Takeyoshi Dohi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Takeyoshi Dohi has a total of 110 co-authors. Here are the top co-authors by number of shared publications:
- Ichiro Sakuma
The University of Tokyo
16 shared publications Ken Masamune
12 shared publicationsMakoto Hashizume
11 shared publications- Etsuko Kobayashi
The University of Tokyo
7 shared publications Nobuhiko Hata
7 shared publications- Nobuhiko Hata
National Center for Image Guided Therapy, Department of Radiology, Brigham and Women’s Hospital and Harvard Medical School, 75 Francis Street, Boston, MA 02115, USA
7 shared publications
Latest Publications
- Open Access
- 1 January 2016
- Published by The Japan Society of Computer Aided Surgery in Journal of Japan Society of Computer Aided Surgery
- Vol. 18 (1) , 5-18
Three-way Conversation : Founding of Computer Aided Surgery
- 1 January 2016
- Published by The Japan Society of Computer Aided Surgery in Journal of Japan Society of Computer Aided Surgery
- Vol. 18 (1) , 5-18
Open AccessThree-way Conversation : Founding of Computer Aided Surgery
- 1 January 2013
- Published by The Japan Society of Computer Aided Surgery in Journal of Japan Society of Computer Aided Surgery
- Vol. 15 (1) , 5-10
Needle Insertion Robotic Systems for Image-guided Stereotactic Neurosurgery
In 1991, we have developed a needle insertion robotic system for CT-guided stereotactic neurosurgery. The system, based on existing stereotactic frame, had six DOF of movement with minimum size to fit a CT gantry.Safety issue was carefully considered: by cutting off the power supply, all axes were held rigidly to avoid unexpected motion. A phantom study using X-ray CT showed that the overall position error was 1.0mm. This system was followed by MRI-compatible version.This paper presents the history of this system and briefly reviews other stereotactic robots.
- 1 January 2013
- Published by The Japan Society of Computer Aided Surgery in Journal of Japan Society of Computer Aided Surgery
- Vol. 15 (1) , 5-10
Needle Insertion Robotic Systems for Image-guided Stereotactic Neurosurgery
In 1991, we have developed a needle insertion robotic system for CT-guided stereotactic neurosurgery. The system, based on existing stereotactic frame, had six DOF of movement with minimum size to fit a CT gantry.Safety issue was carefully considered: by cutting off the power supply, all axes were held rigidly to avoid unexpected motion. A phantom study using X-ray CT showed that the overall position error was 1.0mm. This system was followed by MRI-compatible version.This paper presents the history of this system and briefly reviews other stereotactic robots.
- 1 January 2009
- Published by Japan Society of Mechanical Engineers in The proceedings of the JSME annual meeting
- Vol. 2009.7, 259-260
J1102-1-6 Evaluation of influence on MRI scans to electromagnetic waves for Open type MRI
MRI is now utilized not only for diagnosis but also for intraoperative surgical treatment. Many MR Compatible robotic and mechatronics systems were developed by in order to treat within MRI. However, there is a problem that the leak electromagnetic waves from the developed instrument affect on MR images. Therefore, we evaluated the influence on MRI scans to electromagnetic waves for Open type MRI. As the result, in a resonant frequency band, electromagnetic waves will not affect MRI scans by less than -71.85 dBμA/m around the MR coil. We think that this evaluation result is effective for developing novel MR Compatible robotic and mechatronic systems for acquiring MR images.
- 1 January 2009
- Published by Japan Society of Mechanical Engineers in The proceedings of the JSME annual meeting
- Vol. 2009.7, 259-260
J1102-1-6 Evaluation of influence on MRI scans to electromagnetic waves for Open type MRI
MRI is now utilized not only for diagnosis but also for intraoperative surgical treatment. Many MR Compatible robotic and mechatronics systems were developed by in order to treat within MRI. However, there is a problem that the leak electromagnetic waves from the developed instrument affect on MR images. Therefore, we evaluated the influence on MRI scans to electromagnetic waves for Open type MRI. As the result, in a resonant frequency band, electromagnetic waves will not affect MRI scans by less than -71.85 dBμA/m around the MR coil. We think that this evaluation result is effective for developing novel MR Compatible robotic and mechatronic systems for acquiring MR images.
