BVBalasubramanian Venkatesh

Balasubramanian Venkatesh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Balasubramanian Venkatesh has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Monitoring Tissue Oxygenation during Resuscitation of Major Burns

    by Balasubramanian Venkatesh, Roseanne Meacher, Michael J. Muller, Thomas J. Morgan, John Fraser

    Because subcutaneous and splanchnic oxygenation indices are sensitive indicators of evolving hemorrhagic shock and adequacy of resuscitation, we postulated that these indices might have an equivalent role in the monitoring of severely burned patients. This observational study was undertaken to examine changes in tissue oxygenation indices during burn resuscitation. Seven patients with major burns (54 ± 21% total body surface area) were studied during the first 36 hours of fluid resuscitation. Silastic tubing was placed in the subcutaneous tissue just beneath both normal skin and deep partial thickness burn. Fiberoptic sensors inserted into the tubing measured subcutaneous oxygen and carbon dioxide tensions in the burnt skin (Po2scb and Pco2scb) and normal skin (Po2scn and Pco2scn) continuously. Gastric intramucosal pH (pHi)and the mucosal CO2 (Pco2m) gap were calculated using gastric tonometers. Mean arterial pressure, arterial pH, lactate, and pHi measurements were obtained for 36 hours. There were no significant differences in mean arterial pressure, arterial pH, or lactate concentrations throughout the study period, whereas indices of tissue oxygenation showed deterioration: pHi decreased from 7.2 ± 0.1 to 6.7 ± 0.3 (p = 0.06), the Pco2m gap increased from 12 ± 17 to 108 ± 123 mm Hg (p < 0.01), Po2scn decreased from 112 ± 18 to 50 ± 11 mm Hg (p < 0.01), Po2scb decreased from 62 ± 23 to 29 ± 16 mm Hg (p < 0.01), Pco2scn increased from 42 ± 4 to 46 ± 10 mm Hg (p = 0.2), and Pco2scb increased from 42 ± 10 to 52 ± 5 mm Hg (p = 0.05). Despite adequate global indices of tissue perfusion after 36 hours of resuscitation, tissue monitoring indicated significant deterioration in the splanchnic circulation and in the normal and burnt skin.


  • Blood in the gastrointestinal tract delays and blunts the PCO2 response to transient mucosal ischaemia

    by B. Venkatesh, T. J. Morgan

    Objective: To determine whether the presence of blood in the gastrointestinal tract impairs the detection of splanchnic mucosal ischaemia by reducing the rate and magnitude of rise in gut luminal PCO2 Design: Prospective observational study Setting: University Research Laboratory Subjects: Four adult male Wistar rats with four controls from a concurrent study Interventions: Four adult male Wistar rats were anaesthetised with sodium pentobarbitone and ventilated with oxygen and isoflurane to an initial PaCO2 of 30–40 torr. Electrochemical-fiberoptic gas sensors inserted into silastic tubing placed in the ileal lumen measured luminal PCO2 at 1-s intervals. Distal aortic pressure was monitored continuously. Six 2-min episodes of aortic hypotension were induced in each rat to a mean pressure of 30 mmHg by intermittent elevation of a silk sling placed around the proximal aorta. Before the last three episodes in each rat 0.75–1.0 ml blood was injected into the ileal lumen via a 25-gauge needle. Four control rats from a concurrent experiment were treated in an identical fashion except that the rats were subjected to five ischaemic episodes, and there was no intraluminal injection of blood, although a 20-gauge cannula was placed in the proximal ileal lumen Measurements and main results: The presence of blood in the lumen significantly decreased the ischaemic ΔPCO2 response from 33 ± 8 to 15 ± 4 torr (P < 0.001) and also significantly increased the peak response time from 188 ± 12 to 227 ± 24 s (P < 0.001). The corresponding measurements in the concurrent controls differed only from the values after blood injection in the experimental group Conclusions: In this animal model the presence of intraluminal blood significantly delayed the rate and the amplitude of luminal PCO2 increases in response to transient ischaemia. This raises questions about the validity of luminal CO2 measurements as an indicator of splanchnic ischaemia in the presence of gastrointestinal haemorrhage.


