Gudrun Maria Feuchtner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Gudrun Maria Feuchtner has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Dieter Zur Nedden
6 shared publicationsJohannes Bonatti
5 shared publications- Thomas Schachner
Department of Cardiac Surgery, Medical University Innsbruck, Innsbruck, Austria
5 shared publications - Wolfgang Dichtl
Department of Internal Medicine III (Cardiology and Angiology), Medical University Innsbruck , Innsbruck
4 shared publications Alexander Smekal
3 shared publicationsAmmar Mallouhi
3 shared publications
Latest Publications
- 1 October 2006
- Published by IMR Press in The Heart Surgery Forum
- Vol. 9 (5) , E754-E758
Evaluation of Ascending Aortic Atherosclerosis with 16-Multidetector Computed Tomography Is Useful before Total Endoscopic Coronary Bypass Surgery
The purpose of this study was to investigate the assessment of ascending aortic atherosclerosis with 16-multidetector computed tomography (16-MDCT) angiography prior to total endoscopic coronary artery bypass (TECAB) surgery. Forty-five patients were examined with electrocardiogram-gated, 16-MDCT angiography. The presence of atherosclerosis at the ascending aorta was graduated as severe (>50% of circumference) or as mild (<50% of circumference). Ascending aortic plaque composition was evaluated based on CT densities expressed as Hounsfield units (HU). TECABs using the Da Vinci telemanipulator were performed either on the arrested heart (n = 39) with an intra-aortic cardiopulmonary bypass (CPB) perfusion device or on the beating heart (n = 6) in patients with severe atherosclerosis. The presence of mild atherosclerosis at the ascending aorta (11/39) was associated with intra-aortic CPB perfusion device-related difficulties such as intra-aortic balloon migration (BM) or balloon rupture (P = .007) in arrested heart TECABs. The CT density of atherosclerotic plaque in patients with BM was mean 58 HU +/- 51 standard deviation (SD), suggesting noncalcifying plaque. In patients without BM, CT density of plaque was mean 526 HU +/- 306 SD corresponding to calcifying plaque (P < .001). Balloon rupture occurred in 2 patients who had calcifying plaque at the ascending aorta. Evaluation of ascending aortic atherosclerosis with 16-MDCT angiography is useful prior to TECAB surgery. Even mild atherosclerosis of the ascending aorta is associated with intraoperative difficulties regarding the remote-access perfusion system that is used for arrested heart TECAB surgery.
- 1 October 2006
- Published by IMR Press in The Heart Surgery Forum
- Vol. 9 (5) , E754-E758
Evaluation of Ascending Aortic Atherosclerosis with 16-Multidetector Computed Tomography Is Useful before Total Endoscopic Coronary Bypass Surgery
The purpose of this study was to investigate the assessment of ascending aortic atherosclerosis with 16-multidetector computed tomography (16-MDCT) angiography prior to total endoscopic coronary artery bypass (TECAB) surgery. Forty-five patients were examined with electrocardiogram-gated, 16-MDCT angiography. The presence of atherosclerosis at the ascending aorta was graduated as severe (>50% of circumference) or as mild (<50% of circumference). Ascending aortic plaque composition was evaluated based on CT densities expressed as Hounsfield units (HU). TECABs using the Da Vinci telemanipulator were performed either on the arrested heart (n = 39) with an intra-aortic cardiopulmonary bypass (CPB) perfusion device or on the beating heart (n = 6) in patients with severe atherosclerosis. The presence of mild atherosclerosis at the ascending aorta (11/39) was associated with intra-aortic CPB perfusion device-related difficulties such as intra-aortic balloon migration (BM) or balloon rupture (P = .007) in arrested heart TECABs. The CT density of atherosclerotic plaque in patients with BM was mean 58 HU +/- 51 standard deviation (SD), suggesting noncalcifying plaque. In patients without BM, CT density of plaque was mean 526 HU +/- 306 SD corresponding to calcifying plaque (P < .001). Balloon rupture occurred in 2 patients who had calcifying plaque at the ascending aorta. Evaluation of ascending aortic atherosclerosis with 16-MDCT angiography is useful prior to TECAB surgery. Even mild atherosclerosis of the ascending aorta is associated with intraoperative difficulties regarding the remote-access perfusion system that is used for arrested heart TECAB surgery.
