Gábor Székely
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gábor Székely has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Matthias Harders
ETH Zurich
4 shared publications - Philippe Cattin
ETH Zurich
4 shared publications - Christian Gerber
Balgrist Campus Research and Development Center, Zürich, Switzerland
2 shared publications - Hatem Alkadhi
Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
2 shared publications - Lazaros Vlachopoulos
Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
2 shared publications - Philipp Fürnstahl
Research in Orthopedic Computer Science, University Hospital Balgrist, University of Zurich, Zurich, Switzerland
2 shared publications
Latest Publications
- 1 January 2018
- Published by Elsevier in Medical Image Analysis
- Vol. 43, 142-156
A scale-space curvature matching algorithm for the reconstruction of complex proximal humeral fractures
- 1 January 2018
- Published by Elsevier in Medical Image Analysis
- Vol. 43, 142-156
A scale-space curvature matching algorithm for the reconstruction of complex proximal humeral fractures
- 1 August 2017
- Published by Elsevier in Journal of Computational Physics
- Vol. 343, 271-299
Fully implicit methodology for the dynamics of biomembranes and capillary interfaces by combining the level set and Newton methods
- 1 August 2017
- Published by Elsevier in Journal of Computational Physics
- Vol. 343, 271-299
Fully implicit methodology for the dynamics of biomembranes and capillary interfaces by combining the level set and Newton methods
- 1 October 2016
- Published by Elsevier in Medical Image Analysis
- Vol. 33, 79-83
Image guidance in orthopaedics and traumatology: A historical perspective
- 1 October 2016
- Published by Elsevier in Medical Image Analysis
- Vol. 33, 79-83
Image guidance in orthopaedics and traumatology: A historical perspective
- 1 July 2016
- Published by Elsevier in Medical Image Analysis
- Vol. 31, 88-97
Regression forest-based automatic estimation of the articular margin plane for shoulder prosthesis planning
- 1 July 2016
- Published by Elsevier in Medical Image Analysis
- Vol. 31, 88-97
Regression forest-based automatic estimation of the articular margin plane for shoulder prosthesis planning
- 1 December 2015
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 41 (12) , 3044-3062
Estimation of Large-Scale Organ Motion in B-Mode Ultrasound Image Sequences: A Survey
- 1 December 2015
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 41 (12) , 3044-3062
Estimation of Large-Scale Organ Motion in B-Mode Ultrasound Image Sequences: A Survey
- 18 November 2015
- Published by Springer Nature
- p. 215-222
Simultaneous Denoising and Registration for Accurate Cardiac Diffusion Tensor Reconstruction from MRI
- 18 November 2015
- Published by Springer Nature
- p. 215-222
Simultaneous Denoising and Registration for Accurate Cardiac Diffusion Tensor Reconstruction from MRI
- Open Access
- 31 July 2015
- Published by Springer Nature in Journal of Therapeutic Ultrasound
- Vol. 3 (1) , 1-18
Full-wave acoustic and thermal modeling of transcranial ultrasound propagation and investigation of skull-induced aberration correction techniques: a feasibility study
Transcranial focused ultrasound (tcFUS) is an attractive noninvasive modality for neurosurgical interventions. The presence of the skull, however, compromises the efficiency of tcFUS therapy, as its heterogeneous nature and acoustic characteristics induce significant distortion of the acoustic energy deposition, focal shifts, and thermal gain decrease. Phased-array transducers allow for partial compensation of skull-induced aberrations by application of precalculated phase and amplitude corrections. An integrated numerical framework allowing for 3D full-wave, nonlinear acoustic and thermal simulations has been developed and applied to tcFUS. Simulations were performed to investigate the impact of skull aberrations, the possibility of extending the treatment envelope, and adverse secondary effects. The simulated setup comprised an idealized model of the ExAblate Neuro and a detailed MR-based anatomical head model. Four different approaches were employed to calculate aberration corrections (analytical calculation of the aberration corrections disregarding tissue heterogeneities; a semi-analytical ray-tracing approach compensating for the presence of the skull; two simulation-based time-reversal approaches with and without pressure amplitude corrections which account for the entire anatomy). These impact of these approaches on the pressure and temperature distributions were evaluated for 22 brain-targets While (semi-)analytical approaches failed to induced high pressure or ablative temperatures in any but the targets in the close vicinity of the geometric focus, simulation-based approaches indicate the possibility of considerably extending the treatment envelope (including targets below the transducer level and locations several centimeters off the geometric focus), generation of sharper foci, and increased targeting accuracy. While the prediction of achievable aberration correction appears to be unaffected by the detailed bone-structure, proper consideration of inhomogeneity is required to predict the pressure distribution for given steering parameters Simulation-based approaches to calculate aberration corrections may aid in the extension of the tcFUS treatment envelope as well as predict and avoid secondary effects (standing waves, skull heating). Due to their superior performance, simulationbased techniques may prove invaluable in the amelioration of skull-induced aberration effects in tcFUS therapy. The next steps are to investigate shear-wave-induced effects in order to reliably exclude secondary hot-spots, and to develop comprehensive uncertainty assessment and validation procedures.
