GSGulnara Scaf

Gulnara Scaf

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gulnara Scaf has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Detection of Simulated Periodontal Bone Defects Using Digital Images. An in vitro Study

    by Rafael Molon, Mario Verzola, Talita Paquier, Juliana MoraisCamillo, Ivy TrindadeSuedam, Leonor Loffredo, Gulnara Scaf


  • Open Access

    Comparison between inverted and unprocessed digitized radiographic imaging in periodontal bone loss measurements

    by Gulnara Scaf, Olívia Morihisa, Leonor de Castro Monteiro Loffredo

    The advances in digital imaging technology in dentistry have provided an alternative to film-based radiography and have given new options to detect periodontal bone loss. The purpose of this study was to compare inverted and unprocessed digitized radiographic imaging in periodontal bone loss measurements. Thirty-five film-based periapical radiographs of patients suffering from moderate to advanced untreated periodontal bone loss associated to lower premolar and molars was selected from the department files, with 40 bone loss areas. The film-based radiographs were digitized with a flatbed scanner with a transparency and radiograph adapter used for transilluminating the radiograph imaging. Digitization was performed at 600 dpi and in gray scale. The images were digitized using Image Tool software by applying image inversion, that is, transformation of radiopaque structures into radiolucent structures and vice-versa. The digital data were saved as JPEG files. The images were displayed on a 15-inch and 24-bit video monitor under reduced room lighting. One calibrated examiner performed all radiographic measurements, three times, from the cementoenamel junction to the most apical extension of the bone loss, in both types of image (inverted and unprocessed). Brightness and contrast were adjusted according to the examiner's individual demand. Intraclass correlation coefficient was used to compare the measurements from both types of images. The means of radiographic measurements, in mm, for inverted and unprocessed digitized imaging were 6.4485 and 6.3790, respectively. The intraclass correlation coefficient was significant (0.99) The inverted and unprocessed digitized radiographic images were reliable and there was no difference in the diagnostic accuracy between these images regarding periodontal bone loss measurements.


  • Influence of cyclosporin A on quality of bone around integrated dental implants: a radiographic study in rabbits

    by Celso Eduardo Sakakura, Elcio Marcantonio, Ann Wenzel, Gulnara Scaf

    Objectives: To evaluate the influence of cyclosporin A (CsA) administration on bone around integrated dental implants assessed by a bone quality index and by quantitative subtraction radiography.Material and methods: A total of 36 machine surface commercial implants were placed in 18 adult rabbits. After a 3‐month healing period without any disturbance, the animals were randomly divided into three groups of six animals each. Group A was sacrificed at this time. CsA was injected subcutaneously in an immunosuppressive dose of 10 mg/kg/day in a test group (Group T), and a Group B served as a control, receiving only vehicle. After 3 months of cyclosporin administration, the animals of both Groups B and T were sacrificed. Radiographs were obtained at implant surgery and at the day of sacrifice with a CMOS sensor. Bone quality around the implants was compared between the groups using a bone quality index and quantitative subtraction radiography.Results: The bone analysis showed that in Group T, the bone quality changed dramatically from a dense cortical to a loose trabecular bone structure (P2 test) while in Groups A and B there were no significant differences. Quantitative digital subtraction radiography showed significantly (PConclusion: Within the limits of this study, CsA administration has a negative effect on the quality of bone around integrated dental implant.


  • Comparison of simulated periodontal bone defect depth measured in digital radiographs in dedicated and non-dedicated software systems

