MBMarcelo Oscar Biagetti

Marcelo Oscar Biagetti

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marcelo Oscar Biagetti has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • Esteban Raúl Valverde

    Grupo de Sistema Cardiovascular, Instituto de Ingeniería Biomédica (IIBM), Facultad de Ingeniería, Universidad de Buenos Aires, Buenos Aires C1063, Argentina

    3 shared publications
  • Guillermo Claudio Bertrán

    Cardiac Electrophysiology Laboratory. Physiology Department, Favaloro University. Buenos Aires, Argentina

    2 shared publications
  • Pedro David Arini

    Cardiac Electrophysiology Laboratory. Physiology Department, Favaloro University. Buenos Aires, Argentina

    2 shared publications
  • Ricardo Alberto Quinteiro

    Cardiac Electrophysiology Laboratory. Physiology Department, Favaloro University. Buenos Aires, Argentina

    2 shared publications
  • David Cuesta-Frau

    Department of System Informatics and Computers, Universitat Politècnica de València, 03801 Alcoy, Spain

    1 shared publication
  • Guillermo Claudio Bertran

    The Cardiac Electrophysiology Laboratory, Basic Science Research Institute, Dr. René G. Favaloro Foundation, Buenos Aires, Argentina

    1 shared publication

Latest Publications

  • T-wave Alternans Analysis Improvement by Means of Curve Alignment Prior to Distance Calculation

    by David Cuesta-Frau, Marcelo Biagetti, Pau Mico-Tormos, Mateo Aboy, Ricardo Quinteiro

    Tracking of repolarization instabilities in the ECG, such as T-wave alternans (TWA), has become a popular non-invasive method to assess the vulnerability to malignant arrhythmic events. These instabilities are usually characterized by small amplitude changes and their measurement is difficult due to the presence of noise and artifacts. Several methods have been recently proposed to address this problem. Most of them are based on amplitude analysis of beat-to-beat alternation of the T wave. This paper describes a preprocessing stage intended to be used prior to amplitude analysis and aimed at improving the alignment between consecutive T waves. This increases the accuracy of the difference calculation.


  • Beat‐to‐Beat Repolarization Variability Measured by T Wave Spectral Variance Index in Chronic Infarcted Animals

    by Esteban Raúi Valverde, Ricardo Alberto Quinteiro, Pedro David Arini, Guillermo Claudio Bertrán, Marcelo Oscar Biagetti

    Background: Recent experimental and clinical studies have shown that beat‐to‐beat variability of repolarization morphology is associated with an increased risk for developing malignant ventricular arrhythmias. However, few data exist on the relationship between beat‐to‐beat repolarization variability and myocardial infarction itself.Methods and Results: In the present work we tested the algorithm of T wave spectral variance (TWSV) using the two dimension fast Fourier transform, in an animal model of myocardial infarction to extend the evidences that support the existence of beat‐to‐beat alteration in repolarization during the chronic stage of myocardial infarction. Thirty‐four New Zealand rabbits were included in the study and divided in two groups. Group I (N = 24) exposed to surgical ligation of the left anterior descendent coronary artery. Group II (N = 10) sham operated animals. The TWSV index was calculated before and after 15 and 45 days of surgery. Both groups showed significant increments in TWSV after 15 days postsurgery. However, while the sham animals return to its control value, the infarcted group exhibited values of the TWSV index that remains significantly high after 45 days of surgery, with a mean increment of 28.7% (P Conclusion: This noninvasive measure confirms the presence of temporal repolarization variability associated with chronic myocardial infarction and further contributes to identify the infarcted animals. A.N.E. 2002;7(4):319–325


  • Differential Modulation of Electrocardiographic Indices of Ventricular Repolarization Dispersion Depending on the Site of Pacing During Premature Stimulation

    by Pedro David Arini, Ricar Do Alberto Quinteiro, Esteban Raúl Valverde, Guillermo Claudio Bertrán, Marcelo Oscar Biagetti

    Dispersion of ventricular repolarization has been shown to increase with premature stimulation. Moreover, a straight correlation between the amount of dispersion of repolarization and the vulnerability to ventricular fibrillation was reported. On the other hand, differences between right ventricular (RV) and left ventricular (LV) fibrillation threshold have been reported. However, no data exist regarding the influence of the site of stimulation on modulation of dispersion of repolarization. In the present study, several ECG indices of dispersion of repolarization, as a function of the coupling interval and the site of stimulation, were evaluated in a modified Langendorff-perfused rabbit heart (n = 12), with a 5 x 8 array of a simulated body surface unipolar lead system. As the coupling interval was shortened, a biphasic modulation of dispersion of repolarization was found when stimuli were elicited at the LV. In contrast, when the heart was paced from the RV, the dispersion increased monotonically as coupling interval was shortened. A differential behavior of the modulation of dispersion of repolarization was found as a function of the site of stimulation.


  • Evaluation of QT Interval Dispersion in a Multiple Electrodes Recording System versus 12-Lead Standard ECG in an In Vitro Model

    by Pedro David Arini, Ricardo Alberto Quinteiro, Esteban Raúl Valverde, Guillermo Claudio Bertran, Marcelo Oscar Biagetti