JTJozef Trela

Jozef Trela

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jozef Trela has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Performance of partial nitritation-anammox processes at mainstream conditions in an IFAS system

    by Alba Pedrouso, Jozef Trela, Angeles Val del Rio, Anuska Mosquera-Corral, Elzbieta Plaza


  • Open Access

    Innovative technologies in municipal wastewater treatment plants in Sweden to improve Baltic Sea water quality

    by Józef Trela, Elżbieta Płaza

    The article presents new trends in the treatment of municipal wastewater in Sweden caused by the constantly increasing requirements for discharging pollutants into Baltic Sea waters. The development of new technologies for nitrogen removal, pharmaceutical residues removal and the possibility of using membrane processes in wastewater treatment is presented. The state of research on innovative wastewater treatment processes at the level of pilot-scale tests and their implementation in full technical scale has been described. These technologies can allow the application of new, economical and environmentally friendly wastewater treatment processes based on biological, chemical and physical methods. Swedish wastewater treatment plants are preparing to meet the new conditions required for discharged wastewater with a value of 6 mg N/L for total nitrogen and 0.2 mg P/L for total phosphorus. This requires large investments in the reconstruction of municipal wastewater treatment plants and the introduction of new treatment processes.


  • Evaluation of deammonification process performance at different aeration strategies

    by M. Zubrowska-Sudol, J. Yang, J. Trela, E. Plaza

    In a deammonification process applied in the moving bed biofilm reactor (MBBR) oxygen is a crucial parameter for the process performance and efficiency. The objective of this study was to investigate different aeration strategies, characterised by the ratio between non-aerated and aerated phase times (R) and dissolved oxygen concentrations (DO). The series of batch tests were conducted with variable DO concentrations (2, 3, 4 mg L−1) and R values (0-continuous aeration; 1/3, 1, 3-intermittent aeration) but with the same initial ammonium concentration, volume of the moving bed and temperature. It was found that the impact of DO on deammonification was dependent on the R value. At R=0 and R=1/3, an increase of DO caused a significant increase in nitrogen removal rate, whereas for R=1 and R=3 similar rates of the process were observed irrespectively of the DO. The highest nitrogen removal rate of 3.33 g N m−2 d−1 (efficiency equal to 69.5%) was obtained at R=1/3 and DO=4 mg L−1. Significantly lower nitrogen removal rates (1.17–1.58 g N m−2 d−1) were observed at R=1 and R=3 for each examined DO. It was a consequence reduced aerated phase duration times and lesser amounts of residual nitrite in non-aerated phases as compared to R=1/3.


  • Influence of Aeration Conditions on Nitrogen Removal Rate in One-Stage Partial Nitrification/Anammox Process

    by Jingjing Yang, Monika Zubrowska-Sudol, Jozef Trela, Elzbieta Plaza

    N a partial nitrification/anammox process applied in the moving bed biofilm reactor (MBBR), oxygen is an important parameter for the process performance...


  • A one-stage system with partial nitritation and Anammox processes in the moving-bed biofilm reactor

    by B. Szatkowska, G. Cema, E. Plaza, J. Trela, B. Hultman

    The ability of bacterial cultures to create biofilm brings a possibility to enhance biological wastewater treatment efficiency. Moreover, the ability of Anammox and Nitrosomonas species to grow within the same biofilm layer enabled a one-stage system for nitrogen removal to be designed. Such a system, with Kaldnes rings as carriers for biofilm growth, was tested in a technical pilot plant scale (2.1 m3) at the Himmerfjärden Waste Water Treatment Plant (WWTP) in the Stockholm region. The system was directly supplied with supernatant originating from dewatering of digested sludge containing high ammonium concentrations. Nearly 1-year of operational data showed that during the partial nitritation/Anammox process, alkalinity was utilised parallel to ammonium removal. The process resulted in a small pH drop, and its relationship with conductivity was found. The nitrogen removal rate for the whole period oscillated around 1.5 g N m−2d−1 with a maximum value equal to 1.9 g N m−2d−1. Parallel to the pilot plant experiment, a series of batch tests were run to investigate the influence on removal rates of different dissolved oxygen conditions and addition of nitrite. The highest nitrogen removal rate (5.2 g N m−2d−1) in batch tests was obtained when the Anammox process was stimulated by the addition of nitrite. In the simultaneous partial nitritation and Anammox process, the partial nitritation was the rate-limiting step.