- 1 July 2006
- Vol. 15 (4) , 494-8
Aortic valve calcification as quantified with multislice computed tomography predicts short-term clinical outcome in patients with asymptomatic aortic stenosis.
Aortic valve calcification may be an independent risk factor for adverse clinical outcome. The study aim was to assess the predictive value of possible risk factors, including the severity of aortic valve calcification as quantified with 16-multislice computed tomography (MSCT) for adverse short-term clinical outcome in patients with asymptomatic, degenerative aortic stenosis (AS). Possible risk factors for adverse short-term clinical outcome were prospectively tested in 34 consecutive patients with asymptomatic AS as follows: (i) aortic valve calcium (AVC) score as quantified with MSCT; (ii) echocardiographic parameters--aortic valve area (AVA) calculated with continuity equation, mean and maximal transvalvular pressure gradients, end-diastolic septal wall diameter; and (iii) laboratory tests (brain natriuretic peptide (BNP), C-reactive protein (CRP)). Within 18-24 months of follow up, 11 of 34 patients developed a major adverse clinical outcome. Ten patients suffered from onset of symptoms accompanied by hemodynamic progression, and one patient died from sudden cardiac death. Six of these 10 patients underwent aortic valve replacement, one patient declined surgery, and three patients were not accepted for surgery (one of these died suddenly shortly afterwards). The aortic valve calcium score was the strongest predictor of a major adverse clinical event (p < 0.001) among all parameters assessed (1,928 +/- 789 versus 5,111 +/- 2,409 Agatston units). The plasma level of BNP (p = 0.003), mean transvalvular pressure gradient (p = 0.002) and AVA (p = 0.003) were also risk factors for adverse clinical outcome. The AVC score as quantified with MSCT predicted adverse short-term clinical outcome in patients with asymptomatic AS. In patients with severe aortic valve calcification, close follow up examinations are mandatory, and early elective surgery may be considered even in the absence of symptoms. MSCT provides a comprehensive non-invasive imaging approach for risk stratification in patients with asymptomatic AS.
- 1 July 2006
- Vol. 15 (4) , 494-8
Aortic valve calcification as quantified with multislice computed tomography predicts short-term clinical outcome in patients with asymptomatic aortic stenosis.
Aortic valve calcification may be an independent risk factor for adverse clinical outcome. The study aim was to assess the predictive value of possible risk factors, including the severity of aortic valve calcification as quantified with 16-multislice computed tomography (MSCT) for adverse short-term clinical outcome in patients with asymptomatic, degenerative aortic stenosis (AS). Possible risk factors for adverse short-term clinical outcome were prospectively tested in 34 consecutive patients with asymptomatic AS as follows: (i) aortic valve calcium (AVC) score as quantified with MSCT; (ii) echocardiographic parameters--aortic valve area (AVA) calculated with continuity equation, mean and maximal transvalvular pressure gradients, end-diastolic septal wall diameter; and (iii) laboratory tests (brain natriuretic peptide (BNP), C-reactive protein (CRP)). Within 18-24 months of follow up, 11 of 34 patients developed a major adverse clinical outcome. Ten patients suffered from onset of symptoms accompanied by hemodynamic progression, and one patient died from sudden cardiac death. Six of these 10 patients underwent aortic valve replacement, one patient declined surgery, and three patients were not accepted for surgery (one of these died suddenly shortly afterwards). The aortic valve calcium score was the strongest predictor of a major adverse clinical event (p < 0.001) among all parameters assessed (1,928 +/- 789 versus 5,111 +/- 2,409 Agatston units). The plasma level of BNP (p = 0.003), mean transvalvular pressure gradient (p = 0.002) and AVA (p = 0.003) were also risk factors for adverse clinical outcome. The AVC score as quantified with MSCT predicted adverse short-term clinical outcome in patients with asymptomatic AS. In patients with severe aortic valve calcification, close follow up examinations are mandatory, and early elective surgery may be considered even in the absence of symptoms. MSCT provides a comprehensive non-invasive imaging approach for risk stratification in patients with asymptomatic AS.
