AGAnna Goransson

Anna Goransson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Anna Goransson has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • A. Wennerberg

    Department of Biomaterials, Institute of Surgical Science, Sahlgrenska Academy at Göteborg University, Göteborg, Sweden

    2 shared publications
  • Ann Wennerberg

    Department of Biomaterial Science, Institute of Surgical Science, Sahlgrenska Academy at Göteborg University, Sweden

    2 shared publications
  • A Wennerberg

    1 shared publication
  • A. Arvidsson

    Department of Biomaterials, Institute of Surgical Science, Sahlgrenska Academy at Göteborg University, Göteborg, Sweden

    1 shared publication
  • Anna Johansson

    Department of Biomaterial Science, Institute of Surgical Science, Sahlgrenska Academy at Göteborg University, Sweden

    1 shared publication
  • C. Gretzer

    Department of Biomaterial Science, Institute of Surgical Science, Sahlgrenska Academy, Göteborg University, Göteborg, Sweden

    1 shared publication

Latest Publications

  • An in vitro comparison of possibly bioactive titanium implant surfaces

    by A. Göransson, A. Arvidsson, F. Currie, V. Franke‐Stenport, P. Kjellin, K. Mustafa, Y. T. Sul, A. Wennerberg

    The aim of the study was to compare Ca and P formation (CaP) and subsequent bone cell response of a blasted and four different possibly bioactive commercially pure (cp) titanium surfaces; 1. Fluoride etched (Fluoride), 2. Alkali‐heat treated (AH), 3. Magnesium ion incorporated anodized (TiMgO), and 4. Nano HA coated and heat treated (nano HA) in vitro. Furthermore, to evaluate the significance of the SBF formed CaP coat on bone cell response. The surfaces were characterized by Optical Interferometry, Scanning Electron Microscopy (SEM) and X‐ray Photoelectron Spectroscopy (XPS). CaP formation was evaluated after 12, 24 and 72 h in simulated body fluid (SBF). Primary human mandibular osteoblast‐like cells were cultured on the various surfaces subjected to SBF for 72 h. Cellular attachment, differentiation (osteocalcin) and protein production (TGF‐β1) was evaluated after 3 h and 10 days respectively. Despite different morphological appearances, the roughness of the differently modified surfaces was similar. The possibly bioactive surfaces gave rise to an earlier CaP formation than the blasted surface, however, after 72 h the blasted surface demonstrated increased CaP formation compared to the possibly bioactive surfaces. Subsequent bone cell attachment was correlated to neither surface roughness nor the amount of formed CaP after SBF treatment. In contrast, osteocalcin and TGF‐β1 production were largely correlated to the amount of CaP formed on the surfaces. However, bone response (cell attachment, osteocalcin and TGF‐F production) on the blasted controls were similar or increased compared to the SBF treated fluoridated, AH and TiMgO surface. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2009


  • Inflammatory response to titanium surfaces with fibrinogen and catalase coatings: An in vitro study

    by A. Göransson, C. Gretzer, P. Tengvall, A. Wennerberg

    The aim of the present study was to evaluate the possibility to modulate the early inflammatory response in vitro by coating titanium surfaces with candidate proinflammatory (fibrinogen coated turned titanium “Fib”) and antiinflammatory proteins (catalase on top of fibrinogen coated turned titanium “Cat”). Additionally, turned titanium surfaces (Ti) were used as controls. The discs were incubated with human mononuclear cells. Adhered cells were investigated with respect to number, viability, differentiation (acute marker 27E10 vs. chronic marker RM3/1), and cytokine production (TNF‐α and IL‐10), after 24 and 72 h. The results indicated that it is possible to modulate the inflammatory response with protein coatings. However, the strongest inflammatory response, indicated by increased number of adhered cells and release of pro and antiinflammatory mediators, was induced by Cat. Furthermore, the cytokine production on this surface was not sensitive to LPS stimulation. Differentiation measured as the expression of the chronic cell surface marker, dominated after 72 h for all surface modifications and Cat displayed an increased number compared to the others. A decrease in the total number of adhered cells and amounts of TNF‐α were observed on all surfaces over time. The cell viability was, in general, high for all tested surfaces. In conclusion, the study proved it possible to influence the early inflammatory response in vitro by immobilizing protein coatings to titanium surfaces. However, the catalase surface demonstrated the strongest inflammatory response, and the possibility to selectively use the potent antiinflammatory capacity of catalase needs to be further evaluated. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res 2007


  • Inflammatory Response to a Titanium Surface with Potential Bioactive Properties: An In Vitro Study

    by Anna Göransson, Christina Gretzer, Anna Johansson, Young‐Taeg Sul, Ann Wennerberg

    The current hard tissue implants research aims to accelerate bone healing by designing surfaces that are bioactive. However, the role of the inflammatory response to these surfaces is so far incompletely described. The aim of the study was to evaluate early inflammatory response in vitro to a potentially bioactive surface--an anodized surface with Mg ions incorporated (anodized/Mg)--and to compare it to a turned, a blasted, and an anodized surface. An interferometer was used for topographical characterizations. The disks were incubated with human mononuclear cells. Adherent cells were investigated with respect to number of cells, viability, differentiation, and cytokine production with and without lipopolysaccharide stimulation after 24 and 72 hours. The number of adhered mononuclear cells differed significantly between the different modified surfaces, with the highest number on the anodized surface. However, there were no significant differences in cytokine production and differentiation between the different modified surfaces. The amount of anti-inflammatory mediator interleukin-10 remained over time, while the number of cells and pro-inflammatory cytokine tumor necrosis factor-alpha decreased. The cells were viable on all surfaces, respectively. The anodized surfaces with and without Mg ions showed an increased cell adherence, however, otherwise an inflammatory response similar to the turned and blasted surfaces. Furthermore, the potentially bioactive anodized/Mg surface showed a similar response to the TiUnite-like anodized surface despite the former having a surface roughness of a smoother character.