Fabrice Rossignol
Research Subjects
Fabrice Rossignol has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Roland Perrin
Clinique de Grosbois, Boissy Saint Léger, France
2 shared publicationsCaroline Elie
Clinique de Grosbois, Domaine de Grosbois, Boissy Saint Léger, France, and Clinique Equine, La Brosse, Saint Lambert des Bois, France
1 shared publicationFrancis Desbrosse
Clinique de Grosbois, Domaine de Grosbois, Boissy Saint Léger, France, and Clinique Equine, La Brosse, Saint Lambert des Bois, France
1 shared publicationK. Josef Boening
Clinique de Grosbois, Boissy Saint Léger, France
1 shared publication
Latest Publications
- 4 August 2007
- Published by Wiley in Veterinary Surgery
- Vol. 36 (6) , 557-562
Laparoscopic Hernioplasty in Recumbent Horses Using Transposition of a Peritoneal Flap
To evaluate the efficacy of a laparoscopic peritoneal flap hernioplasty (PFH) to close anatomically the vaginal ring and to evaluate its protective effect in horses with a history of strangulated inguinal hernia (SIH) against future herniation. Prospective study. A first group of 5 ponies, 3 horses and 1 donkey with no history of SIH and a second group of 4 horses 'clinical cases' with a history of SIH. A laparoscopic PFH was effected on all horses under general anaesthesia. Peritoneum ventro-lateral to the vaginal ring was elevated and cut on 3 sides, separated from the underlying muscle, then inverted and attached dorso-medially and laterally to the parietal wall using intra-corporeal stitches (6 cases) or laparoscopic staples (7 cases). Animals of the first group (n=9) underwent a standing laparoscopy 7 days post-operatively to visualize the vaginal rings. Horses of the second group were followed to confirm the absence of re-herniation. The laparoscopic check-up showed that the vaginal ring had been effectively and completely covered in all cases except the first one. No adhesions was observed. In the four clinical cases, none of the horses have had a reccurence of SIH at the time of writing (6 months to 4 years). Laparoscopic hernioplasty on a recumbent horse is feasible by closing the vaginal ring with a peritoneal flap. This technique was efficient in our cases to prevent recurrence of SIH but more cases are needed. This technique may reduce inflammation and irritation of the spermatic cord, which could otherwise jeopardise the animal's breeding career. Laparoscopic PFH coud be used in horses with a history of SIH.
- 4 August 2007
- Published by Wiley in Veterinary Surgery
- Vol. 36 (6) , 557-562
Laparoscopic Hernioplasty in Recumbent Horses Using Transposition of a Peritoneal Flap
To evaluate the efficacy of a laparoscopic peritoneal flap hernioplasty (PFH) to close anatomically the vaginal ring and to evaluate its protective effect in horses with a history of strangulated inguinal hernia (SIH) against future herniation. Prospective study. A first group of 5 ponies, 3 horses and 1 donkey with no history of SIH and a second group of 4 horses 'clinical cases' with a history of SIH. A laparoscopic PFH was effected on all horses under general anaesthesia. Peritoneum ventro-lateral to the vaginal ring was elevated and cut on 3 sides, separated from the underlying muscle, then inverted and attached dorso-medially and laterally to the parietal wall using intra-corporeal stitches (6 cases) or laparoscopic staples (7 cases). Animals of the first group (n=9) underwent a standing laparoscopy 7 days post-operatively to visualize the vaginal rings. Horses of the second group were followed to confirm the absence of re-herniation. The laparoscopic check-up showed that the vaginal ring had been effectively and completely covered in all cases except the first one. No adhesions was observed. In the four clinical cases, none of the horses have had a reccurence of SIH at the time of writing (6 months to 4 years). Laparoscopic hernioplasty on a recumbent horse is feasible by closing the vaginal ring with a peritoneal flap. This technique was efficient in our cases to prevent recurrence of SIH but more cases are needed. This technique may reduce inflammation and irritation of the spermatic cord, which could otherwise jeopardise the animal's breeding career. Laparoscopic PFH coud be used in horses with a history of SIH.
- 9 January 2006
- Published by Wiley in Veterinary Surgery
- Vol. 35 (1) , 49-54
In Vitro Comparison of Two Techniques for Suture Prosthesis Placement in the Muscular Process of the Equine Arytenoid Cartilage
Objective—To compare in vitro the load necessary for a partial and complete rupture of the muscular process arytenoid cartilage when a suture prosthesis is positioned by a bone trocar versus a trocar point needle and to compare failure mode.Study Design—Experimental using cadaver specimens.Sample Population—Larynges from 18 Thoroughbred race horses, aged 2–20 years.Methods—Arytenoid cartilages were separated randomly into 2 groups: group 1—suture prosthesis inserted directly through the muscular process using a curved trocar point needle and group 2—suture passed through a hole predrilled with a 3 mm bone trocar. Distracting force (constant rate, 1 mm/s) was applied to the suture until failure of the muscular process. Partial failure load, maximum load at complete failure, and force–time curve were recorded. Each arytenoid cartilage was examined, radiographed, and classified as having a linear or curved failure plane.Results—No significant differences in mechanical test variables were detected. Failure mode followed the fissures occurring at the beginning of failure and then followed the tension axis. Significantly more linear failures occurred in group 2 (trocar) and more curved failures occurred in group 1 (needle).Conclusion—Use of a bone trocar for tunneling through the muscular process may reduce fissure formation.Clinical Relevance—Use of bone trocar to create a hole in the muscular process of the arytenoid cartilage for suture passage in laryngoplasty may reduce fissure formation and decrease the risk of cartilage failure from suture pullout.
- 9 January 2006
- Published by Wiley in Veterinary Surgery
- Vol. 35 (1) , 49-54
In Vitro Comparison of Two Techniques for Suture Prosthesis Placement in the Muscular Process of the Equine Arytenoid Cartilage
Objective—To compare in vitro the load necessary for a partial and complete rupture of the muscular process arytenoid cartilage when a suture prosthesis is positioned by a bone trocar versus a trocar point needle and to compare failure mode.Study Design—Experimental using cadaver specimens.Sample Population—Larynges from 18 Thoroughbred race horses, aged 2–20 years.Methods—Arytenoid cartilages were separated randomly into 2 groups: group 1—suture prosthesis inserted directly through the muscular process using a curved trocar point needle and group 2—suture passed through a hole predrilled with a 3 mm bone trocar. Distracting force (constant rate, 1 mm/s) was applied to the suture until failure of the muscular process. Partial failure load, maximum load at complete failure, and force–time curve were recorded. Each arytenoid cartilage was examined, radiographed, and classified as having a linear or curved failure plane.Results—No significant differences in mechanical test variables were detected. Failure mode followed the fissures occurring at the beginning of failure and then followed the tension axis. Significantly more linear failures occurred in group 2 (trocar) and more curved failures occurred in group 1 (needle).Conclusion—Use of a bone trocar for tunneling through the muscular process may reduce fissure formation.Clinical Relevance—Use of bone trocar to create a hole in the muscular process of the arytenoid cartilage for suture passage in laryngoplasty may reduce fissure formation and decrease the risk of cartilage failure from suture pullout.