Shin-Ichi Nitta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Shin-Ichi Nitta has a total of 112 co-authors. Here are the top co-authors by number of shared publications:
T Yambe
19 shared publicationsS Naganuma
17 shared publicationsY Katahira
17 shared publicationsM Miura
14 shared publicationsT Sonobe
14 shared publicationsM Tanaka
12 shared publications
Latest Publications
- 31 December 2009
- Published by Elsevier in European Journal of Integrative Medicine
- Vol. 1 (4) , 186
Hemodynamics of the radial artery, the site of traditional pulse diagnosis
- 31 December 2009
- Published by Elsevier in European Journal of Integrative Medicine
- Vol. 1 (4) , 186
Hemodynamics of the radial artery, the site of traditional pulse diagnosis
- 31 December 2009
- Published by Elsevier in European Journal of Integrative Medicine
- Vol. 1 (4) , 187
Effect of acupuncture on cardiac output
- 31 December 2009
- Published by Elsevier in European Journal of Integrative Medicine
- Vol. 1 (4) , 187
Effect of acupuncture on cardiac output
- Open Access
- 28 September 2007
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 4 (1) , 35
Evaluation of adaptation to visually induced motion sickness based on the maximum cross-correlation between pulse transmission time and heart rate
Computer graphics and virtual reality techniques are useful to develop automatic and effective rehabilitation systems. However, a kind of virtual environment including unstable visual images presented to wide field screen or a head mounted display tends to induce motion sickness. The motion sickness induced in using a rehabilitation system not only inhibits effective training but also may harm patients' health. There are few studies that have objectively evaluated the effects of the repetitive exposures to these stimuli on humans. The purpose of this study is to investigate the adaptation to visually induced motion sickness by physiological data.
- 28 September 2007
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 4 (1) , 35
Open AccessEvaluation of adaptation to visually induced motion sickness based on the maximum cross-correlation between pulse transmission time and heart rate
Computer graphics and virtual reality techniques are useful to develop automatic and effective rehabilitation systems. However, a kind of virtual environment including unstable visual images presented to wide field screen or a head mounted display tends to induce motion sickness. The motion sickness induced in using a rehabilitation system not only inhibits effective training but also may harm patients' health. There are few studies that have objectively evaluated the effects of the repetitive exposures to these stimuli on humans. The purpose of this study is to investigate the adaptation to visually induced motion sickness by physiological data.
- 20 January 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 756
An automatic monitoring system for artificial hearts using self-organizing map
The overall goal of the authors' research is an automatic, real-time and on-line monitoring system of artificial hearts. In this task, it is very important to automatically detect and classify abnormalities of the artificial heart control system and the recipient's circulatory system. The self-organizing map was applied to the pattern recognition of aortic pressure (AOP) which is considered to mostly represent the state of the circulatory system. The AOP signal data were fed to a Self-Organizing Map (SOM) beat by beat. During the unsupervised learning process the SOM units organize in such a way that similar AOP beat patterns were represented in particular areas of the SOM. The map location areas of the AOP signals in the different states of the circulatory system were also different. The results of visual examination revealed that the states of circulatory system were distinguished well by the map. It is expected that a map can be trained off-line with a large database and then used for on-line monitoring and analysis for artificial hearts Author(s) Xian-Sheng Wang Graduate Sch. of Eng., Tohoku Gakuin Univ., Sendai, Japan Yoshizawa, M. ; Tanaka, A. ; Abe, K. ; Takeda, H. ; Yambe, T. ; Nitta, S. ; Imachi, K.
