MRMark Rosenfield

Mark Rosenfield

*This is an algorithmically generated author record based on publicly available information.

Mark Rosenfield has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Cognitive demand, concurrent viewing distances, and digital eyestrain

    by Elianna Od Sharvit, Mark MCOptom Rosenfield

    SIGNIFICANCE: Digital devices are ubiquitous in modern daily life. Although a high prevalence of digital eyestrain has been reported, the mechanisms underlying digital eyestrain have not been fully elucidated, and there is currently no proven treatment. PURPOSE: This study aimed to evaluate the relationship between the cognitive demand of a near task, mode of presentation (digital or paper), working distance, and symptoms of digital eyestrain. METHODS: Thirty young participants completed four 30‐minute reading tasks. The four conditions (performed in randomized order) entailed (1) a cognitively demanding task performed on a tablet computer and (2) a less cognitively demanding task performed on the same device. Trials (3) and (4) were identical to (1) and (2) except that the tasks were performed on paper. Subjects could hold the reading task at any distance they felt comfortable. Before and immediately following each task, subjects completed a digital eyestrain symptom survey. For all four conditions, a spectacle‐mounted device (Clouclip) was used to measure the working distance objectively. RESULTS: Although all four tasks induced significant symptoms, there was a significant difference between the four conditions, with the increase being greatest for the cognitively demanding task on the tablet computer. There was no significant difference in working distance for the four conditions, and all tasks showed a similar reduction in working distance (p=0.001), on average, from 31.6 to 28.9 cm, over the first 10 minutes, with the working distance remaining stable after this initial period. CONCLUSIONS: Task‐induced symptoms varied with both cognitive demand and mode of presentation. However, working distance did not vary significantly with these factors. The wording distance decreased during the first 10 minutes of each trial and was markedly closer than 40 cm for all conditions. The closer working distances being adopted should be considered during routine clinical testing.


  • Objective and subjective assessment of accommodative insufficiency

    by Alejandro Od León, Mark MCOptom Rosenfield, Sandra Milena Od Medrano, Sandra Carolina Od Durán, Carol Violet Od Pinzón

    SIGNIFICANCE: A variety of subjective and objective procedures are available to measure the amplitude of accommodation. However, it is unclear whether the standard criterion of Hofstetter's minimum minus 2 D can be used to diagnose accommodative insufficiency with each of these techniques. PURPOSE: The use of objective dynamic retinoscopy and three subjective techniques to diagnosis accommodative insufficiency was examined. METHODS: A total of 632 subjects between 8 and 19 years of age were enrolled. Accommodative lag, monocular accommodative facility, and subjective (push‐up, modified push‐down, and minus lens) and objective (dynamic retinoscopy) amplitude of accommodation were quantified. Accommodative insufficiency was diagnosed based on Hofstetter's minimum minus 2 D for each subjective method, as well as adding an additional subjective criterion (either accommodative lag exceeding 0.75 D or monocular accommodative facility falling below the age‐expected norms). RESULTS: The prevalence of accommodative insufficiency was lowest and highest with the push‐up (7.9 and 1%) and dynamic retinoscopy (94 and 12%) procedures when measured without and with the additional subjective criteria, respectively. Comparing the validity of dynamic retinoscopy against the traditional criterion, moderate to low sensitivity and high specificity were found. However, adding the additional subjective criteria improved the findings with moderate to high sensitivity and high specificity. Using a cutoff for dynamic retinoscopy of 7.50 D showed moderate diagnostic accuracy based on likelihood ratios. CONCLUSIONS: It is clear that a revised definition of accommodative insufficiency is required, which must include the method of assessing accommodation. The various objective and subjective methods for quantifying the amplitude of accommodation are not interchangeable, and subjective assessment does not provide a valid measure of the accommodative response.


  • Authors' Response

    by Mark MCOptom Rosenfield, Sophia Bs Johnson

  • 20‐20‐20 Rule: Are These Numbers Justified?

