Eu phosphors are fabricated using a new method of synthesis: liquid phase synthesis, in which the phosphor particles are formed through the association of Ba2+ ions, F- ions and Eu2+ ions in solution. An intense optically stimulated luminescence (OSL) peak at about 410 nm is observed by stimulating X ray irradiated BaFI:Eu phosphor with about 550-750 nm light. It is found that the peak wavelength of the optically stimulation spectrum is about 690 nm. This result suggests that the semiconductor laser can be used as the stimulating light source. It is also found that the OSL intensity is increased with increasing the X ray dose. The BaFI:Eu phosphor as a photostimulable material for the imaging place of a computed radiography system provides the following advantages: (1) high X ray absorption coefficient, (2) high monodispersion in size which would contribute to sharp images, (3) high OSL and thus low luminescence mottle and (4) high DQE (detective quantum efficiency).