- Open Access
- 1 January 2007
- Published by The Japan Society of Computer Aided Surgery in Journal of Japan Society of Computer Aided Surgery
- Vol. 9 (2) , 91-101
Development of a Miniature 2-DOFs Bending Manipulator with Bipolar Coagulator
We developed a miniature 2-DOFs bending manipulator of 5-mm diameter for laparoscopic surgery. Bending directions of the mechanism are perpendicular and the mechanisms are controllable respectively. A new wire-connected linkage-driven bending mechanism is built in the manipulator to drive rotate joints for 2-DOFs motion. This manipulator has a central channel of 1.3-mm diameter to drive a pair of blades with electrodes as the tip-side bipolar-coagulator. Surgeons control the manipulator with a grip-type interface in one hand. In mechanical performance evaluations, bending angle was maximum 153.9degrees (from -71.6 to 82.3 degrees) with positioning reproducibility of maximum 0.7mm. About generated force, holding force of bending mechanism was more than 1.82N, and grasping force by a pair of blades as maximum 3.70N. In vivo experiment using a pig (38kg, male) with laparoscopy, we evaluated whether the manipulator performed as a suitable bipolar coagulator for practical clinical use. We were able to coagulate living tissues and occlude blood vessels on the mesenterium completely. In conclusion, our new bending mechanism is useful for miniaturization of the laparoscopic manipulator with the simple structure and high mechanical performance.
- 1 January 2007
- Published by The Japan Society of Computer Aided Surgery in Journal of Japan Society of Computer Aided Surgery
- Vol. 9 (2) , 91-101
Open AccessDevelopment of a Miniature 2-DOFs Bending Manipulator with Bipolar Coagulator
We developed a miniature 2-DOFs bending manipulator of 5-mm diameter for laparoscopic surgery. Bending directions of the mechanism are perpendicular and the mechanisms are controllable respectively. A new wire-connected linkage-driven bending mechanism is built in the manipulator to drive rotate joints for 2-DOFs motion. This manipulator has a central channel of 1.3-mm diameter to drive a pair of blades with electrodes as the tip-side bipolar-coagulator. Surgeons control the manipulator with a grip-type interface in one hand. In mechanical performance evaluations, bending angle was maximum 153.9degrees (from -71.6 to 82.3 degrees) with positioning reproducibility of maximum 0.7mm. About generated force, holding force of bending mechanism was more than 1.82N, and grasping force by a pair of blades as maximum 3.70N. In vivo experiment using a pig (38kg, male) with laparoscopy, we evaluated whether the manipulator performed as a suitable bipolar coagulator for practical clinical use. We were able to coagulate living tissues and occlude blood vessels on the mesenterium completely. In conclusion, our new bending mechanism is useful for miniaturization of the laparoscopic manipulator with the simple structure and high mechanical performance.
- 1 January 2007
- Published by The Japan Society of Computer Aided Surgery in Journal of Japan Society of Computer Aided Surgery
- Vol. 9 (2) , 103-111
Compact Manipulator System for Guiding Needle with Real-time Navigation Based on MR Images
To support needle placements, we developed a compact surgical manipulator system using MRI (magnetic resonance imaging)-guided navigation. The manipulator is designed for use in 430-mm high spaces and the strong magnetic field of an open-MRI. The design uses ultrasonic motors, which are located 750mm away from joints of the manipulator at the center of the MRI. The manipulator can position a puncture needle on the body and pivot around the insertion point to orient the needle. Navigation is performed using MR images of the needle held by the manipulator. While watching these navigational images, the surgeon can maneuver the manipulator to line up the needle trajectory with target, and then manually insert the needle into the target.The effectiveness of the system was verified with an in-vivo experiment in the MRI (AIRIS-II: Hitachi Medical Corp.). No noticeable deformation in the MR images was observed, even when the manipulator was in motion. Furthermore, the MR images always showed the needle that was moved by the manipulator. This indicates that the manipulator system is accurate enough for needle placement.
