Carey E. Floyd
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Carey E. Floyd has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Joseph Y. Lo
Duke University
7 shared publications - Georgia Tourassi
Oak Ridge National Laboratory, USA
4 shared publications - Anuj J. Kapadia
Oak Ridge National Laboratory
2 shared publications - Alan H. Baydush
Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710, USA
1 shared publication - Alexander S. Crowell
Department of Physics, Duke University and Triangle Universities Nuclear Laboratory, Durham, North Carolina 27708, USA
1 shared publication Amy C Sharma
1 shared publication
Latest Publications
- 18 September 2007
- Published by Wiley in Medical Physics
- Vol. 34 (10) , 3866-3871
Breast cancer detection using neutron stimulated emission computed tomography: Prominent elements and dose requirements
Neutron stimulated emission computed tomography (NSECT) is being developed to noninvasively determine concentrations of trace elements in biological tissue. Studies have shown prominent differences in the trace element concentration of normal and malignant breast tissue. NSECT has the potential to detect these differences and diagnose malignancy with high accuracy with dose comparable to that of a single mammogram. In this study, NSECT imaging was simulated for normal and malignant human breast tissue samples to determine the significance of individual elements in determining malignancy. The normal and malignant models were designed with different elemental compositions, and each was scanned spectroscopically using a simulated 2.5 MeV neutron beam. The number of incident neutrons was varied from 0.5 million to 10 million neutrons. The resulting gamma spectra were evaluated through receiver operating characteristic (ROC) analysis to determine which trace elements were prominent enough to be considered markers for breast cancer detection. Four elemental isotopes (133Cs, 81Br, 79Br, and 87Rb) at five energy levels were shown to be promising features for breast cancer detection with an area under the ROC curve (A(Z)) above 0.85. One of these elements--87Rb at 1338 keV--achieved perfect classification at 10 million incident neutrons and could be detected with as low as 3 million incident neutrons. Patient dose was calculated for each gamma spectrum obtained and was found to range from between 0.05 and 0.112 mSv depending on the number of neutrons. This simulation demonstrates that NSECT has the potential to noninvasively detect breast cancer through five prominent trace element energy levels, at dose levels comparable to other breast cancer screening techniques.
- 18 September 2007
- Published by Wiley in Medical Physics
- Vol. 34 (10) , 3866-3871
Breast cancer detection using neutron stimulated emission computed tomography: Prominent elements and dose requirements
Neutron stimulated emission computed tomography (NSECT) is being developed to noninvasively determine concentrations of trace elements in biological tissue. Studies have shown prominent differences in the trace element concentration of normal and malignant breast tissue. NSECT has the potential to detect these differences and diagnose malignancy with high accuracy with dose comparable to that of a single mammogram. In this study, NSECT imaging was simulated for normal and malignant human breast tissue samples to determine the significance of individual elements in determining malignancy. The normal and malignant models were designed with different elemental compositions, and each was scanned spectroscopically using a simulated 2.5 MeV neutron beam. The number of incident neutrons was varied from 0.5 million to 10 million neutrons. The resulting gamma spectra were evaluated through receiver operating characteristic (ROC) analysis to determine which trace elements were prominent enough to be considered markers for breast cancer detection. Four elemental isotopes (133Cs, 81Br, 79Br, and 87Rb) at five energy levels were shown to be promising features for breast cancer detection with an area under the ROC curve (A(Z)) above 0.85. One of these elements--87Rb at 1338 keV--achieved perfect classification at 10 million incident neutrons and could be detected with as low as 3 million incident neutrons. Patient dose was calculated for each gamma spectrum obtained and was found to range from between 0.05 and 0.112 mSv depending on the number of neutrons. This simulation demonstrates that NSECT has the potential to noninvasively detect breast cancer through five prominent trace element energy levels, at dose levels comparable to other breast cancer screening techniques.
