Peter Helwig
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Peter Helwig has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
N. Südkamp
Department of Orthopaedics and TraumatologyAlbert-Ludwigs-University Freiburg, Hugstetterstr. 55D-79106FreiburgGermany
4 shared publicationsU. Hindenlang
LASSO Ingenieurgesellschaft, Leinfelden-Echterdingen, Germany
4 shared publicationsB. Kröplin
3 shared publicationsC. Bahrs
Berufsgenossenschaftliche Unfallklinik, Eberhard-Karls-University Tuebingen, Germany
3 shared publications- Christoph Eingartner
Berufsgenossenschaftliche Unfallklinik, Tübingen
3 shared publications G. Faust
3 shared publications
Latest Publications
- Open Access
- 7 June 2017
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 18 (1) , 247
Factors influencing treatment success of negative pressure wound therapy in patients with postoperative infections after Osteosynthetic fracture fixation
Negative Pressure Wound Therapy (NPWT) is being increasingly used to treat postoperative infections after osteosynthetic fracture fixation. The aim of the present study was to analyze the influence of epidemiological and microbiological parameters on outcome. Infections following operative fracture fixation were registered in a comprehensive Critical Incidence Reporting System and subsequently analyzed retrospectively for characteristics of patients including comorbidity, bacteria, and clinical factors. The influence of the investigated parameters was analyzed using logistic regression models based on data from 106 patients. Staged wound lavage in combination with NPWT allowed implant preservation in 44% and led to successful healing in 73% of patients. Fermentation characteristics, load and behavior after gram staining revealed no statistically significant correlation with either healing or implant preservation. Infecting bacteria were successfully isolated in 87% of patients. 20% of all infections were caused by bacterial combinations. We observed a change in the infecting bacterial species under therapy in 23%. Age, gender, metabolic diseases or comorbidities did not influence the probability of implant preservation or healing. The delayed manifestation of infection (>4 weeks) correlated with a higher risk for implant loss (OR 5.1 [95% CI 1.41–17.92]) as did the presence of bacterial mixture (OR 5.0 [95% CI 1.41–17.92]) and open soft-tissue damage ≥ grade 3 (OR 10.2 [CI 1.88–55.28]). Wounds were less likely to heal in conjunction with high CRP blood levels (>20 mg/l) at the time of discharge (OR 3.6 [95% CI 1.31–10.08]) or following a change of the infecting bacterial species under therapy (OR 3.2 [95% CI, 1.13–8.99]). These results indicate that the delayed manifestation of infection, high CRP blood levels at discharge, and alterations in the infecting bacterial species under therapy raise the risk of NPWT failure.
- 7 June 2017
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 18 (1) , 247
Open AccessFactors influencing treatment success of negative pressure wound therapy in patients with postoperative infections after Osteosynthetic fracture fixation
Negative Pressure Wound Therapy (NPWT) is being increasingly used to treat postoperative infections after osteosynthetic fracture fixation. The aim of the present study was to analyze the influence of epidemiological and microbiological parameters on outcome. Infections following operative fracture fixation were registered in a comprehensive Critical Incidence Reporting System and subsequently analyzed retrospectively for characteristics of patients including comorbidity, bacteria, and clinical factors. The influence of the investigated parameters was analyzed using logistic regression models based on data from 106 patients. Staged wound lavage in combination with NPWT allowed implant preservation in 44% and led to successful healing in 73% of patients. Fermentation characteristics, load and behavior after gram staining revealed no statistically significant correlation with either healing or implant preservation. Infecting bacteria were successfully isolated in 87% of patients. 20% of all infections were caused by bacterial combinations. We observed a change in the infecting bacterial species under therapy in 23%. Age, gender, metabolic diseases or comorbidities did not influence the probability of implant preservation or healing. The delayed manifestation of infection (>4 weeks) correlated with a higher risk for implant loss (OR 5.1 [95% CI 1.41–17.92]) as did the presence of bacterial mixture (OR 5.0 [95% CI 1.41–17.92]) and open soft-tissue damage ≥ grade 3 (OR 10.2 [CI 1.88–55.28]). Wounds were less likely to heal in conjunction with high CRP blood levels (>20 mg/l) at the time of discharge (OR 3.6 [95% CI 1.31–10.08]) or following a change of the infecting bacterial species under therapy (OR 3.2 [95% CI, 1.13–8.99]). These results indicate that the delayed manifestation of infection, high CRP blood levels at discharge, and alterations in the infecting bacterial species under therapy raise the risk of NPWT failure.
