No-Suk Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
No-Suk Park has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- B.Y. Son
Department of Wonju Multi-Regional Water Water Supply System, Korea Water Resources Corporation, Songjeon-ri, Hengsung-eup, hengsung-gun, Kangwon-do, 225-803, South Korea
1 shared publication C.-H. Bae
Korea Institute of Water and Environment, 462-1, Jeonmin-Dong, Yuseong-Gu, Daejeon, 305-730, Korea
1 shared publication- C.K. Wang
Dept. of Environmental Engineering, Chungnam National University, 220, Gung-dong, Yusung-gu, Daejeon, 305-764, South Korea
1 shared publication Cheol-Ho Bae
Water Research Center, Korea Institute of Water and Environment, Korea Water Resources Corporation, 462-1, Jeonmin-Dong, Yusung-Gu, Daejeon, 305-730, Republic of Korea
1 shared publicationH. Park
Department of Civil Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Korea
1 shared publicationH.-W. Ahn
Korea Institute of Water and Environment, 462-1, Jeonmin-Dong, Yuseong-Gu, Daejeon, 305-730, Korea
1 shared publication
Latest Publications
- 1 August 2007
- Published by IWA Publishing in Journal of Water Supply: Research and Technology—AQUA
- Vol. 56 (5) , 335-343
Assessment of galvanized steel pipes for water service in buildings by direct diagnosis method
- 1 August 2007
- Published by IWA Publishing in Journal of Water Supply: Research and Technology—AQUA
- Vol. 56 (5) , 335-343
Assessment of galvanized steel pipes for water service in buildings by direct diagnosis method
- 1 May 2007
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 133 (5) , 507-514
Reaggregation of Flocs in Coagulation-Cross-Flow Microfiltration
Cake layer in cross-flow microfiltration can be reduced by coagulation of particles. This is because enlarging particle size by coagulation increases shear induced diffusivity and the back transport of rejected particles. In addition, it is known that flocs can be broken when they are passing through a pump. In light of these facts, this study aims to experimentally look at the floc-breaking phenomenon being related to cake layer reduction. Kaolin is used as particles and aluminum sulfate as a coagulant for the experiment. The results of particle size analyses show that the aggregated particles in feed are completely disaggregated by the pump but reaggregated in the membrane module. This suggests that the reaggregation of particles is critical to cake reduction and flux enhancement. This study proves that most of it occurs around the movable cake layer on membrane where G value is small. Charge neutralization of particles is also proven a dominant coagulation mechanism for reaggregation around the movable...
- 1 May 2007
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 133 (5) , 507-514
Reaggregation of Flocs in Coagulation-Cross-Flow Microfiltration
Cake layer in cross-flow microfiltration can be reduced by coagulation of particles. This is because enlarging particle size by coagulation increases shear induced diffusivity and the back transport of rejected particles. In addition, it is known that flocs can be broken when they are passing through a pump. In light of these facts, this study aims to experimentally look at the floc-breaking phenomenon being related to cake layer reduction. Kaolin is used as particles and aluminum sulfate as a coagulant for the experiment. The results of particle size analyses show that the aggregated particles in feed are completely disaggregated by the pump but reaggregated in the membrane module. This suggests that the reaggregation of particles is critical to cake reduction and flux enhancement. This study proves that most of it occurs around the movable cake layer on membrane where G value is small. Charge neutralization of particles is also proven a dominant coagulation mechanism for reaggregation around the movable...
- 1 June 2006
- Published by IWA Publishing in Journal of Water Supply: Research and Technology—AQUA
- Vol. 55 (4) , 247-256
Examining the effect of transverse troughs on hydrodynamic behavior in a sedimentation basin with CFD simulation and ADV technique
This study was conducted to evaluate the effect of the transverse troughs on hydrodynamic behavior within a full-scale sedimentation basin (flow rate/one basin: 10,000 m3/d) using CFD (Computational Fluid Dynamics) simulation and ADV (Acoustic Doppler Velocimetry) technique. In order to verify the CFD simulation, we measured the factual velocity at 36 points in the full-scale sedimentation basin, whose outlet structure is inadequate, with ADV. Both the CFD simulation and the ADV measurement results were in good accordance with each other. From the CFD simulation results of the existing basin, it was found that extreme upward flow occurs in the near of two transverse troughs. It was suspected that, since the transverse troughs converted the open channel flow into the local closed pipe flow, the increased pressure in this local closed pipe flow region made the extreme upward flow. To solve this problem, it was suggested changing a transverse typed into a finger typed launder and building a longitudinal baffle at the central plain in this study. The CFD simulation results of all retrofitting suggestions told us that the extreme upward flow had occurred especially beneath the transverse troughs, and was much less in the case of a finger-typed launder basin than that in the existing basin. Also, it was predicted that installing a longitudinal baffle made the fully developed flow which is more effective for sedimentation.