- 26 June 2006
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (14) , 3375-3390
Introduction to neutron stimulated emission computed tomography
Neutron stimulated emission computed tomography (NSECT) is presented as a new technique for in vivo tomographic spectroscopic imaging. A full implementation of NSECT is intended to provide an elemental spectrum of the body or part of the body being interrogated at each voxel of a three-dimensional computed tomographic image. An external neutron beam illuminates the sample and some of these neutrons scatter inelastically, producing characteristic gamma emission from the scattering nuclei. These characteristic gamma rays are acquired by a gamma spectrometer and the emitting nucleus is identified by the emitted gamma energy. The neutron beam is scanned over the body in a geometry that allows for tomographic reconstruction. Tomographic images of each element in the spectrum can be reconstructed to represent the spatial distribution of elements within the sample. Here we offer proof of concept for the NSECT method, present the first single projection spectra acquired from multi-element phantoms, and discuss potential biomedical applications.
- 26 June 2006
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (14) , 3375-3390
Introduction to neutron stimulated emission computed tomography
Neutron stimulated emission computed tomography (NSECT) is presented as a new technique for in vivo tomographic spectroscopic imaging. A full implementation of NSECT is intended to provide an elemental spectrum of the body or part of the body being interrogated at each voxel of a three-dimensional computed tomographic image. An external neutron beam illuminates the sample and some of these neutrons scatter inelastically, producing characteristic gamma emission from the scattering nuclei. These characteristic gamma rays are acquired by a gamma spectrometer and the emitting nucleus is identified by the emitted gamma energy. The neutron beam is scanned over the body in a geometry that allows for tomographic reconstruction. Tomographic images of each element in the spectrum can be reconstructed to represent the spatial distribution of elements within the sample. Here we offer proof of concept for the NSECT method, present the first single projection spectra acquired from multi-element phantoms, and discuss potential biomedical applications.
- 1 November 2004
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 233 (2) , 411-417
Computer-aided Detection in Screening Mammography: Variability in Cues
To evaluate the variability of true-positive and false-positive cues by using a commercially available computer-aided detection (CAD) system for analysis of 50 malignancies in a screening population. Fifty breast cancers detected at screening were analyzed by using a commercially available CAD system. Mean patient age was 62.2 years. Each set of mammograms (craniocaudal and mediolateral oblique views) was digitized and analyzed by the CAD system 10 times. One radiologist compared CAD output with the location of the malignancy at mammography and determined whether each lesion was marked accurately in one mammographic view, both views, or neither. Sensitivity and reproducibility of the CAD system were determined for both case- and image-based analysis. Overall sensitivity of the CAD system when at least one of the two mammographic views was marked correctly (case-base sensitivity) was 82.4%. Sensitivity when each mammographic view was considered separately (image-based sensitivity) was 61.1%. For case-based analysis, variability in true-positive CAD cues was demonstrated for 14 of 50 (28%) cases. For image-based analysis, inconsistency in CAD output was observed in 33 of 100 (33%) mammographic views that contained malignancies detected at screening. However, the CAD system consistently detected 40-43 of the 50 breast cancers in each of the 10 CAD runs. Variability for false-positive marks was significantly greater than that for true-positive marks. Inconsistency was demonstrated for CAD analysis of breast cancers detected at screening. However, the CAD system was reasonably consistent in the overall number of cancers identified from run to run. Greater variability of the CAD system was also demonstrated for false-positive marks, as compared with true-positive marks.