- 1 January 2007
- Published by The Japan Society of Computer Aided Surgery in Journal of Japan Society of Computer Aided Surgery
- Vol. 9 (2) , 103-111
Compact Manipulator System for Guiding Needle with Real-time Navigation Based on MR Images
To support needle placements, we developed a compact surgical manipulator system using MRI (magnetic resonance imaging)-guided navigation. The manipulator is designed for use in 430-mm high spaces and the strong magnetic field of an open-MRI. The design uses ultrasonic motors, which are located 750mm away from joints of the manipulator at the center of the MRI. The manipulator can position a puncture needle on the body and pivot around the insertion point to orient the needle. Navigation is performed using MR images of the needle held by the manipulator. While watching these navigational images, the surgeon can maneuver the manipulator to line up the needle trajectory with target, and then manually insert the needle into the target.The effectiveness of the system was verified with an in-vivo experiment in the MRI (AIRIS-II: Hitachi Medical Corp.). No noticeable deformation in the MR images was observed, even when the manipulator was in motion. Furthermore, the MR images always showed the needle that was moved by the manipulator. This indicates that the manipulator system is accurate enough for needle placement.
- 1 January 2007
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 19 (Supplement) , 189
Development of a new patch for fetal myelomeningocele repair
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 1 January 2007
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 19 (Supplement) , 189
Development of a new patch for fetal myelomeningocele repair
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 1 January 2006
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2006, _2A1-A15_1
2A1-A15 The development of 7DOF Manipulator Driving Surgical Tools for the Compact Surgical Support System with MR-compatibility
The concept and specification of a compact surgical manipulator for intervention support systems in MRI (Magnetic Resonance Imager) was studied with authorities. Based on this specification, the design/prototype production was performed about a compact surgical manipulator, surgical tools, and a control unit. In consideration of spatial interference with the receiving coil or a patient body surface in the gap of opened type MRI, modularization, and number of the necessary degree of freedom, we developed seven-degree-of-freedom compact surgical manipulators driving surgical tools. This manipulator can work in space of 430[mm] high. In addition, the surgical tool is exchangeable, and has three degree of freedom at the tip that the manipulator can drive without using a wire. We evaluated MR compatibility of the manipulator, and confirmed that no problem occurred in both sensors and a movement range.
- 1 January 2006
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2006, _2A1-A15_1
2A1-A15 The development of 7DOF Manipulator Driving Surgical Tools for the Compact Surgical Support System with MR-compatibility
The concept and specification of a compact surgical manipulator for intervention support systems in MRI (Magnetic Resonance Imager) was studied with authorities. Based on this specification, the design/prototype production was performed about a compact surgical manipulator, surgical tools, and a control unit. In consideration of spatial interference with the receiving coil or a patient body surface in the gap of opened type MRI, modularization, and number of the necessary degree of freedom, we developed seven-degree-of-freedom compact surgical manipulators driving surgical tools. This manipulator can work in space of 430[mm] high. In addition, the surgical tool is exchangeable, and has three degree of freedom at the tip that the manipulator can drive without using a wire. We evaluated MR compatibility of the manipulator, and confirmed that no problem occurred in both sensors and a movement range.