  • Nitrogen removal rates at a technical-scale pilot plant with the one-stage partial nitritation/Anammox process

    by G. Cema, B. Szatkowska, E. Plaza, J. Trela, J. Surmacz-Górska

    Traditional nitrification/denitrification is not suitable for nitrogen removal when wastewater contains high concentrations of ammonium nitrogen and low concentrations of biodegradable carbon. Recently, a deammonification process was developed and proposed as a new technology for treatment of such streams. This process relies on a stable interaction between aerobic bacteria Nitrosomonas, that accomplish partial nitritation and anaerobic bacteria Planctomycetales, which conduct the Anammox reaction. Simultaneous performance of these two processes can lead to a complete autotrophic nitrogen removal in one single reactor. The experiments where nitrogen was removed in one reactor were performed at a technical-scale moving-bed pilot plant, filled with Kaldnes rings and supplied with supernatant after dewatering of digested sludge. It was found that a nitrogen removal rate obtained at the pilot plant was 1.9 g m−2d−1. Parallel to the pilot plant run, a series of batch tests were carried out under anoxic and aerobic conditions. Within the batch tests, where the pilot plant's conditions were simulated, removal rates reached up to 3 g N m−2d−1. Moreover, the batch tests with inhibition of Nitrosomonas showed that only the Anammox bacteria (not anoxic removal by Nitrosomonas) are responsible for nitrogen removal.


  • Combined partial nitritation/Anammox system for treatment of digester supernatant

    by L. Gut, E. Płaza, J. Trela, B. Hultman, J. Bosander

    One-year (2004) comprehensive investigations in a semi-industrial pilot plant (5 m3) were carried out with the aim of assessing the influence of operational parameters on the partial nitritation/Anammox system performance. In the system designed as a moving-bed biofilm reactor, the influent nitrogen load to the Anammox reactor was progressively increased and a stable Anammox bacterial culture was obtained. Interaction between subsequent aerobic and anaerobic conditions in the partial nitritation and Anammox reactors, respectively, granted conditions to remove nitrogen through the nitrite route. It implies that the oxygen supply can be limited to a high extent. A control strategy for the partial nitritation step relied on concomitant adjustment of the air supply with a variable influent nitrogen load, which can be monitored by both pH and conductivity measurements. In the Anammox reactor, an influent nitrite-to-ammonium ratio plays a vital role in obtaining efficient nitrogen removal. During the 1-year experimental period, the Anammox reactor was operated steadily and average nitrogen removal efficiency was 84% with 97% as the maximum value.


  • Factors Affecting Biological Nitrogen Removal Efficiency in a Large Wastewater Treatment Plant

    by Elzbieta Plaza, Jan Bosander, Jozef Trela

    The pre-denitrification method, with internal carbon source for biological nitrogen removal, has been studied in full-scale experiments at a large wastewater treatment plant (flow 130,000 m3/d). Factors controlling nitrogen removal, such as fraction of anoxic zone and organic material content in wastewater are discussed. A flexible system with fine bubble membrane disc diffusers made it possible to change the ratio between the volumes for nitrification and denitrification. The denitrification process was limited by lack of organic carbon in the wastewater and increasing the fraction of anoxic zone did not improve the efficiency of the system. With the help of on-line analysers for total nitrogen and chemical oxygen demand, the relationship between the denitrification efficiency and the carbon/nitrogen ratio has been given careful study. The average value for chemical oxygen demand after primary sedimentation was only 130 mg/l and the value for the COD/N ratio was found to be 6.3. The denitrification rate was usually in the range of 1.0 and 2.0 mg NO3-N/g MLVSS h.