- 1 November 2004
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 233 (2) , 411-417
Computer-aided Detection in Screening Mammography: Variability in Cues
To evaluate the variability of true-positive and false-positive cues by using a commercially available computer-aided detection (CAD) system for analysis of 50 malignancies in a screening population. Fifty breast cancers detected at screening were analyzed by using a commercially available CAD system. Mean patient age was 62.2 years. Each set of mammograms (craniocaudal and mediolateral oblique views) was digitized and analyzed by the CAD system 10 times. One radiologist compared CAD output with the location of the malignancy at mammography and determined whether each lesion was marked accurately in one mammographic view, both views, or neither. Sensitivity and reproducibility of the CAD system were determined for both case- and image-based analysis. Overall sensitivity of the CAD system when at least one of the two mammographic views was marked correctly (case-base sensitivity) was 82.4%. Sensitivity when each mammographic view was considered separately (image-based sensitivity) was 61.1%. For case-based analysis, variability in true-positive CAD cues was demonstrated for 14 of 50 (28%) cases. For image-based analysis, inconsistency in CAD output was observed in 33 of 100 (33%) mammographic views that contained malignancies detected at screening. However, the CAD system consistently detected 40-43 of the 50 breast cancers in each of the 10 CAD runs. Variability for false-positive marks was significantly greater than that for true-positive marks. Inconsistency was demonstrated for CAD analysis of breast cancers detected at screening. However, the CAD system was reasonably consistent in the overall number of cancers identified from run to run. Greater variability of the CAD system was also demonstrated for false-positive marks, as compared with true-positive marks.
- 26 March 2002
- Published by Wiley in Medical Physics
- Vol. 29 (4) , 475-483
Parameter optimization of a computer‐aided diagnosis scheme for the segmentation of microcalcification clusters in mammograms
Our purpose in this study is to develop a parameter optimization technique for the segmentation of suspicious microcalcification clusters in digitized mammograms. In previous work, a computer-aided diagnosis (CAD) scheme was developed that used local histogram analysis of overlapping subimages and a fuzzy rule-based classifier to segment individual microcalcifications, and clustering analysis for reducing the number of false positive clusters. The performance of this previous CAD scheme depended on a large number of parameters such as the intervals used to calculate fuzzy membership values and on the combination of membership values used by each decision rule. These parameters were optimized empirically based on the performance of the algorithm on the training set. In order to overcome the limitations of manual training and rule generation, the segmentation algorithm was modified in order to incorporate automatic parameter optimization. For the segmentation of individual microcalcifications, the new algorithm used a neural network with fuzzy-scaled inputs. The fuzzy-scaled inputs were created by processing the histogram features with a family of membership functions, the parameters of which were automatically extracted from the distribution of the feature values. The neural network was trained to classify feature vectors as either positive or negative. Individual microcalcifications were segmented from positive subimages. After clustering, another neural network was trained to eliminate false positive clusters. A database of 98 images provided training and testing sets to optimize the parameters and evaluate the CAD scheme, respectively. The performance of the algorithm was evaluated with a FROC analysis. At a sensitivity rate of 93.2%, there was an average of 0.8 false positive clusters per image. The results are very comparable with those taken using our previously published rule-based method. However, the new algorithm is more suited to generalize its performance on a larger population, depends on two monotonic outputs making its evaluation much easier and can be trained in an automatic way making practical its application on a large database.
- 26 March 2002
- Published by Wiley in Medical Physics
- Vol. 29 (4) , 475-483
Parameter optimization of a computer‐aided diagnosis scheme for the segmentation of microcalcification clusters in mammograms
Our purpose in this study is to develop a parameter optimization technique for the segmentation of suspicious microcalcification clusters in digitized mammograms. In previous work, a computer-aided diagnosis (CAD) scheme was developed that used local histogram analysis of overlapping subimages and a fuzzy rule-based classifier to segment individual microcalcifications, and clustering analysis for reducing the number of false positive clusters. The performance of this previous CAD scheme depended on a large number of parameters such as the intervals used to calculate fuzzy membership values and on the combination of membership values used by each decision rule. These parameters were optimized empirically based on the performance of the algorithm on the training set. In order to overcome the limitations of manual training and rule generation, the segmentation algorithm was modified in order to incorporate automatic parameter optimization. For the segmentation of individual microcalcifications, the new algorithm used a neural network with fuzzy-scaled inputs. The fuzzy-scaled inputs were created by processing the histogram features with a family of membership functions, the parameters of which were automatically extracted from the distribution of the feature values. The neural network was trained to classify feature vectors as either positive or negative. Individual microcalcifications were segmented from positive subimages. After clustering, another neural network was trained to eliminate false positive clusters. A database of 98 images provided training and testing sets to optimize the parameters and evaluate the CAD scheme, respectively. The performance of the algorithm was evaluated with a FROC analysis. At a sensitivity rate of 93.2%, there was an average of 0.8 false positive clusters per image. The results are very comparable with those taken using our previously published rule-based method. However, the new algorithm is more suited to generalize its performance on a larger population, depends on two monotonic outputs making its evaluation much easier and can be trained in an automatic way making practical its application on a large database.