- 1 January 2006
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2006, _2A1-A31_1
2A1-A31 Biomechanical Leg Modeling for Motion Control in a Femur Fracture Reduction Robotic System
We have been developing a surgical robotic system for femur fracture reduction. In surgeries, it is significant to position fractured bone fragments accurately for strong fracture fixation and short hospitalizations. Loading the foot of a fractured leg is generally employed as an adequate operation for repositioning the fragments because this operation does not have the risks of bone breakdown, which is often caused in skeletal traction. However, a human leg, which contains joints such as a knee joint and an ankle joint, does not move rigidly against the controlled motion of the foot. It makes bone position control difficult in our robotic system. To control the fragment positions precisely, we propose a new method, which is a feedback control and uses the biomechanical model to estimate the leg bones position by measuring the load on the foot. In this paper, the feasibility of proposed method is evaluated and discussed.
- 1 January 2006
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2006, _2A1-A31_1
2A1-A31 Biomechanical Leg Modeling for Motion Control in a Femur Fracture Reduction Robotic System
We have been developing a surgical robotic system for femur fracture reduction. In surgeries, it is significant to position fractured bone fragments accurately for strong fracture fixation and short hospitalizations. Loading the foot of a fractured leg is generally employed as an adequate operation for repositioning the fragments because this operation does not have the risks of bone breakdown, which is often caused in skeletal traction. However, a human leg, which contains joints such as a knee joint and an ankle joint, does not move rigidly against the controlled motion of the foot. It makes bone position control difficult in our robotic system. To control the fragment positions precisely, we propose a new method, which is a feedback control and uses the biomechanical model to estimate the leg bones position by measuring the load on the foot. In this paper, the feasibility of proposed method is evaluated and discussed.
- 1 January 2006
- Published by The Japan Society of Computer Aided Surgery in Journal of Japan Society of Computer Aided Surgery
- Vol. 8 (2) , 97-102
Improvement of Flexible Viewpoint Laparoscope with Wedge Prisms and Evaluation of Image Quality
We have developed a novel robotic laparoscope for laparoscopic surgery to move the view point optically with double wedge prisms instead of moving the laparoscope itself. In this study, based on the problems that a previous invivo experiment pinpointed with the previous prototype, we redesigned a new prototype to widen the angle of view and thin the diameter of the laparoscope. The tube's diameter is thinned down into 18mm including a light source to fit in a commercial trocar. The prptotype has a view moving angle of ±19.2°, a view moving speed of 7.7°/s and a view moving error of 0.55±0.62mm at a distance of 100mm. It has an enough viewing area in the abdominal cavity and has a suffisient speed in the actual use. For the image quality, it maintains a high quality of image resolution, less distortion aberration and chromatic aberration. We received high evaluation marks for the image quality in the in-vivo experiment.
- 1 January 2006
- Published by The Japan Society of Computer Aided Surgery in Journal of Japan Society of Computer Aided Surgery
- Vol. 8 (2) , 97-102
Improvement of Flexible Viewpoint Laparoscope with Wedge Prisms and Evaluation of Image Quality
We have developed a novel robotic laparoscope for laparoscopic surgery to move the view point optically with double wedge prisms instead of moving the laparoscope itself. In this study, based on the problems that a previous invivo experiment pinpointed with the previous prototype, we redesigned a new prototype to widen the angle of view and thin the diameter of the laparoscope. The tube's diameter is thinned down into 18mm including a light source to fit in a commercial trocar. The prptotype has a view moving angle of ±19.2°, a view moving speed of 7.7°/s and a view moving error of 0.55±0.62mm at a distance of 100mm. It has an enough viewing area in the abdominal cavity and has a suffisient speed in the actual use. For the image quality, it maintains a high quality of image resolution, less distortion aberration and chromatic aberration. We received high evaluation marks for the image quality in the in-vivo experiment.
- 1 January 2006
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 18 (Supplement) , 77
3-D Stereoscopic Visualization of Medical Image for MRI-guided Surgery
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 1 January 2006
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 18 (Supplement) , 77
3-D Stereoscopic Visualization of Medical Image for MRI-guided Surgery
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies