Satoshi Saito
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Satoshi Saito has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Satoshi Ota
5 shared publicationsHideyuki Seshimo
4 shared publicationsHirofumi Fukushima
4 shared publicationsSetsuo Nomura
4 shared publicationsKeiko Tamaki
3 shared publicationsYuichiro Yamazaki
3 shared publications
Latest Publications
- 1 January 2006
- Published by Japan Society of Transfusion Medicine and Cell Therapy in Journal of the Japan Society of Blood Transfusion
- Vol. 52 (3) , 405-413
PLATELET TRANSFUSION REFRACTORINESS ASSOCIATED WITH IGM-HLA-CLASS I ANTIBODIES-IMMUNOGLOBULIN CLASS HETEROGENEITY OF HLA CLASS I ANTIBODIES IN PTR PATIENTS
HLAクラスI抗体が血小板輸血不応状態 (platelet transfusion refractoriness: PTR) に関与することについては数多くの報告があるが, IgM型のHLAクラスI抗体 (IgM-HLA抗体) のPTRへの関与についての報告はほとんどない. そこで, PTR患者121人の凍結保存血清のHLA抗体スクリーニングを, 磁性粒子を用いた Mixed passive hemagglutination assay (M-MPHA) 法, Flow cytometric reagents for detection of panel-reactive antibody against HLA Class I antigens (FlowPRA) 法, Anti-human immunoglobulin lymphocyte cytotoxity test (AHG-LCT) 法により行い, IgM-HLA抗体のPTRへの関与については, 輸血24時間後の補正血小板増加数 (CCI24hours) による血小板輸血効果から推測した. その結果, M-MPHA法により121症例中48症例からIgM-HLA抗体が検出された. 一方, FlowPRA法により検出できたIgM-HLA抗体は, それら48例中35例, AHG-LCT法では20例のみであった. 血小板輸血効果は, IgM-HLA抗体を保有する, 48症例中7症例74輸血において判定できた. IgM-HLA抗体の特異性に対応する抗原を持たない輸血では, CCI24hoursが19.7±4.7(×109/L) を示し輸血効果を得ることができたが, 対応する抗原を持つ輸血では, CCI24hoursが2.0±19(×109/L) を示し輸血効果を得られなかった. PTR患者に高頻度に存在するIgM-HLA抗体は, PTRの原因になると考えられ, その半数以上はAHG-LCT法により検出できなかった. M-MPHAをHLA抗体スクリーニング, 血小板輸血の際の交差試験に用いることで, PTR症例の原因解析と輸血効果の向上に貢献できる可能性がある.
- 1 January 2006
- Published by Japan Society of Transfusion Medicine and Cell Therapy in Journal of the Japan Society of Blood Transfusion
- Vol. 52 (3) , 405-413
PLATELET TRANSFUSION REFRACTORINESS ASSOCIATED WITH IGM-HLA-CLASS I ANTIBODIES-IMMUNOGLOBULIN CLASS HETEROGENEITY OF HLA CLASS I ANTIBODIES IN PTR PATIENTS
HLAクラスI抗体が血小板輸血不応状態 (platelet transfusion refractoriness: PTR) に関与することについては数多くの報告があるが, IgM型のHLAクラスI抗体 (IgM-HLA抗体) のPTRへの関与についての報告はほとんどない. そこで, PTR患者121人の凍結保存血清のHLA抗体スクリーニングを, 磁性粒子を用いた Mixed passive hemagglutination assay (M-MPHA) 法, Flow cytometric reagents for detection of panel-reactive antibody against HLA Class I antigens (FlowPRA) 法, Anti-human immunoglobulin lymphocyte cytotoxity test (AHG-LCT) 法により行い, IgM-HLA抗体のPTRへの関与については, 輸血24時間後の補正血小板増加数 (CCI24hours) による血小板輸血効果から推測した. その結果, M-MPHA法により121症例中48症例からIgM-HLA抗体が検出された. 一方, FlowPRA法により検出できたIgM-HLA抗体は, それら48例中35例, AHG-LCT法では20例のみであった. 血小板輸血効果は, IgM-HLA抗体を保有する, 48症例中7症例74輸血において判定できた. IgM-HLA抗体の特異性に対応する抗原を持たない輸血では, CCI24hoursが19.7±4.7(×109/L) を示し輸血効果を得ることができたが, 対応する抗原を持つ輸血では, CCI24hoursが2.0±19(×109/L) を示し輸血効果を得られなかった. PTR患者に高頻度に存在するIgM-HLA抗体は, PTRの原因になると考えられ, その半数以上はAHG-LCT法により検出できなかった. M-MPHAをHLA抗体スクリーニング, 血小板輸血の際の交差試験に用いることで, PTR症例の原因解析と輸血効果の向上に貢献できる可能性がある.
- 1 January 2005
- Published by Japan Society of Transfusion Medicine and Cell Therapy in Journal of the Japan Society of Blood Transfusion
- Vol. 51 (5) , 530-536
ANALYSIS OF AN HLA-B MOSAICISM OBSERVED IN APHERESIS DONOR
- 1 January 2005
- Published by Japan Society of Transfusion Medicine and Cell Therapy in Journal of the Japan Society of Blood Transfusion
- Vol. 51 (5) , 530-536
ANALYSIS OF AN HLA-B MOSAICISM OBSERVED IN APHERESIS DONOR
- 1 January 2004
- Published by Japan Society of Transfusion Medicine and Cell Therapy in Journal of the Japan Society of Blood Transfusion
- Vol. 50 (6) , 753-760
SENSITIVITY OF VARIOUS METHODS FOR DETECTING HLA CLASS I ANTIBODIES AND SCREENING FOR ALLOANTIBODIES IN 145 SERA SAMPLES FROM PATIENTS RECEIVING PLATELET TRANSFUSIONS: A COMPARISON OF AHG-LCT, LIFT, PIFT, MAGNETIC MPHA AND FlowPRA METHODS
A total of 15 distinct human sera that did not exhibit reactivity against HPA antibodies but contained HLA-specific antibodies were used for sensitivity analysis of the AHG-LCT, LIFT, PIFT, M-MPHA and FlowPRA methods. The HLA antibody titer of each serum sample was defined as the highest dilution of serum that became positive to each method. 145 sera samples from patients receiving platelet transfusions were also screened to detect HLA antibodies by these methods. Results showed that FlowPRA was the most sensitive for identifying HLA antibodies. Although FCM is generally considered the most sensitive method, our analysis suggests that M-MPHA is as useful as FCM in both sensitivity and screening tests. PIFT sensitivity was slightly less than that of LIFT and M-MPHA. AHG-LCT sensitivity was significantly less than that of the other methods.
- 1 January 2004
- Published by Japan Society of Transfusion Medicine and Cell Therapy in Journal of the Japan Society of Blood Transfusion
- Vol. 50 (6) , 753-760
SENSITIVITY OF VARIOUS METHODS FOR DETECTING HLA CLASS I ANTIBODIES AND SCREENING FOR ALLOANTIBODIES IN 145 SERA SAMPLES FROM PATIENTS RECEIVING PLATELET TRANSFUSIONS: A COMPARISON OF AHG-LCT, LIFT, PIFT, MAGNETIC MPHA AND FlowPRA METHODS
A total of 15 distinct human sera that did not exhibit reactivity against HPA antibodies but contained HLA-specific antibodies were used for sensitivity analysis of the AHG-LCT, LIFT, PIFT, M-MPHA and FlowPRA methods. The HLA antibody titer of each serum sample was defined as the highest dilution of serum that became positive to each method. 145 sera samples from patients receiving platelet transfusions were also screened to detect HLA antibodies by these methods. Results showed that FlowPRA was the most sensitive for identifying HLA antibodies. Although FCM is generally considered the most sensitive method, our analysis suggests that M-MPHA is as useful as FCM in both sensitivity and screening tests. PIFT sensitivity was slightly less than that of LIFT and M-MPHA. AHG-LCT sensitivity was significantly less than that of the other methods.
- 20 June 2003
- Published by Wiley in Transfusion
- Vol. 43 (7) , 908-917
Serologic analysis of three cases of neonatal alloimmune thrombocytopenia associated with HLA antibodies
BACKGROUND: Neonatal alloimmune thrombocytopenia (NAIT) is caused when maternal alloantibodies react with paternally inherited antigens present on the fetal PLTs, a reaction mainly due to antibodies against human PLT antigens. Cases in which NAIT has been caused by HLA antibodies are relatively rare. In this study, three cases of NAIT associated with HLA antibodies that occurred in a 1‐year period are reported.STUDY DESIGN AND METHODS: The presence of HLA antibodies in these three NAIT case studies was elucidated by examining reactions of the neonatal and maternal sera with lymphocytes, PLTs, and beads from an HLA antibody screening test (FlowPRA, One Lambda Inc.). Absorption and elution tests with paternal cells were also conducted. In addition, the influence of titer and specificity of HLA antibodies on NAIT was analyzed in light of 24 other documented cases in Japan.RESULTS: In the three case studies presented herein, antibodies against human PLT antigens were found in neither the maternal nor neonatal sera, while specific HLA antibodies were identified in both sera. Absorption of maternal serum with paternal PLTs eliminated the reactivity against paternal PLTs and lymphocytes.CONCLUSION: Transplacental passage of maternal HLA antibodies was observed in the three neonates cited in the present study.
