Richard R. Heuser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Richard R. Heuser has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Amber Reese
Phoenix Heart Center, St. Joseph's Hospital and Medical Center, Phoenix, Arizona; and Sarver Heart Center, University of Arizona Health Science Center, Tuscon, Arizona
2 shared publicationsRomas J. Kirvaitis
Phoenix Heart Center, St. Joseph's Hospital and Medical Center, 500 W. Thomas Road, Phoenix, AZ 85013, USA
2 shared publicationsDavid T. Cragun
Division of Cardiology, University of Arizona, Phoenix, Arizona, USA
1 shared publicationKaren Waters
1 shared publicationLisa Kelly
1 shared publicationLisa M. Kelly
Phoenix Heart Center, St. Joseph's Hospital and Medical Center, Phoenix, Arizona; and Sarver Heart Center, University of Arizona Health Science Center, Tuscon, Arizona
1 shared publication
Latest Publications
- 29 January 2007
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 69 (4) , 532-540
Recanalization of chronic total peripheral arterial occlusions using optical coherent reflectometry with guided radiofrequency energy: A single center experience
Background: A forward-looking, fiberoptic guided device (Safe-Cross™ System, Intraluminal Therapeutics, Carlsbad, CA) has been used with guided radiofrequency energy to open chronic total occlusions (CTOs). This report describes the use of optical coherent reflectometry (OCR) system to assess safety and efficacy of opening CTOs in native peripheral arteries in the lower extremities: iliac, femoral, and popliteal. Methods: 18 CTOs in native peripheral arteries in 17 patients were treated with OCR after failed attempts with conventional wires (minimum 10 min of fluoroscopic time). When the CTO was crossed, routine angioplasty with or without stent was performed. Efficacy was defined as achievement of distal lumen position. Safety was defined as device success without perforation, dissection (≥Grade C), or distal embolization. The mean patient age was 72 years with 8 females and 10 males. Lesion characteristics included a mean vessel diameter of 5.8 mm and a mean lesion length of 22.4 cm. Ankle-brachial indices was ≤0.8 in all patients. Results: The OCR system was successful in crossing 100% of the CTOs in patients that failed conventional wire crossing, whereas clinical success occurred in 94% of these patients. Complications consisted of a single dissection ≥Grade C. No perforations or distal embolization occurred. Conclusions: The Safe-Cross OCR System is both efficacious and safe in the treatment of CTOs that failed crossing with conventional wires and indirect visualization of the intraluminal position by using OCR technology appears to minimize vessel trauma, dissection, perforation, and distal embolization.
- 29 January 2007
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 69 (4) , 532-540
Recanalization of chronic total peripheral arterial occlusions using optical coherent reflectometry with guided radiofrequency energy: A single center experience
Background: A forward-looking, fiberoptic guided device (Safe-Cross™ System, Intraluminal Therapeutics, Carlsbad, CA) has been used with guided radiofrequency energy to open chronic total occlusions (CTOs). This report describes the use of optical coherent reflectometry (OCR) system to assess safety and efficacy of opening CTOs in native peripheral arteries in the lower extremities: iliac, femoral, and popliteal. Methods: 18 CTOs in native peripheral arteries in 17 patients were treated with OCR after failed attempts with conventional wires (minimum 10 min of fluoroscopic time). When the CTO was crossed, routine angioplasty with or without stent was performed. Efficacy was defined as achievement of distal lumen position. Safety was defined as device success without perforation, dissection (≥Grade C), or distal embolization. The mean patient age was 72 years with 8 females and 10 males. Lesion characteristics included a mean vessel diameter of 5.8 mm and a mean lesion length of 22.4 cm. Ankle-brachial indices was ≤0.8 in all patients. Results: The OCR system was successful in crossing 100% of the CTOs in patients that failed conventional wire crossing, whereas clinical success occurred in 94% of these patients. Complications consisted of a single dissection ≥Grade C. No perforations or distal embolization occurred. Conclusions: The Safe-Cross OCR System is both efficacious and safe in the treatment of CTOs that failed crossing with conventional wires and indirect visualization of the intraluminal position by using OCR technology appears to minimize vessel trauma, dissection, perforation, and distal embolization.
- 1 December 2006
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 19 (6) , 530-538
Review of Interventional Repair for Abdominal Aortic Aneurysm
Abdominal aortic aneurysm is associated with high mortality rate. For over 50 years, open surgical repair was the standard approach for large aneurysms. However, over the past decade, endovascular aneurysm repair (EVAR) has emerged as a viable alternative. EVAR is associated with lower operative and short-term morbidity and mortality and similar long-term survival (up to 4 years) compared with surgical repair. Endoleak remains a significant limitation associated with aneurysm expansion and reintervention. With newer, more versatile endograft designs, improvements in durability, and better surveillance techniques, the utilization of EVAR is likely to continue to expand.
- 1 December 2006
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 19 (6) , 530-538
Review of Interventional Repair for Abdominal Aortic Aneurysm
Abdominal aortic aneurysm is associated with high mortality rate. For over 50 years, open surgical repair was the standard approach for large aneurysms. However, over the past decade, endovascular aneurysm repair (EVAR) has emerged as a viable alternative. EVAR is associated with lower operative and short-term morbidity and mortality and similar long-term survival (up to 4 years) compared with surgical repair. Endoleak remains a significant limitation associated with aneurysm expansion and reintervention. With newer, more versatile endograft designs, improvements in durability, and better surveillance techniques, the utilization of EVAR is likely to continue to expand.
- 10 November 2006
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 19 (6) , 525-529
Embolic Protection Devices in Saphenous Vein Graft Interventions
Saphenous vein grafts (SVGs) are widely used as aortocoronary conduits during coronary artery bypass surgery and are critical in the high early success of coronary bypass revascularization. Saphenous vein grafts tend to be more prone than native coronary arteries to accelerated atherosclerosis and intimal fibrosis and thus frequently lead to recurrent symptoms and require further revascularization. Percutaneous coronary interventions (PCI) have become the prime means of SVG mechanical revascularization but are plagued by higher complication rates than PCI on native coronaries, largely due to embolic debris mobilized from around the target lesion in the SVG. Several mechanical devices and techniques have been developed to capture this friable material during the PCI before it can embolize; these devices have shown great promise in reducing the morbidity and mortality of these interventions and should be employed routinely.
- 10 November 2006
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 19 (6) , 525-529
Embolic Protection Devices in Saphenous Vein Graft Interventions
Saphenous vein grafts (SVGs) are widely used as aortocoronary conduits during coronary artery bypass surgery and are critical in the high early success of coronary bypass revascularization. Saphenous vein grafts tend to be more prone than native coronary arteries to accelerated atherosclerosis and intimal fibrosis and thus frequently lead to recurrent symptoms and require further revascularization. Percutaneous coronary interventions (PCI) have become the prime means of SVG mechanical revascularization but are plagued by higher complication rates than PCI on native coronaries, largely due to embolic debris mobilized from around the target lesion in the SVG. Several mechanical devices and techniques have been developed to capture this friable material during the PCI before it can embolize; these devices have shown great promise in reducing the morbidity and mortality of these interventions and should be employed routinely.
- 1 March 2006
- Published by Wiley in American Heart Hospital Journal
- Vol. 4 (2) , 106-112
Devices for Chronic Occlusion
- 1 March 2006
- Published by Wiley in American Heart Hospital Journal
- Vol. 4 (2) , 106-112
Devices for Chronic Occlusion
- 1 December 2005
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 18 (6) , 481-484
Distal Embolic Protection for SVG Interventions: Can We Afford Not to Use It?
The development of atherosclerosis in saphenous vein grafts (SVGs) is one of the limiting factors in coronary artery bypass surgery. Approximately one half of vein conduits are significantly diseased or occluded at 10 years. A surgical revascularization strategy is often not pursued secondary to the incremental risks associated with a repeat bypass procedure. For this reason, percutaneous treatment of SVG disease is often the first option for a majority of patients. However, catheter-based treatment of SVG disease is associated with increased morbidity and mortality compared with native coronary arterial percutaneous intervention. This is often the result of distal embolization of atherothrombotic disease, leading to the phenomenon of "no-reflow." Intraprocedural pharmacological therapy has historically been the mainstay of treatment for these patients. However, more recently, the development of a mechanical embolic protection device has shown to be beneficial for the prevention of these complications. This article will review the types of embolic protection devices and the clinical studies that have proven their necessity in percutaneous SVG intervention.
- 1 December 2005
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 18 (6) , 481-484
Distal Embolic Protection for SVG Interventions: Can We Afford Not to Use It?
The development of atherosclerosis in saphenous vein grafts (SVGs) is one of the limiting factors in coronary artery bypass surgery. Approximately one half of vein conduits are significantly diseased or occluded at 10 years. A surgical revascularization strategy is often not pursued secondary to the incremental risks associated with a repeat bypass procedure. For this reason, percutaneous treatment of SVG disease is often the first option for a majority of patients. However, catheter-based treatment of SVG disease is associated with increased morbidity and mortality compared with native coronary arterial percutaneous intervention. This is often the result of distal embolization of atherothrombotic disease, leading to the phenomenon of "no-reflow." Intraprocedural pharmacological therapy has historically been the mainstay of treatment for these patients. However, more recently, the development of a mechanical embolic protection device has shown to be beneficial for the prevention of these complications. This article will review the types of embolic protection devices and the clinical studies that have proven their necessity in percutaneous SVG intervention.