- 7 January 2014
- Published by Springer Nature in International Orthopaedics
- Vol. 38 (5) , 1077-1081
Periprosthetic joint infection—effect on quality of life
Purpose Relatively little is known about the extent to which periprosthetic joint infections (PJI) affect the patient’s long-term quality of life (QoL). Our study aim was to assess the effect of a periprosthetic infection on our patients’ QoL. Methods We collected data retrospectively of patients who had undergone surgery in our institution between 2006 and 2011. To capture their overall QoL, we telephoned the patients who could be reached and asked them the questions on the SF-12 questionnaire. Results In 84 patients (53 male, 31 female, 43 TKA and 41 THA), 88 % of the hip infections and 62 % of the knee infections had been successfully treated. The hip infections’ cure rate was significantly higher than that of the knee joint infections. The average SF-12 score was 36.2 points on the physical scale and 52 on the mental scale. The difference in QoL between patients with and without successful infection therapy was not significant, nor did the site of the infection (knee or hip) influence QoL significantly. Comparison of our patients’ QoL data to that from the general population revealed a significant difference in the physical scale but not the mental scale. Conclusion From these results QoL is substantially reduced after a prosthetic infection. We did however observe that post-Girdelstone procedure patients or those with an arthrodesis attained an acceptable QoL, and that those methods remain therapeutic alternatives as far as patient-perceived QoL is concerned.
- 7 January 2014
- Published by Springer Nature in International Orthopaedics
- Vol. 38 (5) , 1077-1081
Periprosthetic joint infection—effect on quality of life
Purpose Relatively little is known about the extent to which periprosthetic joint infections (PJI) affect the patient’s long-term quality of life (QoL). Our study aim was to assess the effect of a periprosthetic infection on our patients’ QoL. Methods We collected data retrospectively of patients who had undergone surgery in our institution between 2006 and 2011. To capture their overall QoL, we telephoned the patients who could be reached and asked them the questions on the SF-12 questionnaire. Results In 84 patients (53 male, 31 female, 43 TKA and 41 THA), 88 % of the hip infections and 62 % of the knee infections had been successfully treated. The hip infections’ cure rate was significantly higher than that of the knee joint infections. The average SF-12 score was 36.2 points on the physical scale and 52 on the mental scale. The difference in QoL between patients with and without successful infection therapy was not significant, nor did the site of the infection (knee or hip) influence QoL significantly. Comparison of our patients’ QoL data to that from the general population revealed a significant difference in the physical scale but not the mental scale. Conclusion From these results QoL is substantially reduced after a prosthetic infection. We did however observe that post-Girdelstone procedure patients or those with an arthrodesis attained an acceptable QoL, and that those methods remain therapeutic alternatives as far as patient-perceived QoL is concerned.