- 31 July 2015
- Published by Springer Nature in Journal of Therapeutic Ultrasound
- Vol. 3 (1) , 1-18
Open AccessFull-wave acoustic and thermal modeling of transcranial ultrasound propagation and investigation of skull-induced aberration correction techniques: a feasibility study
Transcranial focused ultrasound (tcFUS) is an attractive noninvasive modality for neurosurgical interventions. The presence of the skull, however, compromises the efficiency of tcFUS therapy, as its heterogeneous nature and acoustic characteristics induce significant distortion of the acoustic energy deposition, focal shifts, and thermal gain decrease. Phased-array transducers allow for partial compensation of skull-induced aberrations by application of precalculated phase and amplitude corrections. An integrated numerical framework allowing for 3D full-wave, nonlinear acoustic and thermal simulations has been developed and applied to tcFUS. Simulations were performed to investigate the impact of skull aberrations, the possibility of extending the treatment envelope, and adverse secondary effects. The simulated setup comprised an idealized model of the ExAblate Neuro and a detailed MR-based anatomical head model. Four different approaches were employed to calculate aberration corrections (analytical calculation of the aberration corrections disregarding tissue heterogeneities; a semi-analytical ray-tracing approach compensating for the presence of the skull; two simulation-based time-reversal approaches with and without pressure amplitude corrections which account for the entire anatomy). These impact of these approaches on the pressure and temperature distributions were evaluated for 22 brain-targets While (semi-)analytical approaches failed to induced high pressure or ablative temperatures in any but the targets in the close vicinity of the geometric focus, simulation-based approaches indicate the possibility of considerably extending the treatment envelope (including targets below the transducer level and locations several centimeters off the geometric focus), generation of sharper foci, and increased targeting accuracy. While the prediction of achievable aberration correction appears to be unaffected by the detailed bone-structure, proper consideration of inhomogeneity is required to predict the pressure distribution for given steering parameters Simulation-based approaches to calculate aberration corrections may aid in the extension of the tcFUS treatment envelope as well as predict and avoid secondary effects (standing waves, skull heating). Due to their superior performance, simulationbased techniques may prove invaluable in the amelioration of skull-induced aberration effects in tcFUS therapy. The next steps are to investigate shear-wave-induced effects in order to reliably exclude secondary hot-spots, and to develop comprehensive uncertainty assessment and validation procedures.
- 25 November 2013
- Published by Springer Nature
- p. 63-77
Computational Support for Intraoperative Imaging and IGT
- 25 November 2013
- Published by Springer Nature
- p. 63-77
Computational Support for Intraoperative Imaging and IGT
- 25 November 2013
- Published by Springer Nature
- p. 421-438
Intraoperative Guidance Using 3D Scene Reconstruction from Endoscopic Images
- 25 November 2013
- Published by Springer Nature
- p. 421-438
Intraoperative Guidance Using 3D Scene Reconstruction from Endoscopic Images
- 12 January 2011
- Published by Springer Nature in Skeletal Radiology
- Vol. 40 (5) , 595-601
X-ray absorption-based imaging and its limitations in the differentiation of ancient mummified tissue
Objectives Differentiation of ancient tissues is of key importance in the study of paleopathology and in the evolution of human diseases. Currently, the number of imaging facilities for the non-destructive discrimination of dehydrated tissue is limited, and little is known about the role that emerging imaging technologies may play in this field. Therefore, this study investigated the feasibility and quality of dual-energy computed tomography (DECT) for the discrimination of dry and brittle soft tissue. Moreover, this study explored the relationship between morphological changes and image contrast in ancient tissue by using X-ray micro-tomography (micro-CT). Materials and Methods An Egyptian mummy head and neck was scanned with DECT at tube voltage/current of 140 kVp/27 mAs (tube A) and 100 kVp/120 mAs (tube B). The CT attenuation was determined by regions of interest (ROI) measurements of hard and soft tissue of the mummy skull. Finally, two samples from the posterior neck were dissected to acquire micro-CT images of shrunken dehydrated tissue. Results Dual-energy CT images demonstrated the high contrast resolution of surface structures from mummy skull. Bone density changes in the posterior skull base as well as soft-tissue alterations of the eyes and tongue were assessed. Micro-CT scans allowed the identification of morphological changes and the discrimination of muscle tissue from inorganic material in samples taken from the neck. Conclusions Significant attenuation differences (p < 0.0007) were observed within 12 of the 15 ancient tissue groups and organic materials using DECT. We detected a correlation between X-ray scattering and image contrast reduction in dehydrated tissue with micro-CT imaging.
- 12 January 2011
- Published by Springer Nature in Skeletal Radiology
- Vol. 40 (5) , 595-601
X-ray absorption-based imaging and its limitations in the differentiation of ancient mummified tissue
Objectives Differentiation of ancient tissues is of key importance in the study of paleopathology and in the evolution of human diseases. Currently, the number of imaging facilities for the non-destructive discrimination of dehydrated tissue is limited, and little is known about the role that emerging imaging technologies may play in this field. Therefore, this study investigated the feasibility and quality of dual-energy computed tomography (DECT) for the discrimination of dry and brittle soft tissue. Moreover, this study explored the relationship between morphological changes and image contrast in ancient tissue by using X-ray micro-tomography (micro-CT). Materials and Methods An Egyptian mummy head and neck was scanned with DECT at tube voltage/current of 140 kVp/27 mAs (tube A) and 100 kVp/120 mAs (tube B). The CT attenuation was determined by regions of interest (ROI) measurements of hard and soft tissue of the mummy skull. Finally, two samples from the posterior neck were dissected to acquire micro-CT images of shrunken dehydrated tissue. Results Dual-energy CT images demonstrated the high contrast resolution of surface structures from mummy skull. Bone density changes in the posterior skull base as well as soft-tissue alterations of the eyes and tongue were assessed. Micro-CT scans allowed the identification of morphological changes and the discrimination of muscle tissue from inorganic material in samples taken from the neck. Conclusions Significant attenuation differences (p < 0.0007) were observed within 12 of the 15 ancient tissue groups and organic materials using DECT. We detected a correlation between X-ray scattering and image contrast reduction in dehydrated tissue with micro-CT imaging.