GAGary M. Ansel

Gary M. Ansel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gary M. Ansel has a total of 328 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Safety and effectiveness of the INVATEC MO.MA® proximal cerebral protection device during carotid artery stenting: Results from the ARMOUR pivotal trial

    by Gary M. Ansel, L. Nelson Hopkins, Michael R. Jaff, Paolo Rubino, J. Michael Bacharach, Dierk Scheinert, Subbarao Myla, Tony Das, Alberto Cremonesi, The Investigators for the ARMOUR Pivotal Trial

    Objective: The multicenter ARMOUR (ProximAl PRotection with the MO.MA Device DUring CaRotid Stenting) trial evaluated the 30‐day safety and effectiveness of the MO.MA® Proximal Cerebral Protection Device (Invatec, Roncadelle, Italy) utilized to treat high surgical risk patients undergoing carotid artery stenting (CAS). Background: Distal embolic protection devices (EPD) have been traditionally utilized during CAS. The MO.MA device acts as a balloon occlusion “endovascular clamping” system to achieve cerebral protection prior to crossing the carotid stenosis. Methods: This prospective registry enrolled 262 subjects, 37 roll‐in and 225 pivotal subjects evaluated with intention to treat (ITT) from September 2007 to February 2009. Subjects underwent CAS using the MO.MA device. The primary endpoint, myocardial infarction, stroke, or death through 30 days (30‐day major adverse cardiac and cerebrovascular events [MACCE]) was compared to a performance goal of 13% derived from trials utilizing distal EPD. Results: For the ITT population, the mean age was 74.7 years with 66.7% of the cohort being male. Symptomatic patients comprised 15.1% and 28.9% were octogenarians. Device success was 98.2% and procedural success was 93.2%. The 30‐day MACCE rate was 2.7% [95% CI (1.0–5.8%)] with a 30‐day major stroke rate of 0.9%. No symptomatic patient suffered a stroke during this trial. Conclusions: The ARMOUR trial demonstrated that the MO.MA® Proximal Cerebral Protection Device is safe and effective for high surgical risk patients undergoing CAS. The absence of stroke in symptomatic patients is the lowest rate reported in any independently adjudicated prospective multicenter registry trial to date.


  • THE UTILIZATION OF PTFE COVERED STENTS FOR THE TREATMENT OF RENAL ARTERY IN-STENT RESTENOSIS

    by Nicholas J. Ruggiero, Joseph Garasic, Michael R. Jaff, Andrew B. McCann, Thomas J. Kiernan, Brian G. Hynes, Douglas E. Drachman, Robert Schainfeld, Kenneth Rosenfield, Gary M. Ansel

  • Contributors

    by Hani Abujudeh, Andreas Adam, Hassan M. Ahmad, Sun Ho Ahn, Kamran Ahrar, Morvarid Alaghmand, Agaicha Alfidja, Ahmad I. Alomari, Gennaro Ambrosanio, Soon Ghee Ang, et al.

  • Evolving Modalities for Femoropopliteal Interventions

    by Gary M. Ansel, Alan B. Lumsden

    Despite technical advances in balloon design and technique, there has been little improvement of primary patency rates after balloon-based endovascular interventions for all but focal femoropopliteal lesions. Improving on stainless steel models, nitinol stents have been associated with favorable short- and midterm primary patency rates; studies with longer-term follow-up will be required to learn whether restenosis is ongoing, with continued loss of primary patency. Studies in recent years have shown varying incidences of mechanical fatigue leading to nitinol stent fracture. Covered stents are designed to prevent the tissue infiltration and intimal hyperplasia that can lead to bare metal in-stent restenosis. Several clinical studies, mainly single-center registries, have demonstrated a general effectiveness of the Hemobahn/Viabahn polytetrafluoroethylene-covered stent-grafts, approved for femoral arterial occlusive disease, and have helped to distinguish indications for use and to delineate possible failure modes. A multicenter randomized trial, which has completed enrollment, will compare the Viabahn with self-expanding bare nitinol stents. The primary use of drug-eluting stents (DES) has become routine clinical practice for coronary artery disease. The 2-phase multicenter randomized double-blind SIROCCO trials have been completed, with results published through 24 months. Follow-up demonstrated the feasibility and safety of deploying sirolimus-eluting stents in the femoropopliteal segment but failed to show superior efficacy for DES versus bare nitinol stents. However, the restenosis rates with bare metal stents were unexpectedly low. A paclitaxel-eluting stent without a polymer coating is currently being evaluated in the recently enrolled Zilver PTX randomized trial and international registry. A polymer-based everolimus-eluting stent is being evaluated for femoropopliteal use in the nonrandomized European STRIDES trial. Balloons coated with paclitaxel have recently been evaluated for simple femoropopliteal disease with encouraging results through 2 years of follow-up. The bioabsorbable stent concept emerged in response to the potential issues with metal stents, but to date no investigational device has successfully overcome issues such as relatively low radial force and variable degradation rates.