- 27 October 2013
- Published by Springer Nature in International Orthopaedics
- Vol. 38 (4) , 733-739
Digital templating in total knee and hip replacement: an analysis of planning accuracy
The aim of this study was to determine how well pre-operative size selection for total knee and hip arthroplasties based on the digital imaging with and without additional referencing correlated with the size actually implanted. Size selection planning of total knee arthroplasty by digital templating was documented in 46 cases with reference ball (group A) and in 48 cases without ball (group B). In addition, prospective analysis of pre-operative planning was conducted for 52 acetabular components with reference ball (group C) and 69 without ball (group D) as well as stem planning in 38 cases with ball (group E) and 54 cases without ball (group F). The data were analysed and compared with the size of the final component selected during surgery. The correlation between planned and implanted size for total knee arthroplasty in group A resulted in femoral anteroposterior (AP) r = 0.8622 and lateral r = 0.8333 and in group B AP r = 0.4552 and lateral r = 0.6950. Tibial in group A was AP r = 0.9030 and lateral r = 0.9074 and in group B AP r = 0.7000 and lateral r = 0.6376. For the acetabular components, the results in group C were r = 0.5998 and group D r = 0.6923. For stems, group E was r = 0.5306 and group F r = 0.5786. No correlation between BMI and the difference between planned and implanted size was found in any of the groups. In the case of total hip arthroplasty there was a relatively low correlation between planned and implanted sizes with or without reference ball. For total knee arthroplasties the already high precision of size planning was further improved by the additional referencing with a reference ball.
- 27 October 2013
- Published by Springer Nature in International Orthopaedics
- Vol. 38 (4) , 733-739
Digital templating in total knee and hip replacement: an analysis of planning accuracy
The aim of this study was to determine how well pre-operative size selection for total knee and hip arthroplasties based on the digital imaging with and without additional referencing correlated with the size actually implanted. Size selection planning of total knee arthroplasty by digital templating was documented in 46 cases with reference ball (group A) and in 48 cases without ball (group B). In addition, prospective analysis of pre-operative planning was conducted for 52 acetabular components with reference ball (group C) and 69 without ball (group D) as well as stem planning in 38 cases with ball (group E) and 54 cases without ball (group F). The data were analysed and compared with the size of the final component selected during surgery. The correlation between planned and implanted size for total knee arthroplasty in group A resulted in femoral anteroposterior (AP) r = 0.8622 and lateral r = 0.8333 and in group B AP r = 0.4552 and lateral r = 0.6950. Tibial in group A was AP r = 0.9030 and lateral r = 0.9074 and in group B AP r = 0.7000 and lateral r = 0.6376. For the acetabular components, the results in group C were r = 0.5998 and group D r = 0.6923. For stems, group E was r = 0.5306 and group F r = 0.5786. No correlation between BMI and the difference between planned and implanted size was found in any of the groups. In the case of total hip arthroplasty there was a relatively low correlation between planned and implanted sizes with or without reference ball. For total knee arthroplasties the already high precision of size planning was further improved by the additional referencing with a reference ball.
- 1 June 2013
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 16 (6) , 669-677
A femoral model with all relevant muscles and hip capsule ligaments
In order to evaluate stabilisation systems in trochanteric femoral fractures with finite element (FE) analysis, a realistic model is required. For this purpose, a new model of a femur with all the relevant muscles and the hip capsule ligaments is set up. The pelvic and tibial bones are modelled as rigid bodies so as to take all the muscles attached to the femur into account. Fracture zones in the proximal femur are defined. Following the modelling of the geometry, the isotropic material behaviour and the load application, a numerical calculation of the femur is carried out. The static iterated FE simulation shows good agreement with in vivo data for the one-leg-stance phase during walking and Pauwels' one-leg stance regarding the displacement of the femoral head (2.9 and 5.2 mm, respectively) and the resulting hip force (253% and 294% bodyweight, respectively). In the modelled fracture zones without osteosynthesis, shear is higher than axial strain. The reduction of shear among others could be a criterion for judging the quality of a stabilisation implant.
- 1 June 2013
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 16 (6) , 669-677
A femoral model with all relevant muscles and hip capsule ligaments
In order to evaluate stabilisation systems in trochanteric femoral fractures with finite element (FE) analysis, a realistic model is required. For this purpose, a new model of a femur with all the relevant muscles and the hip capsule ligaments is set up. The pelvic and tibial bones are modelled as rigid bodies so as to take all the muscles attached to the femur into account. Fracture zones in the proximal femur are defined. Following the modelling of the geometry, the isotropic material behaviour and the load application, a numerical calculation of the femur is carried out. The static iterated FE simulation shows good agreement with in vivo data for the one-leg-stance phase during walking and Pauwels' one-leg stance regarding the displacement of the femoral head (2.9 and 5.2 mm, respectively) and the resulting hip force (253% and 294% bodyweight, respectively). In the modelled fracture zones without osteosynthesis, shear is higher than axial strain. The reduction of shear among others could be a criterion for judging the quality of a stabilisation implant.
