Rinze A. Tange
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Rinze A. Tange has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Wilko Grolman
Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht, The Netherlands
7 shared publications - Wouter A. Dreschler
Amsterdam UMC
3 shared publications A J De Bruijn
Department of Otolaryngology-Head and Neck Surgery, Academic Medical Center, University of Amsterdam, The Netherlands
1 shared publicationA. Maat
1 shared publicationA.J.G de Bruijn
1 shared publicationBart Carelsen
1 shared publication
Latest Publications
- 1 February 2007
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 28 (2) , 195-198
Migration of the Ball Electrode After Cochlear Implantation
To review the postoperative radiographic investigations of patients implanted with a cochlear implant. Retrospective case series. Thirty-nine patients (22-77 yrs old) implanted for sensorineural deafness in the cochlear implants program of the Academic Medical Center of Amsterdam. Cochlear implantation with Cochlear Nucleus 24 Contour and Cochlear Nucleus Freedom (Cochlear Corp., Lane Cove, New South Wales, Australia) implant. This retrospective analysis of the postoperative computed tomographic scans showed that, in a large number of the implantations, the external ball electrode of the cochlear implant migrated from the insertion place toward the magnet of the receiver/stimulator unit of the implant. It seems that this migration of the external ball electrode does not influence the function of the cochlear implant and the result of the hearing rehabilitation in the short term. Because of the magnetic field of the receiver/stimulator unit of the cochlear implant and the magnet of the external transmitting coil of the speech processor, it seems to be possible that the extracochlear ball electrode can migrate in the space between the temporal bone and the temporal muscle during the postoperative healing phase. The importance of our observation is still not clear.
- 1 February 2007
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 28 (2) , 195-198
Migration of the Ball Electrode After Cochlear Implantation
To review the postoperative radiographic investigations of patients implanted with a cochlear implant. Retrospective case series. Thirty-nine patients (22-77 yrs old) implanted for sensorineural deafness in the cochlear implants program of the Academic Medical Center of Amsterdam. Cochlear implantation with Cochlear Nucleus 24 Contour and Cochlear Nucleus Freedom (Cochlear Corp., Lane Cove, New South Wales, Australia) implant. This retrospective analysis of the postoperative computed tomographic scans showed that, in a large number of the implantations, the external ball electrode of the cochlear implant migrated from the insertion place toward the magnet of the receiver/stimulator unit of the implant. It seems that this migration of the external ball electrode does not influence the function of the cochlear implant and the result of the hearing rehabilitation in the short term. Because of the magnetic field of the receiver/stimulator unit of the cochlear implant and the magnet of the external transmitting coil of the speech processor, it seems to be possible that the extracochlear ball electrode can migrate in the space between the temporal bone and the temporal muscle during the postoperative healing phase. The importance of our observation is still not clear.
- 23 May 2006
- Published by Wiley in Clinical Otolaryngology
- Vol. 31 (3) , 230-232
How we do it: Reinsertion of the stylet into the nucleus contour cochlear implant to facilitate second insertion. A helpful technique salvaging the cochlear implant device
- 23 May 2006
- Published by Wiley in Clinical Otolaryngology
- Vol. 31 (3) , 230-232
How we do it: Reinsertion of the stylet into the nucleus contour cochlear implant to facilitate second insertion. A helpful technique salvaging the cochlear implant device
- 1 January 2006
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 126 (6) , 650-652
Intracochlear misdirected implantation of a cochlear implant
This paper discusses a rare complication of an intracochlear misdirection of the electrode of a cochlear implant in a 55-year-old male. The patient received a cochlear implant using the mastoid-saving surgical approach. Intraoperative measurements showed impedance and NRT reactions suggesting a reasonable function of the inner ear and the implant. Postoperatively our patient suffered from passing vertigo. Postoperative CT scans revealed a misdirection implantation of the cochlear implant into the vestibular part of the inner ear. A deformed implant was removed and a reimplantation was successfully performed after enlarging and reshaping the cochleostomy. Our patient now enjoys all the benefits of an optimal functioning cochlear implant. Intracochlear misdirection of the electrode can occur even when intraoperative measurements seem to be normal. When a patient suffers from unexplained vertigo after cochlear implantation with a poor function of the implant a misdirection of the active electrode must be considered. New high resolution peroperative three-dimensional imaging techniques can probably help to avoid such insertion failures.
- 1 January 2006
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 126 (6) , 650-652
Intracochlear misdirected implantation of a cochlear implant
This paper discusses a rare complication of an intracochlear misdirection of the electrode of a cochlear implant in a 55-year-old male. The patient received a cochlear implant using the mastoid-saving surgical approach. Intraoperative measurements showed impedance and NRT reactions suggesting a reasonable function of the inner ear and the implant. Postoperatively our patient suffered from passing vertigo. Postoperative CT scans revealed a misdirection implantation of the cochlear implant into the vestibular part of the inner ear. A deformed implant was removed and a reimplantation was successfully performed after enlarging and reshaping the cochleostomy. Our patient now enjoys all the benefits of an optimal functioning cochlear implant. Intracochlear misdirection of the electrode can occur even when intraoperative measurements seem to be normal. When a patient suffers from unexplained vertigo after cochlear implantation with a poor function of the implant a misdirection of the active electrode must be considered. New high resolution peroperative three-dimensional imaging techniques can probably help to avoid such insertion failures.
- 1 March 2004
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 25 (2) , 102-105
Gold and Titanium in the Oval Window: A Comparison of Two Metal Stapes Prostheses
The objective of this study was to evaluate the hearing results of stapes surgery with 2 different full metal stapes prostheses. Retrospective analyses were carried out on the pre- and postoperative hearing results obtained after primary stapedotomy with 2 different prostheses. We studied 106 patients with otosclerosis treated by stapes surgery. Fifty-three patients had a stapedotomy with a gold piston and 53 patients received a titanium piston after stapedotomy. The results were compared according to mean audiometric parameters. Furthermore, the individual audiologic results were demonstrated with the Amsterdam Hearing Evaluations Plot (AHEP). This method is a visual presentation of the hearing result for each operated ear. These AHEPs showed that the heavier gold piston (shaft Ø 0.4 mm and weight 10192.0 μg) gives more overclosure gain (28.3%) than the lightweight (shaft Ø 0.4 mm and weight 2541.0 μg) titanium piston (9.4% cases of overclosure). Because of the different properties of the 2 pistons (gold very malleable, titanium rather stiff), a choice can be made for different anatomic or pathologic situations in the operated middle ear. The “overclosure effect” of the gold piston is higher compared with the titanium piston.
- 1 March 2004
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 25 (2) , 102-105
Gold and Titanium in the Oval Window: A Comparison of Two Metal Stapes Prostheses
The objective of this study was to evaluate the hearing results of stapes surgery with 2 different full metal stapes prostheses. Retrospective analyses were carried out on the pre- and postoperative hearing results obtained after primary stapedotomy with 2 different prostheses. We studied 106 patients with otosclerosis treated by stapes surgery. Fifty-three patients had a stapedotomy with a gold piston and 53 patients received a titanium piston after stapedotomy. The results were compared according to mean audiometric parameters. Furthermore, the individual audiologic results were demonstrated with the Amsterdam Hearing Evaluations Plot (AHEP). This method is a visual presentation of the hearing result for each operated ear. These AHEPs showed that the heavier gold piston (shaft Ø 0.4 mm and weight 10192.0 μg) gives more overclosure gain (28.3%) than the lightweight (shaft Ø 0.4 mm and weight 2541.0 μg) titanium piston (9.4% cases of overclosure). Because of the different properties of the 2 pistons (gold very malleable, titanium rather stiff), a choice can be made for different anatomic or pathologic situations in the operated middle ear. The “overclosure effect” of the gold piston is higher compared with the titanium piston.
- 1 January 2002
- Published by Elsevier in Auris Nasus Larynx
- Vol. 29 (1) , 7-10
Reparative granuloma seen in cases of gold piston implantation after stapes surgery for otosclerosis
- 1 January 2002
- Published by Elsevier in Auris Nasus Larynx
- Vol. 29 (1) , 7-10
Reparative granuloma seen in cases of gold piston implantation after stapes surgery for otosclerosis
- 1 April 2000
- Published by Elsevier in Auris Nasus Larynx
- Vol. 27 (2) , 113-116
The prevalence of allergy in young children with an acquired cholesteatoma
- 1 April 2000
- Published by Elsevier in Auris Nasus Larynx
- Vol. 27 (2) , 113-116
The prevalence of allergy in young children with an acquired cholesteatoma
- 1 September 1999
- Vol. 20 (5) , 573-80
Comparison of stapes prostheses: a retrospective analysis of individual audiometric results obtained after stapedotomy by implantation of a gold and a teflon piston.
Evaluation of hearing results after implantation of a Teflon piston (type Causse; Xomed Surgical Products, Jacksonville, FL) and of a pure gold piston (K-piston; Heinz Kurz GmbH Medizintechnik, Dusslingen, Germany), both with a shaft diameter of 0.4 mm in cases of otosclerosis requiring stapedotomy. An important difference between both prostheses is the difference in mass: the gold piston is three times heavier than the Teflon piston. Retrospective analyses were carried out of the presurgery and postsurgery audiologic results obtained after primary stapedotomy by implantation of 62 Teflon pistons and 66 gold pistons. The results were compared according to mean values of several audiometric parameters. Furthermore, individual audiometric results have been evaluated with the "Amsterdam Hearing Evaluation Plots" (AHEPs) as a method for visual presentation of hearing results from each operated ear. With this method, "unsuccessfully" and "successfully" inserted prostheses can be recognized easily and a more realistic comparison between prostheses is possible. It was found that in the overall group the heavier gold prosthesis gives a significantly larger gain in air-conductive hearing at 2 kHz (p < 0.05) and in the speech frequency range 0.5 to 2 kHz (p < 0.05). There were no significant intergroup differences with regard to change in bone-conduction and air-bone gaps. Analysis of the hearing results of the subgroup that included only the "successfully" implanted prostheses according to the criteria of the AHEPs had mainly consequences for improvement of air-conduction thresholds: none of the intergroup differences were statistically significant. For a fair comparison between prostheses, it is necessary to take only the prostheses into account that are inserted properly and that are functioning under normal conditions with regard to transmission of sound vibrations. After analysis of the hearing results of these "successfully" implanted prostheses, a trend was noticed that the heavier gold piston gives more gain in the low- and mid-frequency range and the light-weighted Teflon piston gives more gain in the high-frequency range, although none of the differences were significant.
- 1 September 1999
- Vol. 20 (5) , 573-80
Comparison of stapes prostheses: a retrospective analysis of individual audiometric results obtained after stapedotomy by implantation of a gold and a teflon piston.
Evaluation of hearing results after implantation of a Teflon piston (type Causse; Xomed Surgical Products, Jacksonville, FL) and of a pure gold piston (K-piston; Heinz Kurz GmbH Medizintechnik, Dusslingen, Germany), both with a shaft diameter of 0.4 mm in cases of otosclerosis requiring stapedotomy. An important difference between both prostheses is the difference in mass: the gold piston is three times heavier than the Teflon piston. Retrospective analyses were carried out of the presurgery and postsurgery audiologic results obtained after primary stapedotomy by implantation of 62 Teflon pistons and 66 gold pistons. The results were compared according to mean values of several audiometric parameters. Furthermore, individual audiometric results have been evaluated with the "Amsterdam Hearing Evaluation Plots" (AHEPs) as a method for visual presentation of hearing results from each operated ear. With this method, "unsuccessfully" and "successfully" inserted prostheses can be recognized easily and a more realistic comparison between prostheses is possible. It was found that in the overall group the heavier gold prosthesis gives a significantly larger gain in air-conductive hearing at 2 kHz (p < 0.05) and in the speech frequency range 0.5 to 2 kHz (p < 0.05). There were no significant intergroup differences with regard to change in bone-conduction and air-bone gaps. Analysis of the hearing results of the subgroup that included only the "successfully" implanted prostheses according to the criteria of the AHEPs had mainly consequences for improvement of air-conduction thresholds: none of the intergroup differences were statistically significant. For a fair comparison between prostheses, it is necessary to take only the prostheses into account that are inserted properly and that are functioning under normal conditions with regard to transmission of sound vibrations. After analysis of the hearing results of these "successfully" implanted prostheses, a trend was noticed that the heavier gold piston gives more gain in the low- and mid-frequency range and the light-weighted Teflon piston gives more gain in the high-frequency range, although none of the differences were significant.