- 20 January 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 756
An automatic monitoring system for artificial hearts using self-organizing map
The overall goal of the authors' research is an automatic, real-time and on-line monitoring system of artificial hearts. In this task, it is very important to automatically detect and classify abnormalities of the artificial heart control system and the recipient's circulatory system. The self-organizing map was applied to the pattern recognition of aortic pressure (AOP) which is considered to mostly represent the state of the circulatory system. The AOP signal data were fed to a Self-Organizing Map (SOM) beat by beat. During the unsupervised learning process the SOM units organize in such a way that similar AOP beat patterns were represented in particular areas of the SOM. The map location areas of the AOP signals in the different states of the circulatory system were also different. The results of visual examination revealed that the states of circulatory system were distinguished well by the map. It is expected that a map can be trained off-line with a large database and then used for on-line monitoring and analysis for artificial hearts Author(s) Xian-Sheng Wang Graduate Sch. of Eng., Tohoku Gakuin Univ., Sendai, Japan Yoshizawa, M. ; Tanaka, A. ; Abe, K. ; Takeda, H. ; Yambe, T. ; Nitta, S. ; Imachi, K.
- 1 March 1999
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 45 (2) , 160
AUTOMATIC CONTROL ARGORITHM FOR AN ARTIFICIAL HEART MAKES CHAOS
- 1 March 1999
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 45 (2) , 160
AUTOMATIC CONTROL ARGORITHM FOR AN ARTIFICIAL HEART MAKES CHAOS
- 1 March 1999
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 45 (2) , 159
AN IMPLANTABLE VENTRICULAR ASSIST SYSTEM WITH SHORT STROKE AND HIGH FREQUENCY
- 1 March 1999
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 45 (2) , 159
AN IMPLANTABLE VENTRICULAR ASSIST SYSTEM WITH SHORT STROKE AND HIGH FREQUENCY
- 1 January 1999
- Published by Wiley in Artificial Organs
- Vol. 23 (1) , 119-123
Chaotic Dynamics in Circulation with Tohoku University Vibrating Flow Pump
For the development of a totally implantable ventricular assist system (VAS), we have been developing the vibrating flow pump (VFP), which can generate oscillated blood flow with a relative high frequency (10–50 Hz) for a totally implantable system. In this study, the effects of left ventricular assistance with this unique oscillated blood flow were analyzed by the use of nonlinear mathematics for evaluation as the whole circulatory regulatory system, not as the decomposed parts of the system. Left heart bypasses using the VFP from the left atrium to the descending aorta were performed in chronic animal experiments using healthy adult goats. The ECG, arterial blood pressure, VFP pump flow, and the flow of the descending aorta were recorded in the data recorder during awake conditions and analyzed in a personal computer system through an A–D convertor. By the use of nonlinear mathematics, time series data were embedded into the phase space, the Lyapunov numerical method, fractal dimension analysis, and power spectrum analysis were performed to evaluate nonlinear dynamics. During left ventricular assistance with the VFP, Mayer wave fluctuations were decreased in the power spectrum, the fractal dimension of the hemodynamics was significantly decreased, and peripheral vascular resistance was significantly decreased. These results suggest that nonlinear dynamics, which mediate the cardiovascular dynamics, may be affected during left ventricular (LV) bypass with oscillated flow. The decreased power of the Mayer wave in the spectrum caused the limit cycle attractor of the hemodynamics and decreased peripheral resistance. Decreased sympathetic discharges may be the origin of the decreased Mayer wave and fractal dimension. These nonlinear dynamic analyses may be useful to design optimal VAS control.