- 1 June 2006
- Published by IWA Publishing in Journal of Water Supply: Research and Technology—AQUA
- Vol. 55 (4) , 247-256
Examining the effect of transverse troughs on hydrodynamic behavior in a sedimentation basin with CFD simulation and ADV technique
This study was conducted to evaluate the effect of the transverse troughs on hydrodynamic behavior within a full-scale sedimentation basin (flow rate/one basin: 10,000 m3/d) using CFD (Computational Fluid Dynamics) simulation and ADV (Acoustic Doppler Velocimetry) technique. In order to verify the CFD simulation, we measured the factual velocity at 36 points in the full-scale sedimentation basin, whose outlet structure is inadequate, with ADV. Both the CFD simulation and the ADV measurement results were in good accordance with each other. From the CFD simulation results of the existing basin, it was found that extreme upward flow occurs in the near of two transverse troughs. It was suspected that, since the transverse troughs converted the open channel flow into the local closed pipe flow, the increased pressure in this local closed pipe flow region made the extreme upward flow. To solve this problem, it was suggested changing a transverse typed into a finger typed launder and building a longitudinal baffle at the central plain in this study. The CFD simulation results of all retrofitting suggestions told us that the extreme upward flow had occurred especially beneath the transverse troughs, and was much less in the case of a finger-typed launder basin than that in the existing basin. Also, it was predicted that installing a longitudinal baffle made the fully developed flow which is more effective for sedimentation.
- 1 March 2006
- Published by IWA Publishing in Water Supply
- Vol. 6 (2) , 231-237
A case study for process optimization of direct filtration in Korea
In the case of S water treatment plant, it was designed to be mostly operated by direct filtration mode all the year round. To evaluate the conditions of such operation mode, in this study, we operated pilot plant by direct filtration process by making flocculation treatment water flow into anthracite filter and active carbon (Calgon, Norit) filter which is an assembly of deep bed filter paper, and studied to find out the principle in which turbidity is removed in filter paper by measuring turbidity and head loss by the depth of filter, and an appropriate operation method. Also we conducted comparison evaluation according to kinds of coagulant and evaluation according to the injection of a polymer coagulant, a filter aid, before letting filter flow into flocculation treatment water. On the basis of the optimum operation of direct filtration process using deep bed filtration, it is necessary to decide and inject the optimum injection volume of filter aids taking account for the quality of raw water and to operate anthracite filter, which will also contribute to lowering the operation expenses of a filtration plant and improving the quality of treatment water.
- 1 March 2006
- Published by IWA Publishing in Water Supply
- Vol. 6 (2) , 231-237
A case study for process optimization of direct filtration in Korea
In the case of S water treatment plant, it was designed to be mostly operated by direct filtration mode all the year round. To evaluate the conditions of such operation mode, in this study, we operated pilot plant by direct filtration process by making flocculation treatment water flow into anthracite filter and active carbon (Calgon, Norit) filter which is an assembly of deep bed filter paper, and studied to find out the principle in which turbidity is removed in filter paper by measuring turbidity and head loss by the depth of filter, and an appropriate operation method. Also we conducted comparison evaluation according to kinds of coagulant and evaluation according to the injection of a polymer coagulant, a filter aid, before letting filter flow into flocculation treatment water. On the basis of the optimum operation of direct filtration process using deep bed filtration, it is necessary to decide and inject the optimum injection volume of filter aids taking account for the quality of raw water and to operate anthracite filter, which will also contribute to lowering the operation expenses of a filtration plant and improving the quality of treatment water.
