Patrick C. Brennan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Patrick C. Brennan has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Mark F. McEntee
University College Cork
5 shared publications D. O'Leary
UCD School of Diagnostic Imaging, Herbert Avenue, Dublin 4, Ireland
2 shared publicationsDavid Manning
2 shared publicationsJohn Ryan
2 shared publications- Louise Rainford
Radiography and Diagnostic Imaging, School of Medicine, University College Dublin, Ireland
2 shared publications Aaron O’bEirne
1 shared publication
Latest Publications
- 1 June 2013
- Published by Elsevier in Academic Radiology
- Vol. 20 (6) , 712-720
The Effect of JPEG2000 Compression on Detection of Skull Fractures
- 1 June 2013
- Published by Elsevier in Academic Radiology
- Vol. 20 (6) , 712-720
The Effect of JPEG2000 Compression on Detection of Skull Fractures
- 31 May 2010
- Published by Elsevier in Radiography
- Vol. 16 (2) , 131-135
The effect of patient shield position on gonad dose during lumbar spine radiography
- 31 May 2010
- Published by Elsevier in Radiography
- Vol. 16 (2) , 131-135
The effect of patient shield position on gonad dose during lumbar spine radiography
- 1 April 2008
- Published by Elsevier in Academic Radiology
- Vol. 15 (4) , 472-476
The Impact of Acoustic Noise Found Within Clinical Departments on Radiology Performance
- 1 April 2008
- Published by Elsevier in Academic Radiology
- Vol. 15 (4) , 472-476
The Impact of Acoustic Noise Found Within Clinical Departments on Radiology Performance
- 8 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6515, 65150M-65150
Ambient lighting: setting international standards for the viewing of softcopy chest images
Clinical radiological judgments are increasingly being made on softcopy LCD monitors. These monitors are found throughout the hospital environment in radiological reading rooms, outpatient clinics and wards. This means that ambient lighting where clinical judgments from images are made can vary widely. Inappropriate ambient lighting has several deleterious effects: monitor reflections reduce contrast; veiling glare adds brightness; dynamic range and detectability of low contrast objects is limited. Radiological images displayed on LCDs are more sensitive to the impact of inappropriate ambient lighting and with these devices problems described above are often more evident. The current work aims to provide data on optimum ambient lighting, based on lesions within chest images. The data provided may be used for the establishment of workable ambient lighting standards. Ambient lighting at 30cms from the monitor was set at 480 Lux (office lighting) 100 Lux (WHO recommendations), 40 Lux and
- 8 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6515, 65150M-65150
Ambient lighting: setting international standards for the viewing of softcopy chest images
Clinical radiological judgments are increasingly being made on softcopy LCD monitors. These monitors are found throughout the hospital environment in radiological reading rooms, outpatient clinics and wards. This means that ambient lighting where clinical judgments from images are made can vary widely. Inappropriate ambient lighting has several deleterious effects: monitor reflections reduce contrast; veiling glare adds brightness; dynamic range and detectability of low contrast objects is limited. Radiological images displayed on LCDs are more sensitive to the impact of inappropriate ambient lighting and with these devices problems described above are often more evident. The current work aims to provide data on optimum ambient lighting, based on lesions within chest images. The data provided may be used for the establishment of workable ambient lighting standards. Ambient lighting at 30cms from the monitor was set at 480 Lux (office lighting) 100 Lux (WHO recommendations), 40 Lux and
- 17 June 2006
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 121 (4) , 391-394
Radio-protective aprons during radiological examinations of the thorax: an optimum strategy
The current work investigates the most effective type/position of aprons for postero-anterior (PA) and lateral projections of the chest. Two apron-types were investigated: ‘Mavig’ half apron and Amray light plus' wrap-around apron. The half apron was positioned at the X-ray tube or image receptor side of an anthropomorphic phantom for PA and lateral projections. Radiation dose at positions corresponding to ovaries, uterus and testes was measured with thermoluminescent dosemeters. The wrap-around apron offers a higher level of protection for PA and lateral projections compared with the half apron, regardless of where the latter was positioned, with dose reductions of up to 88% compared with no apron. For the PA position, the half apron should be positioned in a gender-specific way, facing the X-ray tube for females and the image receptor for males. With all apron types/positions, gonadal dose is still clearly evident, from internal scatter, emphasising the importance of other protective practices such as collimation.
