NPNeal W. Pollock

Neal W. Pollock

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Neal W. Pollock has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 September 2015
      • Vol. 45  (3) , 209

    Re: Don't dive cold when you don't have to.

    by Neal W Pollock

    The letter by Clarke et al unfortunately misrepresents the work at the US Navy Experimental Diving Unit (NEDU) to which it refers, and delivers a confused picture of the physiological impact of thermal status on decompression stress. A series of earlier reports outline the importance of thermal status. Being warm during a dive results in higher post-dive Doppler bubble scores. Hot water suits are associated with a higher rate of decompression sickness (DCS) than passively insulated drysuits. Post-dive cooling can prolong the risk window for developing symptoms of skin bends.The NEDU chamber study provided an elegant design to further assess the impact of thermal stress. Dives to 37 msw (120 fsw) were divided into descent/bottom and ascent/stop phases, prolonging the latter so that bottom times could be increased if results allowed without compromising the experimental structure. The water temperature was held at either 36 °C (97 °F; 'warm') or 27 °C (80 °F; 'cold'). The 'warm/cold' exposure, with a bottom time of 30 minutes, yielded a DCS rate of 22% (7/32 subject-exposures). The 'cold/warm' bottom time was increased to 70 minutes and still yielded a DCS rate of only 1.3% (2/158). Even if the effects are exaggerated by the prolonged ascent/stop phase, the dramatic results demand serious attention. Contrary to the claim made by Clarke et al in their letter, the high temperature employed in the NEDU study could almost certainly be maintained at the skin by a number of active heating garments available to the diving public. Hot water suits are not required for the effect; and the 'cold' study temperature (better described as 'cool') is clearly well within the range experienced by divers. The statement by Clarke et al that "the Navy uses their extensive mathematical expertise to select the one dive profile that, in their estimation, is the most likely to identify a difference in decompression risk..." is frankly baffling. Use of a single dive depth in no way invalidates the relevance to other dive profiles. Similarly, it is not reasonable to characterize skin temperatures lower than those produced in the study as "venturing into the unknown" and thereby invalidating the results. Scientific method does encourage the confirmation of findings. This goal, however, does not diminish the value of singular, well-designed studies. The NEDU study is certainly one of these, most valuable in reminding divers that factors beyond the pressure-time profile will affect decompression risk. Divers must have adequate thermal protection to function effectively (physically and cognitively) throughout a dive. However, excessive warming during the descent/bottom phase increases inert gas uptake and can compromise decompression safety. Practically, while it may be optimal for divers to be cool or cold during the descent/bottom phase, it is prudent to recommend a thermoneutral range and avoidance of any excessive warming. Being cool during the ascent/stop phase inhibits inert gas elimination and can compromise safety but sudden warming must be constrained to avoid reducing the gas solubility of superficial tissues that could promote localized bubble formation and symptoms of skin bends. Active heating systems are attractive, but they have the potential to create the worst decompression stress condition; excessive heating during the descent/bottom phase and cooling during the ascent/stop phase if they fail part way through a dive. The risk is still elevated, though, if the systems work throughout a dive. Gerth et al were able to increase the bottom time to 70 minutes for both the 'coldwarm' and 'warm-warm' conditions, but the rate of DCS was significantly lower for the 'cold-warm' condition (see above). This lesson is relevant to any diving exposure. Ultimately, divers need to be aware of the potential impact of thermal status. Thermal protection should preserve clear thinking and physical performance, but excessive manipulation should be avoided. For many, passive systems will provide adequate and appropriate protection. For those who need or choose active warming systems, thoughtful use is vital. Further research is required to quantify the hazards and be able to incorporate thermal status into decompression algorithms in a meaningful way.

    • 1 March 2014
      • Vol. 44  (1) , 2-3

    Ultrasonic detection of decompression-induced bubbles.

    by Neal W Pollock, Ron Y Nishi


  • Influence of Repeated Daily Diving on Decompression Stress

    by J. Zanchi, M. Ljubkovic, P. J. Denoble, Z. Dujic, S. Ranapurwala, N. W. Pollock

    Acclimatization (an adaptive change in response to repeated environmental exposure) to diving could reduce decompression stress. A decrease in post-dive circulating venous gas emboli (VGE or bubbles) would represent positive acclimatization. The purpose of this study was to determine whether four days of daily diving alter post-dive bubble grades. 16 male divers performed identical no-decompression air dives on 4 consecutive days to 18 meters of sea water for 47 min bottom times. VGE monitoring was performed with transthoracic echocardiography every 20 min for 120 min post-dive. Completion of identical daily dives resulted in progressively decreasing odds (or logit risk) of having relatively higher grade bubbles on consecutive days. The odds on Day 4 were half that of Day 1 (OR 0.50, 95% CI: 0.34, 0.73). The odds ratio for a >III bubble grade on Day 4 was 0.37 (95% CI: 0.20, 0.70) when compared to Day 1. The current study indicates that repetitive daily diving may reduce bubble formation, representing a positive (protective) acclimatization to diving. Further work is required to evaluate the impact of additional days of diving and multiple dive days and to determine if the effect is sufficient to alter the absolute risk of decompression sickness.