- 1 January 1999
- Published by Wiley in Artificial Organs
- Vol. 23 (1) , 119-123
Chaotic Dynamics in Circulation with Tohoku University Vibrating Flow Pump
For the development of a totally implantable ventricular assist system (VAS), we have been developing the vibrating flow pump (VFP), which can generate oscillated blood flow with a relative high frequency (10–50 Hz) for a totally implantable system. In this study, the effects of left ventricular assistance with this unique oscillated blood flow were analyzed by the use of nonlinear mathematics for evaluation as the whole circulatory regulatory system, not as the decomposed parts of the system. Left heart bypasses using the VFP from the left atrium to the descending aorta were performed in chronic animal experiments using healthy adult goats. The ECG, arterial blood pressure, VFP pump flow, and the flow of the descending aorta were recorded in the data recorder during awake conditions and analyzed in a personal computer system through an A–D convertor. By the use of nonlinear mathematics, time series data were embedded into the phase space, the Lyapunov numerical method, fractal dimension analysis, and power spectrum analysis were performed to evaluate nonlinear dynamics. During left ventricular assistance with the VFP, Mayer wave fluctuations were decreased in the power spectrum, the fractal dimension of the hemodynamics was significantly decreased, and peripheral vascular resistance was significantly decreased. These results suggest that nonlinear dynamics, which mediate the cardiovascular dynamics, may be affected during left ventricular (LV) bypass with oscillated flow. The decreased power of the Mayer wave in the spectrum caused the limit cycle attractor of the hemodynamics and decreased peripheral resistance. Decreased sympathetic discharges may be the origin of the decreased Mayer wave and fractal dimension. These nonlinear dynamic analyses may be useful to design optimal VAS control.
- 1 January 1997
- p. 41-3
Development and evaluation of totally implantable ventricular assist system using a vibrating flow pump and transcutaneous energy transmission system with amorphous fibers.
We have developed a vibrating flow pump (VFP) that can generate oscillated blood flow with a relatively high frequency (10-50 Hz) for a totally implantable ventricular assist system (VAS). To evaluate the newly developed VAS, left heart bypasses, using the VFP, were performed in chronic animal experiments. Hemodynamic parameters were recorded in a data recorder in healthy adult goats during an awake condition and analyzed in a personal computer system through an alternating-direct current converter. Basic performance of the total system with a transcutaneous energy transmission system were satisfactory. During left ventricular assistance with the VFP, Mayer wave fluctuations of hemodynamics were decreased in the power spectrum, the fractal dimensions of the hemodynamics were significantly decreased, and peripheral vascular resistance was significantly decreased. These results suggest that cardiovascular regulatory nonlinear dynamics, which mediate the hemodynamics, may be affected by left ventricular bypass with oscillated flow. The decreased power of the Mayer wave in the spectrum caused the limit cycle attractor of the hemodynamics and decreased peripheral resistance. These results suggest that this newly developed VAS is useful for the totally implantable system with unique characteristics that can control hemodynamic properties.
- 1 January 1997
- p. 41-3
Development and evaluation of totally implantable ventricular assist system using a vibrating flow pump and transcutaneous energy transmission system with amorphous fibers.
We have developed a vibrating flow pump (VFP) that can generate oscillated blood flow with a relatively high frequency (10-50 Hz) for a totally implantable ventricular assist system (VAS). To evaluate the newly developed VAS, left heart bypasses, using the VFP, were performed in chronic animal experiments. Hemodynamic parameters were recorded in a data recorder in healthy adult goats during an awake condition and analyzed in a personal computer system through an alternating-direct current converter. Basic performance of the total system with a transcutaneous energy transmission system were satisfactory. During left ventricular assistance with the VFP, Mayer wave fluctuations of hemodynamics were decreased in the power spectrum, the fractal dimensions of the hemodynamics were significantly decreased, and peripheral vascular resistance was significantly decreased. These results suggest that cardiovascular regulatory nonlinear dynamics, which mediate the hemodynamics, may be affected by left ventricular bypass with oscillated flow. The decreased power of the Mayer wave in the spectrum caused the limit cycle attractor of the hemodynamics and decreased peripheral resistance. These results suggest that this newly developed VAS is useful for the totally implantable system with unique characteristics that can control hemodynamic properties.
- 1 June 1996
- Vol. 19 (6) , 367-71
Spectral analysis of hemodynamics during left ventricular assistance.