- 17 June 2006
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 121 (4) , 391-394
Radio-protective aprons during radiological examinations of the thorax: an optimum strategy
The current work investigates the most effective type/position of aprons for postero-anterior (PA) and lateral projections of the chest. Two apron-types were investigated: ‘Mavig’ half apron and Amray light plus' wrap-around apron. The half apron was positioned at the X-ray tube or image receptor side of an anthropomorphic phantom for PA and lateral projections. Radiation dose at positions corresponding to ovaries, uterus and testes was measured with thermoluminescent dosemeters. The wrap-around apron offers a higher level of protection for PA and lateral projections compared with the half apron, regardless of where the latter was positioned, with dose reductions of up to 88% compared with no apron. For the PA position, the half apron should be positioned in a gender-specific way, facing the X-ray tube for females and the image receptor for males. With all apron types/positions, gonadal dose is still clearly evident, from internal scatter, emphasising the importance of other protective practices such as collimation.
- 24 March 2005
- Published by Springer Nature in European Radiology
- Vol. 15 (7) , 1477-1484
Protective aprons in imaging departments: manufacturer stated lead equivalence values require validation
The composition of protective aprons worn by X-ray personnel to shield against secondary radiation is changing. Lead is being replaced by either lead-free or composite (lead with other high atomic numbered elements) materials. These newer aprons are categorised by manufacturers in terms of lead equivalent values, but it is unclear how these stated values compare with actual lead equivalent values. In this work, the actual lead equivalence of 41 protective aprons from four manufacturers, all specified as having 0.25 mm lead equivalence, were investigated with transmission experiments at 70 and 100 kVp. All aprons were in current use. The aprons were screened for defects, and age, weight and design was recorded along with details of associated quality assurance (QA). Out of the 41 protective aprons examined for actual lead equivalence, 73% were outside tolerance levels, with actual levels in some aprons demonstrating less than half of the nominal values. The lack of compatibility between actual and nominal lead equivalent values was demonstrated by aprons from three of the four manufacturers investigated. The area of the defects found on screening of the protective aprons were within recommendations. The results highlight the need for acceptancy and ongoing checks of protective aprons to ensure that radiation exposure of imaging personnel is kept to a minimum.
- 24 March 2005
- Published by Springer Nature in European Radiology
- Vol. 15 (7) , 1477-1484
Protective aprons in imaging departments: manufacturer stated lead equivalence values require validation
The composition of protective aprons worn by X-ray personnel to shield against secondary radiation is changing. Lead is being replaced by either lead-free or composite (lead with other high atomic numbered elements) materials. These newer aprons are categorised by manufacturers in terms of lead equivalent values, but it is unclear how these stated values compare with actual lead equivalent values. In this work, the actual lead equivalence of 41 protective aprons from four manufacturers, all specified as having 0.25 mm lead equivalence, were investigated with transmission experiments at 70 and 100 kVp. All aprons were in current use. The aprons were screened for defects, and age, weight and design was recorded along with details of associated quality assurance (QA). Out of the 41 protective aprons examined for actual lead equivalence, 73% were outside tolerance levels, with actual levels in some aprons demonstrating less than half of the nominal values. The lack of compatibility between actual and nominal lead equivalent values was demonstrated by aprons from three of the four manufacturers investigated. The area of the defects found on screening of the protective aprons were within recommendations. The results highlight the need for acceptancy and ongoing checks of protective aprons to ensure that radiation exposure of imaging personnel is kept to a minimum.
