Makoto Ogura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Makoto Ogura has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Hiroshi Ashida
6 shared publicationsMinoru Obara
6 shared publicationsShunichi Sato
5 shared publicationsHitoshi Wakisaka
4 shared publicationsMaki Uenoyama
3 shared publicationsMiya Ishihara
Department of Medical Engineering, National Defense Medical College, 3‐2, Namiki, Tokorozawa‐shi 359‐0042, Japan
3 shared publications
Latest Publications
- 15 September 2004
- Published by Optica Publishing Group in Optics Letters
- Vol. 29 (18) , 2190
Gene transfer into mammalian cells by use of a nanosecond pulsed laser-induced stress wave: erratum
Coupling between the lowest-loss TE01 modes of two touching hollow-core Bragg fibers is considered with a view to designing a directional coupler. We have found that for fibers with core radii larger than 10 mm one can identify broad frequency ranges in which intermodal coupling strength exceeds supermode radiation losses by an order of magnitude, thus opening the possibility of building a directional coupler. We attribute such unusually strong intermode coupling both to the resonant effects in the intermirror cavity and a proximity interaction between the leaky modes localized in the mirror.
- 15 September 2004
- Published by Optica Publishing Group in Optics Letters
- Vol. 29 (18) , 2190
Gene transfer into mammalian cells by use of a nanosecond pulsed laser-induced stress wave: erratum
Coupling between the lowest-loss TE01 modes of two touching hollow-core Bragg fibers is considered with a view to designing a directional coupler. We have found that for fibers with core radii larger than 10 mm one can identify broad frequency ranges in which intermodal coupling strength exceeds supermode radiation losses by an order of magnitude, thus opening the possibility of building a directional coupler. We attribute such unusually strong intermode coupling both to the resonant effects in the intermirror cavity and a proximity interaction between the leaky modes localized in the mirror.
- 5 March 2004
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 34 (3) , 242-248
In vivo targeted gene transfer in skin by the use of laser‐induced stress waves
Background and Objectives: Much interest has been shown in the use of lasers for nonviral targeted gene transfer, since the spatial characteristics of laser light are quite well defined. The aim of this study was to demonstrate in vivo gene transfer by the use of laser‐induced stress waves (LISWs).Study Design/Materials and Methods: After reporter genes had been intradermally injected to rat skin in vivo, a laser target was placed on the gene‐injected skin. LISWs were generated by the irradiation of an elastic laser target with 532‐nm nanosecond laser pulses of a Q‐switched Nd:YAG laser.Results: Levels of luciferase activities for the skin exposed to LISWs were two orders of magnitude higher than those for the skin injected with naked DNA. Expressions of enhanced green fluorescent protein (EGFP) and β‐galactosidase were observed only in the area that was exposed to LISWs, and in addition, epidermal cells were selectively transfected. No major side effects were observed, and luciferase activity levels as high as 105 RLU per mg of protein were sustained even 5 days after gene transfer.Conclusion: Highly efficient and site‐specific gene transfer can be achieved by applying a few pulses of nanosecond pulsed LISWs to rat skin in vivo. Lasers Surg. Med. 34:242–248, 2004.
- 5 March 2004
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 34 (3) , 242-248
In vivo targeted gene transfer in skin by the use of laser‐induced stress waves
Background and Objectives: Much interest has been shown in the use of lasers for nonviral targeted gene transfer, since the spatial characteristics of laser light are quite well defined. The aim of this study was to demonstrate in vivo gene transfer by the use of laser‐induced stress waves (LISWs).Study Design/Materials and Methods: After reporter genes had been intradermally injected to rat skin in vivo, a laser target was placed on the gene‐injected skin. LISWs were generated by the irradiation of an elastic laser target with 532‐nm nanosecond laser pulses of a Q‐switched Nd:YAG laser.Results: Levels of luciferase activities for the skin exposed to LISWs were two orders of magnitude higher than those for the skin injected with naked DNA. Expressions of enhanced green fluorescent protein (EGFP) and β‐galactosidase were observed only in the area that was exposed to LISWs, and in addition, epidermal cells were selectively transfected. No major side effects were observed, and luciferase activity levels as high as 105 RLU per mg of protein were sustained even 5 days after gene transfer.Conclusion: Highly efficient and site‐specific gene transfer can be achieved by applying a few pulses of nanosecond pulsed LISWs to rat skin in vivo. Lasers Surg. Med. 34:242–248, 2004.