  • Chemical Oxygen Generation: Evaluation of the Green Dot Systems, Inc Portable, Nonpressurized emOx Device

    by Neal W. Pollock, Michael J. Natoli

    Objective: To evaluate the performance of the emOx emergency powdered oxygen portable nonpressurized delivery system. This device produces oxygen through chemical reaction and is marketed for emergency first aid use until professional medical assistance is available. Methods: Seven unmanned trials were conducted under standard laboratory conditions. Measures included oxygen flow, reaction canister external wall temperature, delivered gas temperature, and delivered gas relative humidity. Results: The mean oxygen flow was 1.75 ± 1.58 L · min−1 (mean ± SD) with a total yield of 40.4 ± 2.6 L. Oxygen flow increased slowly and with substantial variability between reactant groups, exceeding 2.0 L · min−1 after 15.7 ± 6.4 minutes of operation. Oxygen flow briefly peaked at 5.93 ± 0.56 L · min−1 at 17.8 ± 7.9 minutes before rapidly falling to zero. The mean oxygen fraction was 0.81 ± 0.28, exceeding 0.96 in 10.7 ± 2.9 minutes. The reaction canister external wall temperature reached 54.7 ± 7.4°C. Delivered gas temperature varied little from ambient. Delivered gas relative humidity surpassed 75% in 8 ± 3 minutes and 90% in 15 ± 5 minutes of operation. Conclusions: A readily available, high concentration oxygen supply could have utility to manage many conditions in advance of the arrival of professional emergency medical services (EMS). Unfortunately, the highly variable activation time and low average oxygen flow rate make the rapid deployment value of the emOx equivocal. The limited total oxygen yield makes it inappropriate for conditions demanding significant oxygen resources. Advancement in oxygen concentrator systems likely holds far more promise than powdered chemical oxygen generation for first aid and emergency medical applications.


    • 1 December 2008
      • Vol. 38  (4) , 182-8

    Scuba injury death rate among insured DAN members.

    by Petar J Denoble, Neal W Pollock, Panchabi Vaithiyanathan, James L Caruso, Joel A Dovenbarger, Richard D Vann

    We calculated the annual rates of diving-related deaths among DAN-insured members in the period from 2000 to 2006 and investigated the effects of age and sex on death rate by logistic regression. We determined relative risks for divers < 50 and ≥ 50 years of age for drowning, arterial gas embolism, and cardiac incidents, the three most common disabling injuries associated with diving death. There were 1,141,367 insured member-years and 187 diving-related deaths. Males made up 64% of the members. Individuals ≥ 50 years of age constituted 31% of the fatalities. Insured mean age increased from 40 ± 12 to 43 ± 13 years over the seven-year study period. Annual fatality rates varied between 12.1 and 22.9 (average 16.4, 95% confidence intervals 14.2, 18.9) per 100,000 persons insured. The relative risk for male divers in their thirties was six times greater than the risk for female divers in the same age range. Fatality rates increased with age for both sexes, but the higher relative risk for males progressively decreased until the rates became similar for both sexes after age 60. Death associated with cardiac incidents was 12.9 times more likely in divers ≥ 50 years of age. We recommend that older divers adjust their participation in diving according to health status and physical fitness, maintain fitness with regular exercise, and abstain from diving in conditions likely to require unaccustomed physical activity.


    • 1 June 2008
      • Vol. 38  (2) , 79-86

    Breath-hold diving: performance and safety.

    by Neal W Pollock

    Breath-hold diving was probably first conducted shortly after humans ventured into the water realm. Early efforts likely centred on exploration, hunting and gathering. The fundamentals of breath-hold diving have not changed since these earliest efforts but the performance records have undergone an almost unbelievable evolution. Single breath-hold durations (inspiring air) of 9:15 min:s and 8:00 min:s and maximal vertical transits of 214 metres' sea water (msw) and 160 msw for males and females, respectively, are daunting. Competitive performance requires genetic predisposition, motivation and training in both fundamentals and a variety of advanced techniques. The record of safety within the competitive arena is impressive but care must be taken to ensure that the appropriate practices and procedures are communicated to all levels of enthusiast. Current performance records, strategies to optimize performance, and recommendations for safe breath-hold activity are presented.