- 1 February 2004
- Published by Elsevier in Radiography
- Vol. 10 (1) , 15-21
Gonad protection for the antero-posterior projection of the pelvis in diagnostic radiography in Dublin hospitals
- 1 February 2004
- Published by Elsevier in Radiography
- Vol. 10 (1) , 15-21
Gonad protection for the antero-posterior projection of the pelvis in diagnostic radiography in Dublin hospitals
- 1 February 2004
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 108 (3) , 263-268
Increasing film-focus distance (ffd) reduces radiation dose for x-ray examinations
Increasing film-focus distance (FFD) from the traditional 100 cm has been shown to be an effective method of reducing dose whilst maintaining image quality. In particular, previous work increasing the FFD from 100 to 130 cm for lumbar spine examinations demonstrated an effective dose reduction of 44%. Objective. The current study continues on from this work by investigating the dose-reducing efficacy of this FFD change for pelvis X-ray examinations. Materials and methods. Dose measurements at 100 and 130 cm using thermoluminescent dosemeters were undertaken using an anthropomorphic phantom and patients. Image quality was assessed using CEC anatomical criteria and psychophysical tests. Results. The results showed that increasing the FFD results in a reduction in effective dose of 33%, with no change in image quality. The data provided in this and previous studies demonstrate the need for rapid implementation of this simple cost-effective procedure across imaging departments, leading to an important reduction in collective dose. Conclusion. The CEC recommendation of using 115 cm FFD for a number of procedures, although useful compared with 100 cm, undervalues by a factor between 2 and 3 the potential of this dose-reducing tool.
- 1 February 2004
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 108 (3) , 263-268
Increasing film-focus distance (ffd) reduces radiation dose for x-ray examinations
Increasing film-focus distance (FFD) from the traditional 100 cm has been shown to be an effective method of reducing dose whilst maintaining image quality. In particular, previous work increasing the FFD from 100 to 130 cm for lumbar spine examinations demonstrated an effective dose reduction of 44%. Objective. The current study continues on from this work by investigating the dose-reducing efficacy of this FFD change for pelvis X-ray examinations. Materials and methods. Dose measurements at 100 and 130 cm using thermoluminescent dosemeters were undertaken using an anthropomorphic phantom and patients. Image quality was assessed using CEC anatomical criteria and psychophysical tests. Results. The results showed that increasing the FFD results in a reduction in effective dose of 33%, with no change in image quality. The data provided in this and previous studies demonstrate the need for rapid implementation of this simple cost-effective procedure across imaging departments, leading to an important reduction in collective dose. Conclusion. The CEC recommendation of using 115 cm FFD for a number of procedures, although useful compared with 100 cm, undervalues by a factor between 2 and 3 the potential of this dose-reducing tool.
- 15 January 2004
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 108 (2) , 123-132
Dose-reducing strategies in combination offers substantial potential benefits to females requiring X-ray examination
This work, using an adult anthropomorphic phantom, aimed to establish an optimised technique for ladies of child-bearing age undergoing antero-posterior (AP) pelvis and AP and lateral lumbar spine examinations. Phase one of the work involved introducing the following dose-reducing measures individually: increased kVp, increased focus-film distances, a carbon fibre cassette, a faster film/screen combination. The second phase established an optimised technique based on a combination of the parameters listed above. Radiation dose was measured using thermoluminescent dosimeters and image quality was evaluated using anatomical criteria. All dose-reducing methods were compared with a standard technique, currently being used in a Dublin hospital. The results demonstrated that the optimised procedure reduced effective dose by 77, 62 and 66% for AP pelvis and AP and lateral lumbar spine respectively (p < 0.05) compared with the standard technique, with no significant changes in image quality. Dose-reducing measures used in combination offer substantial potential for optimisation of radiological procedures.
- 15 January 2004
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 108 (2) , 123-132
Dose-reducing strategies in combination offers substantial potential benefits to females requiring X-ray examination
This work, using an adult anthropomorphic phantom, aimed to establish an optimised technique for ladies of child-bearing age undergoing antero-posterior (AP) pelvis and AP and lateral lumbar spine examinations. Phase one of the work involved introducing the following dose-reducing measures individually: increased kVp, increased focus-film distances, a carbon fibre cassette, a faster film/screen combination. The second phase established an optimised technique based on a combination of the parameters listed above. Radiation dose was measured using thermoluminescent dosimeters and image quality was evaluated using anatomical criteria. All dose-reducing methods were compared with a standard technique, currently being used in a Dublin hospital. The results demonstrated that the optimised procedure reduced effective dose by 77, 62 and 66% for AP pelvis and AP and lateral lumbar spine respectively (p < 0.05) compared with the standard technique, with no significant changes in image quality. Dose-reducing measures used in combination offer substantial potential for optimisation of radiological procedures.
