Carsten V. Dalchow
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Carsten V. Dalchow has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Alfred L. Weber
Department of Radiology, Massachusetts Eye and Ear Infirmary, Boston, MA
1 shared publication- Anja A Dünne
Department of Otolaryngology, Head and Neck Surgery, Philipps University of Marburg, Germany
1 shared publication - Benedikt J. Folz
Department of Otolaryngology and Head and Neck Surgery, Philipps University of Marburg, Deutschhausstrasse 3, 35037 Marburg, Germany
1 shared publication H Jungclas
1 shared publicationJochen A Werner
1 shared publicationJochen A. Werner
Department of Otolaryngology, Head and Neck Surgery, Philipps University Marburg, Deutschhausstr. 3, 35037 Marburg, Germany
1 shared publication
Latest Publications
- 1 February 2006
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 186 (2) , 416-423
Digital Volume Tomography: Radiologic Examinations of the Temporal Bone
OBJECTIVE. We evaluated the clinical applicability and the value of digital volume tomography for visualization of the lateral skull base using temporal bone specimens. MATERIALS AND METHODS. Twelve temporal bone specimens were used to evaluate digital volume tomography on the lateral skull base. Aside from the initial examination of the temporal bones, radiologic control examinations were performed after insertion of titanium, gold, and platinum middle-ear implants and a cochlear implant. RESULTS. With high-resolution and almost artifact-free visualization of alloplastic middle-ear implants of titanium, gold, or platinum, it was possible to define the smallest bone structures or position of the prosthesis with high precision. Furthermore, the examination proved that digital volume tomography is useful in assessing the normal position of a cochlear implant. CONCLUSION. Digital volume tomography expands the application of diagnostic possibilities in the lateral skull base. Therefore, we believe improved preoperative diagnosis can be achieved along with more accurate planning of the surgical procedure. Digital volume tomography delivers a small radiation dose and a high resolution coupled with a low purchase price for the equipment.
- 1 February 2006
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 186 (2) , 416-423
Digital Volume Tomography: Radiologic Examinations of the Temporal Bone
OBJECTIVE. We evaluated the clinical applicability and the value of digital volume tomography for visualization of the lateral skull base using temporal bone specimens. MATERIALS AND METHODS. Twelve temporal bone specimens were used to evaluate digital volume tomography on the lateral skull base. Aside from the initial examination of the temporal bones, radiologic control examinations were performed after insertion of titanium, gold, and platinum middle-ear implants and a cochlear implant. RESULTS. With high-resolution and almost artifact-free visualization of alloplastic middle-ear implants of titanium, gold, or platinum, it was possible to define the smallest bone structures or position of the prosthesis with high precision. Furthermore, the examination proved that digital volume tomography is useful in assessing the normal position of a cochlear implant. CONCLUSION. Digital volume tomography expands the application of diagnostic possibilities in the lateral skull base. Therefore, we believe improved preoperative diagnosis can be achieved along with more accurate planning of the surgical procedure. Digital volume tomography delivers a small radiation dose and a high resolution coupled with a low purchase price for the equipment.
- 1 January 2006
- Vol. 60 (3) , 283-90
In-vitro investigations evaluating the detection spectrum of cervical lymph nodes via handheld gamma probe.