- 7 December 2012
- Published by Springer Nature in International Orthopaedics
- Vol. 37 (1) , 15-19
Modular sleeves with ceramic heads in isolated acetabular cup revision in younger patients—laboratory and experimental analysis of suitability and clinical outcomes
One possibility in hip arthroplasty revisions is to combine a modular ceramic head with an adapter or sleeve in isolated acetabular cup replacement. This study consisted of an experimental part to analyse the reliability of taper damage predictions, and a clinical part to analyse the outcomes of modular ceramic head implantation in a case series of isolated cup replacements. Analysis of scratch size on 11 explanted hip stems were examined macroscopically and by stereomicroscopy to classify damage to the conical taper. The second part consisted of a prospective analysis of isolated cup revisions using a modular ceramic head, performed in two orthopedic centres. Analysis of scratch size on the taper yielded inter-observer correlations of 0.545–0.909; comparison with stereomicroscopic data recordings yielded a moderate correlation, with values between 0.545 and 0.090. The clinical study included 47 isolated acetabular cup revisions involving modular ceramic heads. Ceramic head failure did not occur during the average clinical and radiological observation period of 26 months. Mean Harris Hip Score (HHS) at follow-up was 70 points. From these results, it can be concluded that damage to the implanted stem taper cannot be reliably predicted intraoperatively. Nevertheless, the clinical outcomes did show that there were no problems with the ceramic heads over the short observation period. The application of modular ceramic heads in younger patients requiring isolated cup replacement requires proper risk-benefit analysis, but is possible and appears to be a safe procedure.
- 7 December 2012
- Published by Springer Nature in International Orthopaedics
- Vol. 37 (1) , 15-19
Modular sleeves with ceramic heads in isolated acetabular cup revision in younger patients—laboratory and experimental analysis of suitability and clinical outcomes
One possibility in hip arthroplasty revisions is to combine a modular ceramic head with an adapter or sleeve in isolated acetabular cup replacement. This study consisted of an experimental part to analyse the reliability of taper damage predictions, and a clinical part to analyse the outcomes of modular ceramic head implantation in a case series of isolated cup replacements. Analysis of scratch size on 11 explanted hip stems were examined macroscopically and by stereomicroscopy to classify damage to the conical taper. The second part consisted of a prospective analysis of isolated cup revisions using a modular ceramic head, performed in two orthopedic centres. Analysis of scratch size on the taper yielded inter-observer correlations of 0.545–0.909; comparison with stereomicroscopic data recordings yielded a moderate correlation, with values between 0.545 and 0.090. The clinical study included 47 isolated acetabular cup revisions involving modular ceramic heads. Ceramic head failure did not occur during the average clinical and radiological observation period of 26 months. Mean Harris Hip Score (HHS) at follow-up was 70 points. From these results, it can be concluded that damage to the implanted stem taper cannot be reliably predicted intraoperatively. Nevertheless, the clinical outcomes did show that there were no problems with the ceramic heads over the short observation period. The application of modular ceramic heads in younger patients requiring isolated cup replacement requires proper risk-benefit analysis, but is possible and appears to be a safe procedure.