- 11 December 2001
- Published by Wiley in Medical Physics
- Vol. 28 (12) , 2403-2409
Computerized classification of suspicious regions in chest radiographs using subregion Hotelling observers
We propose to investigate the use of subregion Hotelling observers (SRHOs) in conjunction with perceptrons for the computerized classification of suspicious regions in chest radiographs for being nodules requiring follow up. Previously, 239 regions of interest (ROIs), each containing a suspicious lesion with proven classification, were collected. We chose to investigate the use of SRHOs as part of a multilayer classifier to determine the presence of a nodule. Each SRHO incorporates information about signal, background, and noise correlation for classification. For this study, 225 separate Hotelling observers were set up in a grid across each ROI. Each separate observer discriminates an 8 by 8 pixel area. A round robin sampling scheme was used to generate the 225 features, where each feature is the output of the individual observers. These features were then rank ordered by the magnitude of the weights of a perceptron. Once rank ordered, subsets of increasing number of features were selected to be used in another perceptron. This perceptron was trained to minimize mean squared error and the output was a continuous variable representing the likelihood of the region being a nodule. Performance was evaluated by receiver operating characteristic (ROC) analysis and reported as the area under the curve (Az). The classifier was optimized by adding additional features until the Az declined. The optimized subset of observers then were combined using a third perceptron. A subset of 80 features was selected which gave an Az of 0.972. Additionally, at 98.6% sensitivity, the classifier had a specificity of 71.3% and increased the positive predictive value from 60.7% to 84.1 %. Preliminary results suggest that using SRHOs in combination with perceptrons can provide a successful classification scheme for pulmonary nodules. This approach could be incorporated into a larger computer aided detection system for decreasing false positives.
- 11 December 2001
- Published by Wiley in Medical Physics
- Vol. 28 (12) , 2403-2409
Computerized classification of suspicious regions in chest radiographs using subregion Hotelling observers
We propose to investigate the use of subregion Hotelling observers (SRHOs) in conjunction with perceptrons for the computerized classification of suspicious regions in chest radiographs for being nodules requiring follow up. Previously, 239 regions of interest (ROIs), each containing a suspicious lesion with proven classification, were collected. We chose to investigate the use of SRHOs as part of a multilayer classifier to determine the presence of a nodule. Each SRHO incorporates information about signal, background, and noise correlation for classification. For this study, 225 separate Hotelling observers were set up in a grid across each ROI. Each separate observer discriminates an 8 by 8 pixel area. A round robin sampling scheme was used to generate the 225 features, where each feature is the output of the individual observers. These features were then rank ordered by the magnitude of the weights of a perceptron. Once rank ordered, subsets of increasing number of features were selected to be used in another perceptron. This perceptron was trained to minimize mean squared error and the output was a continuous variable representing the likelihood of the region being a nodule. Performance was evaluated by receiver operating characteristic (ROC) analysis and reported as the area under the curve (Az). The classifier was optimized by adding additional features until the Az declined. The optimized subset of observers then were combined using a third perceptron. A subset of 80 features was selected which gave an Az of 0.972. Additionally, at 98.6% sensitivity, the classifier had a specificity of 71.3% and increased the positive predictive value from 60.7% to 84.1 %. Preliminary results suggest that using SRHOs in combination with perceptrons can provide a successful classification scheme for pulmonary nodules. This approach could be incorporated into a larger computer aided detection system for decreasing false positives.