    by Sophia Bs Johnson, Mark MCOptom Rosenfield

    SIGNIFICANCE: The use of digital devices has increased substantially in recent years across all age groups for both vocational and avocational purposes. There are a wide range of proposed therapeutic and management options for this condition, including optical, medical, and ergonomic interventions. PURPOSE: Regular breaks are frequently recommended by clinicians to minimize digital eye strain. The so‐called 20‐20‐20 rule, whereby individuals are advised to fixate on an object at least 20 feet (6 m) away for at least 20 seconds every 20 minutes is widely cited. Unfortunately, there is relatively little peer‐reviewed evidence to support this rule. The aim of this investigation was to determine whether scheduled breaks are effective in reducing the adverse effects of digital device usage. METHODS: The study was carried out on 30 young subjects who performed a 40‐minute, cognitively demanding reading task from a tablet computer. The task required them to read random words and to identify which ones began with a specific letter chosen by the experimenter. The task was undertaken on four separate occasions, with 20‐second breaks being allowed every 5, 10, 20, or 40 minutes (i.e., no break), respectively. Both before and after each trial, subjects completed a questionnaire regarding ocular and visual symptoms experienced during the session. In addition, both reading speed and task accuracy were quantified during each trial. RESULTS: A significant increase in post‐task symptoms (with respective to the pre‐task value) was observed for all four trials ( P <. 001). However, there was no significant effect of scheduled breaks on reported symptoms ( P =. 70), reading speed ( P =. 93), or task accuracy ( P =. 55). CONCLUSIONS: Although widely cited as a treatment option, these results do not support the proposal of using 20‐second scheduled breaks as a therapeutic intervention for digital eye strain.


  • Digital Eyestrain and the Critical Fusion Frequency

    by Keying Od Yan, Mark MCOptom Rosenfield

    SIGNIFICANCE: Although the high prevalence of digital eyestrain has been well established, to date, there is no objective measurement of this condition. Previous studies have suggested that digital eyestrain may be associated with decreased critical fusion frequency, but the published evidence to support this association is sparse. PURPOSE: This study sought to determine whether symptoms of digital eyestrain after a sustained computer task are indeed associated with changes in critical fusion frequency. METHODS: The experiment was performed on 30 young visual‐normal subjects. They attended two sessions, during which they undertook a 20‐minute reading task. This comprised either reading random words from a tablet computer or a story from a printed children's book. Critical fusion frequency was measured both before and immediately after each of the reading tasks. In addition, the level of digital eyestrain was assessed by subjects completing a questionnaire regarding ocular and visual symptoms experienced during each of the reading trials. RESULTS: The mean increase in digital eyestrain symptoms after the digital and printed conditions was 11.37 (standard error of the mean [SEM], 2.23) and 4.40 (SEM, 1.34), respectively. Both the post‐task symptom change ( P <. 001) and the difference between the two reading conditions ( P =. 004) were significant. The mean change in critical fusion frequency after the digital and printed conditions was −0.42 (SEM, 0.25) and −0.72 (SEM, 0.26), respectively. Neither the post‐task change nor the difference between the two reading conditions was significant. In addition, when considering the digital condition only, no significant correlation was observed between the changes in critical fusion frequency and reported symptoms. CONCLUSIONS: These results do not support the proposal that changes in critical fusion frequency can be used as an objective measure of eyestrain or other symptoms of digital eyestrain.


  • Open Access

    Validity of Techniques to Evaluate Near Phoria

    by Jaime Bernal Escalante, Mark Rosenfield, Elizabeth Casillas Casillas, Luis Fernando Barba Gallardo, Sergio Ramírez González

    Background: While a number of previous studies have investigated the repeatability of techniques designed to measure heterophoria, there have been few studies of their validity. Accordingly, the present study examined the ability of 3 standard techniques; Von Graefe (VG), Maddox Rod (MR) and Modified Thorington (MT) tests to quantify a known change in heterophoria. Methods:The study was performed on 30 young subjects using each of the 3 procedures listed above. Near (40 cm) heterophoria was quantified both without and with an additional base-out prism. Five possible values were available, namely 2, 4, 6, 8 and 9Δ. After a period of 24 hours, the heterophoria measurement was repeated using the same technique with one of these prisms added to the refractive correction. Results:The mean heterophoria value measured before the introduction of prism using the VG procedure was significantly more exophoric than the findings obtained using the other 2 techniques (p = 0.035). No significant difference was observed between the measured and predicted change in heterophoria following the introduction of the prism for the VG and MT procedures, but a significant difference was found with the MR technique (p0.001). Conclusions:The ability to measure a known change in oculomotor deviation was significantly poorer with the MR technique, when compared with the VG and MT procedures. Given that the mean pre-prism measurement was significantly more exophoric when using the VG procedure, we recommend that MT be adopted as the technique of choice for the subjective measurement of oculomotor deviations in the clinical setting