- Open Access
- 2 April 2009
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 10 (1) , 33
Indications for computed tomography (CT-) diagnostics in proximal humeral fractures: a comparative study of plain radiography and computed tomography
Background: Precise indications for computed tomography (CT) in proximal humeral fractures are not established. The purpose of this study was a comparison of conventional radiographic views with different CT reconstructions with 2 D and 3 D imaging to establish indications for additional CT diagnostics depending on the fractured parts. Methods: In a prospective diagnostic study in two level 1 trauma centers, 44 patients with proximal humeral fractures were diagnosed with conventional X-rays (22 AP + axillary views, 22 AP + scapular Y-views) and CT (multi-planar reconstruction (MPR) and maximum intensity projection (MIP)) with 2 D and 3 D imaging. 3 observers assessed the technical image quality, the assessment of the relevant anatomical structures (2-sample-t-test) and the percentage of the osseous overlap of the proximal humerus (Welch-test) using a scoring system. The quality of the different diagnostic methods was assessed according to the number of fractured parts (Bonferroni-Holm adjustment). Results: There was significantly more overlap of the fractured region on the scapular Y-views (mean 71.5%, range 45–90%) than on axillary views (mean 56.2%, range 10.5–100%). CT-diagnostics allowed a significantly better assessment of the relevant structures than conventional diagnostics (p < 0.05) independently of the fracture severity (two-, three-, and four-part fractures). Conclusion: Conventional X-rays with AP view and a high-quality axillary view are useful for primary diagnostics of the fracture and often but not always show a clear presentation of the relevant bony structures such as both tuberosities, the glenoid and humeral head. CT with thin slices technology and additional 3 D imaging provides always a clear presentation of the fractured region. Clinically, a CT should be performed – independently of the number of fractured parts – when the proximal humerus and the shoulder joint are not presented with sufficient X-ray-quality to establish a treatment plan.
- 2 April 2009
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 10 (1) , 33
Open AccessIndications for computed tomography (CT-) diagnostics in proximal humeral fractures: a comparative study of plain radiography and computed tomography
Background: Precise indications for computed tomography (CT) in proximal humeral fractures are not established. The purpose of this study was a comparison of conventional radiographic views with different CT reconstructions with 2 D and 3 D imaging to establish indications for additional CT diagnostics depending on the fractured parts. Methods: In a prospective diagnostic study in two level 1 trauma centers, 44 patients with proximal humeral fractures were diagnosed with conventional X-rays (22 AP + axillary views, 22 AP + scapular Y-views) and CT (multi-planar reconstruction (MPR) and maximum intensity projection (MIP)) with 2 D and 3 D imaging. 3 observers assessed the technical image quality, the assessment of the relevant anatomical structures (2-sample-t-test) and the percentage of the osseous overlap of the proximal humerus (Welch-test) using a scoring system. The quality of the different diagnostic methods was assessed according to the number of fractured parts (Bonferroni-Holm adjustment). Results: There was significantly more overlap of the fractured region on the scapular Y-views (mean 71.5%, range 45–90%) than on axillary views (mean 56.2%, range 10.5–100%). CT-diagnostics allowed a significantly better assessment of the relevant structures than conventional diagnostics (p < 0.05) independently of the fracture severity (two-, three-, and four-part fractures). Conclusion: Conventional X-rays with AP view and a high-quality axillary view are useful for primary diagnostics of the fracture and often but not always show a clear presentation of the relevant bony structures such as both tuberosities, the glenoid and humeral head. CT with thin slices technology and additional 3 D imaging provides always a clear presentation of the fractured region. Clinically, a CT should be performed – independently of the number of fractured parts – when the proximal humerus and the shoulder joint are not presented with sufficient X-ray-quality to establish a treatment plan.
- 25 April 2008
- Published by Springer Nature in Der Orthopäde
- Vol. 37 (5) , 470-474
Therapieoption perioperativer Blutungskomplikationen
- 25 April 2008
- Published by Springer Nature in Der Orthopäde
- Vol. 37 (5) , 470-474
Therapieoption perioperativer Blutungskomplikationen
- 31 December 2006
- Published by Elsevier in Journal of Biomechanics
- Vol. 39, S455
Finite element analysis of a new proximal femoral nail (PFN-A)
- 31 December 2006
- Published by Elsevier in Journal of Biomechanics
- Vol. 39, S455
Finite element analysis of a new proximal femoral nail (PFN-A)