- 16 May 2001
- Published by Wiley in Medical Physics
- Vol. 28 (5) , 804-811
A neural network approach to breast cancer diagnosis as a constraint satisfaction problem
A constraint satisfaction neural network (CSNN) approach is proposed for breast cancer diagnosis using mammographic and patient history findings. Initially, the diagnostic decision to biopsy was formulated as a constraint satisfaction problem. Then, an associative memory type neural network was applied to solve the problem. The proposed network has a flexible, nonhierarchical architecture that allows it to operate not only as a predictive tool but also as an analysis tool for knowledge discovery of association rules. The CSNN was developed and evaluated using a database of 500 nonpalpable breast lesions with definitive histopathological diagnosis. The CSNN diagnostic performance was evaluated using receiver operating characteristic analysis (ROC). The results of the study showed that the CSNN ROC area index was 0.84+/-0.02. The CSNN predictive performance is competitive with that achieved by experienced radiologists and backpropagation artificial neural networks (BP-ANNs) presented before. Furthermore, the study illustrates how CSNN can be used as a knowledge discovery tool overcoming some of the well-known limitations of BP-ANNs.
- 16 May 2001
- Published by Wiley in Medical Physics
- Vol. 28 (5) , 804-811
A neural network approach to breast cancer diagnosis as a constraint satisfaction problem
A constraint satisfaction neural network (CSNN) approach is proposed for breast cancer diagnosis using mammographic and patient history findings. Initially, the diagnostic decision to biopsy was formulated as a constraint satisfaction problem. Then, an associative memory type neural network was applied to solve the problem. The proposed network has a flexible, nonhierarchical architecture that allows it to operate not only as a predictive tool but also as an analysis tool for knowledge discovery of association rules. The CSNN was developed and evaluated using a database of 500 nonpalpable breast lesions with definitive histopathological diagnosis. The CSNN diagnostic performance was evaluated using receiver operating characteristic analysis (ROC). The results of the study showed that the CSNN ROC area index was 0.84+/-0.02. The CSNN predictive performance is competitive with that achieved by experienced radiologists and backpropagation artificial neural networks (BP-ANNs) presented before. Furthermore, the study illustrates how CSNN can be used as a knowledge discovery tool overcoming some of the well-known limitations of BP-ANNs.
- 1 November 2000
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 175 (5) , 1347-1352
Case-Based Reasoning Computer Algorithm that Uses Mammographic Findings for Breast Biopsy Decisions
OBJECTIVE. We present case-based reasoning computer software developed from mammographic findings to provide support for the clinical decision to perform biopsy of the breast. SUBJECTS AND METHODS. The case-based reasoning system is designed to support the decision to perform biopsy in those patients who have suspicious findings on diagnostic mammography. Currently, between 66% and 90% of biopsies are performed on benign lesions. Our system is designed to help decrease the number of benign biopsies without missing malignancies. Clinicians interpret the mammograms using a standard reporting lexicon. The case-based reasoning system compares these findings with a database of cases with known outcomes (from biopsy) and returns the fraction of similar cases that were malignant. This malignancy fraction is an intuitive response that the clinician can then consider when making the decision regarding biopsy. RESULTS. The system was evaluated using a round-robin sampling scheme and performed with an area under the receiver operating characteristic curve of 0.83, comparable with the performance of a neural network model. If only the cases returning a malignancy fraction of greater than a threshold of 0.10 are sent to biopsy, no malignancies would be missed, and the number of benign biopsies would be decreased by 25%. At a threshold of 0.21, 98%, of the malignancies would be biopsied, and the number of benign biopsies would be decreased by 41%. CONCLUSION. This preliminary investigation indicates that the case-based reasoning approach to computer-aided diagnosis has the potential to improve the accuracy of breast cancer diagnosis on mammography.