    by G Scaf, Ce Sakakura, Pfd Kalil, Jan Dearo de Morais, Lcm Loffredo, A Wenzel

    To compare simulated periodontal bone defect depth measured in digital radiographs with dedicated and non-dedicated software systems and to compare the depth measurements from each program with the measurements in dry mandibles. Forty periodontal bone defects were created at the proximal area of the first premolar in dry pig mandibles. Measurements of the defects were performed with a periodontal probe in the dry mandible. Periapical digital radiographs of the defects were recorded using the Schick sensor in a standardized exposure setting. All images were read using a Schick dedicated software system (CDR DICOM for Windows v.3.5), and three commonly available non-dedicated software systems (Vix Win 2000 v.1.2; Adobe Photoshop 7.0 and Image Tool 3.0). The defects were measured three times in each image and a consensus was reached among three examiners using the four software systems. The difference between the radiographic measurements was analysed using analysis of variance (ANOVA) and by comparing the measurements from each software system with the dry mandibles measurements using Student's t-test. The mean values of the bone defects measured in the radiographs were 5.07 mm, 5.06 mm, 5.01 mm and 5.11 mm for CDR Digital Image and Communication in Medicine (DICOM) for Windows, Vix Win, Adobe Photoshop, and Image Tool, respectively, and 6.67 mm for the dry mandible. The means of the measurements performed in the four software systems were not significantly different, ANOVA (P = 0.958). A significant underestimation of defect depth was obtained when we compared the mean depths from each software system with the dry mandible measurements (t-test; P approximately equal to 0.000). The periodontal bone defect measurements in dedicated and in three non-dedicated software systems were not significantly different, but they all underestimated the measurements when compared with the measurements obtained in the dry mandibles.


  • Open Access

    Efficacy of three conditions of radiographic interpretation for assessment root canal length

    by Mitsuru Ogata, Leonor de Castro Monteiro Loffredo, Milton Carlos Kuga, Gulnara Scaf

    OBJECTIVE: To compare the efficacy of three conditions of image interpretation for radiographic root measurements and calculating the intra-observer reproducibility of the measurements. MATERIAL AND METHODS: Thirty intra-operative periapical radiographs of maxillary central and lateral incisors were measured, in mm, from the tip of the file to the radiographic apex, using a caliper. Three separate measurements were made of the 30 radiographs. The three measurements for each tooth were averaged and the mean used for further calculations. After a 12-day period, the measurements were repeated. The three experimental viewing conditions used: 1) standard viewbox without masking of background light around the radiograph and without magnification (Visual); 2) standard viewbox with use of a magnifying lens of 2.5x and with background light masked (Magnification); and 3) viewer device that restricts room lighting and enlarges the image by a magnifying lens of 1.75x (Viewer). The mean and standard deviation of the measurements were calculated and used for descriptive analysis. Two-way analysis of variance (ANOVA) was used to evaluate intra-observer and inter-method agreement of the measurements. The measurement error was estimated by Dalhberg's formula. RESULTS: The ANOVA showed no significant differences between measurement sessions, viewing methods, or interaction between observation session and method (p>0.05). The intra-observer measurement error was 0.02 mm for Visual and the Magnification methods and 0.01 mm for the Viewer. CONCLUSION: There does not seem to be any advantage in using viewbox masking or magnification for measuring the distance between the end of the endodontic file and the root apex in maxillary incisors.


  • Open Access

    Diagnostic reproducibility of the elongated styloid process

    by Gulnara Scaf, Deborah Queiroz de Freitas, Leonor de Castro Monteiro Loffredo

    The aim of this study was to estimate the reproducibility related to the presence and to the measurements of elongated styloid process (ESP), based on panoramic radiographs and the prevalence of ESP. Experimental design: one hundred sixty six panoramic radiographs were used, from edentulous patients from the Radiology Clinic files, at Araraquara Dental School, Unesp, during a four-year period. One hundred and twenty one were female and 45 were male. Two calibrated observers evaluated the radiographs. A caliper was used to measure, in mm, the ESP from the base of the temporal bone to the tip of the structure. The ESP was considered present when the measurements were 30mm or more. Kappa statistics (k ) and intra-class correlation coefficient (r ), were applied to estimate the reproducibility. The results showed that related to the presence of ESP, the interobserver agreement was k =0.85. Related to the measurements of ESP, the interobserver agreement was r =0.52. The prevalence of ESP was estimated in 12.6%. ESP distribution in females was similar to that for males. In conclusion, we found a greater level of agreement when observers evaluated the presence of ESP than when they did the measurement of ESP. The prevalence of ESP was 12.6%.