- 1 August 2003
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 42 (Part 2, No) , L977-L979
Delivery of Photosensitizer to Cells by the Stress Wave Induced by a Single Nanosecond Laser Pulse
- 1 August 2003
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 42 (Part 2, No) , L977-L979
Delivery of Photosensitizer to Cells by the Stress Wave Induced by a Single Nanosecond Laser Pulse
- 6 August 2002
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 31 (2) , 136-141
Myocardium tissue ablation with high‐peak‐power nanosecond 1,064‐ and 532‐nm pulsed lasers: Influence of laser‐induced plasma
Background and Objectives: We investigated the mechanism and characteristics of porcine myocardium tissue ablation in vitro with nanosecond 1,064‐ and 532‐nm pulsed lasers at laser intensities up to ≈5.0 GW/cm2. Particular attention was paid to study the influence of the laser‐induced plasma on the ablation characteristics. The applicability of these two lasers to transmyocardial laser revascularization (TMLR) was discussed.Study Design/Materials and Methods: Porcine myocardium tissue samples were irradiated with 1,064‐ and 532‐nm, Q‐switched Nd:YAG laser pulses, and the ablation depths were measured. The temporal profiles of the laser‐induced optical emissions were measured with a biplanar phototube. For the ablated tissue samples, histological analysis was performed with an optical microscope and a polarization microscope.Results: The ablation efficiency at 1,064 nm was higher than that at 532 nm. The ablation threshold at 1,064 nm (≈0.8 GW/cm2) was lower than that at 532 nm (≈1.6 GW/cm2), in spite of the lower absorption coefficient being expected at 1,064 nm. For the 1,064‐nm laser‐ablated tissues, thermal damage was very limited, while damage presumably caused by the mechanical effect was observed in most of the cases. For the 1,064‐nm laser ablation, the ablation threshold was equal to the threshold of the laser‐induced optical emission (≈0.8 GW/cm2), while for the 532‐nm laser ablation, the optical emission threshold (≈2.4 GW/cm2) was higher than the ablation threshold.Conclusions: We considered that for the 1,064‐nm laser ablation, the tissue removal was achieved through a photodisruption process at laser intensities of > ≈0.8 GW/cm2. At laser intensities of >3.0 GW/cm2, however, the ablation efficiency decreased; this can be attributed to the absorption of incoming laser pulses by the plasma. For the 532‐nm laser ablation, the tissue removal was achieved through a photothermal process at laser intensities of >≈1.6 GW/cm2. At laser intensities of >2.4 GW/cm2, a photodisruption process may also contribute to the tissue removal, in addition to a photothermal process. With regard to the ablation rates, the 1,064‐nm laser was more suitable for TMLR than the 532‐nm laser. We concluded that the 1,064‐nm Q‐switched Nd:YAG laser would be a potential candidate for a laser source for TMLR because of possible fiber‐based beam delivery, its compact structure, cost effectiveness, and easy maintenance. Animal trials, however, have to be carried out to evaluate the influence of the tissue damage. Lasers Surg. Med. 31:136–141, 2002.
- 6 August 2002
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 31 (2) , 136-141
Myocardium tissue ablation with high‐peak‐power nanosecond 1,064‐ and 532‐nm pulsed lasers: Influence of laser‐induced plasma
Background and Objectives: We investigated the mechanism and characteristics of porcine myocardium tissue ablation in vitro with nanosecond 1,064‐ and 532‐nm pulsed lasers at laser intensities up to ≈5.0 GW/cm2. Particular attention was paid to study the influence of the laser‐induced plasma on the ablation characteristics. The applicability of these two lasers to transmyocardial laser revascularization (TMLR) was discussed.Study Design/Materials and Methods: Porcine myocardium tissue samples were irradiated with 1,064‐ and 532‐nm, Q‐switched Nd:YAG laser pulses, and the ablation depths were measured. The temporal profiles of the laser‐induced optical emissions were measured with a biplanar phototube. For the ablated tissue samples, histological analysis was performed with an optical microscope and a polarization microscope.Results: The ablation efficiency at 1,064 nm was higher than that at 532 nm. The ablation threshold at 1,064 nm (≈0.8 GW/cm2) was lower than that at 532 nm (≈1.6 GW/cm2), in spite of the lower absorption coefficient being expected at 1,064 nm. For the 1,064‐nm laser‐ablated tissues, thermal damage was very limited, while damage presumably caused by the mechanical effect was observed in most of the cases. For the 1,064‐nm laser ablation, the ablation threshold was equal to the threshold of the laser‐induced optical emission (≈0.8 GW/cm2), while for the 532‐nm laser ablation, the optical emission threshold (≈2.4 GW/cm2) was higher than the ablation threshold.Conclusions: We considered that for the 1,064‐nm laser ablation, the tissue removal was achieved through a photodisruption process at laser intensities of > ≈0.8 GW/cm2. At laser intensities of >3.0 GW/cm2, however, the ablation efficiency decreased; this can be attributed to the absorption of incoming laser pulses by the plasma. For the 532‐nm laser ablation, the tissue removal was achieved through a photothermal process at laser intensities of >≈1.6 GW/cm2. At laser intensities of >2.4 GW/cm2, a photodisruption process may also contribute to the tissue removal, in addition to a photothermal process. With regard to the ablation rates, the 1,064‐nm laser was more suitable for TMLR than the 532‐nm laser. We concluded that the 1,064‐nm Q‐switched Nd:YAG laser would be a potential candidate for a laser source for TMLR because of possible fiber‐based beam delivery, its compact structure, cost effectiveness, and easy maintenance. Animal trials, however, have to be carried out to evaluate the influence of the tissue damage. Lasers Surg. Med. 31:136–141, 2002.
