JEJan Ehrhardt

Jan Ehrhardt

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jan Ehrhardt has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Medical Image Computing for Computer-supported Diagnostics and Therapy

    by J. Ehrhardt, H. Handels

    Summary Objectives: Medical image computing has become one of the most challenging fields in medical informatics. In image-based diagnostics of the future software assistance will become more and more important, and image analysis systems integrating advanced image computing methods are needed to extract quantitative image parameters to characterize the state and changes of image structures of interest (e.g. tumors, organs, vessels, bones etc.) in a reproducible and objective way. Furthermore, in the field of software-assisted and navigated surgery medical image computing methods play a key role and have opened up new perspectives for patient treatment. However, further developments are needed to increase the grade of automation, accuracy, reproducibility and robustness. Moreover, the systems developed have to be integrated into the clinical workflow. Methods: For the development of advanced image computing systems methods of different scientific fields have to be adapted and used in combination. The principal methodologies in medical image computing are the following: image segmentation, image registration, image analysis for quantification and computer assisted image interpretation, modeling and simulation as well as visualization and virtual reality. Especially, model-based image computing techniques open up new perspectives for prediction of organ changes and risk analysis of patients and will gain importance in diagnostic and therapy of the future. Results: From a methodical point of view the authors identify the following future trends and perspectives in medical image computing: development of optimized application-specific systems and integration into the clinical workflow, enhanced computational models for image analysis and virtual reality training systems, integration of different image computing methods, further integration of multimodal image data and biosignals and advanced methods for 4D medical image computing. Conclusions: The development of image analysis systems for diagnostic support or operation planning is a complex interdisciplinary process. Image computing methods enable new insights into the patient’s image data and have the future potential to improve medical diagnostics and patient treatment.


  • Structure-preserving Interpolation of Temporal and Spatial Image Sequences Using an Optical Flow-based Method

    by D. Säring, H. Handels, J. Ehrhardt

    Summary Objectives: Modern tomographic imaging devices enable the acquisition of spatial and temporal image sequences. But, the spatial and temporal resolution of such devices is limited and therefore image interpolation techniques are needed to represent images at a desired level of discretization. This paper presents a method for structure-preserving interpolation between neighboring slices in temporal or spatial image sequences. Methods: In a first step, the spatiotemporal velocity field between image slices is determined using an optical flow-based registration method in order to establish spatial correspondence between adjacent slices. An iterative algorithm is applied using the spatial and temporal image derivatives and a spatiotemporal smoothing step. Afterwards, the calculated velocity field is used to generate an interpolated image at the desired time by averaging intensities between corresponding points. Three quantitative measures are defined to evaluate the performance of the interpolation method. Results: The behaviorand capability of the algorithm is demonstrated by synthetic images. A population of 17 temporal and spatial image sequences are utilized to compare the optical flow-based interpolation method to linear and shape-based interpolation. The quantitative results show that the optical flow-based method outperforms the linear and shape-based interpolation statistically significantly. Conclusions: The interpolation method presented is able to generate image sequences with appropriate spatial or temporal resolution needed for image comparison, analysis or visualization tasks. Quantitative and qualitative measures extracted from synthetic phantoms and medical image data show that the new method definitely has advantages over linear and shape-based interpolation.


    • 1 January 2006
      • Vol. 124, 977-82

    Generation of 4D CT image data and analysis of lung tumour mobility during the breathing cycle.

    by Heinz Handels, Rene Werner, Thorsten Frenzel, Dennis Säring, Wei Lu, Daniel Low, Jan Ehrhardt

    The mobility of lung tumours during the breathing cycle is a source of error in radiotherapy treatment planning. Spatio-temporal CT data sets can be used to measure the movement of lung tumours caused by breathing. Because modern CT scanners can only scan a limited region of the body simultaneously at different times, patients have to be scanned in segments consisting of multiple slices. For studying free breathing motion multislice CT scans can be collected simultaneously with digital spirometry over several breathing cycles. The image data set is assembled by sorting the free breathing multislice CT scans according to the couch position and the tidal volume. But artefacts can occur because there are no data segments for exactly the same tidal volume and all couch positions. In this paper, a non-linear registration method is used to interpolate and reconstruct 4D CT data sets from multislice CT scans in high quality. The non-linear registration estimates a velocity field between successive scans, which is used to reconstruct a 4D CT data set by interpolating data at user-defined tidal volumes. By this technique, artefacts can be reduced significantly. Furthermore, the reconstructed 4D CT data sets are used for studying the motion of lung tumours during the respiratory cycle. The reconstructed 4D data sets of 4 patients were used to quantify the individual lung tumour motion as well as to estimate the tumour's appearance probability during a breathing cycle.