  • Blue‐blocking Filters and Digital Eyestrain

    by Tatsiana Palavets, Mark Rosenfield

    Supplemental digital content is available in the text. SIGNIFICANCE: Many manufacturers are currently marketing blue‐blocking (BB) filters, which they claim will reduce the symptoms of digital eyestrain (DES). However, there is limited evidence to support the proposal that DES results from the blue light emitted by these devices. PURPOSE: The visual and ocular symptoms commonly experienced when viewing digital screens are collectively termed DES. The emission spectrum of modern digital displays frequently includes a high percentage of blue light. Being higher in energy, these short wavelengths may contribute to DES. This study examined the effect of a BB filter on symptoms of DES during a sustained near‐vision task. METHODS: Twenty‐three young, visually normal subjects were required to perform a 30‐minute reading task from a tablet computer. The digital screen was overlaid with either a BB or neutral‐density (ND) filter producing equal screen luminance. During each session, the accommodative response, pupil diameter, and vertical palpebral aperture dimension were measured at 0, 9, 19, and 29 minutes after the start of the reading task. Immediately following each session, subjects completed a questionnaire to quantify symptoms of DES. RESULTS: The BB filter blocked 99% of the wavelengths between 400 and 500 nm. The mean total symptom scores (±1 SEM) for the BB and ND filter conditions were 42.83 (3.58) and 42.61 (3.17), respectively ( P =. 62). No significant differences in accommodation or vertical palpebral aperture dimension were observed between the two filter conditions, although the magnitude of the mean accommodative response did increase significantly during the first 9 minutes of the task ( P =. 02). CONCLUSIONS: A filter that eliminated 99% of the emitted blue light was no more effective at reducing symptoms of DES than an equiluminant ND filter. There is little evidence at this time to support the use of BB filters to minimize near work–induced asthenopia.


  • Reading from electronic devices versus hardcopy text

    by Jennifer E. Hue, Mark Rosenfield, Gianinna Saá

    BACKGROUND: The use of electronic reading devices has increased dramatically. However, some individuals report increased visual symptoms when reading from electronic screens. OBJECTIVE: This investigation compared reading from two electronic devices (Amazon Kindle or Apple Ipod) versus hardcopy text in two groups of 20 subjects. METHODS: Subjects performed a 20 min reading task for each condition. Both the accommodative response and reading rate were monitored during the trial. Immediately post-task, subjects completed a questionnaire concerning the ocular symptoms experienced during the task. RESULTS: In comparing the Kindle with hardcopy, no significant difference in the total symptom score was observed, although the mean score for the symptoms of tired eyes and eye discomfort was significantly higher with the Kindle. No significant differences in reading rate were found. When comparing the Ipod with hardcopy, no significant differences in symptom scores were found. The mean reading rate with the Ipod was significantly slower than for hardcopy while the mean lag of accommodation was significantly larger for the Ipod. CONCLUSIONS: Given the significant increase in symptoms with the Kindle, and larger lag of accommodation and reduced reading rate with the Ipod, one may conclude that reading from electronic devices is not equivalent to hardcopy.


  • Blur Adaptation in Myopes

    by MARK MCOptom ROSENFIELD, Susan E. Hong, Sini George

    It has been suggested that when subjects with myopia remove their refractive correction, blur adaptation develops to produce an improvement in their visual resolution. The present study measured visual acuity (VA) using high contrast letters and gratings with contrast levels between 2.5% and 40% at 30‐minute intervals over the course of a 3‐h period during which the subjects remained uncorrected. Twenty‐two young subjects with moderate degrees of myopia (mean refractive error, −1.85 D) participated in the study. Immediately after a 1‐h period of full correction, subjects spent 3 h without any refractive correction, during which time they watched television and videos at a viewing distance of 5 m. A significant change in letter and grating VA was observed during the course of the 3‐h period of sustained blur, with the mean uncorrected letter VA improving from 0.76 (SD, ±0.26) to 0.53 (SD, ±0.23) logarithm of the minimum angle of resolution (logMAR). The Snellen equivalent to this change is from 6/35 to 6/20. A significant improvement in grating acuity was also observed. However, no significant change in refractive error, measured using noncycloplegic autorefraction, was found. These results demonstrate significant blur adaptation in subjects with uncorrected myopia, which does not result from a change in refractive state. We hypothesize that the improvement in visual resolution results from perceptual adaptation to the blurred image, which may occur at central sites within the visual cortex.


  • Blur Adaptation and Myopia

    by Sini Ba George, MARK MCOptom ROSENFIELD

    Previous studies have demonstrated a significant improvement in visual resolution during sustained periods of retinal defocus. This appears to result from perceptual adaptation designed to restore the perceived contrast of the degraded image. However, it is unclear whether perceptual adaptation to sustained blur is present in all individuals or only in certain subgroups, such as those who have been chronically exposed to sustained periods of blur due to uncorrected ametropia. Accordingly, the present study examined the effects of sustained retinal defocus on both high-and low-contrast visual acuity in emmetropes (n = 13) and myopes (n = 18). Subjects were required to view through +2.50-D spherical lenses worn over their distance refractive correction for a continuous 2-hour period. A significant improvement in both Landolt C and grating visual acuity measured through the fogging lenses was observed in both refractive groups. Although the mean change in grating visual acuity was significantly greater for the myopic subjects, the improvements in Landolt C acuity observed in the emmetropes and myopes were statistically equivalent. We hypothesize that the improvement in visual acuity results from perceptual adaptation to the blurred images, which may occur at central sites within the visual cortex.