In order to analyze the autonomic nervous system during left ventricular (LV) assistance, fluctuations in hemodynamic derivatives were evaluated by a spectral analyzing method using a fast fourier transform (FFT) methodology. After the left pleural cavity was opened through the fourth intercostal space under general anesthesia, a pneumatically driven ventricular assist system was implanted as in left heart bypasses in chronic animal experiments, using three healthy adult goats. Hemodynamic parameters with and without LV assistance were recorded on a magnetic tape in the awake condition then analyzed in a computer system through an A-D convertor. Power spectral analysis was performed on a beat-to-beat basis for the evaluation of the fluctuations. During copulsation mode LV assistance, Mayer wave fluctuations (0.1 Hz) were significantly increased compared with counterpulsation mode LV assist, suggesting an increase in sympathetic tone. Co-pulsation mode LV assist is reported to increase the afterload of the natural left ventricle, thus, the sympathetic tone may be increased to maintain a natural heart output.
- 1 June 1996
- Vol. 19 (6) , 367-71
Spectral analysis of hemodynamics during left ventricular assistance.
In order to analyze the autonomic nervous system during left ventricular (LV) assistance, fluctuations in hemodynamic derivatives were evaluated by a spectral analyzing method using a fast fourier transform (FFT) methodology. After the left pleural cavity was opened through the fourth intercostal space under general anesthesia, a pneumatically driven ventricular assist system was implanted as in left heart bypasses in chronic animal experiments, using three healthy adult goats. Hemodynamic parameters with and without LV assistance were recorded on a magnetic tape in the awake condition then analyzed in a computer system through an A-D convertor. Power spectral analysis was performed on a beat-to-beat basis for the evaluation of the fluctuations. During copulsation mode LV assistance, Mayer wave fluctuations (0.1 Hz) were significantly increased compared with counterpulsation mode LV assist, suggesting an increase in sympathetic tone. Co-pulsation mode LV assist is reported to increase the afterload of the natural left ventricle, thus, the sympathetic tone may be increased to maintain a natural heart output.
- 1 June 1996
- Vol. 20 (6) , 637-40
Fluctuations of the hemodynamic derivatives during left ventricular assistance using oscillated blood flow.
To analyze the autonomic nervous system during left heart bypass with a vibrating flow pump (VFP), fluctuations in hemodynamic derivatives were evaluated by the spectral analysis method using fast fourier transform methodology. After the left pleural cavity was opened through the fourth intercostal space under general anesthesia, a VFP was implanted as the left heart bypass device in chronic animal experiments using 3 healthy adult goats. Hemodynamic parameters with and without VFP assistance were recorded on magnetic tape in awake animals and were analyzed by computer through an analog to digital convertor. Power spectral analysis was performed on a beat-to-beat basis for the evaluation of the fluctuations. During left heart bypass with the VFP, Mayer wave fluctuations were decreased significantly although respiratory waves were not changed significantly. These results suggest that sympathetic nervous system modulation was changed under the influences of the left heart bypass with VFP. By using this analysis methodology, truly physiologic ventricular assistance may be achieved.
- 1 June 1996
- Vol. 20 (6) , 637-40
Fluctuations of the hemodynamic derivatives during left ventricular assistance using oscillated blood flow.
To analyze the autonomic nervous system during left heart bypass with a vibrating flow pump (VFP), fluctuations in hemodynamic derivatives were evaluated by the spectral analysis method using fast fourier transform methodology. After the left pleural cavity was opened through the fourth intercostal space under general anesthesia, a VFP was implanted as the left heart bypass device in chronic animal experiments using 3 healthy adult goats. Hemodynamic parameters with and without VFP assistance were recorded on magnetic tape in awake animals and were analyzed by computer through an analog to digital convertor. Power spectral analysis was performed on a beat-to-beat basis for the evaluation of the fluctuations. During left heart bypass with the VFP, Mayer wave fluctuations were decreased significantly although respiratory waves were not changed significantly. These results suggest that sympathetic nervous system modulation was changed under the influences of the left heart bypass with VFP. By using this analysis methodology, truly physiologic ventricular assistance may be achieved.