  • Performance Characteristics of the Second-Generation Remote Emergency Medical Oxygen Closed-Circuit Rebreather☆

    by Neal W. Pollock, Michael J. Natoli

    Closed-circuit oxygen rebreathers may provide high concentrations of oxygen at extremely low flow rates appropriate for field use with limited oxygen supplies. The performance of the preproduction, second-generation remote emergency medical oxygen (REMO(2)) system developed for Divers Alert Network was evaluated. The unidirectional circuit was made up of a solid, prepackaged CO(2) scrubber canister (984 +/- 14 [SD] g scrubber mass), standard 22-mm-inside-diameter anesthesia circuit hoses, 5-L breathing bag, 5-cm H(2)O positive end-expiratory pressure valve, and oronasal mask. Oxygen flow, inspired oxygen, expired CO(2), peak inspired and expired mask pressures, time to reach scrubber canister saturation or "breakthrough" (postscrubber CO(2) concentration reaching 3.8 mm Hg), and subject tolerance were measured under standard laboratory conditions. Six trials were completed using healthy volunteers (94.7 +/- 19.6 kg). Five of the 6 completed trials did not reach breakthrough at the planned trial limit of 8 hours. Mean average oxygen flow rate was 1.00 +/- 0.17 L x min(-1). Mean peak inspired and expired mask pressures were -5.0 +/- 1.9 and 6.5 +/- 1.9 cm H(2)O, respectively. Subjects generally reported good tolerance to circuit breathing. The second-generation REMO(2) was well tolerated by healthy subjects during 8-hour laboratory evaluation trials. The device provided high mean inspired oxygen fractions at low mean oxygen flow rates, relatively modest mean maximal inspired and expired pressures, and excellent scrubber canister duration. Further evaluation of field performance with a patient population is warranted.


    • 1 November 2003
      • Vol. 74  (11) , 1163-8

    Risk of decompression sickness during exposure to high cabin altitude after diving.

    by Neal W Pollock, Michael J Natoli, Wayne A Gerth, Edward D Thalmann, Richard D Vann

    Postdive altitude exposure increases the risk of decompression sickness (DCS). Certain training and operational situations may require U.S. Special Operations Forces (SOF) personnel to conduct high altitude parachute operations after diving. Problematically, the minimum safe preflight surface intervals (PFSI) between diving and high altitude flying are not known. There were 102 healthy, male volunteers (34 +/- 10 [mean +/- SD] yr of age, 84.5 +/- 13.8 kg weight, 26.2 +/- 4.2 kg x m(-2) BMI) who completed simulated 60 fsw (feet of seawater)/60 min air dives preceding simulated 3-h flights at 25,000 ft to study DCS risk as a function of PFSI. Subjects were dry and at rest throughout. Oxygen was breathed for 30 min before and during flight in accordance with SOF protocols. Subjects were monitored for clinical signs of DCS and for venous gas emboli (VGE) using precordial Doppler ultrasound. DCS incidence was compared with Chi-squared; VGE onset time and time to maximum grade with one-way ANOVA (significance at p < 0.05). Three cases of DCS occurred in 155 subject-exposures: 1/35 and 0/24 in 2 and 3 h flight-only controls, respectively; 0/23, 1/37, and 1/36 for 24, 18, and 12 h dive-PFSI-flight profiles, respectively. DCS risk did not differ between profiles (chi2 [4] = 1.33; crit = 9.49). VGE were observed in 19% of flights. Neither VGE onset time nor time to max grade differed between profiles (82 +/- 38 min [p = 0.88] and 100 +/- 40 min [p = 0.68], respectively). Increased DCS risk was not detected as a result of dry, resting 60 fsw/60 min air dives conducted 24-12 h before a resting, 3-h oxygen-breathing 25,000 ft flight (following 30 min oxygen prebreathe). The current SOF-prescribed minimum PFSI of 24 h may be unnecessarily conservative.


  • Evaluation of the System O2 Inc Portable Nonpressurized Oxygen Delivery System

    by Neal W. Pollock, Gene W. Hobbs

    To evaluate the performance of the System O2 portable non-pressurized delivery system (SysO2). This device produces oxygen through chemical reaction and might have utility for emergency/field use. Performance was evaluated with 10 unmanned trials conducted under standard laboratory conditions. Measures included oxygen flow (mean and peak), total oxygen yield, and system weight-indexed yield. Oxygen flow peaked at 5.74 +/- 0.28 L x min(-1) (mean +/- SD) at 16.9 +/- 1.5 minutes before rapidly falling to zero. Mean flow was 2.98 +/- 1.52 L x min(-1) with a total yield of 62.9 +/- 6.6 L. Mean oxygen fraction was 0.96 +/- 0.15. The weight per unit of oxygen is substantially higher than for commercially available pressurized cylinders; e.g., 47.7 vs. 10.2 g x L(-1) for the small 246 L M9 cylinder. Given the limited flow rate and supply duration, we believe the SysO2 system does not offer significant advantage over the available pressurized oxygen systems as a source for emergency oxygen.