- 1 June 2006
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 186 (6) , 1676-1681
Diagnostic Performance of MDCT for Detecting Aortic Valve Regurgitation
OBJECTIVE. This study evaluates whether ECG-gated 16-MDCT coronary angiography provides a reliable imaging technique for detecting aortic regurgitation (AR).SUBJECTS AND METHODS. We examined 71 patients prospectively with 16-MDCT angiography using retrospective ECG gating during the mid-to-end diastolic phase. A visible central valvular leakage area was considered as a diagnostic criterion for AR. The central valvular leakage area was quantified in patients with positive transthoracic echocardiography (TTE). We compared 16-MDCT to Doppler TTE, the accepted diagnostic standard based on semiquantitative regurgitation jet analysis (grade 0-3+ for mild, moderate, and severe).RESULTS. The overall sensitivity of 16-MDCT for the identification of patients with AR was 81%. The specificity was 91%, the negative predictive value was 70%, and the positive predictive value was 95%. Of the 71 patients, 48 had AR determined by TTE, and 16-MDCT correctly detected AR in 39 of those 48 patients. The sensitivity of 16-MDCT...
- 1 June 2006
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 186 (6) , 1676-1681
Diagnostic Performance of MDCT for Detecting Aortic Valve Regurgitation
OBJECTIVE. This study evaluates whether ECG-gated 16-MDCT coronary angiography provides a reliable imaging technique for detecting aortic regurgitation (AR).SUBJECTS AND METHODS. We examined 71 patients prospectively with 16-MDCT angiography using retrospective ECG gating during the mid-to-end diastolic phase. A visible central valvular leakage area was considered as a diagnostic criterion for AR. The central valvular leakage area was quantified in patients with positive transthoracic echocardiography (TTE). We compared 16-MDCT to Doppler TTE, the accepted diagnostic standard based on semiquantitative regurgitation jet analysis (grade 0-3+ for mild, moderate, and severe).RESULTS. The overall sensitivity of 16-MDCT for the identification of patients with AR was 81%. The specificity was 91%, the negative predictive value was 70%, and the positive predictive value was 95%. Of the 71 patients, 48 had AR determined by TTE, and 16-MDCT correctly detected AR in 39 of those 48 patients. The sensitivity of 16-MDCT...
- 1 November 2005
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 185 (5) , 1289-1293
High-Resolution 16-MDCT Evaluation of Radial Artery for Potential Use as Coronary Artery Bypass Graft: A Feasibility Study
OBJECTIVE. The objective of our study was to assess the feasibility of using 16-MDCT angiography for the preoperative assessment of the radial and ulnar arteries and the palmar arches in patients scheduled for radial artery harvesting for coronary artery bypass graft (CABG) surgery. CONCLUSION. Sixteen-MDCT angiography shows promise for the noninvasive preoperative assessment of the radial artery as a CABG donor site.
- 1 November 2005
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 185 (5) , 1289-1293
High-Resolution 16-MDCT Evaluation of Radial Artery for Potential Use as Coronary Artery Bypass Graft: A Feasibility Study
OBJECTIVE. The objective of our study was to assess the feasibility of using 16-MDCT angiography for the preoperative assessment of the radial and ulnar arteries and the palmar arches in patients scheduled for radial artery harvesting for coronary artery bypass graft (CABG) surgery. CONCLUSION. Sixteen-MDCT angiography shows promise for the noninvasive preoperative assessment of the radial artery as a CABG donor site.
- 31 August 2005
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 130 (2) , 587.e1-587.e3
Acute aortic dissection with coronary ostium involvement and aortic valve regurgitation: Three-dimensional visualization with multislice computed tomography
- 31 August 2005
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 130 (2) , 587.e1-587.e3
Acute aortic dissection with coronary ostium involvement and aortic valve regurgitation: Three-dimensional visualization with multislice computed tomography
- 30 March 2004
- Published by Wolters Kluwer Health in Circulation
- Vol. 109 (12) , e165-6
Prolapsing Atrial Myxoma
- 30 March 2004
- Published by Wolters Kluwer Health in Circulation
- Vol. 109 (12) , e165-6
Prolapsing Atrial Myxoma