- 20 June 2003
- Published by Wiley in Transfusion
- Vol. 43 (7) , 908-917
Serologic analysis of three cases of neonatal alloimmune thrombocytopenia associated with HLA antibodies
BACKGROUND: Neonatal alloimmune thrombocytopenia (NAIT) is caused when maternal alloantibodies react with paternally inherited antigens present on the fetal PLTs, a reaction mainly due to antibodies against human PLT antigens. Cases in which NAIT has been caused by HLA antibodies are relatively rare. In this study, three cases of NAIT associated with HLA antibodies that occurred in a 1‐year period are reported.STUDY DESIGN AND METHODS: The presence of HLA antibodies in these three NAIT case studies was elucidated by examining reactions of the neonatal and maternal sera with lymphocytes, PLTs, and beads from an HLA antibody screening test (FlowPRA, One Lambda Inc.). Absorption and elution tests with paternal cells were also conducted. In addition, the influence of titer and specificity of HLA antibodies on NAIT was analyzed in light of 24 other documented cases in Japan.RESULTS: In the three case studies presented herein, antibodies against human PLT antigens were found in neither the maternal nor neonatal sera, while specific HLA antibodies were identified in both sera. Absorption of maternal serum with paternal PLTs eliminated the reactivity against paternal PLTs and lymphocytes.CONCLUSION: Transplacental passage of maternal HLA antibodies was observed in the three neonates cited in the present study.
- 1 March 2002
- Published by Wiley in Transfusion
- Vol. 42 (3) , 302-308
Platelet transfusion refractoriness caused by a mismatch in HLA‐C antigens
BACKGROUND: HLA‐C antigens have been thought to be of little significance in determining the efficacy of platelet transfusions. However, six alloimmunized patients were encountered who were refractory to platelet transfusions because of anti‐HLA‐Cw3, ‐Cw7, or ‐Cw8. STUDY DESIGN AND METHODS: Between 1995 and the present, 88 patients with hematologic malignancies became refractory to random‐donor platelet transfusions due to HLA antibodies. HLA‐A‐ and HLA‐B‐compatible platelet transfusions were successful in boosting platelet levels with 82 of the patients. This study concerns the remaining six HLA‐immunized patients who were refractory to HLA‐A‐ and HLA‐B‐compatible platelet transfusions. The response to the platelet transfusions was assessed by calculating both 1‐ and 24‐hour posttransfusion CCIs for each transfusion. RESULTS: The average CCI1 hour and CCI24 hours in all patients were 20.0 and 12.8 for HLA‐A‐, HLA‐B‐, and HLA‐C‐compatible transfusions and were 1.4 and 1.2 for HLA‐A‐ and HLA‐B‐compatible but HLA‐C‐incompatible transfusions, respectively (p < 0.001). CONCLUSION: These findings clearly indicate that matching of the HLA‐C antigens is also required in some alloimmunized patients to obtain the effectiveness of platelet transfusions.
- 1 March 2002
- Published by Wiley in Transfusion
- Vol. 42 (3) , 302-308
Platelet transfusion refractoriness caused by a mismatch in HLA‐C antigens
BACKGROUND: HLA‐C antigens have been thought to be of little significance in determining the efficacy of platelet transfusions. However, six alloimmunized patients were encountered who were refractory to platelet transfusions because of anti‐HLA‐Cw3, ‐Cw7, or ‐Cw8. STUDY DESIGN AND METHODS: Between 1995 and the present, 88 patients with hematologic malignancies became refractory to random‐donor platelet transfusions due to HLA antibodies. HLA‐A‐ and HLA‐B‐compatible platelet transfusions were successful in boosting platelet levels with 82 of the patients. This study concerns the remaining six HLA‐immunized patients who were refractory to HLA‐A‐ and HLA‐B‐compatible platelet transfusions. The response to the platelet transfusions was assessed by calculating both 1‐ and 24‐hour posttransfusion CCIs for each transfusion. RESULTS: The average CCI1 hour and CCI24 hours in all patients were 20.0 and 12.8 for HLA‐A‐, HLA‐B‐, and HLA‐C‐compatible transfusions and were 1.4 and 1.2 for HLA‐A‐ and HLA‐B‐compatible but HLA‐C‐incompatible transfusions, respectively (p < 0.001). CONCLUSION: These findings clearly indicate that matching of the HLA‐C antigens is also required in some alloimmunized patients to obtain the effectiveness of platelet transfusions.