  • Subcutaneous oxygen tensions provide similar information to ileal luminal CO2 tensions in an animal model of haemorrhagic shock

    by B. Venkatesh, T. J. Morgan, J. Lipman

    Objectives: The cutaneous and splanchnic circulations undergo early vasoconstriction in shock. Methodological problems and insufficient information on subcutaneous carbon dioxide partial pressures limit the usefulness of previous studies on splanchnic and subcutaneous gas tensions in shock. Little comparative data exist on the responses of these tissues to shock and resuscitation. We therefore compared continuous subcutaneous PO2 (PO2sc) and PCO2 (PCO2sc) with simultaneous continuous gut luminal PCO2 (PCO2gi) in an animal model of haemorrhagic shock and resuscitation. Design: Prospective observational study. Setting: Intensive care laboratory in a teaching hospital. Subjects: Five anaesthetised rats. Interventions: Electrochemical-fiberoptic gas sensors inserted into Silastic tubing placed in the subcutaneous tissue and in the ileal lumen measured PCO2sc, PO2sc and PCO2gi continuously in five anaesthetised rats. After steady state conditions, hypotension [mean arterial blood pressure (MAP) 40 mmHg] was induced by controlled haemorrhage. The rats were allowed to remain hypotensive for 15 min and then resuscitated with shed blood and crystalloids. Arterial plasma lactate concentrations were measured at defined periods during the study. Measurements and main results: Hypovolaemia resulted in a significant decrease in PO2sc (P < 0.01) and a significant increase in PCO2gi and PCO2sc (P < 0.05). These values returned to baseline with resuscitation. PO2sc appeared to respond to haemorrhage earlier than PCO2gi and PCO2sc (P = 0.02). PO2sc was inversely correlated with PCO2gi (r 2 0.7, P < 0.001). There were no significant changes in arterial plasma lactate concentrations. Conclusions: In our rat model, subcutaneous oxygen tension provided similar information to ileal luminal PCO2 and was more rapidly responsive than subcutaneous carbon dioxide tensions and arterial lactate during evolving haemorrhagic shock and resuscitation.


  • Open Access

    Cerebrospinal Fluid in Critical Illness

    by B. Venkatesh, P. Scott, M. Ziegenfuss


  • Accuracy of pleural fluid pH and PCO2measurement in a blood gas analyser. Analysis of bias and precision

    by B Venkatesh, R.J Boots, S.C Wallis

    Pleural fluid pH measurements are used in the management of parapneumonic effusions. This study evaluated the accuracy of the pleural fluid pH and PCO2 measurement in a blood gas analyser (BGA) and the error induced by altering the aerobic environment and temperature of sample storage prior to analysis. The pH electrodes in a pH meter and a BGA were initially evaluated using aqueous reference solutions. The accuracy of pH and PCO2 electrodes was then assessed in pleural fluid tonometered to a known PCO2. The effects of aerobic compared to anaerobic storage and storage temperature, 0 degrees C vs 37 degrees C of pleural fluid were evaluated for errors in pH and PCO2 measurement. The BGA and the pH meter measured pleural pH with negligible bias and imprecision (0.01+/-0.01 pH units). The PCO2 measurement bias and imprecision of the BGA was small: 1.8+/-0.57 torr (0.2+/-0.08 kPa) at 2% CO2, 0.1+/-0.93 torr (-0.01+/-0.1 kPa) at 5% CO2 and -3.77+/-0.81 (-0.5+/-0.1 kPa) torr at 10% CO2 level. Aerobic storage resulted in a clinically important overestimation of pleural fluid pH by both the pH meter and the BGA of 0.14-0.16 pH units (p<0.05). No significant differences were detected when storage at 0 degrees C was compared to that at 37 degrees C. A BGA is reliable for pleural fluid pH measurements. Pleural fluid PCO2 measurements in a BGA have a concentration-dependent bias and imprecision. Anaerobic storage of specimens for pleural pH and PCO2 analysis is mandatory.


    • 1 May 1997
      • Vol. 35  (2) , 51-2

    Gastric tonometry--quo vadis?

    by T J Morgan, B Venkatesh, J Lipman