- 1 March 2006
- Published by IWA Publishing in Water Supply
- Vol. 6 (2) , 71-76
Identification and prioritization of performancelimiting factors for water treatment plantoptimization in Korea
Performance limiting factors (PLFs) derived from 161 drinking water treatment plants (DWTPs), assessed by the International Technical Diagnosis and Assistance Center, were analyzed and evaluated in this study. In order to conduct research, 161 DWTPs were divided into five categories depending on their capacity, and into twelve groups according to processes and facilities. From the results of analysis, PLFs and their distribution ratio derived from each category were significantly different. Filtration was the most important performance limiting factor in all DWTPs of five categories, and PLFs in filtration were backwashing velocity, media configuration, bed depth, and formation of mud-ball. The PLFs in coagulation–flocculation process were found to be coagulant dose, mixing intensity, mechanical problems, and others in the order of frequency of occurrence. Also, insufficient disinfection ability, is resulting from insufficient hydraulic detention time, improper chlorine dose and injection point, is the most significant among PLFs in a clear well. In the case of sedimentation, inappropriate baffle structure and excessive upward velocity were PLFs. In addition, the results showed that high turbid water and low alkalinity in rainy season, ferric and manganese ions, and ammonia nitrogen have contributed significantly to the performance of DWTPs.
- 1 March 2006
- Published by IWA Publishing in Water Supply
- Vol. 6 (2) , 71-76
Identification and prioritization of performancelimiting factors for water treatment plantoptimization in Korea
Performance limiting factors (PLFs) derived from 161 drinking water treatment plants (DWTPs), assessed by the International Technical Diagnosis and Assistance Center, were analyzed and evaluated in this study. In order to conduct research, 161 DWTPs were divided into five categories depending on their capacity, and into twelve groups according to processes and facilities. From the results of analysis, PLFs and their distribution ratio derived from each category were significantly different. Filtration was the most important performance limiting factor in all DWTPs of five categories, and PLFs in filtration were backwashing velocity, media configuration, bed depth, and formation of mud-ball. The PLFs in coagulation–flocculation process were found to be coagulant dose, mixing intensity, mechanical problems, and others in the order of frequency of occurrence. Also, insufficient disinfection ability, is resulting from insufficient hydraulic detention time, improper chlorine dose and injection point, is the most significant among PLFs in a clear well. In the case of sedimentation, inappropriate baffle structure and excessive upward velocity were PLFs. In addition, the results showed that high turbid water and low alkalinity in rainy season, ferric and manganese ions, and ammonia nitrogen have contributed significantly to the performance of DWTPs.
- 1 December 2002
- Published by IWA Publishing in Water Supply
- Vol. 2 (5-6) , 47-55
Analysis of local velocity gradients in rapid mixer using particle image velocimetry technique
Recognizing the significance of factual velocity fields in a rapid mixer, this study focuses on analyzing local velocity gradients in various mixer geometries with particle image velocimetry (PIV) and comparing the results of the analysis with the conventional G-value, for reviewing the roles of G-value in the current design and operation practices. The results of this study clearly show that many arguments and doubts are possible about the scientific correctness of G-value, and its current use. This is because the G-value attempts to represent the turbulent and complicated factual velocity field in a jar. Also, the results suggest that it is still a good index for representing some aspects of mixing condition, at least, mixing intensity. However, it cannot represent the distribution of velocity gradients in a jar, which is an important factor for mixing. This study as a result suggests developing another index for representing the distribution to be used with the G-value.
- 1 December 2002
- Published by IWA Publishing in Water Supply
- Vol. 2 (5-6) , 47-55
Analysis of local velocity gradients in rapid mixer using particle image velocimetry technique
Recognizing the significance of factual velocity fields in a rapid mixer, this study focuses on analyzing local velocity gradients in various mixer geometries with particle image velocimetry (PIV) and comparing the results of the analysis with the conventional G-value, for reviewing the roles of G-value in the current design and operation practices. The results of this study clearly show that many arguments and doubts are possible about the scientific correctness of G-value, and its current use. This is because the G-value attempts to represent the turbulent and complicated factual velocity field in a jar. Also, the results suggest that it is still a good index for representing some aspects of mixing condition, at least, mixing intensity. However, it cannot represent the distribution of velocity gradients in a jar, which is an important factor for mixing. This study as a result suggests developing another index for representing the distribution to be used with the G-value.