- 1 September 1998
- Published by Elsevier in Auris Nasus Larynx
- Vol. 25 (3) , 249-253
Experience with a new pure gold piston in stapedotomy for cases of otosclerosis
- 1 September 1998
- Published by Elsevier in Auris Nasus Larynx
- Vol. 25 (3) , 249-253
Experience with a new pure gold piston in stapedotomy for cases of otosclerosis
- 1 April 1998
- Published by Wiley in Clinical Otolaryngology
- Vol. 23 (2) , 123-127
Bilateral stapedotomy in patients with otosclerosis: a disability-orientated evaluation of the benefit of second ear surgery
This study reports the evaluation of the results of 80 stapedotomies in patients with bilateral otosclerosis. All pre- and postoperative audiological data, together with all relevant information of the operations, were stored in a database and analysed retrospectively. A new approach has been developed in order to evaluate the benefit of second ear stapes surgery in a more disability-orientated way using the AMA-criteria in the Guides to the Evaluation of Permanent Impairment. In all patients the percentage of Binaural Hearing Impairment (BHI) and the percentage of Impairment of the Whole Person (IWP) were determined according to the AMA-criteria. In patients who had both operations at the Academic Medical Centre it was found after the first operation that there was an important decrease in the BHI-percentage (from 26% to 10%) as well as for the IWP-percentage (from 9% to 4%). In addition, the percentages dropped significantly after the second operation (from 11% to 7% and from 4% to 2%, respectively). During follow-up there were no serious complications. It is concluded that bilateral stapedotomy is a safe procedure with good results.
- 1 April 1998
- Published by Wiley in Clinical Otolaryngology
- Vol. 23 (2) , 123-127
Bilateral stapedotomy in patients with otosclerosis: a disability-orientated evaluation of the benefit of second ear surgery
This study reports the evaluation of the results of 80 stapedotomies in patients with bilateral otosclerosis. All pre- and postoperative audiological data, together with all relevant information of the operations, were stored in a database and analysed retrospectively. A new approach has been developed in order to evaluate the benefit of second ear stapes surgery in a more disability-orientated way using the AMA-criteria in the Guides to the Evaluation of Permanent Impairment. In all patients the percentage of Binaural Hearing Impairment (BHI) and the percentage of Impairment of the Whole Person (IWP) were determined according to the AMA-criteria. In patients who had both operations at the Academic Medical Centre it was found after the first operation that there was an important decrease in the BHI-percentage (from 26% to 10%) as well as for the IWP-percentage (from 9% to 4%). In addition, the percentages dropped significantly after the second operation (from 11% to 7% and from 4% to 2%, respectively). During follow-up there were no serious complications. It is concluded that bilateral stapedotomy is a safe procedure with good results.
- 11 March 1998
- Published by S. Karger AG in ORL
- Vol. 60 (2) , 78-84
Vascular Inner Ear Partition:A Concept for Some Forms of Sensorineural Hearing Loss and Vertigo
The results of a series of scanning electron microscopical studies were used to construct a model for the vascular pathways in the inner ear. Corrosion cast preparations of the vessels of the inner ear of the adult rat were used in this study. The inner ear is, like a hand, an end organ containing four sense organs (cochlea, saccule, utricle and the cristae ampullaris). All these specific inner ear structures have their own vascular supply. We have developed a blood flow diagram of the inner ear. This model was used for a classification of different types of ischemia in the inner ear and forms a concept for some forms of sensorineural hearing loss and vertigo. Four types of inner ear ischemia are proposed. In type I (a or b) of inner ear ischemia only the vessels of the cochlea are involved resulting in two types of hearing loss without vertigo. Type II is characterized by ischemia of a part of the cochlea and a part of the vestibular system. In type III (a or b) only the vestibular system is involved, while in type IV no blood circulation will be present in the inner ear resulting in total deafness and severe vertigo. Inner ear partition at ultramicroscopical level of these structures may be possible in the future and new imaging techniques will probably support the vascular schematic model presented in this study.
- 11 March 1998
- Published by S. Karger AG in ORL
- Vol. 60 (2) , 78-84
Vascular Inner Ear Partition:A Concept for Some Forms of Sensorineural Hearing Loss and Vertigo
The results of a series of scanning electron microscopical studies were used to construct a model for the vascular pathways in the inner ear. Corrosion cast preparations of the vessels of the inner ear of the adult rat were used in this study. The inner ear is, like a hand, an end organ containing four sense organs (cochlea, saccule, utricle and the cristae ampullaris). All these specific inner ear structures have their own vascular supply. We have developed a blood flow diagram of the inner ear. This model was used for a classification of different types of ischemia in the inner ear and forms a concept for some forms of sensorineural hearing loss and vertigo. Four types of inner ear ischemia are proposed. In type I (a or b) of inner ear ischemia only the vessels of the cochlea are involved resulting in two types of hearing loss without vertigo. Type II is characterized by ischemia of a part of the cochlea and a part of the vestibular system. In type III (a or b) only the vestibular system is involved, while in type IV no blood circulation will be present in the inner ear resulting in total deafness and severe vertigo. Inner ear partition at ultramicroscopical level of these structures may be possible in the future and new imaging techniques will probably support the vascular schematic model presented in this study.