- 1 November 2000
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 175 (5) , 1347-1352
Case-Based Reasoning Computer Algorithm that Uses Mammographic Findings for Breast Biopsy Decisions
OBJECTIVE. We present case-based reasoning computer software developed from mammographic findings to provide support for the clinical decision to perform biopsy of the breast. SUBJECTS AND METHODS. The case-based reasoning system is designed to support the decision to perform biopsy in those patients who have suspicious findings on diagnostic mammography. Currently, between 66% and 90% of biopsies are performed on benign lesions. Our system is designed to help decrease the number of benign biopsies without missing malignancies. Clinicians interpret the mammograms using a standard reporting lexicon. The case-based reasoning system compares these findings with a database of cases with known outcomes (from biopsy) and returns the fraction of similar cases that were malignant. This malignancy fraction is an intuitive response that the clinician can then consider when making the decision regarding biopsy. RESULTS. The system was evaluated using a round-robin sampling scheme and performed with an area under the receiver operating characteristic curve of 0.83, comparable with the performance of a neural network model. If only the cases returning a malignancy fraction of greater than a threshold of 0.10 are sent to biopsy, no malignancies would be missed, and the number of benign biopsies would be decreased by 25%. At a threshold of 0.21, 98%, of the malignancies would be biopsied, and the number of benign biopsies would be decreased by 41%. CONCLUSION. This preliminary investigation indicates that the case-based reasoning approach to computer-aided diagnosis has the potential to improve the accuracy of breast cancer diagnosis on mammography.
- 6 January 2000
- Published by Wiley in Medical Physics
- Vol. 27 (1) , 13-22
Segmentation of suspicious clustered microcalcifications in mammograms
We have developed a multistage computer-aided diagnosis (CAD) scheme for the automated segmentation of suspicious microcalcification clusters in digital mammograms. The scheme consisted of three main processing steps. First, the breast region was segmented and its high-frequency content was enhanced using unsharp masking. In the second step, individual microcalcifications were segmented using local histogram analysis on overlapping subimages. For this step, eight histogram features were extracted for each subimage and were used as input to a fuzzy rule-based classifier that identified subimages containing microcalcifications and assigned the appropriate thresholds to segment any microcalcifications within them. The final step clustered the segmented microcalcifications and extracted the following features for each cluster: the number of microcalcifications, the average distance between microcalcifications, and the average number of times pixels in the cluster were segmented in the second step. Fuzzy logic rules incorporating the cluster features were designed to remove nonsuspicious clusters, defined as those with typically benign characteristics. A database of 98 images, with 48 images containing one or more microcalcification clusters, provided training and testing sets to optimize the parameters and evaluate the CAD scheme, respectively. The results showed a true positive rate of 93.2% and an average of 0.73 false positive clusters per image. A comparison of our results with other reported segmentation results on the same database showed comparable sensitivity and at the same time an improved false positive rate. The performance of the CAD scheme is encouraging for its use as an automatic tool for efficient and accurate diagnosis of breast cancer.
- 6 January 2000
- Published by Wiley in Medical Physics
- Vol. 27 (1) , 13-22
Segmentation of suspicious clustered microcalcifications in mammograms
We have developed a multistage computer-aided diagnosis (CAD) scheme for the automated segmentation of suspicious microcalcification clusters in digital mammograms. The scheme consisted of three main processing steps. First, the breast region was segmented and its high-frequency content was enhanced using unsharp masking. In the second step, individual microcalcifications were segmented using local histogram analysis on overlapping subimages. For this step, eight histogram features were extracted for each subimage and were used as input to a fuzzy rule-based classifier that identified subimages containing microcalcifications and assigned the appropriate thresholds to segment any microcalcifications within them. The final step clustered the segmented microcalcifications and extracted the following features for each cluster: the number of microcalcifications, the average distance between microcalcifications, and the average number of times pixels in the cluster were segmented in the second step. Fuzzy logic rules incorporating the cluster features were designed to remove nonsuspicious clusters, defined as those with typically benign characteristics. A database of 98 images, with 48 images containing one or more microcalcification clusters, provided training and testing sets to optimize the parameters and evaluate the CAD scheme, respectively. The results showed a true positive rate of 93.2% and an average of 0.73 false positive clusters per image. A comparison of our results with other reported segmentation results on the same database showed comparable sensitivity and at the same time an improved false positive rate. The performance of the CAD scheme is encouraging for its use as an automatic tool for efficient and accurate diagnosis of breast cancer.