Currently the significance of the sentinel node (SN) biopsy also for head and neck cancer is discussed intensively. Based on the complex anatomic structures of this region with a low distance between primary and sentinel node as well as approximately 300 lymph nodes an intensive discussion of the methodical basis of sentinel node detection seems to be essential. Thus it was the aim of the present study to examine the detection spectrum of a gamma probe for identification of cervical lymph nodes using an in vitro model to describe and objectify the particularities of measurement existing in the head and neck region. In an in vitro model the detection spectrum of a gamma probe is examined in 29 different series of measurements (variation of the specimen filled with 99m pertechnetat regarding activity, position, collimator distance, tissue sheath). The presented in vitro model reflects the clinical problem of narrow intranodal activity of neighbouring lymph nodes and reveals a direct relation between the number of radiation sources and their isolated evidence. Using muscle tissue with a thickness of 0.4 cm, two two-rowed radiation sources, the more powerful is placed 1.5 cm behind the other specimen, with a lateral difference of 3 cm, can be resolved only with a maximal detector distance of 1 cm. Not the difference of the tissue but the thickness of the tissue is decisive for detection. Especially for pharyngeal and laryngeal lymph nodes a transcutaneous measurement reflecting the exact localisation of hot nodes in the area of the deep jugular lymph nodes is not possible with increasing tissue thickness. The described results require a critical discussion of the different detection techniques varying among the different working groups of this field.
- 1 January 2006
- Vol. 60 (3) , 283-90
In-vitro investigations evaluating the detection spectrum of cervical lymph nodes via handheld gamma probe.
Currently the significance of the sentinel node (SN) biopsy also for head and neck cancer is discussed intensively. Based on the complex anatomic structures of this region with a low distance between primary and sentinel node as well as approximately 300 lymph nodes an intensive discussion of the methodical basis of sentinel node detection seems to be essential. Thus it was the aim of the present study to examine the detection spectrum of a gamma probe for identification of cervical lymph nodes using an in vitro model to describe and objectify the particularities of measurement existing in the head and neck region. In an in vitro model the detection spectrum of a gamma probe is examined in 29 different series of measurements (variation of the specimen filled with 99m pertechnetat regarding activity, position, collimator distance, tissue sheath). The presented in vitro model reflects the clinical problem of narrow intranodal activity of neighbouring lymph nodes and reveals a direct relation between the number of radiation sources and their isolated evidence. Using muscle tissue with a thickness of 0.4 cm, two two-rowed radiation sources, the more powerful is placed 1.5 cm behind the other specimen, with a lateral difference of 3 cm, can be resolved only with a maximal detector distance of 1 cm. Not the difference of the tissue but the thickness of the tissue is decisive for detection. Especially for pharyngeal and laryngeal lymph nodes a transcutaneous measurement reflecting the exact localisation of hot nodes in the area of the deep jugular lymph nodes is not possible with increasing tissue thickness. The described results require a critical discussion of the different detection techniques varying among the different working groups of this field.
- 19 September 2005
- Published by Georg Thieme Verlag KG in Journal of Neurological Surgery Part B: Skull Base
- Vol. 15 (S 2) , B-6-116
Digital Volume Tomography—Value of a New Radiographic Technique for Examinations of the Lateral Skull Base
Introduction: Digital volume tomography (DVT) is an extension of panoramic tomography. With this diagnostic technique, characterized by high resolution, minimal section thickness of 0.125 mm, and three-dimensional display, small pathological processes can be well visualized. Material and Methods: The digital volume tomograph Accu-I-tomo (Morita, Kyoto, Japan) was consecutively used to examine patients with a history of an otologic disease. A three-dimensional dataset of a cylinder with a diameter of 3 × 4 cm was obtained in one 360-degree rotation with 80 kV and 8 mA adjustments. The images of the temporal bone region were analyzed with special software (3DX Integrated Information System Version 1.52, Morita, Kyoto, Japan). The data were displayed after reconstruction on a PC monitor in three planes oriented vertically to each other with minimal intersection distance and a minimal section thickness of 0.125 mm. The section angle, section thickness, and intersectional distance were modified to selectively depict individual structures. Results: Clinical investigations showed smallest bony modifications of the middle ear with the DVT. Small lesions, such as erosion of the ossicles, semicircular canals, cochlea, internal auditory canal or apex of the temporal bone, can be visualized. The three-dimensional presentation allows good spatial orientation and precise planning of a surgical approach. Conclusions: DVT expands the application of diagnostic possibilities in the lateral skull base. Therefore we believe improved preoperative diagnosis can be achieved along with more accurate planning of the surgical procedure. Compared with conventional CT, DVT delivers a smaller radiation dose and a higher resolution coupled with lower purchase price of the equipment.