  • The “art” of medicine and the “smokescreen” of the randomized trial off‐label use of vascular devices

    by Gary M. Ansel, Michael R. Jaff

    Once a device is approved for sale in the United States by the Food and Drug Administration (FDA), it can legally be used by doctors to treat any condition a physician determines is medically appropriate. Based on postmarket published data and physician procedural experience, this may even become the standard of care when an alternative device either does not exist or is inferior in performance, even before FDA approval. This right of physicians to practice medicine without FDA approval is Federal law. The off‐label use of medical devices for the treatment of peripheral vascular disease has recently become the latest target by groups with interests that have little to do with patient care. This interference has begun to negatively impact the latitude necessary for physicians to best treat their patients.


  • Carotid stenting with embolic protection: evolutionary advances

    by Gary M Ansel, Michael R Jaff

    Stroke is one of the most significant causes of death and morbidity worldwide. Atherosclerotic stenosis of the extracranial internal carotid artery has been invoked as a common causative factor for stroke in over 20% of patients. Although medical therapy can help to prevent the onset and progression of carotid arteriosclerosis, open surgical carotid endarterectomy has been the gold standard for treating severe blockage. Carotid artery stenting has recently demonstrated efficacy in stroke prevention from atherosclerosis, and in high-risk surgical subgroups, has been shown to be associated with a reduction in the risk of myocardial infarction. The controversy for carotid stenting surrounds the incidence of periprocedural stroke. Will embolic protection devices (EPDs) decrease this risk? EPDs continue to evolve with various engineering strategies directed at increasing the efficiency of protection. There are two major categories of EPDs: distal occlusion, either with balloons (e.g., Percusurge, Medtronic Corporation, MN, USA); or distal filtration (e.g., Angioguard, Cordis Corporation, NJ, USA). The second method is proximal protection (e.g., MoMA device, Invatec Corporation, Brescia, Italy). We review the results of trials currently evaluating carotid stenting with both distal and proximal embolic protection.


  • Treatment of acute limb ischemia with a percutaneous mechanical thrombectomy‐based endovascular approach: 5‐year limb salvage and survival results from a single center series

    by Gary M. Ansel, Charles F. Botti, Mitchell J. Silver

    Objectives: The study evaluated long‐term limb salvage and survival of an endovascular approach that incorporates mechanical thrombectomy (PMT) in the management of arterial thrombosis. Background: Acute limb ischemia is associated with a high risk of amputation and death. Previous reports from the United States (U.S.) of surgical and nonsurgical treatments are limited to primarily 30 days to 1 year. Methods: Single‐center, retrospective review of 57 consecutive patients (30 male, 27 female; mean age 63.8 ± 13.8 years) treated for limb threatening ischemia due to thrombotic arterial occlusions. Data includes baseline assessments, procedural outcomes, in‐hospital complications, 30‐day, and long‐term follow‐up. Results: Ninety‐three percent of patients (n = 53) presented with onset of symptoms (n = 55) with mortality of 3.5% (n = 2). Thirty‐day limb salvage and mortality were 94.7% (n = 54) and 5.3% (n = 3), respectively. At mean 5‐year follow‐up (mean = 62 months), three patients have been lost to follow‐up. The results of 54/57 (94.7%) are available. Amputation free survival was 94.7% (n = 36/38) with long‐term mortality rate of 29.6% (n = 16/54). Conclusions: Acute limb ischemia treated with PMT alone or in combination with thrombolysis, followed by definitive therapy, results in favorable long‐term limb salvage. Allowing for appreciable long‐term mortality in vascular patients, survivors demonstrate amputation‐free success from the initial endovascular procedure with low reintervention rate.


  • Safety and efficacy of staple‐mediated femoral arteriotomy closure: Results from a randomized multicenter study

    by Gary Ansel, Stephen Yakubov, Christopher Neilsen, David Allie, Robert Stoler, Patrick Hall, Peter Fail, Timothy Sanborn, Ronald P. Caputo

    Background: Mechanical closure of percutaneous femoral arteriotomies following catheter based procedures remains problematic.Methods: The EVS closure device is the first to utilize a staple to effect arteriotomy closure and was compared to manual compression following sheath removal in a 362 patient randomized (2:1 to device) multicenter trial. As pre‐specified, one half of the patients underwent coronary intervention.Results: Time to hemostasis was significantly reduced in the EVS group for both diagnostic (3.3 ± 2.6 vs. 19.3 ± 5.7 minutes; p < 0.001) and interventional procedures (5.5 ± 5.1 vs. 22.3 ± 9.9 minutes; p < 0.0001). Time to ambulation was similarly reduced in the EVS group following diagnostic (2.4 ± 3.3 vs. 6.0 ± 5.2 hours; p < 0.001) and interventional procedures (3.4 ± 4.5 vs. 7.6 ± 7.0 hours; p < 0.001). The incidence of major complications was similar between the EVS and manual compression groups at discharge (0.4% vs. 1.7%; p = NS) and at 30 day follow‐up (0.4% vs. 2.5%; p = NS).Conclusion: Compared to manual compression, the EVS device provides a safe and effective method of femoral artery closure.