- 1 August 2003
- Published by Springer Nature in European Radiology
- Vol. 13 (8) , 1992-1999
Do CEC guidelines under-utilise the full potential of increasing kVp as a dose-reducing tool?
Increasing beam energies are well established as a radiation dose-reducing tool in diagnostic radiology. This has led to useful recommendations by the Commission of European Communities (CEC) for appropriate kVp values to be employed for a variety of examinations. The current work tests the hypothesis that kVp levels above those recommended by the CEC will result in reduced patient dose while still producing images of acceptable quality. This study explored the effect of a range of kVp levels within and above CEC recommendations for lumbar spine radiology. A phantom investigation facilitated selection of appropriate kVp levels for a patient study (n=59): 81 kVp (CEC) and 96 kVp (non-CEC) for the AP projection and 90 kVp (CEC) and 102 kVp (non-CEC) for the lateral projection. Entrance surface and effective dose were calculated and image quality quantified using CEC image criteria and images of a detail contrast test tool. Data analysis demonstrated significant reduction in effective radiation dose for AP (29.9%) and lateral (24.6%) when a kVp value above the CEC range was employed compared with a kVp recommended by the CEC. Although significant reductions in total image quality of 18.3% and 10.1% for the antero-posterior and lateral projections, respectively, were noted, all patient images produced with all kVp values were considered acceptable by each member of the evaluative panel with all image criteria receiving a score of 2 (out of 3) or better. The psychophysical tests revealed minor non-significant reductions in visualisation scores. The current study demonstrated that kVp values outside the CEC recommended range offer reductions in dose while producing acceptable images. Practitioners should be guided, rather than constrained, by the CEC recommendations on good radiographic technique. The need for further work exploring the effect of higher energies on visualisation of subtle pathological lesions has been identified.
- 1 August 2003
- Published by Springer Nature in European Radiology
- Vol. 13 (8) , 1992-1999
Do CEC guidelines under-utilise the full potential of increasing kVp as a dose-reducing tool?
Increasing beam energies are well established as a radiation dose-reducing tool in diagnostic radiology. This has led to useful recommendations by the Commission of European Communities (CEC) for appropriate kVp values to be employed for a variety of examinations. The current work tests the hypothesis that kVp levels above those recommended by the CEC will result in reduced patient dose while still producing images of acceptable quality. This study explored the effect of a range of kVp levels within and above CEC recommendations for lumbar spine radiology. A phantom investigation facilitated selection of appropriate kVp levels for a patient study (n=59): 81 kVp (CEC) and 96 kVp (non-CEC) for the AP projection and 90 kVp (CEC) and 102 kVp (non-CEC) for the lateral projection. Entrance surface and effective dose were calculated and image quality quantified using CEC image criteria and images of a detail contrast test tool. Data analysis demonstrated significant reduction in effective radiation dose for AP (29.9%) and lateral (24.6%) when a kVp value above the CEC range was employed compared with a kVp recommended by the CEC. Although significant reductions in total image quality of 18.3% and 10.1% for the antero-posterior and lateral projections, respectively, were noted, all patient images produced with all kVp values were considered acceptable by each member of the evaluative panel with all image criteria receiving a score of 2 (out of 3) or better. The psychophysical tests revealed minor non-significant reductions in visualisation scores. The current study demonstrated that kVp values outside the CEC recommended range offer reductions in dose while producing acceptable images. Practitioners should be guided, rather than constrained, by the CEC recommendations on good radiographic technique. The need for further work exploring the effect of higher energies on visualisation of subtle pathological lesions has been identified.