- 19 September 2005
- Published by Georg Thieme Verlag KG in Journal of Neurological Surgery Part B: Skull Base
- Vol. 15 (S 2) , B-6-116
Digital Volume Tomography—Value of a New Radiographic Technique for Examinations of the Lateral Skull Base
Introduction: Digital volume tomography (DVT) is an extension of panoramic tomography. With this diagnostic technique, characterized by high resolution, minimal section thickness of 0.125 mm, and three-dimensional display, small pathological processes can be well visualized. Material and Methods: The digital volume tomograph Accu-I-tomo (Morita, Kyoto, Japan) was consecutively used to examine patients with a history of an otologic disease. A three-dimensional dataset of a cylinder with a diameter of 3 × 4 cm was obtained in one 360-degree rotation with 80 kV and 8 mA adjustments. The images of the temporal bone region were analyzed with special software (3DX Integrated Information System Version 1.52, Morita, Kyoto, Japan). The data were displayed after reconstruction on a PC monitor in three planes oriented vertically to each other with minimal intersection distance and a minimal section thickness of 0.125 mm. The section angle, section thickness, and intersectional distance were modified to selectively depict individual structures. Results: Clinical investigations showed smallest bony modifications of the middle ear with the DVT. Small lesions, such as erosion of the ossicles, semicircular canals, cochlea, internal auditory canal or apex of the temporal bone, can be visualized. The three-dimensional presentation allows good spatial orientation and precise planning of a surgical approach. Conclusions: DVT expands the application of diagnostic possibilities in the lateral skull base. Therefore we believe improved preoperative diagnosis can be achieved along with more accurate planning of the surgical procedure. Compared with conventional CT, DVT delivers a smaller radiation dose and a higher resolution coupled with lower purchase price of the equipment.
- 1 July 2005
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 26 (4) , 678-679
A New Instrument for Minimal Access Surgery in Cochlear Implantation
Evaluation of usefulness and benefits of a new hand-held retractor for minimal invasive technique in cochlear implantation. Tertiary medical center. Fourteen consecutive patients (age: 1-83; 4 = female and 10 = male) received a cochlear implant in minimal invasive technique using the new hand-held retractor. Standardized operation procedure in minimal invasive technique for cochlear implantation. A short retroauricular incision is used to perform the mastoidectomy with posterior tympanotomy and cochleostomy. The hand-held retractor allows drilling of the bony well for the receiver-stimulator package under direct vision from an anterior position of the surgeon. The sub-periosteal pocket is performed while maintaining continuous suction of irrigating fluids with no further assistance needed. With the new retractor, up to 70% of time to create the bony well is saved compared to previously used instrumentation. The retractor might be further useful in different fields of surgery where the operating field needs to be visualized with the integrated suction and light-device under protection of the surrounding tissue.
- 1 July 2005
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 26 (4) , 678-679
A New Instrument for Minimal Access Surgery in Cochlear Implantation
Evaluation of usefulness and benefits of a new hand-held retractor for minimal invasive technique in cochlear implantation. Tertiary medical center. Fourteen consecutive patients (age: 1-83; 4 = female and 10 = male) received a cochlear implant in minimal invasive technique using the new hand-held retractor. Standardized operation procedure in minimal invasive technique for cochlear implantation. A short retroauricular incision is used to perform the mastoidectomy with posterior tympanotomy and cochleostomy. The hand-held retractor allows drilling of the bony well for the receiver-stimulator package under direct vision from an anterior position of the surgeon. The sub-periosteal pocket is performed while maintaining continuous suction of irrigating fluids with no further assistance needed. With the new retractor, up to 70% of time to create the bony well is saved compared to previously used instrumentation. The retractor might be further useful in different fields of surgery where the operating field needs to be visualized with the integrated suction and light-device under protection of the surrounding tissue.