- 9 July 2001
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4257, 312-317
Channeling in myocardium tissue through nanosecond pulsed laser photodisruption at visible and near-infrared wavelengths
We investigated in vitro the mechanism of myocardium tissue ablation with nanosecond pulsed laser at the visible and near-infrared wavelengths. In experiments, porcine myocardium tissue was used as sample. It was found that the ablation rate at 1064 nm was larger than that at 532 nm in spite of lower absorption coefficient at 1064 nm than that at 532 nm for the tissue. During ablation the laser-induced optical emission intensity was measured and it was correlated with the ablation depth. Ablated tissue samples were fixed and stained, and histological analysis was performed with an optical microscope and a polarization microscope. For the 1064-nm laser-ablated tissues thermal damage was very limited, although damage that was presumably caused by mechanical effect was observed. The optical emission intensity during the 1064-nm laser ablation was higher than that during the 532-nm laser ablation at the same laser intensity. And for the 1064-nm laser ablation the ablation threshold was nearly equivalent to the optical emission. Based on these experimental results, we concluded that with the 1064-nm laser light, the tissue removal was achieved through a photodisruption process. Application of 1064-nm, nanosecond pulsed laser photodisruption to transmyocardial laser revascularization (TMLR) was discussed.
- 9 July 2001
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4257, 312-317
Channeling in myocardium tissue through nanosecond pulsed laser photodisruption at visible and near-infrared wavelengths
We investigated in vitro the mechanism of myocardium tissue ablation with nanosecond pulsed laser at the visible and near-infrared wavelengths. In experiments, porcine myocardium tissue was used as sample. It was found that the ablation rate at 1064 nm was larger than that at 532 nm in spite of lower absorption coefficient at 1064 nm than that at 532 nm for the tissue. During ablation the laser-induced optical emission intensity was measured and it was correlated with the ablation depth. Ablated tissue samples were fixed and stained, and histological analysis was performed with an optical microscope and a polarization microscope. For the 1064-nm laser-ablated tissues thermal damage was very limited, although damage that was presumably caused by mechanical effect was observed. The optical emission intensity during the 1064-nm laser ablation was higher than that during the 532-nm laser ablation at the same laser intensity. And for the 1064-nm laser ablation the ablation threshold was nearly equivalent to the optical emission. Based on these experimental results, we concluded that with the 1064-nm laser light, the tissue removal was achieved through a photodisruption process. Application of 1064-nm, nanosecond pulsed laser photodisruption to transmyocardial laser revascularization (TMLR) was discussed.
- 1 February 2000
- Published by SPIE-Intl Soc Optical Eng
- Vol. 3885, 132-138
Characteristics and mechanism of myocardium tissue laser ablation: in-vitro study for transmyocardial laser revascularization
To investigate the optimum laser condition for transmyocardial laser revascularization, ablation characteristics of porcine myocardium tissue have been measured in vitro in the spectral region from UV to near IR (230 - 1064 nm). In experiments, a nanosecond, tunable optical parametric oscillator and a Q-switched Nd:YAG laser (the fundamental band and its 2nd, 3rd, and 4th harmonics) were used for ablation. Measurement of ablation hole depth and diameter, and histological analysis with an optical microscopy were performed. It was found that the ablation efficiency increased and the thermal damage threshold of the tissue decreased with decreasing the wavelength. However, at relatively high fluences (approximately 5 J/cm2), unexpected deep ablation was obtained with a 1064-nm laser light, where not thermal but acoustic damage was observed near the walls of the ablation holes. Because intense laser- induced plasma was observed in this case, the shock wave would contribute to removal and/or damage of the tissue.
- 1 February 2000
- Published by SPIE-Intl Soc Optical Eng
- Vol. 3885, 132-138
Characteristics and mechanism of myocardium tissue laser ablation: in-vitro study for transmyocardial laser revascularization
To investigate the optimum laser condition for transmyocardial laser revascularization, ablation characteristics of porcine myocardium tissue have been measured in vitro in the spectral region from UV to near IR (230 - 1064 nm). In experiments, a nanosecond, tunable optical parametric oscillator and a Q-switched Nd:YAG laser (the fundamental band and its 2nd, 3rd, and 4th harmonics) were used for ablation. Measurement of ablation hole depth and diameter, and histological analysis with an optical microscopy were performed. It was found that the ablation efficiency increased and the thermal damage threshold of the tissue decreased with decreasing the wavelength. However, at relatively high fluences (approximately 5 J/cm2), unexpected deep ablation was obtained with a 1064-nm laser light, where not thermal but acoustic damage was observed near the walls of the ablation holes. Because intense laser- induced plasma was observed in this case, the shock wave would contribute to removal and/or damage of the tissue.